3VA5240-5ED31-1AA0

3VA5240-5ED31-1AA0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3VA5240-5ED31-1AA0 数据手册
Data sheet 3VA5240-5ED31-1AA0 circuit breaker 3VA5 UL Frame 250 breaking capacity class M 35 kA @ 480 V 3pole, line protection TM210, FTFM, In=40 A overload protection Ir=40 A permanently set short-circuit protection Ii=10 x In UL489 SB (naval), 50 degrees Celsius without connection Model product brand name SENTRON product designation Molded-case circuit breaker product designation / according to UL file MFAM design of the product System protection design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type) Yes design of the load switch / according to UL 489 / High-IntensityDischarge circuit breaker (HID Type) No design of the load switch / according to UL 489 / Switching Duty circuit breaker (SWD Type) No design of the overcurrent release TM210 protection function of the overcurrent release LI number of poles 3 General technical data operating voltage / at AC / rated value 690 V power loss [W] / maximum 20 W power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 6.8 W mechanical service life (operating cycles) / typical 20 000 electrical endurance (operating cycles) / at AC-1 / at 380/415 V 8 000 electrical endurance (operating cycles) / at AC-1 / at 690 V 4 000 electrical endurance (operating cycles) / at 480 V 8 000 electrical endurance (operating cycles) / at 600 V 4 000 product feature / for neutral conductors / upgradable/retrofittable / short-circuit and overload proof No product function ● communication function No ● other measurement function No Net Weight 2 kg Current marking / according to UL 489 / 100%-rated breaker No Switching capacity according to IEC 60947 switching capacity class of the circuit breaker M design of short-circuit protection For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter Switching capacity according to UL 489 current breaking capacity ● at 240 V 85 kA ● at 480 V 35 kA ● at 600 V 18 kA 3VA52405ED311AA0 Page 1/5 5/26/2024 Subject to change without notice © Copyright Siemens Adjustable parameters adjustable response value setting current (Ir) / of the L-trip / with I2t characteristic ● minimum 40 A ● maximum 40 A adjustable response value delay time (tr) / for L-tripping / with I2t characteristic ● minimum 1s ● maximum 1s adjustable response value setting current (Ii) / for I-tripping ● minimum 400 A ● maximum 400 A adjustable setting current (InN) / for N-tripping ● minimum 0A ● maximum 0A product function / grounding protection No Mechanical Design product component ● undervoltage release No ● voltage trigger No ● trip indicator No height [in] 7.28 in height 185 mm width [in] 4.13 in width 105 mm depth [in] 3.27 in depth 83 mm Connections arrangement of electrical connectors / for main current circuit Without connection type of electrical connection / for main current circuit Without Auxiliary circuit number of CO contacts / for auxiliary contacts 0 Accessories product extension / optional / motor drive Yes Environmental conditions protection class IP / on the front IP40 ambient temperature ● during operation / minimum -25 °C ● during operation / maximum 70 °C ● during storage / minimum -40 °C ● during storage / maximum 80 °C Approvals / Certificates General Product Approval Confirmation General Product Approval EMV Marine / Shipping Miscellaneous other Miscellaneous 3VA52405ED311AA0 Page 2/5 other Confirmation Miscellaneous Environment Environmental Confirmations 5/26/2024 Subject to change without notice © Copyright Siemens Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/lowvoltage/catalogs Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA5240-5ED31-1AA0 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3VA5240-5ED31-1AA0 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA5240-5ED31-1AA0 CAx-Online-Generator http://www.siemens.com/cax Tender specifications http://www.siemens.com/specifications 3VA52405ED311AA0 Page 3/5 5/26/2024 Subject to change without notice © Copyright Siemens 5 3 1 -Q I>> 6 I>> 4 2 I>> CB last modified: 3VA52405ED311AA0 Page 4/5 1 2 3 4 5 6 6/16/2022 5/26/2024 Subject to change without notice © Copyright Siemens 3VA52405ED311AA0 Page 5/5 5/26/2024 Subject to change without notice © Copyright Siemens
3VA5240-5ED31-1AA0 价格&库存

很抱歉,暂时无法提供与“3VA5240-5ED31-1AA0”相匹配的价格&库存,您可以联系我们找货

免费人工找货