Definite Purpose Control
Contents
Pages
Definite Purpose Contactors
Class
Class
Class
Class
42, 45 Product Nomenclature . . . . . . . . . . . . . . . .9/2
42, 45 General Application . . . . . . . . . . . . . . . . . .9/3
42, 45 Part Numbers . . . . . . . . . . . . . . . . . . . . . . .9/4
42 Modifications & Accessories . . . . . . . . . . . . . .9/5
Definite Purpose Starters
Class
Class
Class
Class
16
16
16
16
Product Nomenclature . . . . . . . . . . . . . . . . . . .9/6
General Application . . . . . . . . . . . . . . . . . . . . .9/7
Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . .9/8
Modifications & Accessories . . . . . . . . . . . . . .9/9
Replacement Parts for DP Controls
Class 16, 42 Replacement parts . . . . . . . . . . . . . .9/10-9/11
Class 16 Overload Heater Tables . . . . . . . . . . . . .9/12-9/14
DP Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . .9/15
Siemens Industry, Inc.
Industrial Controls Catalog
9/1
Definite Purpose Control
Definite Purpose Contactors
Class 42 & 45 product nomenclature
Class 45
D.P. CONTACTOR
45
CLASS
Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information
is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager.
C
AMP RATING
45 Contactor
(D.P.)
C
D
E
F
G
G
MODEL
20
25
30
35
40
G
2
POWER POLES
1
2
1 power pole
2 power poles
0
NC POWER POLES
0 None
1 1 power pole
2 2 power poles
A
ENCLOSURE
A Open
J
COIL
A
MODIFICATIONS
D 200-208V, 60 HZ
E 550-600V, 60 HZ
550V, 50 HZ
F 120V, 60 HZ
110V, 50 HZ
G 208-240V, 60 HZ
190-220V, 50 HZ
H 440-480V, 60 HZ
380-440V, 50 HZ
J 24V, 60 HZ
24V, 50 HZ
L 277V, 60 HZ
240V, 50 HZ
A Jumper Bar
* Class B coil
standard.
Binding head
screws and quad
quick connect
standard.
* Suffix 600R to
999R denotes
special modifications.
* Contact cover and
taped coil comes
standard.
* Other voltages
available. Please
contact sales office.
Class 42
D.P. CONTACTOR
42
CLASS
42 Contactor
(D.P.)
Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information
is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager.
B
AMP
RATING
A
B
C
D
E
F
G
H
I
25
30
40
50
60
75
90
120
150
F
MODEL
F
E*
*75 - 90
amp
only
3
POWER
POLES
1
2
3
6
2 power poles
4 power poles
3 power poles
2 NO & 1 NC
power poles
7 3 NO & 1 NC
power poles
8 2 NO & 2 NC
power poles
5
CONTROL
CIRCUIT
A
ENCLOSURE
5 Without
auxiliary
contact
A Open
B NEMA 1
C Open w/DIN
rail mtg.
base
J
COIL
A 110-120/
220-240V, 60 HZ
C 220-240/
440-480V, 60 HZ
F 110V, 50 HZ
120V, 60 HZ
G 190-220V, 50 HZ
208-240V, 60 HZ
J 24V, 50 HZ
24V, 60 HZ
H 380-440V, 50 Hz
440-480V, 60 HZ
E 550V, 50 Hz
550-600V, 60 HZ
L 240V, 50 HZ
277V, 60 HZ
D 200-208V, 60 HZ
K 200-230V, 50 HZ
200-230V, 60 HZ
OEM Use Only
1 F coil w/terms. Up
2 G coil w/terms. Up
3 J coil w/terms. Up
4 H coil w/terms. Up
5 E coil w/terms. Up
6 L coil w/terms. Up
7 D coil w/terms. Up
* Other voltages
available. Please
contact sales office.
P
POWER
TERMINALS
K
L
M
N
P
No screws w/QC’s
Binding head screws
Sems screws
Lugs
Binding head screws
w/QC’s
Q Sems screws w/QC’s
R Lugs w/QC’s
S Binding head screws
& aux. screws
T Sems screws & aux.
screws
V Lugs w/aux. screws
W Binding head screws
all locations. DQC
on line side only.
Y Sems screws all
locations. DQC on
line side only.
Z Lugs all locations
DQC on the line side
only.
B
INTERLOCKS
A
B
C
D
E
F
G
H
K
L
M
N
O
P
R
S
OMIT = “P” type
terminals on A & B
rated contactors, or
“R” type terminals
on C, D, E, F, & G
rated contactors.
