0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
40404-025

40404-025

  • 厂商:

    SIEMENS

  • 封装:

    -

  • 描述:

    40404-025

  • 数据手册
  • 价格&库存
40404-025 数据手册
Selection and application guide For use in Texas and Oklahoma Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General Information - - - 2-3 Residential, 1 phase, 3 wire 135A 1 4&5 4 Residential, 1 phase, 3 wire 200A 1 4&5 5 Residential, 1 phase, 3 wire, Horizontal Gang 100/150A 2-4 4 6 Residential, 1 phase, 3 wire, Horizontal Gang 200A 2-6 4&5 7 Commercial/Industrial, 1 and 3 phase, 3 wire, Type MQ 200A 1 5&7 8 Commercial/Industrial, 1 phase, 3 wire, Polyphase, 3 or 4 wire 200A 1 4, 5, & 7 9 Commercial/Industrial, 1 phase, 3 wire, Polyphase, 4 wire 320A 1 4&5 10 Commercial/Industrial, 1 phase, 3 wire, Polyphase, 4 wire 320A 1 7 11 Residential, 1 phase, 3 wire 400/480A 1 4 12 Residential/Commercial/Industrial, Polyphase, 3 or 4 wire 400/480A 1 7 13 Residential, Meter Main, 1 phase, 3 wire 100/200A 1 4&5 14 Type PTS, Transformer-Rated with Test Switch Provision - - - 15 Type HQ-T, Transformer-Rated - - - 16 Type HQ-TS, Transformer-Rated with Test Switch Provision - - - 18 Air Conditioning Disconnects - - - 20 Spa Panels - - - 21 Connector lugs - - - 22-23 Accessories - - - 24 Terms of Sale, Meter Mounting Device Applications - - - 25 Represented by: JD Martin Inc. 1801 Royal Lane, Suite 100 Dallas, TX 75229 Phone: (972) 277-5600 | Meter Mounting Equipment for use in Texas and Oklahoma 1 Meter Mounting Equipment The standard for quality For more than 50 years, meter mounting devices that are now manufactured under the Talon Brand, have been known throughout the industry for innovation and quality. From our proprietary K-Base to our heavy duty HQ lever bypass socket, Talon products are known throughout the industry for innovation and quality. Talon meter sockets are built for safety, ease of installation, and long term quality. That’s why we use stainless steel hardware, polyester powder coat paint for long lasting protection, and Type G-90 galvanized steel or 3003 grade aluminum for all of our enclosures. It’s also why we use an all-copper current path in our commercial sockets. All of this adds up to why utilities, OEM’s, and contractors recognize Talon meter mounting devices across the country as the leader in design, quality, and workmanship. Quality is the reason many utilities and electricians specify Talon products. Talon products - the standard for quality and design. General information Materials: 16 gauge, galvanized steel, G-90 14 gauge, galvanized steel, G-90 14 gauge, aluminum 12 gauge, aluminum Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Aluminum - Mill finish 2 | Latches: All swing latches are stainless steel Block material: AS/AT, MQ, HQ, K-4 and K-7 - Glass reinforced polyester Terminals: AS/AT - Tin-plated aluminum extrusions 6061-T6 MQ, HQ, - Tin-plated copper HQ-5 block assembly The standard for quality. Standards: Products cataloged herein meet or exceed the following standards: UL 486B, UL 414, NEMA 250, ANSI C12.7 Florida Meter Group requirements Voltage: All devices are rated at 600V AC Type K-4 rated at 300V AC Meter Mounting Equipment for use in Texas and Oklahoma Meter Mounting Equipment Meter socket terminology Maximum and continuous ampacity UL and NEMA standards allow most electrical devices to be tested at one amp level (“continuous”), then allowed 125% rating as “maximum”. For example, a “400 Amp” socket may either mean 400 Amps continuous (K-4) or 400A Max, 320A continuous which is also made by most competitors. Wire sizes - ampacity Connectors accept a fairly wide variety of wire sizes. \On the AT socket, a 350 MCM connector accepts conductors from #6 up to 350 MCM. The NEC specifies the ampacity of each wire size and type, also taking into account how the wire is installed in conduit. Lay-in and stud terminals Lay-in terminals are fixed and may not be modified in the field to accept other wire sizes or parallel conductors. Stud terminals accept either lugs (see Product Schedule 497) or compression fittings (not available from Talon). Common uses for studs include where the field wiring may be either single or parallel. Terminals may be mixed on the line and load sides, e.g. stud on the line and lay-in on the load side. Ringless/Ring style Ring-type is an older, vanishing concept requiring a sealing ring. Talon recently added tooling to build this type of socket for the few remaining utilities that require them. In ringless design, the seal is made not on a sealing ring but using the cover and “swing latch” as the point of sealing. Overhead/Underground Sockets for UG service are usually wider in order to provide space for the conductors to loop around the block to the top connectors. Since more material is required in the enclosure, UG sockets are more expensive than OH sockets. Quite popular are combination units (OH/UG) which may be used in either service, and require a cover plate if used with UG feed. Hubs and cover plates Top of socket with hub opening has a flanged lip to keep out moisture. This requires a hub or cover plate to close. There are two sizes of openings: “small” for conduit hubs with sizes of 1”, 1-1/4”, 1-1/2”, 2”, and 2-1/2”; and “large” for conduit hubs with sizes 3”, 3-1/2”, and 4”. See Product Schedule 499. Talon hub openings conform to ANSI C12.7 specs and are interchangeable with other socket manufacturers, but are not interchangeable with panel board style hubs. Bypass types A self-contained meter completes the circuit between the utility and the customer. In order to change the meter, the circuit must be broken, turning off the power to the customer. This is not acceptable in commercial establishments, or in many other types of services. A bypass allows a parallel path for the current flow, unmetered, while the meter is pulled. Types are: a) Lever-operated jaw release, also known as jaw clamping lever bypass (Talon type HQ). The best, because the meter cannot accidentally be pulled unless the bypass is engaged. Pulling the meter would also be a major safety hazard if there is a 480V installation and/or a large load in place, as the meter would then act as a