Selection and application guide
For use in Texas and Oklahoma
Meter Mounting Equipment
www.talonmetering.com
Meter Mounting Equipment
Table of Contents
Service
Rating
Positions
Terminals
Page
Introduction and General Information
-
-
-
2-3
Residential, 1 phase, 3 wire
135A
1
4&5
4
Residential, 1 phase, 3 wire
200A
1
4&5
5
Residential, 1 phase, 3 wire, Horizontal Gang
100/150A
2-4
4
6
Residential, 1 phase, 3 wire, Horizontal Gang
200A
2-6
4&5
7
Commercial/Industrial, 1 and 3 phase, 3 wire, Type MQ
200A
1
5&7
8
Commercial/Industrial, 1 phase, 3 wire,
Polyphase, 3 or 4 wire
200A
1
4, 5, & 7
9
Commercial/Industrial, 1 phase, 3 wire, Polyphase, 4 wire
320A
1
4&5
10
Commercial/Industrial, 1 phase, 3 wire, Polyphase, 4 wire
320A
1
7
11
Residential, 1 phase, 3 wire
400/480A
1
4
12
Residential/Commercial/Industrial, Polyphase, 3 or 4 wire
400/480A
1
7
13
Residential, Meter Main, 1 phase, 3 wire
100/200A
1
4&5
14
Type PTS, Transformer-Rated with Test Switch Provision
-
-
-
15
Type HQ-T, Transformer-Rated
-
-
-
16
Type HQ-TS, Transformer-Rated with Test Switch Provision
-
-
-
18
Air Conditioning Disconnects
-
-
-
20
Spa Panels
-
-
-
21
Connector lugs
-
-
-
22-23
Accessories
-
-
-
24
Terms of Sale, Meter Mounting Device Applications
-
-
-
25
Represented by:
JD Martin Inc.
1801 Royal Lane, Suite 100
Dallas, TX 75229
Phone: (972) 277-5600
|
Meter Mounting Equipment for use in Texas and Oklahoma
1
Meter Mounting Equipment
The standard for quality
For more than 50 years, meter mounting devices that are now manufactured
under the Talon Brand, have been known throughout the industry for innovation
and quality. From our proprietary K-Base to our heavy duty HQ lever bypass
socket, Talon products are known throughout the industry for innovation and
quality. Talon meter sockets are built for safety, ease of installation, and long
term quality. That’s why we use stainless steel hardware, polyester powder coat
paint for long lasting protection, and Type G-90 galvanized steel or 3003 grade
aluminum for all of our enclosures. It’s also why we use an all-copper current
path in our commercial sockets. All of this adds up to why utilities, OEM’s, and
contractors recognize Talon meter mounting devices across the country as the
leader in design, quality, and workmanship. Quality is the reason many utilities
and electricians specify Talon products.
Talon products - the standard for quality and design.
General information
Materials:
16 gauge, galvanized steel, G-90
14 gauge, galvanized steel, G-90
14 gauge, aluminum
12 gauge, aluminum
Enclosures:
NEMA 3R
Finish:
Steel - Light gray, baked on powder
polyester
Aluminum - Mill finish
2
|
Latches:
All swing latches are stainless steel
Block material:
AS/AT, MQ, HQ, K-4 and K-7 - Glass
reinforced polyester
Terminals:
AS/AT - Tin-plated aluminum extrusions
6061-T6
MQ, HQ, - Tin-plated copper
HQ-5 block assembly
The standard for quality.
Standards:
Products cataloged herein meet or
exceed the following standards:
UL 486B, UL 414, NEMA 250,
ANSI C12.7 Florida Meter Group
requirements
Voltage:
All devices are rated at 600V AC
Type K-4 rated at 300V AC
Meter Mounting Equipment for use in Texas and Oklahoma
Meter Mounting Equipment
Meter socket terminology
Maximum and continuous ampacity
UL and NEMA standards allow most electrical devices to
be tested at one amp level (“continuous”), then allowed
125% rating as “maximum”. For example, a “400 Amp”
socket may either mean 400 Amps continuous (K-4) or
400A Max, 320A continuous which is also made by most
competitors.
Wire sizes - ampacity
Connectors accept a fairly wide variety of wire sizes. \On
the AT socket, a 350 MCM connector accepts conductors
from #6 up to 350 MCM. The NEC specifies the ampacity
of each wire size and type, also taking into account how
the wire is installed in conduit.
Lay-in and stud terminals
Lay-in terminals are fixed and may not be modified in
the field to accept other wire sizes or parallel conductors.
Stud terminals accept either lugs (see Product Schedule
497) or compression fittings (not available from Talon).
Common uses for studs include where the field wiring
may be either single or parallel. Terminals may be mixed
on the line and load sides, e.g. stud on the line and lay-in
on the load side.
Ringless/Ring style
Ring-type is an older, vanishing concept requiring a
sealing ring. Talon recently added tooling to build this
type of socket for the few remaining utilities that require
them. In ringless design, the seal is made not on a sealing
ring but using the cover and “swing latch” as the point of
sealing.
Overhead/Underground
Sockets for UG service are usually wider in order to provide
space for the conductors to loop around the block to
the top connectors. Since more material is required in
the enclosure, UG sockets are more expensive than OH
sockets. Quite popular are combination units (OH/UG)
which may be used in either service, and require a cover
plate if used with UG feed.
Hubs and cover plates
Top of socket with hub opening has a flanged lip to keep
out moisture. This requires a hub or cover plate to close.
There are two sizes of openings: “small” for conduit hubs
with sizes of 1”, 1-1/4”, 1-1/2”, 2”, and 2-1/2”; and “large”
for conduit hubs with sizes 3”, 3-1/2”, and 4”. See Product
Schedule 499. Talon hub openings conform to ANSI
C12.7 specs and are interchangeable with other socket
manufacturers, but are not interchangeable with panel
board style hubs.
Bypass types
A self-contained meter completes the circuit between
the utility and the customer. In order to change the
meter, the circuit must be broken, turning off the power
to the customer. This is not acceptable in commercial
establishments, or in many other types of services. A
bypass allows a parallel path for the current flow,
unmetered, while the meter is pulled.
Types are:
a) Lever-operated jaw release, also known as jaw
clamping lever bypass (Talon type HQ). The
best, because the meter cannot accidentally be
pulled unless the bypass is engaged. Pulling the meter
would also be a major safety hazard if there is a 480V
installation and/or a large load in place, as the meter
would then act as a switch, and cause arc.
b) Lever-operated non-jaw release (Talon type MQ).
Lever bypasses the meter, but the meter may be
removed with the bypass open.
c) Horn bypass (option on residential sockets). Tangs on
line and load connectors allow for jumper leads to be
fitted over them before the meter is pulled.
d) Manual bypass (K-4, K-5, K-7) uses separate “links”,
which are clamped onto special studs before the meter
is removed. K-7 also uses a “rotating link” type bypass.
e) Other types not made by Talon include: slide
links, screw type, and automatic circuit closers.
|
Meter Mounting Equipment for use in Texas and Oklahoma
3
135A Continuous Meter Mounting Equipment
Residentialab, 4 & 5 terminal for 1 phase, 3 wire
Cont. amp
rating
Service
Connectors
Line
Load
Dimensions (in.)
W
H
D
Hub
opening
Bypass
Enclosure
material
Catalog
number
135
OH/UG
#14-2/0
8.0
11.7
3.6
1.25” Hub Inst
None
Steel
UAT111-BG
8.0
11.7
3.6
RX Cl. Plate
None
Aluminum
UAT131-XGF
8.0
11.7
3.6
RX Opening
None
Steel
UAT111-0Gd
11.7
3.6
RX Opening
Horn
Steel
UAT111-0PQGd
8.0
11.7
3.6
RX Cl. Plate
None
Steel
UAT121-XGSPc
#14-2/0
Residential - 135A - 4 & 5 Jaw - Ringless
Approved for Brownsville Public Utilities Board
135
OH/UG
#14-2/0
#14-2/0
Approved for Entergy and El Paso Electric Co.