1 SPDT left
1 NO left
1 NO & 1 NC left
1 NO & 1 NC both
left & right
2 SPDT right
1 NO & 1 NC left
2 SPDT left
2 SPDT right
1 NO left &
1 NO right
1 NC left &
1 NC right
2 SPDT left
1 SPDT right
1 NC right
1 NO right
1 NC left
1 NO left
1 NC right
1 NC left
1 NO right
1 SPDT left
1 SPDT right
Whenever an inlk is
specified, a power
term. must also be
specified in the
preceding field.
* A special three letter customer suffix will be assigned by the Product
Manager for additional modifications.
9/2
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Control
Definite Purpose Contactors
Class 42 & 45 general application
Class 45
45FG20AJ
45GG10AJA
45CG10AFA
45CG20AJ
Benefits
■
Power Termination Options
■
Quiet Operation
■
Compact Size
■
Weld-resistant Silver Cadmium Oxide Contacts
■
One Pole Version Includes Shunt Bar
■
Power Terminal Operations
■
Interchangeable Mounting Durable Metal Back Plate
■
Reinforced Thermalset Polyester Housing
■
Contact Covers Come Standard
■
Standard Class B Coil Insulation
Class 42
42AF35AF
42DF35AF
42FE35AF106
42HF35AF
Benefits
■
Compact Size
■
Weld-resistant Silver Cadmium Oxide Contacts
■
Interchangeable Mounting Durable Metal Back Plate
■
Optional Din Rail Mounting
■
Power Terminations Options
■
Snap-on Electrical/Mechanical Interlocks
■
Reinforced Thermalset Polyester Housing
■
Visual Contact Position Indication
■
Quiet Operation
■
Low VA Coils Standard for 25A–40A
Common Definite Purpose Applications
■
Air Conditioning
■
Elevators
■
Heating
■
Pool and Spa
■
Ventilating
■
Welding
■
Refrigeration
■
Pump and Compressor
■
Food and Beverage Industry
■
Conveyors
For further products and dimensions see the PDF file of the DP supplement catalog online.
Siemens Industry, Inc.
Industrial Controls Catalog
9/3
Definite Purpose Control
Definite Purpose Contactors
Class 42 & 45 part numbers
Ordering Information
Coil Table
䊳
Use complete catalog number. Replace the (*) with letter from the coil table
䊳
For additional information see www.sea.siemens.com/controls
60Hz
24
110–120
200–208
208–240
277
440–480
550–600
50Hz Voltage
24
110
—
190–220
240
380–440
550
Letter
J
F
D
G
L
H
E
Class 45
FLA
120V
Hp
240V
LRA
20
25
30
35
40
—
—
—
—
—
120
150
180
180
240
20
25
30
35
40
—
—
—
—
—
—
—
—
—
—
Hp
277V
LRA
—
—
—
—
—
110
150
180
180
240
—
—
—
—
—
120
150
180
200
240
Hp
480V
LRA
—
—
—
—
—
100
100
150
150
200
—
—
—
—
—
100
125
135
135
200
Hp
600V
LRA
—
—
—
—
—
80
80
120
120
160
—
—
—
—
—
80
100
110
110
160
Hp
Non
Inductive
Amps
Poles
Catalog No
—
—
—
—
—
25
35
40
50
55
1
1
1
1
1
45CG10A*A
45DG10A*A
45EG10A*A
45FG10A*A
45GG10A*A
40.
—
—
—
—
—
30
35
40
50
55
2
2
2
2
2
45CG20A*
45DG20A*
45EG20A*
45FG20A*
45GG20A*
59.
78.
85.
91.
96.
List Price $
49.
54.
Class 42 25–150 FLA 60Hz 600V AC Max
FLA
120V
Hp
240V
LRA
Hp
277V
LRA
Hp
480V
LRA
Hp
600V
LRA
Hp
Non
Inductive
Amps
Poles
Catalog No
25
25
25
2
—
—
150
150
150
3
5
5
—
—
—
—
—
—
125
125
125
—
7.5
7.5
100
100
100
—
7.5
7.5
35
35
35
2
3
4
42AF15A*
42AF35A*
42AF25A*
104.
141.
30
30
30
2
—
—
180
180
180
5
7.5
7.5
—
—
—
—
—
—
150
150
150
—
10
10
120
120
120
—
10
10
40
40
40
2
3
4
42BF15A*
42BF35A*
42BF25A*
109.
116.
1154.
40
40
40
3
—
—
240
240
240
7.5
10
10
—
—
—
—
—
—
200
200
200
—
15
15
160
160
160
—
15
15
50
50
50
2
3
4
42CF15A*
42CF35A*
42CF25A*
122.