switch, and cause arc. b) Lever-operated non-jaw release (Talon type MQ). Lever bypasses the meter, but the meter may be removed with the bypass open. c) Horn bypass (option on residential sockets). Tangs on line and load connectors allow for jumper leads to be fitted over them before the meter is pulled. d) Manual bypass (K-4, K-5, K-7) uses separate “links”, which are clamped onto special studs before the meter is removed. K-7 also uses a “rotating link” type bypass. e) Other types not made by Talon include: slide links, screw type, and automatic circuit closers. | Meter Mounting Equipment for use in Texas and Oklahoma 3 135A Continuous Meter Mounting Equipment Residentialab, 4 & 5 terminal for 1 phase, 3 wire Cont. amp rating Service Connectors Line Load Dimensions (in.) W H D Hub opening Bypass Enclosure material Catalog number 135 OH/UG #14-2/0 8.0 11.7 3.6 1.25” Hub Inst None Steel UAT111-BG 8.0 11.7 3.6 RX Cl. Plate None Aluminum UAT131-XGF 8.0 11.7 3.6 RX Opening None Steel UAT111-0Gd 11.7 3.6 RX Opening Horn Steel UAT111-0PQGd 8.0 11.7 3.6 RX Cl. Plate None Steel UAT121-XGSPc #14-2/0 Residential - 135A - 4 & 5 Jaw - Ringless Approved for Brownsville Public Utilities Board 135 OH/UG #14-2/0 #14-2/0 Approved for Entergy and El Paso Electric Co. 135 OH/UG #14-2/0 #14-2/0 Approved for AEP West and Southwestern Public Service 135 OH/UG #14-2/0 #14-2/0 8.0 Approved for CenterPoint Power, AEP West and Entergy 135 OH/UG #14-2/0 #14-2/0 Approved for CPS (San Antonio Public Service) 135 OH #14-2/0 #14-2/0 8.0 11.7 3.6 1.25” Hub Inst Horn Steel UAT111-BPCC 135 UG #14-2/0 #14-2/0 8.0 11.7 3.6 Blank Horn Steel UAT121-PPCC a All units include a quad neutral. b 5th terminal kit for field installation: H659-0121. See accessories page in back. c Device has a ring-style cover. CenterPoint Power will provide the ring. d OH only for Entergy. UAT1X1 Knockouts (inches): 4 g: 1/4 L: 1/2, 3/4,1,1-1/4,1-1/2 N: 3/4,1,1-1/4,1-1/2, 2 R: 1,1-1/4,1-1/2, 2 RX: x2.750 HUB OP | Meter Mounting Equipment for use in Texas and Oklahoma UAT111-0PQG 200A Meter Mounting Equipment Residentialab, 4 & 5 terminal for 1 phase, 3 wire Cont. amp rating Service Connectors Line & Load Dimensions (in.) W H D a All units include a quad neutral. b 5th terminal kit for field installation: H659-0121. See accessories page in back. UAT317-0G UAT417-0G Bypass Enclosure material Catalog number Blank RX Cl. Plate None None Steel Steel UAS877-PG UAS877-XG RX Cl. Plate None Steel UAT427-XMWRe RX Opening 2” Hub Inst. None None Steel Steel UAT317-0G UAT317-DG RX Opening Blank None None Steel Steel UAT314-0G UAT417-PGe RX Cl. Plate None Steel UAT417-XGe RX Opening None Steel UAT417-0Ge RX Opening RX CL. Plate None None Steel Steel UAT327-0GSP UAT427-XGSPc RX Opening Blank RX Opening Blank Horn Horn Horn Horn Steel Steel Aluminum Aluminum UAT317-0PQG UAS877-PPZA UAT337-0PQG UAS837-PPG 2” Hub Inst. Blank Horn Horn Steel Steel UAT317-DPCC UAT817-XPCC Residential - 200A - 4 & 5 Jaw - Ringless Approved for Entergy and Texas-New Mexico Power (UG only) 200 UG #6-350 kcmil 13.0 14.0 5.1 200 OH/UG #6-350 kcmil 13.0 14.0 5.1 Approved for El Paso Electric and Entergy 200 OH/UG #6-350 kcmil 11.0 15.0 4.5 Approved for Entergy and ONCOR 200 OH #6-350 kcmil 8.0 15.0 4.5 200 OH #6-350 kcmil 8.0 15.0 4.5 Approved for Entergy 160 OH #6-350 kcmil 8.0 15.0 4.5 200 OH/UG #6-350 kcmil 11.0 15.0 4.5 Approved for Entergy, CoServ and El Paso Electric Co. 200 OH/UG #6-350 kcmil 11.0 15.0 4.5 Approved for Entergy, ONCOR, and Southwestern Public Service 200 OH/UG #6-350 kcmil 11.0 15.0 4.5 Approved for CenterPoint Power 200 OH #6-350 kcmil 8.0 15.0 4.5 200 OH/UG #6-350 kcmil 11.0 15.0 4.5 Approved for AEP West 200 OH #6-350 kcmil 8.0 15.0 4.5 200 UG #6-350 kcmil 13.0 14.0 5.1 200 OH #6-350 kcmil 8.0 15.0 4.5 200 UG #6-350 kcmil 13.0 14.0 5.1 Approved for CPS (San Antonio Public Service) 200 OH #6-350 kcmil 8.0 15.0 4.5 200 OH/UG #6-350 kcmil 13.0 15.0 5.1 Hub opening c Device has a ring style cover. CenterPoint Power will provide the ring. d Includes stainless steel latch and hasp. e OH only for Entergy. UAS877-PG UAT427-XGSP UAS877-PPZA UAT417-XG w/ H659-0121 installed Knockouts (inches): UAT4X7 UAT3X7 | UAT8X7 g: 1/4 A: 1/2 S: 1,1-1/4,1-1/2, 2, 2-1/2 AB: 1/4, 1/2, 7/8 AC: 1/4, 1/2 AD: 1-1/4, 1-1/2, 2, 2-1/2, 3 RX: x2.750 HUB OP Meter Mounting Equipment for use in Texas and Oklahoma 5 100/150A Position Meter Mounting Equipment Residential - 100/150A - 4 Jaw - Horizontal gang Residentialabc, Horizontal Gang, 4 terminal for 1 phase, 3 wire No. pos. Cont. amp rating Connectors Line Connectors Load Dimensions (in.) W H D Hub openinig 2 100 #6-350 kcmil #14-2/0 24.0 4.5 RX Opening 12.0 Catalog number Aluminum encl. Catalog number Steel encl. UA2311-0PQGd 3 100 #6-350 kcmil #14-2/0 32.0 12.0 4.5 RX Opening UA3311-0PQGd 4 100 #6-350 kcmil #14-2/0 40.0 12.0 4.5 RX Opening UA4311-0PQGd Approved for Brownsville and ONCOR (Aluminum only for Brownsville) 2 100 #6-350 kcmil #14-2/0 24.0 12.0 4.5 RX Opening UA2331-0G UA2311-0G 3 100 #6-350 kcmil #14-2/0 32.0 12.0 4.5 RX Opening UA3331-0G UA3311-0G 4 100 #6-350 kcmil #14-2/0 40.0 12.0 4.5 RX Opening UA4331-0G UA4311-0G Approved for ONCOR 2 150 #6-350 kcmil #6-350 kcmil 24.0 12.0 4.5 RX Opening UA2313-0G 3 150 #6-350 kcmil #6-350 kcmil 32.0 12.0 4.5 RX Opening UA3313-0G 4 150 #6-350 kcmil #6-350 kcmil 40.0 12.0 4.5 RX Opening UA4313-0G a Unit is supplied with a ground lugs. b All sockets are suitable for either overhead or underground feed. c 5th terminal kit for field installation: H659-0121. See accessories page in back. d Sockets with “QG” suffix are equipped with 2 ground lugs. UA2311/2313 UA2311-0PQG with H659-0121 installed UA3311/3313 UA4311/4313 Knockouts (inches): S: 6 | Meter Mounting Equipment for use in Texas and Oklahoma 1,1-1/4,1-1/2, 2, 2-1/2 AC: 1/4, 1/2 RX: x2.750 HUB OP 200A/Position Meter Mounting Equipment Residentialabc, Horizontal Gang, 4 & 5 terminal for 1 phase, 3 wire Cont. amp per pos. Connectors Line Dimensions (in.) W H D Hub opening Bypass Catalog number 2 200 #1/0-600 kcmil 3 200 #1/0-600 kcmil #6-350 kcmil 24.0 14.5 5.1 HD Opening None UA2717-YG #6-350 kcmil 32.0 14.5 5.1 HD Opening None UA3717-YG 4 200 5 200 (2) #1/0-600 