135
OH/UG
#14-2/0
#14-2/0
Approved for AEP West and Southwestern Public Service
135
OH/UG
#14-2/0
#14-2/0
8.0
Approved for CenterPoint Power, AEP West and Entergy
135
OH/UG
#14-2/0
#14-2/0
Approved for CPS (San Antonio Public Service)
135
OH
#14-2/0
#14-2/0
8.0
11.7
3.6
1.25” Hub Inst
Horn
Steel
UAT111-BPCC
135
UG
#14-2/0
#14-2/0
8.0
11.7
3.6
Blank
Horn
Steel
UAT121-PPCC
a All units include a quad neutral.
b 5th terminal kit for field installation: H659-0121.
See accessories page in back.
c Device has a ring-style cover. CenterPoint Power will provide the ring.
d OH only for Entergy.
UAT1X1
Knockouts (inches):
4
g:
1/4
L:
1/2, 3/4,1,1-1/4,1-1/2
N:
3/4,1,1-1/4,1-1/2, 2
R:
1,1-1/4,1-1/2, 2
RX:
x2.750 HUB OP
|
Meter Mounting Equipment for use in Texas and Oklahoma
UAT111-0PQG
200A Meter Mounting Equipment
Residentialab, 4 & 5 terminal for 1 phase, 3 wire
Cont. amp
rating
Service
Connectors
Line & Load
Dimensions (in.)
W
H
D
a All units include a quad neutral.
b 5th terminal kit for field installation: H659-0121.
See accessories page in back.
UAT317-0G
UAT417-0G
Bypass
Enclosure
material
Catalog
number
Blank
RX Cl. Plate
None
None
Steel
Steel
UAS877-PG
UAS877-XG
RX Cl. Plate
None
Steel
UAT427-XMWRe
RX Opening
2” Hub Inst.
None
None
Steel
Steel
UAT317-0G
UAT317-DG
RX Opening
Blank
None
None
Steel
Steel
UAT314-0G
UAT417-PGe
RX Cl. Plate
None
Steel
UAT417-XGe
RX Opening
None
Steel
UAT417-0Ge
RX Opening
RX CL. Plate
None
None
Steel
Steel
UAT327-0GSP
UAT427-XGSPc
RX Opening
Blank
RX Opening
Blank
Horn
Horn
Horn
Horn
Steel
Steel
Aluminum
Aluminum
UAT317-0PQG
UAS877-PPZA
UAT337-0PQG
UAS837-PPG
2” Hub Inst.
Blank
Horn
Horn
Steel
Steel
UAT317-DPCC
UAT817-XPCC
Residential - 200A - 4 & 5 Jaw - Ringless
Approved for Entergy and Texas-New Mexico Power (UG only)
200
UG
#6-350 kcmil
13.0
14.0
5.1
200
OH/UG
#6-350 kcmil
13.0
14.0
5.1
Approved for El Paso Electric and Entergy
200
OH/UG
#6-350 kcmil
11.0
15.0
4.5
Approved for Entergy and ONCOR
200
OH
#6-350 kcmil
8.0
15.0
4.5
200
OH
#6-350 kcmil
8.0
15.0
4.5
Approved for Entergy
160
OH
#6-350 kcmil
8.0
15.0
4.5
200
OH/UG
#6-350 kcmil
11.0
15.0
4.5
Approved for Entergy, CoServ and El Paso Electric Co.
200
OH/UG
#6-350 kcmil
11.0
15.0
4.5
Approved for Entergy, ONCOR, and Southwestern Public Service
200
OH/UG
#6-350 kcmil
11.0
15.0
4.5
Approved for CenterPoint Power
200
OH
#6-350 kcmil
8.0
15.0
4.5
200
OH/UG
#6-350 kcmil
11.0
15.0
4.5
Approved for AEP West
200
OH
#6-350 kcmil
8.0
15.0
4.5
200
UG
#6-350 kcmil
13.0
14.0
5.1
200
OH
#6-350 kcmil
8.0
15.0
4.5
200
UG
#6-350 kcmil
13.0
14.0
5.1
Approved for CPS (San Antonio Public Service)
200
OH
#6-350 kcmil
8.0
15.0
4.5
200
OH/UG
#6-350 kcmil
13.0
15.0
5.1
Hub
opening
c Device has a ring style cover. CenterPoint Power will provide the ring.
d Includes stainless steel latch and hasp.
e OH only for Entergy.
UAS877-PG
UAT427-XGSP
UAS877-PPZA
UAT417-XG
w/ H659-0121 installed
Knockouts (inches):
UAT4X7
UAT3X7
|
UAT8X7
g:
1/4
A:
1/2
S:
1,1-1/4,1-1/2, 2, 2-1/2
AB:
1/4, 1/2, 7/8
AC:
1/4, 1/2
AD:
1-1/4, 1-1/2, 2, 2-1/2, 3
RX:
x2.750 HUB OP
Meter Mounting Equipment for use in Texas and Oklahoma
5
100/150A Position Meter Mounting Equipment
Residential - 100/150A - 4 Jaw - Horizontal gang
Residentialabc, Horizontal Gang, 4 terminal for 1 phase, 3 wire
No.
pos.
Cont. amp
rating
Connectors
Line
Connectors
Load
Dimensions (in.)
W
H
D
Hub openinig
2
100
#6-350 kcmil
#14-2/0
24.0
4.5
RX Opening
12.0
Catalog number
Aluminum encl.
Catalog number
Steel encl.
UA2311-0PQGd
3
100
#6-350 kcmil
#14-2/0
32.0
12.0
4.5
RX Opening
UA3311-0PQGd
4
100
#6-350 kcmil
#14-2/0
40.0
12.0
4.5
RX Opening
UA4311-0PQGd
Approved for Brownsville and ONCOR (Aluminum only for Brownsville)
2
100
#6-350 kcmil
#14-2/0
24.0
12.0
4.5
RX Opening
UA2331-0G
UA2311-0G
3
100
#6-350 kcmil
#14-2/0
32.0
12.0
4.5
RX Opening
UA3331-0G
UA3311-0G
4
100
#6-350 kcmil
#14-2/0
40.0
12.0
4.5
RX Opening
UA4331-0G
UA4311-0G
Approved for ONCOR
2
150
#6-350 kcmil
#6-350 kcmil
24.0
12.0
4.5
RX Opening
UA2313-0G
3
150
#6-350 kcmil
#6-350 kcmil
32.0
12.0
4.5
RX Opening
UA3313-0G
4
150
#6-350 kcmil
#6-350 kcmil
40.0
12.0
4.5
RX Opening
UA4313-0G
a Unit is supplied with a ground lugs.
b All sockets are suitable for either overhead or underground feed.
c 5th terminal kit for field installation: H659-0121.
See accessories page in back.
d Sockets with “QG” suffix are equipped with 2 ground lugs.
UA2311/2313
UA2311-0PQG with H659-0121 installed
UA3311/3313
UA4311/4313
Knockouts (inches):
S:
6
|
Meter Mounting Equipment for use in Texas and Oklahoma
1,1-1/4,1-1/2, 2, 2-1/2
AC:
1/4, 1/2
RX:
x2.750 HUB OP
200A/Position Meter Mounting Equipment
Residentialabc, Horizontal Gang, 4 & 5 terminal for 1 phase, 3 wire
Cont. amp
per pos.
Connectors
Line
Dimensions (in.)