136.
176.
50
50
3
—
300
300
10
15
—
—
—
—
250
250
—
30
200
200
—
30
63
63
2
3
42DF15A*
42DF35A*
253.
268.
60
60
5
—
360
360
10
20
—
—
—
—
300
300
—
40
240
240
—
40
75
75
2
3
42EF15A*
42EF35A*
286.
298.
75
75
—
—
450
450
25
25
—
—
—
—
375
375
—
40
300
300
—
40
93
93
2
3
42FE15A*106
42FE35A*106
343.
383.
90
90
—
—
540
540
—
30
—
—
—
—
450
450
—
60
360
360
—
60
120
120
2
3
42GE15A*106
42GE35A*106
443.
479.
120
120
—
—
720
720
—
—
—
—
—
—
600
600
—
—
480
480
—
—
150
150
2
3
42HF15A*
42HF35A*
543.
591.
150
150
—
—
900
900
—
—
—
—
—
—
750
750
—
—
600
600
—
—
160
160
2
3
42IF15A*
42IF35A*
1048.
1156.
9/4
Product Category: Definite Purpose
List Price $
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Control
Definite Purpose Contactors
Class 42
Modifications
Modifications
and
& Accessories
accessories
Field Modification Kits
Description
Class
42
Contactor FLA
25 - 60
Snap-on Side Mounted
Auxiliary Contacts
Auxiliary Contacts
Catalog Number
1 NO
49ACR0
1 NC
49ACRC
1 NO & 1 NC
2 NO
49ACR6
49ACR7
2 NC
49ACR8
1 SPDT
49D36098001
2 SPDT
49D36098003
1 NO
49D22125001
49D22125002
42
75 - 90
1 NC
1 SPDT
49CE42SPDT
42
120 - 150
1 NO
49D54682N0
1 NC
49D54682NC
Mechanical Interlock
42
25 - 60
—
49D70035001
DIN Rail Kit
42
25 - 40
—
49D57071001
50 - 60 & 4-pole
—
49D57071002
25 - 60
—
49EA42BEB
75 - 90
—
49EA42GEB
Enclosure Only
42
List Price $
No replacement parts are available for the Class 45 contactors.
One per side is all you can add in the field of the Snap-on Side Mounted Auxiliary Contacts through 90 amp.
Factory Assembled Modifications
Description
Class
Contactor FLA
Coil Suffix Letter
Lugs (each terminal)
45
20 - 40
L1
Clamp Screw (each terminal)
45
20 - 40
L3
Siemens Industry, Inc.
Industrial Controls Catalog
List Price $
9/5
Definite Purpose Control
Definite Purpose Starters
Selection
Class
16 product nomenclature
Class 16
D.P. STARTER
16
CLASS
16 Starter
9/6
Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information
is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager.
B
AMP RATING
A
B
C
D
E
F
G
H
I
25
30
40
50
60
75
90
120
150
F
MODEL
3
POWER POLES
F
E*
1 2 power poles
2 4 power poles
3 3 power poles
*75 -90
amp only
5
A
CONTROL CIRCUIT ENCLOSURE
2 Auxiliary contact,
left (NO pole for
3-Wire remote
push button)
5 Without auxiliary
contact
A Open
B NEMA 1
J
COIL
A 110-120/
220-240V, 60 HZ
C 200-240/
440-480V, 60 HZ
F 110V, 50 HZ
120V, 60 HZ
G 190-220V, 50 HZ
208-240V, 60 HZ
J 24V, 50 HZ
24V, 60 HZ
H 380-440V, 50 HZ
440-480V, 60 HZ
E 550V, 50 HZ
550-600V, 60 HZ
L 240V, 50 HZ
277V, 60 HZ
D 200-208V, 60 HZ
K 200-230V, 50 HZ
200-230V, 60 HZ
4
OVERLOAD
4 3-phase comp.
bimetal w/NC
contacts
8 Single phase
comp. bimetal
w/NC contacts
—
—
—
Optional Suffixes
* Special three letter
suffix for factory
modifications
assigned by Product
Marketing Manager.
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Control
Definite Purpose Starters
Class 16 general application
Selection
Class 16
16HF35AF81
16CF35AF4
16EF35AF4
Definite Purpose Starter Features
■
Class 42 Contactor Construction Features
■
Dependable Overload Relays available in both Class 10 and Class 20 Trip
■
Common Mounting Configurations and Dimensions 25 – 60A
■
Dual Voltage Coils Available – Contact Sales Office
■
NEMA 1 Enclosures Available as a field modification
■
Starters Available from 25-150 Amp
■
Various configurations can be factory modified - Contact Sales Office
Siemens Industry, Inc.