kcmil #6-350 kcmil 43.0 14.5 5.1 HD Opening None UA4719-YG (2) #1/0-600 kcmil #6-350 kcmil 51.0 14.5 5.1 (2) HD Openings None UA5719-KG 6 200 (2) #1/0-600 kcmil #6-350 kcmil 59.0 14.5 5.1 (2) HD Openings None UA6719-KG Load Approved for AEP West and ONCOR 2 200 #1/0-600 kcmil #6-350 kcmil 24.0 14.5 5.1 HD Opening Horn UA2717-YPQGd 3 200 #1/0-600 kcmil #6-350 kcmil 32.0 14.5 5.1 HD Opening Horn UA3717-YPQGd 4 200 (2) #1/0-600 kcmil #6-350 kcmil 43.0 14.5 5.1 HD Opening Horn UA4719-YPQGd 5 200 (2) #1/0-600 kcmil #6-350 kcmil 51.0 14.5 5.1 (2) HD Openings Horn UA5719-KPQGd 6 200 (2) #1/0-600 kcmil #6-350 kcmil 59.0 14.5 5.1 (2) HD Openings Horn UA6719-KPQGd Approved for Brownsville Public Utilities Board (All devices have aluminum enclosures) 2 200 #1/0-600 kcmil #6-350 kcmil 24.0 14.5 5.1 HD Opening None UA2736-ZGF 3 200 #1/0-600 kcmil #6-350 kcmil 32.0 14.5 5.1 HD Opening None UA3737-ZGF 4 200 (2) #1/0-600 kcmil #6-350 kcmil 43.0 14.5 5.1 HD Opening None UA4739-ZGF 5 200 (2) #1/0-600 kcmil #6-350 kcmil 51.0 14.5 5.1 (2) HD Openings None UA5739-MGF 6 200 (2) #1/0-600 kcmil #6-350 kcmil 59.0 14.5 5.1 (2) HD Openings None UA6739-MGF Residential - 200A/position - 4 & 5 Jaw - Horizontal Gang No. pos. a All units are equipped with a ground lug. b All sockets are suitable for either overhead or underground feed. c 5th terminal kit for field installation: H659-0121. See accessories page in back. d Sockets with “QG” suffix have 2 ground lugs. UA27X6 UA2716-YG UA37X7 Knockouts (inches): X: UA47X9 UA57X9 | 1-1/4, 1-1/2, 2, 2-1/2 AC: 1/4, 1/2 AD: 1-1/4, 1-1/2, 2, 2-1/2, 3 HD: x4.281 HUB 0P UA67X9 Meter Mounting Equipment for use in Texas and Oklahoma 7 200A Meter Mounting Equipment Commercial/Industrial - 200A - 5 Jaw - Type CQ Commercial/Industrialabc, Type MQ, 5 & 7 terminal for 1 phase, 3 wire and 3 phase, 4 wire Cont. amp rating Service Connectors Line Dimensions (in.) W H D Hub opening No. of term. Bypass Catalog number 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 5 Lever 40205-01d 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7 Lever N40607-025 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 5 Lever 40605-025d #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7 None 30407-025e Load Approved for ONCOR 200 OH/UG a Type MQ bypass mechanism is lever-operated, non-jaw clamping. b Disconnect sleeves should not be used with these devices. c 5 terminal devices are not for use with 3 phase, 3 wire service. d Type MQ-5 devices have 5th terminal in the 9 o’clock position. e Ring style cover, no bypass lever. 4060X 3040X 40605-025 4020X Knockouts (inches): 8 | g: 1/4 A: 1/2 B: 1/2, 3/4 S: 1,1-1/4,1-1/2, 2, 2-1/2 AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 AF: 1, 1-1/2, 2, 2-1/2, 3 AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 RX: x2.750 HUB OP Meter Mounting Equipment for use in Texas and Oklahoma 40205-01 200A Meter Mounting Equipment Commercial/Industrialab, Type HQ, 4, 5 & 7 terminal for 1 phase, 3 wire, polyphase, 3 or 4 wire, Wye or Delta Service Connectors Line Load Dimensions (in.) W H D Hub opening No. of Term. Bypass Enclosure material Catalog number 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 5 Lever Steel 40005-01cd #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 4 Lever Steel 40404-025g 13.0 19.0 5.2 RX Cl. Plate 5 Lever Steel 40405-025cdg Approved for Entergy 200 OH/UG #6-350 kcmil Approved for Entergy, AEP West, and CoServ 200 OH/UG #6-350 kcmil #6-350 kcmil Approved for Xcel Energy, Entergy, AEP West and El Paso Electric Co. 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7 Lever Steel 40407-025g Approved for AEP West 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 4 Lever Steel 40804-01QGe 200 OH/UG #6-350 kcmil #6-350 kcmil 11.0 19.0 5.2 RX Cl. Plate 4 Lever Steel 40404-02QGe 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 5 Lever Steel 40405-02QGcde 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 5 Lever Steel 40005-01QGcde 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 13.0 5.2 RX Cl. Plate 7 Lever Steel 40407-02QGe 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 13.0 5.2 RX Opening 5 Lever Aluminum 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 13.0 5.2 RX Opening 7 Lever Aluminum 41405-015Fcd #6-350 kcmil 16.0 20.0 5.2 RX Cl. Plate 7 Lever Steel 9804-9142 Approved for CoServ and El Paso Electric Co. 200 OH/UG #4-600 kcmil Approved for Xcel Energy 41407-015F 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 5 Lever Steel 40405-02COf 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 5 Lever Steel 200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Opening 7 Lever Steel 40005-01Ff Approved for ONCOR 40007-01F 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 5 Lever Steel 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7 Lever Steel 10.0 17.5 5.2 2” Hub Inst. 7 Lever Steel 40027-02 13.0 19.0 5.2 RX Cl. Plate 7 Lever Steel 30407-025g 10.0 17.5 5.2 2” Hub Inst. 7 Lever Steel 40027-02CC 41405-025F Approved for Texas-New Mexico Power 200 OH #6-350 kcmil #6-350 kcmil Approved for CenterPoint Power and Entergy 200 OH/UG #6-350 kcmil #6-350 kcmil Approved for CPS (San Antonio Power) 200 OH #6-350 kcmil #6-350 kcmil Approved for Brownsville Public Utilities Board 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 5 Lever Aluminum 200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7 Lever Aluminum a Units are not suitable for use with disconnect sleeves. b Bypass mechanism is lever-operated, jaw pressure release with 100% bypass capacity. Knockouts (inches): g: 1/4 A: 1/2 B: 1/2, 3/4 S: 1, 1-1/4, 1-1/2, 2, 2-1/2 AC: 1/4, 1/2 AF: 1, 1-1/2, 2, 2-1/2, 3 AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 EE: 2, 2-1/2, 3 RX: x2.750 HUB OP Commercial/Industrial - 200A - 4, 5 & 7 Jaw - Type HQ Cont. amp rating 9804-8592cd 40407-025F 41407-025F c Devices have 5th terminal in the 6 o’clock position and are OK for use with 3 phase 3 wire service. d Neutral can be isolated by removing the ground strap. e Sockets with “QG” suffix are supplied with 2 ground lugs. f Devices have 5th Terminal in the 9 o’clock position and are not for use with 3 phase, 3 wire service. g OH only for Entergy. 