Data sheet
3VA6340-5KM31-0AA0
circuit breaker 3VA6 UL Frame 400 breaking capacity class M 35 kA @ 480 V 3pole, line protection ETU830, LIG, In=400 A overload protection Ir=160 A...400 A
short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In,
tg=0.05-0.8s without connection
Model
product brand name
SENTRON
product designation
Molded-case circuit breaker
product designation / according to UL file
MJAE
design of the product
System protection
design of the load switch / according to UL 489 / Heating, Air
Conditioning, and Refrigeration circuit breaker (HACR Type)
Yes
design of the overcurrent release
ETU830
protection function of the overcurrent release
LIG
number of poles
3
General technical data
insulation voltage / rated value
800 V
operating voltage / at AC / rated value
690 V
power loss [W] / maximum
70 W
power loss [W] / for rated value of the current / at AC / in hot
operating state / per pole
23.33 W
mechanical service life (operating cycles) / typical
20 000
electrical endurance (operating cycles) / at AC-1 / at 380/415 V
6 000
electrical endurance (operating cycles) / at AC-1 / at 690 V
4 200
electrical endurance (operating cycles) / at 480 V
6 000
electrical endurance (operating cycles) / at 600 V
4 200
product feature / for neutral conductors / upgradable/retrofittable
/ short-circuit and overload proof
No
ground-fault monitoring version
Summation current formation L-conductor
product function
● communication function
Yes
● other measurement function
Yes
Net Weight
5.3 kg
Current
marking / according to UL 489 / 100%-rated breaker
No
operational current
● at 40 °C
400 A
● at 45 °C
400 A
● at 50 °C
400 A
● at 55 °C
375 A
● at 60 °C
350 A
● at 65 °C
325 A
● at 70 °C
300 A
3VA63405KM310AA0
Page 1/6
5/17/2024
Subject to change without notice
© Copyright Siemens
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker
M
maximum short-circuit current breaking capacity (Icu)
● at 240 V
85 kA
● at 415 V
55 kA
● at 690 V
5 kA
operating short-circuit current breaking capacity (Ics)
● at 240 V
85 kA
● at 415 V
55 kA
● at 690 V
5 kA
short-circuit current making capacity (Icm)
● at 240 V
187 kA
● at 415 V
121 kA
● at 690 V
7.5 kA
Switching capacity according to UL 489
current breaking capacity
● at 240 V
100 kA
● at 480 V
35 kA
● at 600 V
18 kA
Adjustable parameters
adjustable response value setting current (Ir) / of the L-trip / with
I2t characteristic
● minimum
150 A
● maximum
400 A
adjustable response value delay time (tr) / for L-tripping / with I2t
characteristic
● minimum
0.5 s
● maximum
17 s
adjustable response value setting current (Ii) / for I-tripping
● minimum
600 A
● maximum
4 000 A
adjustable current response value current / for G-tripping / with
standard characteristic
● initial value
80 A
● full-scale value
400 A
adjustable response value delay time (tg) / for G-tripping / with
I0t characteristic
● minimum
0.05 s
● maximum
0.8 s
adjustable response value setting current (Ig) / for G-tripping /
with I2t characteristic
● minimum
80 A
● maximum
400 A
adjustable response value delay time (tg) / for G-tripping / with
I2t characteristic
● minimum
0.05 s
● maximum
0.8 s
adjustable setting current (InN) / for N-tripping
● minimum
0A
● maximum
0A
product function / grounding protection
Yes
Mechanical Design
product component
● undervoltage release
No
● voltage trigger
No
● trip indicator
No
height [in]
9.76 in
height
248 mm
width [in]
5.43 in
width
138 mm
depth [in]
4.33 in
depth
110 mm
3VA63405KM310AA0
Page 2/6
5/17/2024
Subject to change without notice
© Copyright Siemens
Connections
arrangement of electrical connectors / for main current circuit
Without connection
type of electrical connection / for main current circuit
Without
Auxiliary circuit
number of CO contacts / for auxiliary contacts
0
Accessories
product extension / optional / motor drive
Yes
Environmental conditions
protection class IP / on the front
IP40
ambient temperature
● during operation / minimum
-25 °C
● during operation / maximum
70 °C
● during storage / minimum
-40 °C
● during storage / maximum
80 °C
Environmental footprint
Siemens Eco Profile (SEP)
Siemens EcoTech
reference code / according to IEC 81346-2
Q
Approvals / Certificates
General Product Approval
Confirmation
General Product Approval
EMV
Marine / Shipping
Miscellaneous
Marine / Shipping
other
Confirmation
Dangerous Good
Transport Information
Miscellaneous
Miscellaneous
Environment
Environmental Confirmations
Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA6340-5KM31-0AA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3VA6340-5KM31-0AA0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA6340-5KM31-0AA0
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications
3VA63405KM310AA0
Page 3/6
5/17/2024
Subject to change without notice
© Copyright Siemens
5
3
1
-Q
ETU830
L
I>> I
I>>
I>>
G
I>>
P
I>>
I>>
MF
I>>
3VA63405KM310AA0
Page 4/6
5/17/2024
-X2
6
4
2
EFB/
MMB
Subject to change without notice
© Copyright Siemens
CB
1
2
3
4
5
6
ETU830
EFB/
MMB
I>>
L
last modified:
3VA63405KM310AA0
Page 5/6
I
-X2
P
G MF
3/11/2024
5/17/2024
Subject to change without notice
© Copyright Siemens
3VA63405KM310AA0
Page 6/6
5/17/2024
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“3VA6340-5KM31-0AA0”相匹配的价格&库存,您可以联系我们找货
免费人工找货