Industrial Controls Catalog
9/7
Definite Purpose Control
Definite Purpose Starters
Selection
Class
16 part numbers
Coil Voltages Table
Ordering Instructions
䊳
Use complete catalog number
䊳
Replace the (*) with letter from coil table
䊳
Modifications are available on page 9/9
Locked Rotor Amps
FLA
240V
480V
600V
Definite Purpose Starters, 25 - 40 FLA 60 Hz 600VAC Max
25
30
40
150
180
240
125
150
200
60
300
360
250
300
120
160
75
90
450
540
375
450
240
150
9/8
720
900
600
300
360
750
460
600
J
F
D
G
L
H
E
A
—
C
Catalog Number
List Price $
2
—
16AF15A*8
2
1
16AF12A*8
3
—
16AF35A*4
3
1
16AF32A*4
4
—
16AF25A*4
2
—
16BF15A*8
2
1
16BF12A*8
3
—
16BF35A*4
3
1
16BF32A*4
4
—
16BF25A*4
2
—
16CF15A*8
2
1
16CF12A*8
3
—
16CF35A*4
3
1
16CF32A*4
4
—
16CF25A*4
2
—
16DF15A*8
2
1
16DF12A*8
3
—
16DF35A*4
3
1
16DF32A*4
2
—
16EF15A*8
2
1
16EF12A*8
3
—
16EF35A*4
3
1
16EF32A*4
(Open Type Starters Bimetal Overloads)
Definite Purpose Starters, 120 - 150 FLA 60 Hz 600VAC Max
120
Letter
24
110
—
190-220
240
380-440
550
—
(Open Type Starters with Bimetal Overloads)
200
Definite Purpose Starters, 75 - 90 FLA 60 Hz 600VAC Max
Normally Open
Auxiliary Contact
50 Hz
24
110-120
200-208
208-240
277
440-480
550-600
110-120/
220-240
200-240/
440-480
(Open Type Starters with Bimetal Overloads)
100
Definite Purpose Starters, 50 - 60 FLA 60 Hz 600VAC Max
50
Poles
60 Hz
3
—
16FE35A*81
3
1
16FE32A*81
3
—
16GE35A*81
3
1
16GE32A*81
(Open Type Starters)
3
—
16HF35A*81
3
1
16HF32A*81
3
—
16IF35A*81
3
1
16IF32A*81
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Control
Definite Purpose Starters
Class 16 modifications and accessories
Selection
Field Modification Kits
Description
Class
16
Contactor FLA
25 - 60
Snap-on Side Mounted
Auxiliary Contacts
16
Enclosure Only
75 - 90
Auxiliary Contacts
Catalog Number
1 NO
49ACR0
1 NC
49ACRC
1 NO & 1 NC
2 NO
49ACR6
49ACR7
2 NC
49ACR8
1 SPDT
49D36098001
2 SPDT
49D36098003
1 NO
49D22125001
1 NC
49D22125002
1 SPDT
49CE42SPDT
1 NO
49D54682N0
16
120 - 150
1 NC
49D54682NC
16
25 - 60
—
49EA16CEB
75 - 90
—
49EA16EEB
List Price $
One per side is all you can add in the field of the Snap-on Side Mounted Auxiliary Contacts through 90 amp.
To order a starter in a NEMA 1 enclosure, change
the 7th character of the catalog number to a B.
EXAMPLE: 16CF35AF in a NEMA 1 enclosure is 16CF35BF.
Contact Sales Office For Pricing.
Siemens Industry, Inc.
Industrial Controls Catalog
9/9
Definite Purpose Control
Definite Purpose Contactors
Selection
Class
16 & 42 replacement parts
AC Coils
Class 16, 41
Insert
75D54760F
Third
Character
of Cat. No.
N
Fourth
Character
of Cat. No.
