0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6EP34337SB000AX0

6EP34337SB000AX0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 24V 120W

  • 数据手册
  • 价格&库存
6EP34337SB000AX0 数据手册
Data sheet 6EP3433-7SB00-0AX0 SITOP PSU6200/3AC/24VDC/5A SITOP PSU6200 24 V/5 A stabilized power supply input: 400 - 500 V AC output: 24 V DC/5 A Input type of the power supply network 3-phase AC or DC supply voltage at AC ● minimum rated value 400 V ● maximum rated value 500 V ● initial value 323 V ● full-scale value 576 V input voltage ● at DC 450 ... 600 V operating condition of the mains buffering at Vin = 400 V buffering time for rated value of the output current in the event of power failure minimum 20 ms operating condition of the mains buffering at Vin = 400 V line frequency ● 1 rated value 50 Hz ● 2 rated value 60 Hz line frequency 47 ... 63 Hz input current ● at rated input voltage 400 V 0.33 A ● at rated input voltage 500 V 0.28 A current limitation of inrush current at 25 °C maximum 22 A fuse protection type ● in the feeder three-poled coupled circuit breaker from 4 A characteristic C to 10 A characteristic C or circuit breaker 3RV2011-1EA10 (setting 4 A) or 3RV2711-1ED10 (UL 489) Output voltage curve at output Controlled, isolated DC voltage number of outputs 1 output voltage at DC rated value 24 V output voltage ● at output 1 at DC rated value 24 V relative overall tolerance of the voltage 3% relative control precision of the output voltage ● on slow fluctuation of input voltage 0.6 % ● on slow fluctuation of ohm loading 0.6 % residual ripple ● maximum 30 mV ● typical 20 mV voltage peak ● maximum 30 mV 6EP34337SB000AX0 Page 1/3 7/5/2022 Subject to change without notice © Copyright Siemens ● typical 20 mV adjustable output voltage 24 ... 28 V product function output voltage adjustable Yes type of output voltage setting via potentiometer; max. 120 W (144 W up to 45°C) display version for normal operation Green LED for 24 V OK type of signal at output Electronic contact (NO contact, contact rating 30 V DC/0.1 A) for DC O.K. or diagnostic interface behavior of the output voltage when switching on Overshoot of Vout < 2 % response delay maximum 0.5 s voltage increase time of the output voltage ● typical 100 ms output current ● rated value 5A ● rated range 0 ... 5 A; 6 A up to +45°C; +60 ... +70 °C: Derating 3%/K supplied active power typical 120 W short-term overload current ● on short-circuiting during the start-up typical 6A ● at short-circuit during operation typical 6A product feature ● bridging of equipment No Efficiency efficiency in percent 91.2 % power loss [W] ● at rated output voltage for rated value of the output current typical 11 W ● during no-load operation maximum 2W Closed-loop control relative control precision of the output voltage at load step of resistive load 10/90/10 % typical 2% setting time ● load step 10 to 90% typical 1 ms ● load step 90 to 10% typical 1 ms ● maximum 2 ms Protection and monitoring design of the overvoltage protection < 32 V response value current limitation typical 6A property of the output short-circuit proof Yes design of short-circuit protection Shutdown and periodic restart attempts overcurrent overload capability in normal operation overload capability 150 % Iout rated up to 5 s/min Safety galvanic isolation between input and output Yes galvanic isolation Safety extra low output voltage Vout according to EN 60950-1 operating resource protection class Class I leakage current ● maximum protection class IP 3.5 mA IP20 Approvals certificate of suitability ● CE marking Yes ● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) ● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) ● cCSAus, Class 1, Division 2 No ● ATEX No certificate of suitability ● IECEx No ● NEC Class 2 No ● ULhazloc approval No ● FM registration No type of certification CB-certificate 6EP34337SB000AX0 Page 2/3 Yes 7/5/2022 Subject to change without notice © Copyright Siemens certificate of suitability ● EAC approval Yes ● KC approval No ● C-Tick No ● Regulatory Compliance Mark (RCM) No certificate of suitability shipbuilding approval No shipbuilding approval in process: DNV GL, ABS Marine classification association ● American Bureau of Shipping Europe Ltd. (ABS) No ● French marine classification society (BV) No ● DNV GL No ● Lloyds Register of Shipping (LRS) No ● Nippon Kaiji Kyokai (NK) No EMC standard ● for emitted interference EN 55022 Class B ● for mains harmonics limitation EN 61000-3-2 ● for interference immunity EN 61000-6-2 environmental conditions ambient temperature ● during operation -30 ... +70 °C; with natural convection a monotonically increasing startup from -25 °C, safe start-up from -40 °C ● during transport -40 ... +85 °C ● during storage -40 ... +85 °C environmental category according to IEC 60721 Climate class 3K3, 5 … 95% no condensation Mechanics type of electrical connection Push-in terminals ● at input L1, L2, L3, PE: PushIn for 0.5 ... 6 mm² ● at output +1, +2, -1, -2, -3: PushIn for 0.5 ... 2.5 mm² ● for auxiliary contacts 13, 14 (alarm signal): 1 push-in terminal each for 0.2 ... 1.5 mm² width of the enclosure 35 mm height of the enclosure 135 mm depth of the enclosure 125 mm required spacing ● top 45 mm ● bottom 45 mm ● left 0 mm ● right 0 mm net weight 0.7 kg product feature of the enclosure housing can be lined up Yes fastening method Snaps onto DIN rail EN 60715 35x7.5/15 electrical accessories Buffer module, redundancy module mechanical accessories Identification labels SIMATIC ET 200SP 6ES7193-6LF30-0AW0 other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) 6EP34337SB000AX0 Page 3/3 7/5/2022 Subject to change without notice © Copyright Siemens
6EP34337SB000AX0 价格&库存

很抱歉,暂时无法提供与“6EP34337SB000AX0”相匹配的价格&库存,您可以联系我们找货

免费人工找货