W
H
D
Hub
opening
Bypass
Catalog
number
2
200
#1/0-600 kcmil
3
200
#1/0-600 kcmil
#6-350 kcmil
24.0
14.5
5.1
HD Opening
None
UA2717-YG
#6-350 kcmil
32.0
14.5
5.1
HD Opening
None
UA3717-YG
4
200
5
200
(2) #1/0-600 kcmil
#6-350 kcmil
43.0
14.5
5.1
HD Opening
None
UA4719-YG
(2) #1/0-600 kcmil
#6-350 kcmil
51.0
14.5
5.1
(2) HD Openings
None
UA5719-KG
6
200
(2) #1/0-600 kcmil
#6-350 kcmil
59.0
14.5
5.1
(2) HD Openings
None
UA6719-KG
Load
Approved for AEP West and ONCOR
2
200
#1/0-600 kcmil
#6-350 kcmil
24.0
14.5
5.1
HD Opening
Horn
UA2717-YPQGd
3
200
#1/0-600 kcmil
#6-350 kcmil
32.0
14.5
5.1
HD Opening
Horn
UA3717-YPQGd
4
200
(2) #1/0-600 kcmil
#6-350 kcmil
43.0
14.5
5.1
HD Opening
Horn
UA4719-YPQGd
5
200
(2) #1/0-600 kcmil
#6-350 kcmil
51.0
14.5
5.1
(2) HD Openings
Horn
UA5719-KPQGd
6
200
(2) #1/0-600 kcmil
#6-350 kcmil
59.0
14.5
5.1
(2) HD Openings
Horn
UA6719-KPQGd
Approved for Brownsville Public Utilities Board (All devices have aluminum enclosures)
2
200
#1/0-600 kcmil
#6-350 kcmil
24.0
14.5
5.1
HD Opening
None
UA2736-ZGF
3
200
#1/0-600 kcmil
#6-350 kcmil
32.0
14.5
5.1
HD Opening
None
UA3737-ZGF
4
200
(2) #1/0-600 kcmil
#6-350 kcmil
43.0
14.5
5.1
HD Opening
None
UA4739-ZGF
5
200
(2) #1/0-600 kcmil
#6-350 kcmil
51.0
14.5
5.1
(2) HD Openings
None
UA5739-MGF
6
200
(2) #1/0-600 kcmil
#6-350 kcmil
59.0
14.5
5.1
(2) HD Openings
None
UA6739-MGF
Residential - 200A/position - 4 & 5 Jaw - Horizontal Gang
No.
pos.
a All units are equipped with a ground lug.
b All sockets are suitable for either overhead or underground feed.
c 5th terminal kit for field installation: H659-0121.
See accessories page in back.
d Sockets with “QG” suffix have 2 ground lugs.
UA27X6
UA2716-YG
UA37X7
Knockouts (inches):
X:
UA47X9
UA57X9
|
1-1/4, 1-1/2, 2, 2-1/2
AC:
1/4, 1/2
AD:
1-1/4, 1-1/2, 2, 2-1/2, 3
HD:
x4.281 HUB 0P
UA67X9
Meter Mounting Equipment for use in Texas and Oklahoma
7
200A Meter Mounting Equipment
Commercial/Industrial - 200A - 5 Jaw - Type CQ
Commercial/Industrialabc, Type MQ, 5 & 7 terminal for 1 phase, 3 wire
and 3 phase, 4 wire
Cont. amp
rating
Service
Connectors
Line
Dimensions (in.)
W
H
D
Hub
opening
No. of
term.
Bypass
Catalog
number
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
5
Lever
40205-01d
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
7
Lever
N40607-025
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
5
Lever
40605-025d
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
7
None
30407-025e
Load
Approved for ONCOR
200
OH/UG
a Type MQ bypass mechanism is lever-operated, non-jaw clamping.
b Disconnect sleeves should not be used with these devices.
c 5 terminal devices are not for use with 3 phase, 3 wire service.
d Type MQ-5 devices have 5th terminal in the 9 o’clock position.
e Ring style cover, no bypass lever.
4060X
3040X
40605-025
4020X
Knockouts (inches):
8
|
g:
1/4
A:
1/2
B:
1/2, 3/4
S:
1,1-1/4,1-1/2, 2, 2-1/2
AI:
1, 1-1/4, 1-1/2, 2, 2-1/2, 3
AF:
1, 1-1/2, 2, 2-1/2, 3
AG:
3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX:
x2.750 HUB OP
Meter Mounting Equipment for use in Texas and Oklahoma
40205-01
200A Meter Mounting Equipment
Commercial/Industrialab, Type HQ, 4, 5 & 7 terminal for
1 phase, 3 wire, polyphase, 3 or 4 wire, Wye or Delta
Service
Connectors
Line
Load
Dimensions (in.)
W
H
D
Hub
opening
No. of
Term.
Bypass
Enclosure
material
Catalog
number
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
5
Lever
Steel
40005-01cd
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
4
Lever
Steel
40404-025g
13.0
19.0
5.2
RX Cl. Plate
5
Lever
Steel
40405-025cdg
Approved for Entergy
200
OH/UG
#6-350 kcmil
Approved for Entergy, AEP West, and CoServ
200
OH/UG
#6-350 kcmil
#6-350 kcmil
Approved for Xcel Energy, Entergy, AEP West and El Paso Electric Co.
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
7
Lever
Steel
40407-025g
Approved for AEP West
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
4
Lever
Steel
40804-01QGe
200
OH/UG
#6-350 kcmil
#6-350 kcmil
11.0
19.0
5.2
RX Cl. Plate
4
Lever
Steel
40404-02QGe
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
5
Lever
Steel
40405-02QGcde
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
5
Lever
Steel
40005-01QGcde
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
13.0
5.2
RX Cl. Plate
7
Lever
Steel
40407-02QGe
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
13.0
5.2
RX Opening
5
Lever
Aluminum
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
13.0
5.2
RX Opening
7
Lever
Aluminum
41405-015Fcd
#6-350 kcmil
16.0
20.0
5.2
RX Cl. Plate
7
Lever
Steel
9804-9142
Approved for CoServ and El Paso Electric Co.
200
OH/UG
#4-600 kcmil
Approved for Xcel Energy
41407-015F
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
5
Lever
Steel
40405-02COf
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
5
Lever
Steel
200
OH
#6-350 kcmil
#6-350 kcmil
10.0
17.5
5.2
RX Opening
7
Lever
Steel
40005-01Ff
Approved for ONCOR
40007-01F
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
5
Lever
Steel
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
7
Lever
Steel
10.0
17.5
5.2
2” Hub Inst.
7
Lever
Steel
40027-02
13.0
19.0
5.2
RX Cl. Plate
7
Lever
Steel
30407-025g
10.0
17.5
5.2
2” Hub Inst.
7
Lever
Steel
40027-02CC
41405-025F
Approved for Texas-New Mexico Power
200
OH
#6-350 kcmil
#6-350 kcmil
Approved for CenterPoint Power and Entergy
200
OH/UG
#6-350 kcmil
#6-350 kcmil
Approved for CPS (San Antonio Power)
200
OH
#6-350 kcmil
#6-350 kcmil
Approved for Brownsville Public Utilities Board
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
5
Lever
Aluminum
200
OH/UG
#6-350 kcmil
#6-350 kcmil
13.0
19.0
5.2
RX Cl. Plate
7
Lever
Aluminum
a Units are not suitable for use with disconnect sleeves.
b Bypass mechanism is lever-operated, jaw
pressure release with 100% bypass capacity.
Knockouts (inches):
g: 1/4
A: 1/2
B: 1/2, 3/4
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
EE: 2, 2-1/2, 3
RX: x2.750 HUB OP
Commercial/Industrial - 200A - 4, 5 & 7 Jaw - Type HQ
Cont.
amp
rating
9804-8592cd
40407-025F
41407-025F
c Devices have 5th terminal in the 6 o’clock position
and are OK for use with 3 phase 3 wire service.
d Neutral can be isolated by removing the ground strap.
e Sockets with “QG” suffix are supplied with 2 ground lugs.
f Devices have 5th Terminal in the 9 o’clock position and are not
for use with 3 phase, 3 wire service.
g OH only for Entergy.
9804-9142
9804/9142
|
404/414
410/400
Meter Mounting Equipment for use in Texas and Oklahoma
40407-025
9
320A Cont./400A Max. Meter Mounting Equipment
Commercial - 320A cont./400A max. - 4 & 5 Jaw - Type HQ
Commercialabc, Type HQ, 4 & 5 terminal for 1 phase, 3 wire
& polyphase, 4 wire
Cont.
amp
rating
Service
Connectors
Line
Dimensions (in.)
W
H
D
Load
Hub
opening
No.
of
term.
Bypass
Enclosure
material
Catalog
number
320
OH/UG
#4-600 kcmil
#4-600 kcmil
13.0
28.0
5.0
HD Cl. Plate
4
Lever
Steel
47604-82g
320
OH/UG
#4-600 kcmil
(2) #6-350 kcmil
13.0
28.0
5.0
HD Cl. Plate
5
Lever
Steel
47605-82g
320
OH/UG
#4-600 kcmil
#4-600 kcmil
14.0
28.0
6.0
HD Cl. Plate
4
Lever
Steel
47704-82g
320
OH/UG
#4-600 kcmil
#4-600 kcmil
14.0
28.0
6.0
3” Hub Inst.