B
Volts 60 Hz
Volts 50 Hz
Catalog
Number
24
24
75D54760J
110-120
110
75D54760F
200-208
—
75D54760D
208-240
208-220
75D54760G
277
240
75D54760L
440-480
380-440
75D54760H
550-600
550
75D54760E
Volts 60 Hz
Volts 50 Hz
Catalog
Number
24
24
75D70646J
110-120
110
75D70646F
200-208
—
75D70646D
208-240
190-220
75D70646G
277
240
75D70646L
440-480
380-440
75D70646H
550-600
550
75D70646E
120-240
110-220
75D70556001
240-280
220-440
75D70556002
24
24
75D54772J
110-120
110
75D54772F
200-208
—
75D54772D
208-240
208-220
75D54772G
277
240
75D54772L
440-480
380-440
75D54772H
550-600
550
75D54772E
24
24
75D73251J
110-120
110
75D73251F
110-120/220-240
110/190-120
75D73251A
200-208
—
75D73251D
208-240
190-220
75D73251G
277
240
75D73251L
220-240/440-480
190-220/380-440
75D73251C
440-480
380-440
75D73251H
550-600
550
75D73251E
List Price $
Class 16, 34, 42, 44
Insert
75D70646J
75D54772F
75D73251F
Third
Character
of Cat. No.
A, B, C, D, E
F, G
H, I
Fourth
Character
of Cat. No.
F
E
F
List Price $
Replacement coils are standard VA coils with screw terminals.
Replacement coils with quick connects are available for 25-60 amp contactors. Contact Sales Office for part number.
9/10
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Control
Definite Purpose Contactors
Class 16 & 42 replacement parts
Contact Kits (Contains 1 Complete Pole)
Class 16, 42
Third Character
of Cat. No.
Fourth Character
of Cat. No.
Catalog Number
A
F
75AF42
B
F
75BF42
C
F
75CF42
D
F
75DF42
E
F
75EF42
F
E
75FE42
G
E
75GE42
H
F
75HF14
I
F
75IF14
List Price $
Overload Relays
Ambient Compensated Bimetal Class 16
Third Character
of Cat. No.
Fourth Character
of Cat. No.
Number
of Poles
Catalog Number
A, B
F
1
48DH18A6
3
48DH38A6
C
F
1
48EH18A6
3
48EH38A6
D, E
F
1
48GH18AA6
3
48GH38A6
3
48HC38AA2
3
48IC38AA6
H
I
Siemens Industry, Inc.
Industrial Controls Catalog
F
List Price $
9/11
Definite Purpose Controls
Overload Relay Heater Tables
Class 16 starters, Class 48 overloads
Selection of Heater Elements for Overload Relays
Overload relays do not provide protection against short circuits. To insure proper coordination with short circuit protective devices,
select heaters from the information packaged with the control.
Selection Instructions
To select the proper heater follow the steps below:
1. Choose the proper table using the size, trip type, and number of poles
Ambient Compensated Bimetal Heater Element Tables
Size
Class
FLA
3rd Letter of
Catalog No.
16
25 - 90
120 - 150
A-G
H-I
Standard Trip (Class 20)
Quick Trip (Class 10)
E Heaters Green Reset
2 Poles
3 Poles
K Heaters Green Reset
2 Poles
3 Poles
295
—
395
—
297
299
398
393
2. If you do not know the trip amps, use the motor FLA to calculate the trip amps by multiplying the FLA by a factor of 1.15
3. Match the trip amps of your starter to the trip amps value below the starter size of the appropriate table. The choice should be as
close as possible but NOT greater than the selected trip amp value in the table to allow for proper protection.
4. Select the proper heater from the last column and order the appropriate number of heaters (single phase requires at least two,
three phase requires at least three).
Examples
Starter
Size Starter
Phase
Trip
Heater Table
Motor FLA
Trip Amps
Heater Element
16CF15AF8
16EF35AF4
40
60
Single
Three
Standard
Quick
295
398
35
56
40.25
64.40
E69
K77
5th character in the catalog number equals 1 for single phase 2 pole or 3 for three phase 3 pole.
For 40 degrees C motors, the maximum Trip Amps are 115% of the Motor FLA or TRIP AMPS = FLA*1.15.
9/12
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Controls
Overload Relay Heater Tables
Tables 295, 297, 299
Trip amps
Table 295
Table 297
Size FLA
25, 30
40
Size FLA
25,30
40
.67
.73
.81
.88
.96
1.05
1.11
1.20
1.33
1.43
1.54
1.81
2.07
2.30
2.59
2.86
3.02
3.29
3.48
3.81
4.25
4.51
4.85
5.27
5.72
6.40
7.15
7.78
8.56
9.43
9.93
10.3
11.4
12.6
13.8
15.2
16.4
17.6
19.1
21.7
25.0
28.5
30.0
33.6
39.0
45.0
47.6
55.0
50,60
Heater
Code
25.4
29.0
30.6
34.3
39.9
46.1
48.8
56.4
58.0
64.0
69.0
81.0
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E72
E73
E74
E76
E77
.36
.40
.44
.47
.51
.55
.61
.67
.72
.78
.83
.91
1.01
1.07
1.16
1.25
1.36
1.55
1.72
1.93
2.12
2.26
2.43
2.60
2.83
3.18
3.37
3.61
3.93
4.26
4.77
5.32
5.78
6.37
7.02
7.40
7.70
8.38
9.43
10.3
11.2
12.3
13.1
15.1
17.1
19.6
21.4
23.1
24.8
27.4
30.6
32.5
36.8
39.5
50.0
55.0
50,60
22.5
25.4
27.1
29.0
32.0
34.0
38.0
42.0
49.0
54.0
57.5
65.0
73.0
82.0
Table 299
75,90
48.4
50.0
55.0
59.5
68.0
72.5
77.0
87.0
95.0
103.0
115.0
Siemens Industry, Inc.
