0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3VA5211-7EC61-0AA0

3VA5211-7EC61-0AA0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3VA5211-7EC61-0AA0 数据手册
Data sheet 3VA5211-7EC61-0AA0 circuit breaker 3VA5 UL Frame 250 breaking capacity class C 100 kA @ 480 V 2pole, line protection TM230, FTAM, In=110 A overload protection Ir=110 A permanently set short-circuit protection Ii=5...10 x In without connection Model product brand name SENTRON product designation Molded-case circuit breaker product designation / according to UL file CFAS design of the product System protection design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type) Yes design of the load switch / according to UL 489 / High-IntensityDischarge circuit breaker (HID Type) No design of the load switch / according to UL 489 / Switching Duty circuit breaker (SWD Type) No design of the overcurrent release TM230 protection function of the overcurrent release LI number of poles 2 General technical data insulation voltage / rated value 800 V operating voltage / at DC / rated value 500 V operating voltage / at AC / rated value 690 V power loss [W] / maximum 15 W power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 7.53 W mechanical service life (operating cycles) / typical 20 000 electrical endurance (operating cycles) / at AC-1 / at 380/415 V 8 000 electrical endurance (operating cycles) / at AC-1 / at 690 V 4 000 electrical endurance (operating cycles) / at 480 V 8 000 electrical endurance (operating cycles) / at 600 V 4 000 product feature / for neutral conductors / upgradable/retrofittable / short-circuit and overload proof No product function ● communication function No ● other measurement function No Net Weight 1.9 kg Current marking / according to UL 489 / 100%-rated breaker No operational current ● at 40 °C 110 A ● at 45 °C 107 A ● at 50 °C 104 A ● at 55 °C 100 A ● at 60 °C 97 A ● at 65 °C 94 A ● at 70 °C 91 A 3VA52117EC610AA0 Page 1/6 6/2/2024 Subject to change without notice © Copyright Siemens Switching capacity according to IEC 60947 switching capacity class of the circuit breaker C maximum short-circuit current breaking capacity (Icu) ● at 240 V 200 kA ● at 415 V 110 kA ● at 690 V 10 kA operating short-circuit current breaking capacity (Ics) ● at 240 V 200 kA ● at 415 V 110 kA ● at 690 V 10 kA short-circuit current making capacity (Icm) ● at 240 V 440 kA ● at 415 V 242 kA ● at 690 V 17 kA design of short-circuit protection For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter Switching capacity according to UL 489 current breaking capacity ● at 240 V 200 kA ● at 480 V 100 kA ● at 600 V 35 kA Adjustable parameters adjustable response value setting current (Ir) / of the L-trip / with I2t characteristic ● minimum 110 A ● maximum 110 A adjustable response value delay time (tr) / for L-tripping / with I2t characteristic ● minimum 1s ● maximum 1s adjustable response value setting current (Ii) / for I-tripping ● minimum 550 A ● maximum 1 100 A adjustable setting current (InN) / for N-tripping ● minimum 0A ● maximum 0A product function / grounding protection No Mechanical Design product component ● undervoltage release No ● voltage trigger No ● trip indicator No height [in] 7.28 in height 185 mm width [in] 4.13 in width 105 mm depth [in] 3.27 in depth 83 mm Connections arrangement of electrical connectors / for main current circuit Without connection type of electrical connection / for main current circuit Without Auxiliary circuit number of CO contacts / for auxiliary contacts 0 Accessories product extension / optional / motor drive Yes Environmental conditions protection class IP / on the front IP40 ambient temperature ● during operation / minimum -25 °C ● during operation / maximum 70 °C 3VA52117EC610AA0 Page 2/6 6/2/2024 Subject to change without notice © Copyright Siemens ● during storage / minimum -40 °C ● during storage / maximum 80 °C reference code / according to IEC 81346-2 Q Approvals / Certificates General Product Approval Confirmation General Product Approval EMV Marine / Shipping Miscellaneous other Confirmation Environment Miscellaneous Miscellaneous Environmental Confirmations Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/lowvoltage/catalogs Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA5211-7EC61-0AA0 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3VA5211-7EC61-0AA0 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA5211-7EC61-0AA0 CAx-Online-Generator http://www.siemens.com/cax Tender specifications http://www.siemens.com/specifications 3VA52117EC610AA0 Page 3/6 6/2/2024 Subject to change without notice © Copyright Siemens 3 1 -Q 3VA52117EC610AA0 Page 4/6 6/2/2024 I>> 4 2 I>> Subject to change without notice © Copyright Siemens CB 1 2 3 4 last modified: 3VA52117EC610AA0 Page 5/6 6/16/2022 6/2/2024 Subject to change without notice © Copyright Siemens 3VA52117EC610AA0 Page 6/6 6/2/2024 Subject to change without notice © Copyright Siemens
3VA5211-7EC61-0AA0 价格&库存

很抱歉,暂时无法提供与“3VA5211-7EC61-0AA0”相匹配的价格&库存,您可以联系我们找货

免费人工找货