4
Lever
Steel
47744-82g
320
OH/UG
#4-600 kcmil
(2) #6-350 kcmil
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48004-82g
Approved for AEP West, Entergy, CenterPoint Power and Texas-New Mexico Power
320
OH/UG
3/8-24 Stud
3/8-24 Stud
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48104-02
320
OH/UG
(2) 1/0-250kcmil
(2) #6-350 kcmil
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48104-82
3/8-24 Stud
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48104-82WId
3/8-24 Stud
13.0
28.0
5.0
HD Cl. Plate
4
Lever
Steel
47604-02QGh
Approved for CoServ
320
OH/UG
3/8-24 Stud
Approved for Entergy and Southwestern Public Service
320
OH/UG
3/8-24 Stud
Approved for AEP West
320
OH/UG
3/8-24 Stud
3/8-24 Stud
13.0
28.0
5.0
HD Cl. Plate
5
Lever
Aluminum
47605-A15Fe
320
OH/UG
#4-600 kcmil
(2) #6-300 kcmil
16.0
31.0
5.0
HD Cl. Plate
5
Lever
Steel
49505-82
14.0
28.0
6.0
HD Opening
5
Lever
Steel
47705-01FLe
1/2-20 Stud
14.0
28.0
6.0
HD Cl. Plate
4
Lever
47704-02f
3/8-24 Stud
20.0
34.0
6.0
HD Cl. Plate
5
Lever
48705-02FE
1/2-20 Stud
14.0
28.0
6.0
HD Opening
4
Lever
Steel
47704-01NU
3/8-24 Stud
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48104-02CH
Approved for Xcel Energy and El Paso Electric Company
320
OH/UG
1/2-20 Stud
1/2-20 Stud
Approved for Texas-New Mexico Power
320
OH
1/2-20 Stud
Approved for El Paso Electric
320
OH/UG
3/8-24 Stud
Approved for ONCOR
320
OH/UG
1/2”-20 Stud
Approved for Entergy
320
OH/UG
3/8-24 Stud
Approved for CPS (San Antonio Public Service)
320
OH
#4-600 kcmil
#4-600 kcmil
13.0
25.0
5.0
3” Hub Inst.
4
Lever
Steel
47644-82CC
320
OH/UG
(2) #4-350 kcmil
(2) #4-350 kcmil
16.0
31.0
5.0
HD Cl. Plate
4
Lever
Steel
48104-82CC
Approved for Brownsville Public Utilities Board
320
OH/UG
1/2”-20 Stud
1/2-20 Stud
16.0
28.0
6.0
HD Opening
4
Lever
Aluminum
41704-01
320
OH/UG
1/2”-20 Stud
1/2-20 Stud
20.0
34.0
6.0
HD Cl. Plate
5
Lever
Aluminum
49105-02FL
a All units have a lever operated, jaw pressure release bypass mechanism rated at 100%.
b Disconnect sleeves should not be used with these devices.
c Some devices do not include lugs, order separately.
d Includes anti-inversion clip H59676.
e 5 jaw devices are not for use with 3 phase, 4 wire service.
f Overhead use only for TNP.
g H60162 and H61300 lugs are also rated for (2) 250 kcmil.
h OH only for Entergy.
Knockouts (inches):
A:
B:
Z:
AC:
AE:
AG:
EE:
GG:
HH:
HD:
10
1/2
1/2, 3/4
1-1/2, 2, 2-1/2
1/4, 1/2
1/4, 1/2, 3/4, 1, 1-1/4
3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
2, 2-1/2, 3
2-1/2, 3, 3-1/2
2-1/2, 3, 3-1/2, 4
x4.281 HUB OP
|
48X04
49504
4870X
Meter Mounting Equipment for use in Texas and Oklahoma
4770X
476/485
320A Cont./400A Max. Meter Mounting Equipment
Commercialabc, Type HQ, 7 terminal for 1 phase, 3 wire
& polyphase, 4 wire
Cont.
amp
rating
Hub
opening
No.
of
term.
Bypass
Enclosure
material
Catalog
number
#4-600 kcmil
#4-600 kcmil
14.0
28.0
6.0
HD Cl. Plate
7
Lever
Steel
47707-82d
(2) #4-350 kcmil
(2) #4-350 kcmil
20.0
34.0
6.0
HD Cl. Plate
7
Lever
Steel
48707-82
Service
320
OH/UG
320
OH/UG
Approved for Xcel Energy and El Paso Electric Company
320
OH/UG
1/2-20 Stud
1/2-20 Stud
14.0
28.0
6.0
HD Opening
7
Lever
Steel
47707-01FLe
320
OH/UG
1/2-20 Stud
1/2-20 Stud
20.0
34.0
6.0
HD Cl. Plate
7
Lever
Steel
44707-02FL
Steel
48707-02
Approved for AEP West, CoServ, Entergy and Texas-New Mexico Power
320
OH/UG
3/8-24 Stud
3/8-24 Stud
20.0
34.0
6.0
HD Cl. Plate
7
Lever
20.0
14.0
6.0
HD Cl. Plate
7
Lever
44707-02
20.0
34.0
6.0
HD Cl. Plate
7
Lever
48707-02FE
20.0
34.0
6.0
HD Cl. Plate
7
Lever
Approved for Texas-New Mexico Power
320
OH/UG
1/2-20 Stud
1/2-20 Stud
Approved for El Paso Electric and CenterPoint Power
320
OH/UG
3/8-24 Stud
3/8-24 Stud
Approved for Brownsville Public Utilities Board
320
OH/UG
1/2-20 Stud
1/2-20 Stud
Aluminum
49107-02FL
a All units have a lever operated, jaw pressure release bypass mechanism rated at 100%.
b Disconnect sleeves should not be used with these devices.
c Some devices do not include lugs, order separately.
d H60162 and H61300 lugs are also rated for (2) 250 kcmil.
e OH only for Entergy.
Commercial - 320A cont./400A max. - 7 Jaw - Type HQ
Load
Dimensions (in.)
W
H
D
Connectors
Line
Knockouts (inches):
A:
1/2
B:
1/2, 3/4
Z:
1-1/2, 2, 2-1/2
AC:
1/4, 1/2
AE:
1/4, 1/2, 3/4, 1, 1-1/4
AG:
3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
EE:
2, 2-1/2, 3
GG:
2-1/2, 3, 3-1/2
HH:
2-1/2, 3, 3-1/2, 4
HD:
x4.281 HUB OP
44707-02
shown w/ line lugs
4870X
4470X
|
47707-01FL
4770X
Meter Mounting Equipment for use in Texas and Oklahoma
11
400/480A Meter Mounting Equipment
Residentiala, Type K4, 4 terminal for 1 phase, 3 wire
Cont./Max,
amp rating
Type
Service
Connectors
Line
Load
Dimensions (in.)
W
H
D
Hub
opening
Bypassb
Encl.
matl.
Catalog
numberd
(2) #6-350 kcmil
(2) #6-350 kcmil
18.0
36.0
6.1
HD Cl. Plate
H56495
Steel
9810-8502
1/2-20 Stud
1/2-20 Stud
18.0
36.0
6.1
HD Cl. Plate
H56495
Steel
9810-8523b
Approved for El Paso Electric Company
Residential - 400/480A - 4 Jaw - Type K4
400/400
K4UT
OH/UG
Approved for Entergy
480/600
K4UT
OH/UG
a Optional Manual Bypass H56495 available, normally for utility use only - 2 required.
b Contact Houston Light & Power for connectors.
Residential Type K-4
Overhead
Parallel conductor
2 - H58853
2 - H56425
1 - H56732
Overhead
Single conductor line
Parallel conductor load
2 - H58852
2 - H56425
1 - H56476
1 - H56732
Underground
Parallel conductor
2 - H58853
2 - H56732
1 - H56426
Underground
Single conductor line
Parallel conductor load
2 - H58852
2 - H56425
1 - H56476
1 - H56732
9810-8502
Overhead
Single conductor
4 - H58852
2 - H56476
K4UT
Knockouts (inches):
B:
12
1/2, 3/4
GG:
2-1/2, 3, 3-1/2
HH:
2-1/2, 3, 3-1/2, 4
HD:
x4, 281 HUB OP
|
Meter Mounting Equipment for use in Texas and Oklahoma
Underground
4 - H58852
2 - H56476
400/480A Meter Mounting Equipment
Residential/Commercial/Industriala, Type K-7, 7 terminal & 7 terminal
Side Wired, polyphase, 3 or 4 wire, Wye or Delta
Type
Service
Connectors
Line
Load
Dimensions (in.)