Industrial Controls Catalog
Heater
Code
E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E72
E73
E74
E76
E77
E78
E79
E80
E81
E94
E96
E97
Size FLA
120,150 180
H, I
J
270, 360 650
R, K
M
110
123
136
143
154
164
176
195
207
222
242
262
292
326
354
372
409
427
470
37.5
42.0
45.6
49.6
54.6
58.3
64.6
68.1
72.6
78.9
84.7
90.6
100
110
115
121
124
130
138
151
157
168
180
68.0
71.0
78.0
84.0
89.5
97.0
106
111
118
126
135
147
160
177
193
210
215
242
268
307
330
351
380
406
438
469
510
551
598
648
700
755
Heater
Code
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E50
E51
E69
E70
E71
E73
E73A
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
E106
E107
E108
9/13
Definite Purpose Controls
Overload Relay Heater Tables
Tables 393, 395, 398
Trip amps
Table 393
Table 395
Size FLA
120,150 180
H, I
J
Size FLA
25, 30
40
50.1
53.1
58.0
62.1
65.5
72.0
80.0
85.0
93.0
97.5
104
114
126
136
150
162
180
190
200
116
130
142
160
180
205
225
270, 360 650
R, K
M
Heater
Code
122
134
145
156
171
187
201
215
241
259
286
308
335
383
412
465
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K72
K73
K74
K75
K76
K77
K78
K83
K85
K86
K87
K88
K89
K90
K92
K93
K94
K96
K97
260
288
315
338
372
407
444
497
540
582
643
708
775
860
2.29
2.55
2.70
3.06
3.39
3.70
4.01
4.41
4.75
5.23
5.71
6.12
6.65
7.51
8.00
8.60
9.52
10.1
11.2
11.6
13.6
14.3
15.3
16.6
17.5
19.2
20.3
21.7
25.0
26.8
29.2
31.0
35.0
37.2
41.6
42.8
47.2
50.2
55.3
Table 398
50,60
Heater
Code
24.9
26.7
30.7
32.3
36.0
37.8
41.8
45.6
50.8
53.6
56.5
60.0
65.5
70.5
74.0
81.5
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
Size FLA
25,30
40
1.91
2.08
2.26
2.44
2.70
2.98
3.22
3.61
3.93
4.23
4.67
5.02
5.46
6.25
6.74
7.25
8.05
8.55
9.8
10.3
12.0
12.5
13.6
14.7
15.5
16.9
17.9
19.1
22.0
23.6
25.2
27.0
30.0
34.0
37.1
41.0
46.0
49.2
56.0
50,60
22.5
24.1
25.7
28.0
31.1
34.6
37.8
41.5
50.0
54.0
57.0
60.0
66.0
73.0
80.0
75,90
50.2
53.2
58.0
62.2
65.5
72.0
80.0
85.0
93.0
97.5
104.0
119.0
9/14
Heater
Code
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K69
K70
K72
K73
K74
K75
K76
K77
K78
K79
K83
K85
K86
K87
K89
Siemens Industry, Inc.