9804-9142 9804/9142 | 404/414 410/400 Meter Mounting Equipment for use in Texas and Oklahoma 40407-025 9 320A Cont./400A Max. Meter Mounting Equipment Commercial - 320A cont./400A max. - 4 & 5 Jaw - Type HQ Commercialabc, Type HQ, 4 & 5 terminal for 1 phase, 3 wire & polyphase, 4 wire Cont. amp rating Service Connectors Line Dimensions (in.) W H D Load Hub opening No. of term. Bypass Enclosure material Catalog number 320 OH/UG #4-600 kcmil #4-600 kcmil 13.0 28.0 5.0 HD Cl. Plate 4 Lever Steel 47604-82g 320 OH/UG #4-600 kcmil (2) #6-350 kcmil 13.0 28.0 5.0 HD Cl. Plate 5 Lever Steel 47605-82g 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate 4 Lever Steel 47704-82g 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3” Hub Inst. 4 Lever Steel 47744-82g 320 OH/UG #4-600 kcmil (2) #6-350 kcmil 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48004-82g Approved for AEP West, Entergy, CenterPoint Power and Texas-New Mexico Power 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48104-02 320 OH/UG (2) 1/0-250kcmil (2) #6-350 kcmil 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48104-82 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48104-82WId 3/8-24 Stud 13.0 28.0 5.0 HD Cl. Plate 4 Lever Steel 47604-02QGh Approved for CoServ 320 OH/UG 3/8-24 Stud Approved for Entergy and Southwestern Public Service 320 OH/UG 3/8-24 Stud Approved for AEP West 320 OH/UG 3/8-24 Stud 3/8-24 Stud 13.0 28.0 5.0 HD Cl. Plate 5 Lever Aluminum 47605-A15Fe 320 OH/UG #4-600 kcmil (2) #6-300 kcmil 16.0 31.0 5.0 HD Cl. Plate 5 Lever Steel 49505-82 14.0 28.0 6.0 HD Opening 5 Lever Steel 47705-01FLe 1/2-20 Stud 14.0 28.0 6.0 HD Cl. Plate 4 Lever 47704-02f 3/8-24 Stud 20.0 34.0 6.0 HD Cl. Plate 5 Lever 48705-02FE 1/2-20 Stud 14.0 28.0 6.0 HD Opening 4 Lever Steel 47704-01NU 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48104-02CH Approved for Xcel Energy and El Paso Electric Company 320 OH/UG 1/2-20 Stud 1/2-20 Stud Approved for Texas-New Mexico Power 320 OH 1/2-20 Stud Approved for El Paso Electric 320 OH/UG 3/8-24 Stud Approved for ONCOR 320 OH/UG 1/2”-20 Stud Approved for Entergy 320 OH/UG 3/8-24 Stud Approved for CPS (San Antonio Public Service) 320 OH #4-600 kcmil #4-600 kcmil 13.0 25.0 5.0 3” Hub Inst. 4 Lever Steel 47644-82CC 320 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate 4 Lever Steel 48104-82CC Approved for Brownsville Public Utilities Board 320 OH/UG 1/2”-20 Stud 1/2-20 Stud 16.0 28.0 6.0 HD Opening 4 Lever Aluminum 41704-01 320 OH/UG 1/2”-20 Stud 1/2-20 Stud 20.0 34.0 6.0 HD Cl. Plate 5 Lever Aluminum 49105-02FL a All units have a lever operated, jaw pressure release bypass mechanism rated at 100%. b Disconnect sleeves should not be used with these devices. c Some devices do not include lugs, order separately. d Includes anti-inversion clip H59676. e 5 jaw devices are not for use with 3 phase, 4 wire service. f Overhead use only for TNP. g H60162 and H61300 lugs are also rated for (2) 250 kcmil. h OH only for Entergy. Knockouts (inches): A: B: Z: AC: AE: AG: EE: GG: HH: HD: 10 1/2 1/2, 3/4 1-1/2, 2, 2-1/2 1/4, 1/2 1/4, 1/2, 3/4, 1, 1-1/4 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 x4.281 HUB OP | 48X04 49504 4870X Meter Mounting Equipment for use in Texas and Oklahoma 4770X 476/485 320A Cont./400A Max. Meter Mounting Equipment Commercialabc, Type HQ, 7 terminal for 1 phase, 3 wire & polyphase, 4 wire Cont. amp rating Hub opening No. of term. Bypass Enclosure material Catalog number #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate 7 Lever Steel 47707-82d (2) #4-350 kcmil (2) #4-350 kcmil 20.0 34.0 6.0 HD Cl. Plate 7 Lever Steel 48707-82 Service 320 OH/UG 320 OH/UG Approved for Xcel Energy and El Paso Electric Company 320 OH/UG 1/2-20 Stud 1/2-20 Stud 14.0 28.0 6.0 HD Opening 7 Lever Steel 47707-01FLe 320 OH/UG 1/2-20 Stud 1/2-20 Stud 20.0 34.0 6.0 HD Cl. Plate 7 Lever Steel 44707-02FL Steel 48707-02 Approved for AEP West, CoServ, Entergy and Texas-New Mexico Power 320 OH/UG 3/8-24 Stud 3/8-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7 Lever 20.0 14.0 6.0 HD Cl. Plate 7 Lever 44707-02 20.0 34.0 6.0 HD Cl. Plate 7 Lever 48707-02FE 20.0 34.0 6.0 HD Cl. Plate 7 Lever Approved for Texas-New Mexico Power 320 OH/UG 1/2-20 Stud 1/2-20 Stud Approved for El Paso Electric and CenterPoint Power 320 OH/UG 3/8-24 Stud 3/8-24 Stud Approved for Brownsville Public Utilities Board 320 OH/UG 1/2-20 Stud 1/2-20 Stud Aluminum 49107-02FL a All units have a lever operated, jaw pressure release bypass mechanism rated at 100%. b Disconnect sleeves should not be used with these devices. c Some devices do not include lugs, order separately. d H60162 and H61300 lugs are also rated for (2) 250 kcmil. e OH only for Entergy. Commercial - 320A cont./400A max. - 7 Jaw - Type HQ Load Dimensions (in.) W H D Connectors Line Knockouts (inches): A: 1/2 B: 1/2, 3/4 Z: 1-1/2, 2, 2-1/2 AC: 1/4, 1/2 AE: 1/4, 1/2, 3/4, 1, 1-1/4 AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 EE: 2, 2-1/2, 3 GG: 2-1/2, 3, 3-1/2 HH: 2-1/2, 3, 3-1/2, 4 HD: x4.281 HUB OP 44707-02 shown w/ line lugs 4870X 4470X | 47707-01FL 4770X Meter Mounting Equipment for use in Texas and Oklahoma 11 400/480A Meter Mounting Equipment Residentiala, Type K4, 4 terminal for 1 phase, 3 wire Cont./Max, amp rating Type Service Connectors Line Load Dimensions (in.) W H D Hub opening Bypassb Encl. matl. Catalog numberd (2) #6-350 kcmil (2) #6-350 kcmil 18.0 36.0 6.1 HD Cl. Plate H56495 Steel 9810-8502 1/2-20 Stud 1/2-20 Stud 18.0 36.0 6.1 HD Cl. Plate H56495 Steel 9810-8523b Approved for El Paso Electric Company Residential - 400/480A - 4 Jaw - Type K4 400/400 K4UT OH/UG Approved for Entergy 480/600 K4UT OH/UG a Optional Manual Bypass H56495 available, normally for utility use only - 2 required. b Contact Houston Light & Power for connectors. Residential Type K-4 Overhead Parallel conductor 2 - H58853 2 - H56425 1 - H56732 Overhead Single conductor line Parallel conductor load 2 - H58852 2 - H56425 1 - H56476 1 - H56732 Underground Parallel conductor 2 - H58853 2 - H56732 1 - H56426 Underground Single conductor line Parallel conductor load 2 - H58852 2 - H56425 1 - H56476 1 - H56732 9810-8502 Overhead Single conductor 4 - H58852 