W
H
D
Hub
Opening
Bypassb
Encl.
matl.
Catalog
number
400/400
K7T
OH/UG
1/2-20 Stud
1/2-20 Stud
20.0
43.0
6.0
HD Cl. Plate
H58888
Steel
9817-8512
480/600
K7T
OH/UG
1/2-20 Stud
1/2-20 Stud
20.0
43.0
6.0
(2) HD Cl. Plates H58888
Steel
9817-9504
a All units are UL listed.
b Optional Manual Bypass H58888 available, normally for utility use only (3 required).
Residential Type K-7
Overhead
Single conductor
8 - H56476
Overhead
Parallel conductor
8 - H56732
Overhead
Single and triple load feed
4 - H56476
4- H68752-1
Residential/Commercial/Industrial - 400/480A - 7 Jaw - Type K-7
Cont./Max.
amp rating
9810-8502
K7T-400 Amp
Underground
Single conductor
3 - H58852
5 - H56476
Underground
Single conductor line
Triple conductor load
3 - H58852
1 - H56476
4 - H68752-1
Underground
Parallel conductor
3 - H58853
5 - H56732
Knockouts (inches):
B:
|
K7T-600 Amp
1/2, 3/4
HH:
2-1/2, 3, 3-1/2, 4
HD:
x4, 281 HUB OP
Meter Mounting Equipment for use in Texas and Oklahoma
13
100/200A Meter Mounting Equipment
Residential - 100/200A - 4 & 5 Jaw - Meter Mains
Residentiala, Meter Main
4 and 5 terminal for 1 phase, 3 wire
Connectors
Line
Load
Dimensions (in.)
W
H
D
Hub
opening
Main
breaker
No.
term.
Bypass
Cover
style
Catalog
number
OH/UG
#6-250
kcmil
#2-1/0 CU,
2/0 AL
18.5
17.0
5.1
RX Cl.
Plate
125A
Inst.
5
Horn
Ringless
LGMM0202B1125RJBX
be
150
OH/UG
#6-250
kcmil
#1-300
kcmil
18.5
17.0
5.1
RX Cl.
Plate
150A
Inst.
5
Horn
Ringless
LGMM0202B1150RJBX
be
200
OH/UG
#6-250
kcmil
#1-300
kcmil
18.5
17.0
5.1
RX Cl.
Plate
200A
Inst.
5
Horn
Ringless
LGMM0202B1200RJBX
be
150
OH/UG
#6-250
kcmil
#1-300
kcmil
16.0
17.0
5.1
RX Cl.
Plate
150A
Inst.
4
None
Ring
LGMM0202B1150
200
OH/UG
#6-250
kcmil
#1-300
kcmil
16.0
17.0
5.1
RX Cl.
Plate
200A
Inst.
4
None
Ring
LGMM0202B1200
see breaker
rating
11.6
28.0
5.2
RX Cl.
Plate
150-200A
Prov.
4
None
Ringless
UAB417-XPG
see breaker
rating
13.1
25.1
5.2
Blank
Top
150-200A
Prov.
4
None
Ringless
UAB877-PG
#4-250
kcmil
14.0
30.0
5.0
RX Cl.
Plate
MBK200
4
None
Ringless
LG0816B1200RCT
27.0
29.0
6.0
HD-top
HD-bot
QN2200H
4
Lever
Ringless
LG0816B1400RLT
40.1
6.5
HD Cl.
Plate
(2) Prov.
fpr QN or
QP type
5
Lever
Ringless
LG0404L1400RLM
Rating
Service
125
Approved for Texas-New Mexico Power
200
OH/UG
#6-350
kcmil
Approved for Entergy
200
UG-SW
#6-350
kcmil
Approved for El Paso Electric
200
OH/UG
#4-250
kcmil
Approved for AEP and Xcel Energy
320
OH/UG
#1-600
kcmil or
(2) 1/0250
#1-300
kcmil
Approved for El Paso Electric and Xcel Energy
320
OH/UG
#4-600
kcmil or
(2) 1/0360
see breaker
rating
30.1
a All units are UL listed.
b 5th terminal factory installed.
c 5th terminal for field installation: H659-0121.
d UAB111-0PCH has a provision for a 125 amp max. circuit breaker.
See breaker table for details.
e Breaker factory installed. See breaker table for replacement circuit breakers.
See accessories page in back.
UAB4
Knockouts (inches):
Breaker table
Amps
Circuit breaker
100
Q2100
125
Q2125
150
QN2150
200
QN2200
s:
UAB317
200
14
QJ22B200
|
UAB417-XG
LGMM0202B1200
Meter Mounting Equipment for use in Texas and Oklahoma
g:
A:
C:
S:
Z:
DD:
RX:
5/16 on UAB4
5/16,1/2 on UAB8
1/4
1/2
1/2, 3/4, 1
1,1-1/4,1-1/2, 2, 2-1/2
1-1/2, 2, 2-1/2
1-1/4,1-1/2, 2, 2-1/2, 3
x2.750 HUB OP
Type PTS Transformer-Rated Meter Mounting
Equipment with Test Switch Provision
Product Schedule 465
PTS6:
6 Jaw
PTS8:
8 Jaw
Ringless - Split Cover
Steel
Aluminum
Ring Type - Split Cover
Steel
Aluminum
Dimensions
L
W
D
Cont.
Amp. Hub
Rating Opening
Terminal Wire Range
Current Potential
9837-8200
9837-8201
9837-8202 9837-8203 9837-8204 9837-8205 20.0 12.0 4.5 20
RX Cl. Plate
#4-14
#8-14
9837-8210
9837-8211
9837-8212 9837-8213 9837-8214 9837-8215 20.0 12.0 4.5 20
1” Hub Inst.
#4-14
#8-14
9837-8220
9837-8221
9837-8222 9837-8223 9837-8224 9837-8225 20.0 12.0 4.5 20
1.25” Hub Inst. #4-14
#8-14
9837-8230
9837-8231
9837-8232 9837-8233 9837-8234 9837-8235 20.0 12.0 4.5 20
1.50” Hub Inst. #4-14
#8-14
9837-8240
9837-8241
9837-8242 9837-8243 9837-8244 9837-8245 20.0 12.0 4.5 20
RX Opening
#4-14
#8-14
9837-8400
9837-8401
9837-8402 9837-8403 9837-8404 9837-8405 20.0 12.0 4.5 20
RX Cl. Plate
#4-14
#8-14
9837-8410
9837-8411
9837-8412 9837-8413 9837-8414 9837-8415 20.0 12.0 4.5 20
1” Hub Inst.
#4-14
#8-14
9837-8420
9837-8421
9837-8422 9837-8423 9837-8424 9837-8425 20.0 12.0 4.5 20
1.25” Hub Inst. #4-14
#8-14
9837-8430
9837-8431
9837-8432 9837-8433 9837-8434 9837-8435 20.0 12.0 4.5 20
1.50” Hub Inst. #4-14
#8-14
9837-8440
9837-8441
9837-8442 9837-8443 9837-8444 9837-8445 20.0 12.0 4.5 20
RX Opening
#4-14
#8-14
9837-8500
9837-8501
9837-8502 9837-8503 9837-8504 9837-8505 20.0 12.0 4.5 20
RX Cl. Plate
#4-14
#8-14
9837-8510
PTS13:
13
9837-8520
Jaw
9837-8530
9837-8511
9837-8512 9837-8513 9837-8514 9837-8515 20.0 12.0 4.5 20
1” Hub Inst.
#4-14
#8-14
9837-8521
9837-8522 9837-8523 9837-8524 9837-8525 20.0 12.0 4.5 20
1.25” Hub Inst. #4-14
#8-14
9837-8531
9837-8532 9837-8533 9837-8534 9837-8535 20.0 12.0 4.5 20
1.50” Hub Inst. #4-14
#8-14
9837-8540
9837-8541
9837-8542 9837-8543 9837-8544 9837-8545 20.0 12.0 4.5 20
RX Opening
#8-14
#4-14
General Information
Capacity:
20 amperes, 600 volts a.c.