Industrial Controls Catalog
Definite Purpose Controls
D.P. Cross Reference
Poles Amps Volts
SIEMENS
Cutler Hammer Arrow Hart
ABB
Allen Bradley Joslyn Clark
Fasco
General Electric
Square D
Steveco
Products Unlimited
(OEM)
1
25
24
45DG10AJA
C25CNB125T
C251NU10
–
400-DP25NJ1
A77-306654A-3 1S25-A
CR453CB3HAA
8910DP21V14
94385
3100-15Q1
–
25
120
45DG10AFA
C25CNB125A
C251NU20
–
400-DP25ND1 A77306654A-1 1S25-B
CR453CB3AAA
8910DP21V02
94386
3100-15T1
–
25
208/240 45DG10AGA
C25CNB125B
C251NU30
–
400-DP25NA1 A77-306654A-2 1S25-C
CR453CB3BAA
8910DP21V09
94387
3100-15U1
1
30
24
45EG10AJA
C25CNB130T
C301NU10
DP30C1P-F 400-DP30NJ1
CR453CC3HAA
8910DP31V14
94388
3100-15Q2
3100-15T2
A77-306653A-3 1S30-A
–
30
120
45EG10AFA
C25CNB130A
C301NU20
DP30C1P-1 400-DP30ND1 A77-306653A-1 1S30-B
CR453CC3AAA
8910DP31V02
94389
–
30
208/240 45EG10AGA
C25CNB130B
C301NU30
DP30C1P-2 400-DP30NA1 A77-3066531-2 1S30-C
CR453CC3BAA
8910DP31V09
94390
3100-15U2
1
40
24
45GG10AJA
C25CNB140T
–
–
–
8910DP41V14
–
3100-15Q19
–
–
–
–
40
120
45GG10AFA
C25CNB140A
–
–
–
–
–
–
8910DP41V02
–
3100-15T19
–
40
208/240 45GG10AGA
C25CNB140B
–
–
–
–
–
–
8910DP41V09
–
3100-15U19
2
20
24
45CG20AJ
C25BNB220T
C202U10
–
–
A77-306680A-3 2S20-A
CR453CA2HAA
8910DP12V14
90234
3100-20Q3
–
20
120
45CG20AF
C25BNB220A
C202U20
–
–
A77-306680A-1 2S20-B
CR453CA2AAA
8910DP12V02
90235
3100-20T3
–
20
208/240 45CG20AG
C25BNB220B
C202U30
–
–
A77-306680A-2 2S20-C
CR453CA2BAA
8910DP12V09
90236
3100-20U3
–
20
277
45CG20AL
C25BNB220H
–
–
–
–
CR453CA2FAA
8910DP12V04
–
3100-20V3
–
2
30
24
45EG20AJ
C25BNB23OT
C302U10
–
400-DP30NJ2
A77-306657A-3 2S30-A
CR453CC2HAA
8910DPA32V14
90244
3100-20Q6
–
30
120
45EG20AF
C25BNB23OA
C302U20
–
400-DP30ND2 A77-306657A-1 2S30-B
CR453CC2AAA
8910DPA32V02
90245
3100-20T6
–
30
208/240 45EG20AG
C25BNB23OB
C302U30
–
400-DP30NA2 A77-306657A-2 2S30-C
CR453CC2BAA
8910DPA32V09
90246
3100-20U6
–
30
277
45EG20AL
C25BNB230H
C302050
–
400-DP30NF2
–
–
CR453CC2FAA
8910DPA32V04
–
3100-20V6
2
40
24
45GG20AJ
C25BNB240T
CA01NU10
–
–
–
–
CR453CE2HBB
8910DP42V14
–
3100-20Q18
–
40
120
45GG20AF
C25BNB240A
CA01NU20
–
–
–
–
CR453CE2ABB
8910DP42V02
–
3100-20T18
–
40
208/240 45GG20AG
C25BNB240B
CA01NU30
–
–
–
–
CR453CE2BBB
8910DP42V09
–
3100-20U18
–
3
25
24
42AF35AJ
C25DND325T
ACC230UM10 –
400-DP25NJ3
3M25-A CR453AB3HAA
8910DPA23V14
90160
3100-30Q8
–
25
120
42AF35AF
C25DND325A
ACC230UM20 –
400-DP25ND3 –
3M25-B
CR453AB3AAA
8910DPA23V02
90161
3100-30T8
–
25
208/240 42AF35AG
C25DND325B
ACC230UM30 –
400-DP25NA3 –
3M25-C CR453AB3BAA
8910DPA23V09
90162
3100-30U8
3
30
24
42BF35AJ
C25DND330T
ACC330UM10 DP30C3P-F 400-DP30NJ3
A77-309044A-3 3M30-A CR453AC3HAA
8910DPA33V14
90163
3100-30Q9
–
30
120
42BF35AF
C25DND330A
ACC330UM20 DP30C3P-1 400-DP30ND3 A77-309044A-1 3M30-B
CR453AC3AAA
8910DPA33V02
90164
3100-30T99
–
30
208/240 42BF35AG
C25DND330B
ACC330UM30 DP30C3P-2 400-DP30NA3 A77-309044A-2 3M30-C CR453AC3BAA
8910DPA33V03
90165