2 - H56476 K4UT Knockouts (inches): B: 12 1/2, 3/4 GG: 2-1/2, 3, 3-1/2 HH: 2-1/2, 3, 3-1/2, 4 HD: x4, 281 HUB OP | Meter Mounting Equipment for use in Texas and Oklahoma Underground 4 - H58852 2 - H56476 400/480A Meter Mounting Equipment Residential/Commercial/Industriala, Type K-7, 7 terminal & 7 terminal Side Wired, polyphase, 3 or 4 wire, Wye or Delta Type Service Connectors Line Load Dimensions (in.) W H D Hub Opening Bypassb Encl. matl. Catalog number 400/400 K7T OH/UG 1/2-20 Stud 1/2-20 Stud 20.0 43.0 6.0 HD Cl. Plate H58888 Steel 9817-8512 480/600 K7T OH/UG 1/2-20 Stud 1/2-20 Stud 20.0 43.0 6.0 (2) HD Cl. Plates H58888 Steel 9817-9504 a All units are UL listed. b Optional Manual Bypass H58888 available, normally for utility use only (3 required). Residential Type K-7 Overhead Single conductor 8 - H56476 Overhead Parallel conductor 8 - H56732 Overhead Single and triple load feed 4 - H56476 4- H68752-1 Residential/Commercial/Industrial - 400/480A - 7 Jaw - Type K-7 Cont./Max. amp rating 9810-8502 K7T-400 Amp Underground Single conductor 3 - H58852 5 - H56476 Underground Single conductor line Triple conductor load 3 - H58852 1 - H56476 4 - H68752-1 Underground Parallel conductor 3 - H58853 5 - H56732 Knockouts (inches): B: | K7T-600 Amp 1/2, 3/4 HH: 2-1/2, 3, 3-1/2, 4 HD: x4, 281 HUB OP Meter Mounting Equipment for use in Texas and Oklahoma 13 100/200A Meter Mounting Equipment Residential - 100/200A - 4 & 5 Jaw - Meter Mains Residentiala, Meter Main 4 and 5 terminal for 1 phase, 3 wire Connectors Line Load Dimensions (in.) W H D Hub opening Main breaker No. term. Bypass Cover style Catalog number OH/UG #6-250 kcmil #2-1/0 CU, 2/0 AL 18.5 17.0 5.1 RX Cl. Plate 125A Inst. 5 Horn Ringless LGMM0202B1125RJBX be 150 OH/UG #6-250 kcmil #1-300 kcmil 18.5 17.0 5.1 RX Cl. Plate 150A Inst. 5 Horn Ringless LGMM0202B1150RJBX be 200 OH/UG #6-250 kcmil #1-300 kcmil 18.5 17.0 5.1 RX Cl. Plate 200A Inst. 5 Horn Ringless LGMM0202B1200RJBX be 150 OH/UG #6-250 kcmil #1-300 kcmil 16.0 17.0 5.1 RX Cl. Plate 150A Inst. 4 None Ring LGMM0202B1150 200 OH/UG #6-250 kcmil #1-300 kcmil 16.0 17.0 5.1 RX Cl. Plate 200A Inst. 4 None Ring LGMM0202B1200 see breaker rating 11.6 28.0 5.2 RX Cl. Plate 150-200A Prov. 4 None Ringless UAB417-XPG see breaker rating 13.1 25.1 5.2 Blank Top 150-200A Prov. 4 None Ringless UAB877-PG #4-250 kcmil 14.0 30.0 5.0 RX Cl. Plate MBK200 4 None Ringless LG0816B1200RCT 27.0 29.0 6.0 HD-top HD-bot QN2200H 4 Lever Ringless LG0816B1400RLT 40.1 6.5 HD Cl. Plate (2) Prov. fpr QN or QP type 5 Lever Ringless LG0404L1400RLM Rating Service 125 Approved for Texas-New Mexico Power 200 OH/UG #6-350 kcmil Approved for Entergy 200 UG-SW #6-350 kcmil Approved for El Paso Electric 200 OH/UG #4-250 kcmil Approved for AEP and Xcel Energy 320 OH/UG #1-600 kcmil or (2) 1/0250 #1-300 kcmil Approved for El Paso Electric and Xcel Energy 320 OH/UG #4-600 kcmil or (2) 1/0360 see breaker rating 30.1 a All units are UL listed. b 5th terminal factory installed. c 5th terminal for field installation: H659-0121. d UAB111-0PCH has a provision for a 125 amp max. circuit breaker. See breaker table for details. e Breaker factory installed. See breaker table for replacement circuit breakers. See accessories page in back. UAB4 Knockouts (inches): Breaker table Amps Circuit breaker 100 Q2100 125 Q2125 150 QN2150 200 QN2200 s: UAB317 200 14 QJ22B200 | UAB417-XG LGMM0202B1200 Meter Mounting Equipment for use in Texas and Oklahoma g: A: C: S: Z: DD: RX: 5/16 on UAB4 5/16,1/2 on UAB8 1/4 1/2 1/2, 3/4, 1 1,1-1/4,1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 1-1/4,1-1/2, 2, 2-1/2, 3 x2.750 HUB OP Type PTS Transformer-Rated Meter Mounting Equipment with Test Switch Provision Product Schedule 465 PTS6: 6 Jaw PTS8: 8 Jaw Ringless - Split Cover Steel Aluminum Ring Type - Split Cover Steel Aluminum Dimensions L W D Cont. Amp. Hub Rating Opening Terminal Wire Range Current Potential 9837-8200 9837-8201 9837-8202 9837-8203 9837-8204 9837-8205 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14 9837-8210 9837-8211 9837-8212 9837-8213 9837-8214 9837-8215 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14 9837-8220 9837-8221 9837-8222 9837-8223 9837-8224 9837-8225 20.0 12.0 4.5 20 1.25” Hub Inst. #4-14 #8-14 9837-8230 9837-8231 9837-8232 9837-8233 9837-8234 9837-8235 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14 9837-8240 9837-8241 9837-8242 9837-8243 9837-8244 9837-8245 20.0 12.0 4.5 20 RX Opening #4-14 #8-14 9837-8400 9837-8401 9837-8402 9837-8403 9837-8404 9837-8405 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14 9837-8410 9837-8411 9837-8412 9837-8413 9837-8414 9837-8415 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14 9837-8420 9837-8421 9837-8422 9837-8423 9837-8424 9837-8425 20.0 12.0 4.5 20 1.25” Hub Inst. #4-14 #8-14 9837-8430 9837-8431 9837-8432 9837-8433 9837-8434 9837-8435 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14 9837-8440 9837-8441 9837-8442 9837-8443 9837-8444 9837-8445 20.0 12.0 4.5 20 RX Opening #4-14 #8-14 9837-8500 9837-8501 9837-8502 9837-8503 9837-8504 9837-8505 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14 9837-8510 PTS13: 13 9837-8520 Jaw 9837-8530 9837-8511 9837-8512 9837-8513 9837-8514 9837-8515 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14 9837-8521 9837-8522 9837-8523 9837-8524 9837-8525 20.0 12.0 4.5 20 1.25” Hub Inst. #4-14 #8-14 9837-8531 9837-8532 9837-8533 9837-8534 9837-8535 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14 9837-8540 9837-8541 9837-8542 9837-8543 9837-8544 9837-8545 20.0 12.0 4.5 20 RX Opening #8-14 #4-14 General Information Capacity: 20 amperes, 600 volts a.c. Application: Transformer-rated applications. Available with or without test switch and pre-wiring. Enclosures: 14-gauge .063 aluminum or 16-gauge galvannealed steel suitable for indoor or outdoor installation. Terminals: Set screw type. Hubs: Interchangeable 1”, 1-1/4”, 1-1/2” Finish: Aluminum unpainted unless specified. Steel enclosures have gray polyester powder coat finish. Test Switches: Standard 6 and 10 pole, 480-volt rated switches are available from stock. Special switches available upon request. Type PTS Transformer-Rated Meter Mounting Equipment with Test