Application:
Transformer-rated applications. Available with or without test switch and pre-wiring.
Enclosures:
14-gauge .063 aluminum or 16-gauge galvannealed steel suitable for indoor or outdoor installation.
Terminals:
Set screw type.
Hubs:
Interchangeable 1”, 1-1/4”, 1-1/2”
Finish:
Aluminum unpainted unless specified. Steel enclosures have gray polyester powder coat finish.
Test Switches:
Standard 6 and 10 pole, 480-volt rated switches are available from stock. Special switches available upon request.
Type PTS Transformer-Rated Meter Mounting Equipment
with Test Switch Provision
Catalog Numbers
Socket Ringless - Solid Cover
Type Steel
Aluminum
Common Features
n 20A continuous rated
n Ground lug available
n Steel or aluminum construction
n Split or solid cover construction
n OH and UG capabilities
n 600V rated
n Spacing for multiple test switch configurations
n Customized test switch and wiring
Consult the factory for other available options such
as, but not limited to alternate enclosure and hasp
material, kearnaloxed terminals, enclosures with
special KO configurations, pre-wired units, test
switch specifications and special labeling.
Note - The following devices are approved for
Brownsville Public Utilities Board:
9837-0916 (20A, 6T, prewired)
9837-0917 (20A, 8T, prewired)
9837-0918 (20A, 13T, prewired)
|
Knockouts (inches):
B:
1/2, 3/4
Q:
1, 1-1/4, 1-1/2
AC:
1/4, 1/2
RX:
x2.750 HUB OP
Meter Mounting Equipment for use in Texas and Oklahoma
15
Type HQ-T Transformer-Rated
Meter Mounting Equipment
Type HQ-T Transformer-Rated Meter Mounting Equipment
Product Schedule 467
Catalog Numbers
Removable Handle Removable Handle
Dimensions (in.)
W
H
D
Continuous
Amp. Rating
Hub
Opening
Terminal Wire Range
Current Term. Potential Term.
9804-8544
9804-8548
17.5
10.0
5.0
80
RX Cl. Plate
#4-14
#8-14
9804-8482
9804-8485
17.5
10.0
5.0
80
1” Hub Inst.
#4-14
#8-14
9804-8483
9804-8486
17.5
10.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
9804-8542
9804-8546
17.5
10.0
5.0
80
RX Cl. Plate
#4-14
#8-14
9804-8419
9804-8456a
17.5
10.0
5.0
80
1” Hub Inst.
#4-14
#8-14
9804-8422
9804-8459
17.5
10.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
9804-8543
9804-8547
17.5
10.0
5.0
80
RX Cl. Plate
#4-14
#8-14
HQ-13T: 9804-8420
13 Jaw
9804-8423
9804-8457
17.5
10.0
5.0
80
1” Hub Inst.
#4-14
#8-14
9804-8460
17.5
10.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
9804-8426
9804-8463
17.5
10.0
5.0
80
1.50” Hub Inst.
#4-14
#8-14
Socket
Type
HQ-6T:
6 Jaw
HQ-8T:
8 Jaw
a Approved for Fayetteville PWC.
General Information
Capacity:
80 ampere continuous, 600 volts a.c.
Application:
6 terminal, single phase 2 or 3 wire; 8 terminal, 2 or 3 phase, 3 wire, HQ-13T - 3 phase, 4 wire wye or 4 wire delta. For use
with transformer-rated Class 10 or 20 meters. May also be used on self-contained applications up to 80 ampere load.
Enclosures:
Constructed of 16 gauge galvannealed steel with polyester powder coat finish.
Also available in 12 gauge aluminum upon request.
Block Assembly:
Glass fiber reinforced polyester. High strength, arc and track resistant.
Bypass:
Lever-Operated Jaw Release - Moving lever up closes bypass, providing positive short circuiting of the current circuits and
releases jaw pressure on the meter current terminals providing easy removal of the meter. Also available is a removable
bypass handle which allows a solid cover, #37943-2 for HQ-T or #54199-2 for HQ-TS, to be placed on the box with the
bypass closed when it is necessary to remove the meter for in-shop repair or testing. Bypass capacity: 80 amp continuous.
Terminals:
Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14.
Potential terminals will accommodate from #8 to #14.
Hubs:
Cover plate or single removable gasketless hubs are interchangeable.
UL:
All sockets shown are UL approved.
Safety Shield:
Track resistant polycarbonate transparent safety shield provides liberal insulation between potential jaws and terminals
and protection from accidental shorts and shocks.
Common Features
n Clamping jaw lever bypass
n 80A continuous rated
n Ground lug available
n Screw type terminals with pressure plate
n Steel or aluminum construction
n Glass filled polyester block construction
n 200% rated bypass
n Overhead and underground capabilities
n 600V rated
Consult the factory for other available options such
as, but not limited to alternate enclosure and hasp
material, kearnaloxed terminals, enclosures with
special KO configurations and special labeling.
16
|
Meter Mounting Equipment for use in Texas and Oklahoma
Knockouts (inches):
g:
1/4
B:
1/2, 3/4
S:
1, 1-1/4, 1-1/2, 2, 2-1/2
AI:
1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX:
x2.750 HUB OP
Connections
Product Schedule 467
Form 6S
Form 8S
HQ-8T
Form 9S
Form 10S
Type HQ-T Transformer-Rated Meter Mounting Equipment
HQ-13T
HQ-6T
Form 5S
Form 4S
|
Form 3S
(2 Wire CT)
Meter Mounting Equipment for use in Texas and Oklahoma
Form 3S
(3 Wire CT)
17
Type HQ-TS Transformer-Rated Meter Mounting
Equipment with Test Switch Provision
Type HQ-TS Transformer-Rated Meter Mounting Equipment
with Test Switch Provision
Product Schedule 469
Socket
Type
Catalog Numbers
Removable Handle
9804-8557
9804-8561
19.0
13.0
5.0
80
RX Cl. Plate
#4-14
#8-14
HQ-6T:
6 Jaw
9804-8494
9804-8497
19.0
13.0
5.0
80
1” Hub Inst.
#4-14
#8-14
HQ-8T:
8 Jaw
HQ-13T:
13 Jaw
Solid Handle
Dimensions
L
W
D
9804-8495
9804-8498
19.0
13.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
9804-8496
9804-8499
19.0
13.0
5.0
80
RX Opening
#4-14
#8-14
9804-8559
9804-8563
19.0
13.0
5.0
80
RX Cl. Plate
#4-14
#8-14
9804-8518
9804-8521
19.0
13.0
5.0
80
1” Hub Inst.
#4-14
#8-14
9804-8519
9804-8522
19.0
13.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
9804-8669
9804-8523
19.0
13.0
5.0
80
RX Opening
#4-14
#8-14
9804-8560
9804-8564
19.0
13.0
5.0
80
RX Cl. Plate
#4-14
#8-14
9804-8530
9804-8533
19.0
13.0
5.0
80
1” Hub Inst.
#4-14
#8-14
-
9804-8532
19.0
13.0
5.0
80
RX Opening
#4-14
#8-14
9804-8531
9804-8534
19.0
13.0
5.0
80
1.25” Hub Inst.
#4-14
#8-14
General Information
Capacity:
80 ampere continuous, 600 volts a.c.
Application:
HQ-6TS - Single phase, 2 or 3 wire, HQ-8TS - 2 or 3 phase, 3 wire
HQ-13TS - 3 phase, 4 wire wye or 4 wire delta
For use with transformer-rated Class 10 or Class 20 meters and appropriate meter test switch.
Enclosures:
Ringless. Constructed of 16 gauge galvannealed steel with baked enamel finish for indoor or outdoor installation. Also
available in 12 gauge aluminum upon request. Box is adequately dimensioned and has mounting holes provided for test
switch installation.
Block Assembly:
Glass fiber reinforced polyester. High strength, arc and track resistant.