3100-30U9
3
40
24
42CF35AJ
C25DNF340T
ACC430UM10 DP40C4P-F 400-DP40NJ3
8910DPA43V14
90170
3100-30Q10
–
40
120
42CF35AF
C25DNF340A
ACC430UM20 DP40C4P-1 400-DP40ND3 A77-309046A-1 3M40-B
CR453AD3ABB
8910DPA43V02
90171
3100-30T10
–
40
208/240 42CF35AG
C25DNF340B
ACC430UM30 DP40C4P-2 400-DP40NA3 A77-309046A-2 3M40-C CR453AD3BBB
8910DPA43V09
90172
3100-30U10
3100-30Q16
A77-309046A-3 3M40-A CR453AD3HBB
3
50
24
42DF35AJ
C25FNF350T
ACC530U10
–
400-DP50NJ3
A77-288514A-3 3L50-A
CR353FE3BH1
8910DPA53V14
92459
–
50
120
42DF35AF
C25FNF350A
ACC530U20
–
400-DP50ND3 A77-288514A-1 3L50-B
CR353FE3BA1
8910DPA53V02
92460
3100-30T16
–
50
208/240 42DF35AG
C25FNF350B
ACC530U30
–
400-DP50NA3 A77-288514A-2 3L50-C
CR353FE3BB1
8910DPA53V09
92461
3100-30U16
3
60
24
42EF35AJ
C25FNF360T
ACC630U10
DP60C3P-F 400-DP60NJ3
A77-288517A-3 3L60-A
CR353FF3BH1
8910DPA63V14
92462
3100-30Q17
–
60
120
42EF35AF
C25FNF360A
ACC630U20
DP60C3P-1 400-DP60ND3 A77-288517A-1 3L60-B
CR353FF3BA1
8910DPA63V02
92463
3100-30T17
–
60
208/240 42EF35AG
C25FNF360B
ACC630U30
DP60C3P-2 400-DP60NA3 A77-288517A-2 3L60-C
CR353FF3BB1
8910DPA63V09
92464
3100-30U17
3186-30I75
3
75
24
42FE35AJ106
C25FNF375T
ACC730U10
–
400-DP75NJ3
A77-288520A-3 –
CR353EG3BH1
8910DPA73V14
92465
–
75
120
42FE35AF106 C25FNF375A
ACC730U20
–
400-DP75ND3 A77-288520A-1 –
CR353EG3BA1
8910DPA73V02
92467
3186-30J75
–
75
208/240 42FE35AG106 C25FNF375B
ACC730U30
–
400-DP75NA3 A77-288520A-2 –
CR353EG3BB1
8910DPA73V09
92468
3186-30K75
3
90
24
42GE35AJ106 C25GNF390T
–
–
–
–
–
CR353EH3BH1
8910DPA93V14
92469
3186-30I90
–
90
120
42GE35AF106 C25GNF390A
ACC930U20
–
–
–
–
CR353EH3BA1
8910DPA93V02
–
3186-30J90
–
90
208/240 42GE35AG106 C25GNF390B
ACC930U30
–
–
–
–
CR353EH3BB1
8910DPA93V09
–
3186-30K90
3
120
24
42HF35AJ
C25HNE3120T
–
–
–
–
–
CR353GJ3AH1
8910DPA123V14
–
3100-30Q12
–
120
120
42HF35AF
C25HNF3120A
ACC1230U20 –
–
–
–
CR353GJ3AA1
8910DPA123V02
–
3100-30T12
–
120
208/240 42HF35AG
C25HNF3120B
ACC1230U20 –
–
–
–
CR353GJ3AB1
8910DPA123V09
–
3100-30U12
4
40
24
42CF25AJ
C25ENF440T
ACC440UM10 –
–
–
–
CR353AD4BH1
8910DPA44V14
–
3100-40Q10
–
40
120
42CF25AF
C25ENF440A
ACC440UM20 –
–
–
–
CR353AD4BA1
8910DPA44V02
–
3100-40T10
–
40
208/240 42CF25AG
C25ENF440B
ACC440UM30 –
–
–
–
CR353AD4BB1
8910DPA44V09
–
3100-40U10
This cross reference does not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the
local Siemens Energy & Automation Controls sales office.
The contents of this cross reference shall not become part or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens Energy & Automation, Inc. The warranty contained in the
contract between the parties is the sole warranty of Siemens Energy & Automation, Inc. Any statements contained herein do
not create new warranties or modify the existing warranty.
Siemens Industry, Inc.
Industrial Controls Catalog
9/15
Definite Purpose Controls
Notes
9/16
Siemens Industry, Inc.
Industrial Controls Catalog