Switch Provision Catalog Numbers Socket Ringless - Solid Cover Type Steel Aluminum Common Features n 20A continuous rated n Ground lug available n Steel or aluminum construction n Split or solid cover construction n OH and UG capabilities n 600V rated n Spacing for multiple test switch configurations n Customized test switch and wiring Consult the factory for other available options such as, but not limited to alternate enclosure and hasp material, kearnaloxed terminals, enclosures with special KO configurations, pre-wired units, test switch specifications and special labeling. Note - The following devices are approved for Brownsville Public Utilities Board: 9837-0916 (20A, 6T, prewired) 9837-0917 (20A, 8T, prewired) 9837-0918 (20A, 13T, prewired) | Knockouts (inches): B: 1/2, 3/4 Q: 1, 1-1/4, 1-1/2 AC: 1/4, 1/2 RX: x2.750 HUB OP Meter Mounting Equipment for use in Texas and Oklahoma 15 Type HQ-T Transformer-Rated Meter Mounting Equipment Type HQ-T Transformer-Rated Meter Mounting Equipment Product Schedule 467 Catalog Numbers Removable Handle Removable Handle Dimensions (in.) W H D Continuous Amp. Rating Hub Opening Terminal Wire Range Current Term. Potential Term. 9804-8544 9804-8548 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14 9804-8482 9804-8485 17.5 10.0 5.0 80 1” Hub Inst. #4-14 #8-14 9804-8483 9804-8486 17.5 10.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 9804-8542 9804-8546 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14 9804-8419 9804-8456a 17.5 10.0 5.0 80 1” Hub Inst. #4-14 #8-14 9804-8422 9804-8459 17.5 10.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 9804-8543 9804-8547 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14 HQ-13T: 9804-8420 13 Jaw 9804-8423 9804-8457 17.5 10.0 5.0 80 1” Hub Inst. #4-14 #8-14 9804-8460 17.5 10.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 9804-8426 9804-8463 17.5 10.0 5.0 80 1.50” Hub Inst. #4-14 #8-14 Socket Type HQ-6T: 6 Jaw HQ-8T: 8 Jaw a Approved for Fayetteville PWC. General Information Capacity: 80 ampere continuous, 600 volts a.c. Application: 6 terminal, single phase 2 or 3 wire; 8 terminal, 2 or 3 phase, 3 wire, HQ-13T - 3 phase, 4 wire wye or 4 wire delta. For use with transformer-rated Class 10 or 20 meters. May also be used on self-contained applications up to 80 ampere load. Enclosures: Constructed of 16 gauge galvannealed steel with polyester powder coat finish. Also available in 12 gauge aluminum upon request. Block Assembly: Glass fiber reinforced polyester. High strength, arc and track resistant. Bypass: Lever-Operated Jaw Release - Moving lever up closes bypass, providing positive short circuiting of the current circuits and releases jaw pressure on the meter current terminals providing easy removal of the meter. Also available is a removable bypass handle which allows a solid cover, #37943-2 for HQ-T or #54199-2 for HQ-TS, to be placed on the box with the bypass closed when it is necessary to remove the meter for in-shop repair or testing. Bypass capacity: 80 amp continuous. Terminals: Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14. Potential terminals will accommodate from #8 to #14. Hubs: Cover plate or single removable gasketless hubs are interchangeable. UL: All sockets shown are UL approved. Safety Shield: Track resistant polycarbonate transparent safety shield provides liberal insulation between potential jaws and terminals and protection from accidental shorts and shocks. Common Features n Clamping jaw lever bypass n 80A continuous rated n Ground lug available n Screw type terminals with pressure plate n Steel or aluminum construction n Glass filled polyester block construction n 200% rated bypass n Overhead and underground capabilities n 600V rated Consult the factory for other available options such as, but not limited to alternate enclosure and hasp material, kearnaloxed terminals, enclosures with special KO configurations and special labeling. 16 | Meter Mounting Equipment for use in Texas and Oklahoma Knockouts (inches): g: 1/4 B: 1/2, 3/4 S: 1, 1-1/4, 1-1/2, 2, 2-1/2 AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 RX: x2.750 HUB OP Connections Product Schedule 467 Form 6S Form 8S HQ-8T Form 9S Form 10S Type HQ-T Transformer-Rated Meter Mounting Equipment HQ-13T HQ-6T Form 5S Form 4S | Form 3S (2 Wire CT) Meter Mounting Equipment for use in Texas and Oklahoma Form 3S (3 Wire CT) 17 Type HQ-TS Transformer-Rated Meter Mounting Equipment with Test Switch Provision Type HQ-TS Transformer-Rated Meter Mounting Equipment with Test Switch Provision Product Schedule 469 Socket Type Catalog Numbers Removable Handle 9804-8557 9804-8561 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14 HQ-6T: 6 Jaw 9804-8494 9804-8497 19.0 13.0 5.0 80 1” Hub Inst. #4-14 #8-14 HQ-8T: 8 Jaw HQ-13T: 13 Jaw Solid Handle Dimensions L W D 9804-8495 9804-8498 19.0 13.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 9804-8496 9804-8499 19.0 13.0 5.0 80 RX Opening #4-14 #8-14 9804-8559 9804-8563 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14 9804-8518 9804-8521 19.0 13.0 5.0 80 1” Hub Inst. #4-14 #8-14 9804-8519 9804-8522 19.0 13.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 9804-8669 9804-8523 19.0 13.0 5.0 80 RX Opening #4-14 #8-14 9804-8560 9804-8564 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14 9804-8530 9804-8533 19.0 13.0 5.0 80 1” Hub Inst. #4-14 #8-14 - 9804-8532 19.0 13.0 5.0 80 RX Opening #4-14 #8-14 9804-8531 9804-8534 19.0 13.0 5.0 80 1.25” Hub Inst. #4-14 #8-14 General Information Capacity: 80 ampere continuous, 600 volts a.c. Application: HQ-6TS - Single phase, 2 or 3 wire, HQ-8TS - 2 or 3 phase, 3 wire HQ-13TS - 3 phase, 4 wire wye or 4 wire delta For use with transformer-rated Class 10 or Class 20 meters and appropriate meter test switch. Enclosures: Ringless. Constructed of 16 gauge galvannealed steel with baked enamel finish for indoor or outdoor installation. Also available in 12 gauge aluminum upon request. Box is adequately dimensioned and has mounting holes provided for test switch installation. Block Assembly: Glass fiber reinforced polyester. High strength, arc and track resistant. Bypass: Jaw release type. Moving lever up closes bypass