Bypass:
Jaw release type. Moving lever up closes bypass providing positive short circuiting of the current circuits and releases jaw
pressure on the meter current terminals providing easy removal of the meter. Also available is a removable bypass handle
which allows a solid cover (#54199-2) to be placed on the box with the bypass closed when it is necessary to remove the
meter for in-shop repair or testing. Bypass capacity: 80 amp continuous.
Terminals:
Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14 copper or aluminum.
Potential terminals will accommodate conductors from #8 to #14 copper or aluminum.
Hubs:
Available with cover plate or single removable gasketless hub. Hubs and cover plate are interchangeable.
UL:
All sockets shown are UL approved.
Common Features
n Clamping jaw lever bypass
n 80A continuous rated
n Ground lug available
n Screw type terminals with pressure plate
n Steel or aluminum construction
n Glass filled polyester block construction
n 200% rated bypass
n Overhead and underground capabilities
n 600V rated
n Spacing for multiple test switch configurations
Consult the factory for other available options such
as, but not limited to alternate enclosure and hasp
material, kearnaloxed terminals, enclosures with
special KO configurations and special labeling.
18
Terminal Wire Range
Current
Potential
Continuous
Hub
Ampere Rating Opening
|
Meter Mounting Equipment for use in Texas and Oklahoma
Knockouts (inches):
g:
1/4
A:
1/2
AF:
1, 1-1/2, 2, 2-1/2, 3
AG:
3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX:
x2.750 HUB OP
Connections
Product Schedule 469
General Information (continued)
Track resistant polycarbonate transparent insulating safety shield provides protection from accidental shorts and shocks.
Potential terminals are mounted in the safety shield for ease of wiring and testing.
Test Switch
Mounting:
An insulated mounting bracket is included below the meter socket for the customer installation of a standard test switch.
Holes are provided for No. 10-32 mounting screws.
Knockouts:
All box enclosures have one 1”, 1 1/4”, 1 1/2” concentric knockout in the back, and three 1”, 1 1/4”, 1 1/2” concentric
knockouts in the bottom. There are no knockouts in the sides. In addition, there are one 1/4” knockout and one 1/2”, 3/4”
concentric knockout in the bottom.
HQ-13TS
Form 6S
Form 8S
HQ-7TS
Form 9S
Form 10S
Type HQ-TS Transformer-Rated Meter Mounting Equipment
with Test Switch Provision
Safety Shield:
HQ-8TS
Form 7S
Form 24S
Form 5S
HQ-6TS
Form 4S
Form 3S
(2 Wire CT)
|
Form 3S
(3 Wire CT)
Meter Mounting Equipment for use in Texas and Oklahoma
19
Air Conditioning Disconnects
Fused and Non-fused
Air Conditioning Disconnects - Fused & Non-Fused
Features:
Flexibility
L 30-60 amperes
L 240 volts A.C.
L Padlock provisions
L Horsepower rated
L 10,000 A.I.C.
L New models available with internal GFCI receptacle
L Removable door
L Ample wiring space
Rugged Durability
L Noryl® thermoplastic and powder coated G90 steel
enclosures are corrosion resistant and extremely durable
giving long maintenance free service
L Copper conductors
L Raised mounting embosses
Steel AC Disconnects
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H
W
D
30
Fused pullout
LF2030
3
7.3
5.0
2.1
60
Fused pullout
LF2060
10
8.0
5.0
2.1
60
Non-fused pullout
LN2060
10
7.3
5.0
2.1
60
Non-automatic switch
LNAS2060
10
7.3
5.0
2.1
Plastic AC Disconnects
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H
W
D
30
Fused pullout
LF2030PL
3
8.0
5.3
3.1
60
Fused pullout
LF2060PL
10
8.0
5.3
3.1
60
Non-fused pullout
LN2060PL
10
7.3
5.0
2.1
60
Non-fused pullout
LN2060PLX
10
8.0
6.0
5.8
Steel AC Disconnects with 15 Amp GFCI Receptacle
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H
W
D
30
Fused pullout
LF2030GFCI
3
9.0
6.1
5.1
60
Fused pullout
LF2060GFCI
10
9.0
6.1
5.1
60
Non-fused pullout
LN2060GFCI
10
7.1
5.8
5.1
60
Non-automatic switch
LNAS2060GFCI
10
7.1
5.8
5.1
Wire Range Table
Copper
20
Aluminum
Connector
Solid
Stranded
Solid
Stranded
Line
#14-8
#14-3
#12-8
#12-3
Load
#14-8
#14-3
#12-8
#12-3
Neutral
#12-8
#12-2
#12-8
#12-2
Equip. grnd.
#12-8
#12-2
#12-8
#12-2
|
Meter Mounting Equipment for use in Texas and Oklahoma
Spa Panels
For use as spa/hot tub service disconnect
Features:
L UL
Listed
installed, 2-pole 50A or 60A GFCI breaker for 240V ground fault protection
L NEMA Type 3R outdoor enclosure
L 2 extra spaces (4 circuits manimum) for additional circuit breakers
L 125 Amp rated interior
L Factory installed 5 position ground bar
L Closure plate included
L Compact enclosure size
L Convenient standard package of 1
L Uses reliable Siemens circuit breakers
L Factory
Dimensions (inches)
H
W
D
Catalog
number
50A
12.3
6.0
4.5
LGSPA50
60A
12.3
6.0
4.5
LGSPA60
Spa Panels - 50A and 60A
2-Pole
GFCI breaker
12-1/4-”
dead front
hub cover plate
included
enclosure
|
6”
Meter Mounting Equipment for use in Texas and Oklahoma
21
Connector Lugs
H55890
3/8”
Stud
H55890-1
3/8”
Stud
H56734
1/2”
Stud
H37892
1/2”
Stud
H57606-K
3/8”
Stud
H56476
1/2”
Stud
H60162
1/2”
Stud
H61300
1/2”
Stud
H58022
3/8”
Stud
H56732
1/2”
Stud
H56732-1
1/2”
Stud
H56732-2
(2) #4-350 kcmil
3/8”
Stud
H56732-M
1/2”
Stud
H68752-1
1/2”
Stud
H56426
1/2”
Stud
H56477
#3/0-800 kcmil
1/2”
Stud
H56425
1/2”
Stud
H56425-M
1/2”
Stud
H58852
1/2”
Stud
H56733
1/2”
Stud
H56427
1/2”
Stud
H56427-M
1/2”
Stud
H58853
1/2”
Stud
H59299-1
1/2”
Stud
Connector Lugs
#6-350 kcmil
#6-350 kcmil
(2) #6-250 kcmil
(2) #4-500 kcmil
(2) #6-350 kcmil
(2) #6-350 kcmil
22
|
#6-350 kcmil
#3/0-800 kcmil
(2) #4-350 kcmil
(3) #6-250 kcmil
(2) #4-500 kcmil
(2) #4-500 kcmil
#6-250 kcmil
(1) #4-600 kcmil [or]
(2) #1/0-250 kcmil
(2) #4-350 kcmil
(4) #6-350 kcmil
#3/0-800 kcmil
(2) #6-350 kcmil
Meter Mounting Equipment for use in Texas and Oklahoma
#4-500 kcmil
(1) #4-600 kcmil [or]
(2) #1/0-250 kcmil
#3/0-800 kcmil
Connector Lugs
Pressure type lugs for Talon’s stud type meter mounting devices are made of 6061-T6 aluminum to provide high
strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion.
Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action
with the lug. All Talon lugs are listed with Underwriters Laboratories.
Pressure lug connectors for meter mounting devices
Device
type
Antirotation
feature
No
#6-350 kcmil
13/32”
9/16” Hex
2-1/4
1-1/8
1-1/4
H55890
HQ-4S
No
#6-350 kcmil
13/32”
5/16” Allen
2-1/4
1-1/8
1-1/4
H55890-1
Conductor
size
Stud
opening
Pressure
screw head
Dimensions* (inches)
L
W
H
Catalog
number
No
#6-350 kcmil
13/32”
3/8” Allen
2-1/4
1-1/8
1-1/4
H57606-K
No
(2) #6-250 kcmil
13/32”
5/16” Allen
2-3/16
1-5/8
1-3/16
H58022
HQ-4D
No
#4-500 kcmil
9/16”
3/8” Allen
2-13/16
1-1/2
1-9/16
H37892
HQ-5DM
Yes
(1) #4-600 kcmil
9/16”
1/2” Allen
2-13/16
1-3/8
1-13/16
H60162
No
(2) #1/0-250 kcmil
9/16”
1/2” Allen
2-13/16
1-3/8
1-13/16
H61300
HQ-7D
HQ-7DF
Connector Lugs
HQ-5 S
HQ-7S
or
K-4,5,7
No
(2) #6-350 kcmil
9/16”
5/16” Allen
2-7/8
1-57/64
1-1/4
H56425
K-4,5,7
No
(2) #4-500 kcmil
9/16”
3/8” Allen
2-13/16
2-1/16
1-9/16
H56425-M
K-4
No
(4) #6-350 kcmil
9/16”
5/16” Allen
2-7/8
3-15/16
1-1/4
H56426
K-4,5,7
Yes
(2) #6-350 kcmil
9/16”
5/16” Allen
4-15/16
1-1/8
2-1/16
H56427
K-4,5,7
Yes
(2) #2-500 kcmil
9/16”
3/8” Allen
4-1/4
1-1/8
1-13/16
H56427-M
K-5,7
Yes
#3/0-800 kcmil
9/16”
1/2” Allen
3-1/4
1-5/16
1-13/16
H56476
K-4,5,7
Yes
#3/0-800 kcmil
9/16”
1/2” Allen
3-1/4
1-5/16
1-13/16
H56477
K-5,7
No
(2) #4-500 kcmil
9/16”
3/8” Allen
2-13/16
2-5/32
1-9/16
H56490
K-5,7
Yes
(2) #4-350 kcmil
9/16”
5/16” Allen
2-7/8
1-59/64
1-1/4
H56732
K-5,7
No
(2) #4-350 kcmil
9/16”
5/16” Allen
2-7/8
1-59/64
1-1/4
H56732-1
K-5,7
Yes
(2) #4-500 kcmil
9/16”
3/8” Allen
2-13/16
2-5/32
1-13/16
H56732-M
K-4,5,7
Yes
#3/0-800 kcmil
9/16”
1/2” Allen
4-3/16
1-3/4
2-3/8
H56733
K-4,5,7
(Grd.)
No
#6-250 kcmil
9/16”
5/16” Allen
2-9/16
1-9/32
1-3/16
H56734
K-4,5,7
Yes
#3/0-800 kcmil
9/16”
1/2” Allen
3-15/16
1-3/4
1-13/16
H58852
K-4,5,7
Yes
(2) #6-350 kcmil
9/16”
5/16” Allen
3-15/16
1-1/8
1-1/2
H58853
K-4,5,7
Yes
(3) #6-250 kcmil
9/16”
5/16” Allen
2-7/8
2-31/64
1-7/16
H68752-1
K-4 extender
Yes
1/2-20 x 1-7/8” Stud
9/16”
None
4-1/4
1-1/4
2-3/8
H59299-1
Lug Extender
Device type
Stud opening
Stud size
Dimensions (inches)
W
H
D
Catalog
number
K-4
9/16”
1/2-20 x 1-7/8”
4-1/4
2-3/8
H59299-1**
1-1/4
* Dimensions do not include height of pressure screw with conductor installed.
** Includes nut and washer assembly and washer.
H
W
|
L
Meter Mounting Equipment for use in Texas and Oklahoma
23
Accessories
Sealing rings
Removable hub kits
Conduit Size
(inches)
Catalog
number
Description
Accessories
RX type hubs small
Removable hub
1
H38596-2
1-1/4
H38597-2
1-1/2
H38598-2
2
H38599-2
2-1/2
H38600-2
Cover plate - steel
H38595-1
Cover plate - aluminum
H38595-2
Stainless Steel
Snap Type
Stainless Steel
Screw Type
H54602
H9738-8002
HD Type Hubs Large
Cover plate
3
H56856-2
3-1/2
H56857-2
4
H56858-2
Cover plate - steel
H56933
Cover plate - aluminum
H56933-1
Accessories
Accessories
|
Description
Catalog
number
HQ isolated neutral kit
H64685-1*
*Includes neutral and isolation block
Description
24
Catalog
number
Catalog
number
Insulated 5th terminal kit
- Type AS, AT only
H659-0120
Grounded 5th terminal kit
- Type AS, AT only
H659-0121
Neutral isolation kit for HQ
H64690-1*
*Isolates existing neutral
HQ 5th terminal kit - 9:00
w/o wire
H35815-2
HQ 5th terminal kit - 9:00
w/ wire
H35815-3
HQ 5th teminal kit - 9:00
w/ 9” lead
*For use with side wired devices only.
H35815-5*
Large to small adaptor steel HD to RX
H9747-1113
Large to small adaptor aluminum HD to RX
H9747-1112
Black plastic meter
opening cover
H39968
Clear plastic meter
opening cover
(with plug-in feet)
H659-0162
Meter Mounting Equipment for use in Texas and Oklahoma
Insulated Jumper
H36479
Add-on grounding lug
for HQ/HQU
H55303
K-7 Rotary Bypass 600 Amp rated
H69623
K-7 Rake Type Bypass 600 Amp rated,
temp use only
H58888
K-4 Rake Type Bypass 600 Amp rated,
temp use only
H56495
Terms of Sale,
Meter Mounting Device Applications
Terms of sale
Transportation Charges: Prices listed are F.O.B. factory with freight prepaid and allowed on all shipments of orders of $1,000
net or more for single shipments to one location.
Cancellation: Orders accepted by the factory can be cancelled only with the factory’s consent and upon payment to the seller
of reasonable charges incurred by the seller which will indemnify the seller against loss.
Returns: Goods may not be returned to Talon without written authorization from the factory. A minimum 20% restocking
charge will be applicable on all returned goods. Credit will be given only for current production items in unopened cartons. All
transportation charges paid by Talon will be deducted from such credit.
Terms: Standard/Stock Products:
2% 10th net 25th for invoices dated the 1st through the 15th of the month.
2% 25th net 10th for invoices dated the 16th through the 31st of the month.
Meter Mounting Device Applications
Electrical
service
1-phase
3-phase, 3 wire or
network
Socket
type
Standard socket
Catalog number
4 jaw 100A
AT-1
4 jaw 200A
AT-3, AT-4, MQ-4, HQ-4
2SE
4 jaw 320A
HQ-4S, HQ-4D
Self-contained, bolt-in
2K
K4-400/480A
K-4, K-4UT
Transformer-rated, 2 wire
3S!
5 jaw 20A
HQ-6T, HQ-6TS, PTS-6
Transformer-rated, 3 wire
4S!
6 jaw 20A
HQ-6T, HQ-6TS
12S
5 jaw 100A
MQ-5, HQ-5
12S
5 jaw 200A
MQ-5, HQ-5
12SE
5 jaw 320A
HQ-5SWT, HQ-5D
Self contained bolt-in
12K
K-5 480/600A
K-5
Transformer-rated
5S
8 jaw 20A
HQ-8T, HQ-8TS, PTS-8
7 jaw 100/200/320A
MQ-7, HW-7
K-7 480/600A
K-7, K-7T
13 jaw 20A
HQ-13T, HQ-13TS, PTS-13
Service
type
Meter
form
Self-contained, 3 wire
Self-contained
3-phase, 4 wire
2S
Terms of sale - meter mounting device applications
Minimum Billing: $100 net plus transportation charges.
14S
Self-contained
15S
16S
14K
Wye
Self-contained, bolt-in
15K
16K
6S
Transformer-rated
8S
9S
or Delta
|
Meter Mounting Equipment for use in Texas and Oklahoma
25
Notes:
26
|
Meter Mounting Equipment for use in Texas and Oklahoma
Notes:
|
Meter Mounting Equipment for use in Texas and Oklahoma
27
Notes:
28
|
Meter Mounting Equipment for use in Texas and Oklahoma
Represented by:
JD Martin Inc.
1801 Royal Lane, Suite 100
Dallas, TX 75229
Phone: (972) 277-5600
Talon Meter Mounting Devices
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
www.talonmetering.com
Subject to change without prior notice
Order No.: RPSA-LG016-1211
All rights reserved
Printed in USA
© 2011 Siemens Industry, Inc.
The information provided in this brochure contains merely
general descriptions or characteristics of performance
which in case of actual use do not always apply as described
or which may change as a result of further development
of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.