providing positive short circuiting of the current circuits and releases jaw pressure on the meter current terminals providing easy removal of the meter. Also available is a removable bypass handle which allows a solid cover (#54199-2) to be placed on the box with the bypass closed when it is necessary to remove the meter for in-shop repair or testing. Bypass capacity: 80 amp continuous. Terminals: Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14 copper or aluminum. Potential terminals will accommodate conductors from #8 to #14 copper or aluminum. Hubs: Available with cover plate or single removable gasketless hub. Hubs and cover plate are interchangeable. UL: All sockets shown are UL approved. Common Features n Clamping jaw lever bypass n 80A continuous rated n Ground lug available n Screw type terminals with pressure plate n Steel or aluminum construction n Glass filled polyester block construction n 200% rated bypass n Overhead and underground capabilities n 600V rated n Spacing for multiple test switch configurations Consult the factory for other available options such as, but not limited to alternate enclosure and hasp material, kearnaloxed terminals, enclosures with special KO configurations and special labeling. 18 Terminal Wire Range Current Potential Continuous Hub Ampere Rating Opening | Meter Mounting Equipment for use in Texas and Oklahoma Knockouts (inches): g: 1/4 A: 1/2 AF: 1, 1-1/2, 2, 2-1/2, 3 AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 RX: x2.750 HUB OP Connections Product Schedule 469 General Information (continued) Track resistant polycarbonate transparent insulating safety shield provides protection from accidental shorts and shocks. Potential terminals are mounted in the safety shield for ease of wiring and testing. Test Switch Mounting: An insulated mounting bracket is included below the meter socket for the customer installation of a standard test switch. Holes are provided for No. 10-32 mounting screws. Knockouts: All box enclosures have one 1”, 1 1/4”, 1 1/2” concentric knockout in the back, and three 1”, 1 1/4”, 1 1/2” concentric knockouts in the bottom. There are no knockouts in the sides. In addition, there are one 1/4” knockout and one 1/2”, 3/4” concentric knockout in the bottom. HQ-13TS Form 6S Form 8S HQ-7TS Form 9S Form 10S Type HQ-TS Transformer-Rated Meter Mounting Equipment with Test Switch Provision Safety Shield: HQ-8TS Form 7S Form 24S Form 5S HQ-6TS Form 4S Form 3S (2 Wire CT) | Form 3S (3 Wire CT) Meter Mounting Equipment for use in Texas and Oklahoma 19 Air Conditioning Disconnects Fused and Non-fused Air Conditioning Disconnects - Fused & Non-Fused Features: Flexibility L 30-60 amperes L 240 volts A.C. L Padlock provisions L Horsepower rated L 10,000 A.I.C. L New models available with internal GFCI receptacle L Removable door L Ample wiring space Rugged Durability L Noryl® thermoplastic and powder coated G90 steel enclosures are corrosion resistant and extremely durable giving long maintenance free service L Copper conductors L Raised mounting embosses Steel AC Disconnects Ampere rating Disconnect type Catalog number Horse power rating Dimensions (inches) H W D 30 Fused pullout LF2030 3 7.3 5.0 2.1 60 Fused pullout LF2060 10 8.0 5.0 2.1 60 Non-fused pullout LN2060 10 7.3 5.0 2.1 60 Non-automatic switch LNAS2060 10 7.3 5.0 2.1 Plastic AC Disconnects Ampere rating Disconnect type Catalog number Horse power rating Dimensions (inches) H W D 30 Fused pullout LF2030PL 3 8.0 5.3 3.1 60 Fused pullout LF2060PL 10 8.0 5.3 3.1 60 Non-fused pullout LN2060PL 10 7.3 5.0 2.1 60 Non-fused pullout LN2060PLX 10 8.0 6.0 5.8 Steel AC Disconnects with 15 Amp GFCI Receptacle Ampere rating Disconnect type Catalog number Horse power rating Dimensions (inches) H W D 30 Fused pullout LF2030GFCI 3 9.0 6.1 5.1 60 Fused pullout LF2060GFCI 10 9.0 6.1 5.1 60 Non-fused pullout LN2060GFCI 10 7.1 5.8 5.1 60 Non-automatic switch LNAS2060GFCI 10 7.1 5.8 5.1 Wire Range Table Copper 20 Aluminum Connector Solid Stranded Solid Stranded Line #14-8 #14-3 #12-8 #12-3 Load #14-8 #14-3 #12-8 #12-3 Neutral #12-8 #12-2 #12-8 #12-2 Equip. grnd. #12-8 #12-2 #12-8 #12-2 | Meter Mounting Equipment for use in Texas and Oklahoma Spa Panels For use as spa/hot tub service disconnect Features: L UL Listed installed, 2-pole 50A or 60A GFCI breaker for 240V ground fault protection L NEMA Type 3R outdoor enclosure L 2 extra spaces (4 circuits manimum) for additional circuit breakers L 125 Amp rated interior L Factory installed 5 position ground bar L Closure plate included L Compact enclosure size L Convenient standard package of 1 L Uses reliable Siemens circuit breakers L Factory Dimensions (inches) H W D Catalog number 50A 12.3 6.0 4.5 LGSPA50 60A 12.3 6.0 4.5 LGSPA60 Spa Panels - 50A and 60A 2-Pole GFCI breaker 12-1/4-” dead front hub cover plate included enclosure | 6” Meter Mounting Equipment for use in Texas and Oklahoma 21 Connector Lugs H55890 3/8” Stud H55890-1 3/8” Stud H56734 1/2” Stud H37892 1/2” Stud H57606-K 3/8” Stud H56476 1/2” Stud H60162 1/2” Stud H61300 1/2” Stud H58022 3/8” Stud H56732 1/2” Stud H56732-1 1/2” Stud H56732-2 (2) #4-350 kcmil 3/8” Stud H56732-M 1/2” Stud H68752-1 1/2” Stud H56426 1/2” Stud H56477 #3/0-800 kcmil 1/2” Stud H56425 1/2” Stud H56425-M 1/2” Stud H58852 1/2” Stud H56733 1/2” Stud H56427 1/2” Stud H56427-M 1/2” Stud H58853 1/2” Stud H59299-1 1/2” Stud Connector Lugs #6-350 kcmil #6-350 kcmil (2) #6-250 kcmil (2) #4-500 kcmil (2) #6-350 kcmil (2) #6-350 kcmil 22 | #6-350 kcmil #3/0-800 kcmil (2) #4-350 kcmil (3) #6-250 kcmil (2) #4-500 kcmil (2) #4-500 kcmil #6-250 kcmil (1) #4-600 kcmil [or] (2) #1/0-250 kcmil (2) #4-350 kcmil (4) #6-350 kcmil #3/0-800 kcmil (2) #6-350 kcmil Meter Mounting Equipment for use in Texas and Oklahoma #4-500 kcmil (1) #4-600 kcmil [or] (2) #1/0-250 kcmil #3/0-800 kcmil Connector Lugs Pressure type lugs for Talon’s stud type meter mounting devices are made of 6061-T6 aluminum to provide high strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug. All Talon lugs are listed with Underwriters Laboratories. Pressure lug connectors for meter mounting devices Device type Antirotation feature No #6-350 kcmil 13/32” 9/16” Hex 2-1/4 1-1/8 1-1/4 H55890 HQ-4S No #6-350 kcmil 13/32” 5/16” Allen 2-1/4 1-1/8 1-1/4 H55890-1 Conductor size Stud opening Pressure screw head Dimensions* (inches) L W H Catalog number No #6-350 kcmil 13/32” 3/8” Allen 2-1/4 1-1/8 1-1/4 H57606-K No (2) #6-250 kcmil 13/32” 5/16” Allen 2-3/16 1-5/8 1-3/16 H58022 HQ-4D No #4-500 kcmil 9/16” 3/8” Allen 2-13/16 1-1/2 1-9/16 H37892 HQ-5DM Yes (1) #4-600 kcmil 9/16” 1/2” Allen 2-13/16 1-3/8 1-13/16 H60162 No (2) #1/0-250 kcmil 9/16” 1/2” Allen 2-13/16 1-3/8 1-13/16 H61300 HQ-7D HQ-7DF Connector Lugs HQ-5 S HQ-7S or K-4,5,7 No (2) #6-350 kcmil 9/16” 5/16” Allen 2-7/8 1-57/64 1-1/4 H56425 K-4,5,7 No (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-1/16 1-9/16 H56425-M K-4 No (4) #6-350 kcmil 9/16” 5/16” Allen 2-7/8 3-15/16 1-1/4 H56426 K-4,5,7 Yes (2) #6-350 kcmil 9/16” 5/16” Allen 4-15/16 1-1/8 2-1/16 H56427 K-4,5,7 Yes (2) #2-500 kcmil 9/16” 3/8” Allen 4-1/4 1-1/8 1-13/16 H56427-M K-5,7 Yes #3/0-800 kcmil 9/16” 1/2” Allen 3-1/4 1-5/16 1-13/16 H56476 K-4,5,7 Yes #3/0-800 kcmil 9/16” 1/2” Allen 3-1/4 1-5/16 1-13/16 H56477 K-5,7 No (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-5/32 1-9/16 H56490 K-5,7 Yes (2) #4-350 kcmil 9/16” 5/16” Allen 2-7/8 1-59/64 1-1/4 H56732 K-5,7 No (2) #4-350 kcmil 9/16” 5/16” Allen 2-7/8 1-59/64 1-1/4 H56732-1 K-5,7 Yes (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-5/32 1-13/16 H56732-M K-4,5,7 Yes #3/0-800 kcmil 9/16” 1/2” Allen 4-3/16 1-3/4 2-3/8 H56733 K-4,5,7 (Grd.) No #6-250 kcmil 9/16” 5/16” Allen 2-9/16 1-9/32 1-3/16 H56734 K-4,5,7 Yes #3/0-800 kcmil 9/16” 1/2” Allen 3-15/16 1-3/4 1-13/16 H58852 K-4,5,7 Yes (2) #6-350 kcmil 9/16” 5/16” Allen 3-15/16 1-1/8 1-1/2 H58853 K-4,5,7 Yes (3) #6-250 kcmil 9/16” 5/16” Allen 2-7/8 2-31/64 1-7/16 H68752-1 K-4 extender Yes 1/2-20 x 1-7/8” Stud 9/16” None 4-1/4 1-1/4 2-3/8 H59299-1 Lug Extender Device type Stud opening Stud size Dimensions (inches) W H D Catalog number K-4 9/16” 1/2-20 x 1-7/8” 4-1/4 2-3/8 H59299-1** 1-1/4 * Dimensions do not include height of pressure screw with conductor installed. ** Includes nut and washer assembly and washer. H W | L Meter Mounting Equipment for use in Texas and Oklahoma 23 Accessories Sealing rings Removable hub kits Conduit Size (inches) Catalog number Description Accessories RX type hubs small Removable hub 1 H38596-2 1-1/4 H38597-2 1-1/2 H38598-2 2 H38599-2 2-1/2 H38600-2 Cover plate - steel H38595-1 Cover plate - aluminum H38595-2 Stainless Steel Snap Type Stainless Steel Screw Type H54602 H9738-8002 HD Type Hubs Large Cover plate 3 H56856-2 3-1/2 H56857-2 4 H56858-2 Cover plate - steel H56933 Cover plate - aluminum H56933-1 Accessories Accessories | Description Catalog number HQ isolated neutral kit H64685-1* *Includes neutral and isolation block Description 24 Catalog number Catalog number Insulated 5th terminal kit - Type AS, AT only H659-0120 Grounded 5th terminal kit - Type AS, AT only H659-0121 Neutral isolation kit for HQ H64690-1* *Isolates existing neutral HQ 5th terminal kit - 9:00 w/o wire H35815-2 HQ 5th terminal kit - 9:00 w/ wire H35815-3 HQ 5th teminal kit - 9:00 w/ 9” lead *For use with side wired devices only. H35815-5* Large to small adaptor steel HD to RX H9747-1113 Large to small adaptor aluminum HD to RX H9747-1112 Black plastic meter opening cover H39968 Clear plastic meter opening cover (with plug-in feet) H659-0162 Meter Mounting Equipment for use in Texas and Oklahoma Insulated Jumper H36479 Add-on grounding lug for HQ/HQU H55303 K-7 Rotary Bypass 600 Amp rated H69623 K-7 Rake Type Bypass 600 Amp rated, temp use only H58888 K-4 Rake Type Bypass 600 Amp rated, temp use only H56495 Terms of Sale, Meter Mounting Device Applications Terms of sale Transportation Charges: Prices listed are F.O.B. factory with freight prepaid and allowed on all shipments of orders of $1,000 net or more for single shipments to one location. Cancellation: Orders accepted by the factory can be cancelled only with the factory’s consent and upon payment to the seller of reasonable charges incurred by the seller which will indemnify the seller against loss. Returns: Goods may not be returned to Talon without written authorization from the factory. A minimum 20% restocking charge will be applicable on all returned goods. Credit will be given only for current production items in unopened cartons. All transportation charges paid by Talon will be deducted from such credit. Terms: Standard/Stock Products: 2% 10th net 25th for invoices dated the 1st through the 15th of the month. 2% 25th net 10th for invoices dated the 16th through the 31st of the month. Meter Mounting Device Applications Electrical service 1-phase 3-phase, 3 wire or network Socket type Standard socket Catalog number 4 jaw 100A AT-1 4 jaw 200A AT-3, AT-4, MQ-4, HQ-4 2SE 4 jaw 320A HQ-4S, HQ-4D Self-contained, bolt-in 2K K4-400/480A K-4, K-4UT Transformer-rated, 2 wire 3S! 5 jaw 20A HQ-6T, HQ-6TS, PTS-6 Transformer-rated, 3 wire 4S! 6 jaw 20A HQ-6T, HQ-6TS 12S 5 jaw 100A MQ-5, HQ-5 12S 5 jaw 200A MQ-5, HQ-5 12SE 5 jaw 320A HQ-5SWT, HQ-5D Self contained bolt-in 12K K-5 480/600A K-5 Transformer-rated 5S 8 jaw 20A HQ-8T, HQ-8TS, PTS-8 7 jaw 100/200/320A MQ-7, HW-7 K-7 480/600A K-7, K-7T 13 jaw 20A HQ-13T, HQ-13TS, PTS-13 Service type Meter form Self-contained, 3 wire Self-contained 3-phase, 4 wire 2S Terms of sale - meter mounting device applications Minimum Billing: $100 net plus transportation charges. 14S Self-contained 15S 16S 14K Wye Self-contained, bolt-in 15K 16K 6S Transformer-rated 8S 9S or Delta | Meter Mounting Equipment for use in Texas and Oklahoma 25 Notes: 26 | Meter Mounting Equipment for use in Texas and Oklahoma Notes: | Meter Mounting Equipment for use in Texas and Oklahoma 27 Notes: 28 | Meter Mounting Equipment for use in Texas and Oklahoma Represented by: JD Martin Inc. 1801 Royal Lane, Suite 100 Dallas, TX 75229 Phone: (972) 277-5600 Talon Meter Mounting Devices Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 www.talonmetering.com Subject to change without prior notice Order No.: RPSA-LG016-1211 All rights reserved Printed in USA © 2011 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
40404-025 价格&库存

很抱歉,暂时无法提供与“40404-025”相匹配的价格&库存,您可以联系我们找货

免费人工找货