0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6EP3437-8SB00-0AY0

6EP3437-8SB00-0AY0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 6EP3437-8SB00-0AY0 - AC/DC DIN Rail Power Supply (PSU), ITE & Electronic Equipment, 1 Outp...

  • 数据手册
  • 价格&库存
6EP3437-8SB00-0AY0 数据手册
Data sheet 6EP3437-8SB00-0AY0 SITOP PSU8200/3AC/24VDC/40A SITOP PSU8200 24 V/40 A stabilized power supply input: 400-500 V 3 AC output: 24 V DC/40 A input type of the power supply network 3-phase AC supply voltage at AC ● minimum rated value 400 V ● maximum rated value 500 V ● initial value 320 V ● full-scale value 575 V wide range input Yes buffering time for rated value of the output current in the event of power failure minimum 10 ms operating condition of the mains buffering at Vin = 400 V line frequency 50/60 Hz line frequency 45 ... 65 Hz input current ● at rated input voltage 400 V 2.1 A ● at rated input voltage 500 V 1.7 A current limitation of inrush current at 25 °C maximum 13 A I2t value maximum 2.24 A²·s fuse protection type none fuse protection type in the feeder Required: 3-pole connected miniature circuit breaker 10 ... 16 A characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) output voltage curve at output Controlled, isolated DC voltage output voltage at DC rated value 24 V output voltage ● at output 1 at DC rated value 24 V output voltage adjustable Yes; via potentiometer adjustable output voltage 24 ... 28 V; max. 960 W relative control precision of the output voltage ● on slow fluctuation of input voltage 0.1 % ● on slow fluctuation of ohm loading 0.2 % residual ripple ● maximum 100 mV voltage peak ● maximum 240 mV display version for normal operation Green LED for 24 V OK type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" behavior of the output voltage when switching on minimal overshooting (< 2 %) response delay maximum 0.1 s voltage increase time of the output voltage 6EP34378SB000AY0 Page 1/4 5/24/2024 Subject to change without notice © Copyright Siemens ● maximum 100 ms output current ● rated value 40 A ● rated range 0 ... 40 A; +60 ... +70 °C: Derating 4%/K supplied active power typical 960 W short-term overload current ● at short-circuit during operation typical 120 A duration of overloading capability for excess current ● at short-circuit during operation 25 ms constant overload current ● on short-circuiting during the start-up typical 44 A bridging of equipment Yes; switchable characteristic number of parallel-switched equipment resources for increasing the power 2 efficiency efficiency in percent 94 % power loss [W] ● at rated output voltage for rated value of the output current typical 66 W ● during no-load operation maximum 4W closed-loop control relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 1% relative control precision of the output voltage load step of resistive load 50/100/50 % typical 3% setting time ● maximum 10 ms protection and monitoring design of the overvoltage protection < 31.8 V property of the output short-circuit proof Yes design of short-circuit protection Alternatively, constant current characteristic approx. 44 A or latching shutdown ● typical 44 A overcurrent overload capability ● in normal operation overload capability 150 % Iout rated up to 5 s/min enduring short circuit current RMS value ● typical display version for overload and short circuit 50 A LED yellow for "overload", LED red for "latching shutdown" safety galvanic isolation between input and output Yes galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 operating resource protection class Class I leakage current ● maximum 1 mA ● typical 0.6 mA protection class IP IP20 standard ● for emitted interference EN 55022 Class B ● for mains harmonics limitation EN 61000-3-2 ● for interference immunity EN 61000-6-2 standards, specifications, approvals certificate of suitability ● CE marking Yes ● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) ● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) ● EAC approval Yes ● Regulatory Compliance Mark (RCM) Yes ● NEC Class 2 No ● SEMI F47 Yes type of certification ● BIS 6EP34378SB000AY0 Page 2/4 Yes; R-41183539 5/24/2024 Subject to change without notice © Copyright Siemens ● CB-certificate MTBF at 40 °C Yes 517 015 h standards, specifications, approvals hazardous environments certificate of suitability ● IECEx No ● ATEX No ● ULhazloc approval No ● cCSAus, Class 1, Division 2 No ● FM registration No standards, specifications, approvals marine classification shipbuilding approval Yes Marine classification association ● American Bureau of Shipping Europe Ltd. (ABS) Yes ● French marine classification society (BV) No ● Det Norske Veritas (DNV) Yes ● Lloyds Register of Shipping (LRS) No standards, specifications, approvals Environmental Product Declaration Environmental Product Declaration Yes Global Warming Potential [CO2 eq] ● total 2 118.7 kg ● during manufacturing 52 kg ● during operation 2 065.2 kg ● after end of life 0.74 kg ambient conditions ambient temperature ● during operation -25 ... +70 °C; With natural convection ● during transport -40 ... +85 °C ● during storage -40 ... +85 °C environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation connection method type of electrical connection screw terminal ● at input L1, L2, L3, PE: 1 screw terminal each for 0.5 ... 4 mm² single-core/finely stranded ● at output +: 2 screw terminals each for 0.5 ... 16 mm²; -: 3 screw terminals each for 0.5 ... 16 mm² ● for auxiliary contacts 13, 14 (alarm signal), 15, 16 (Remote): 1 screw terminal each for 0.05 ... 2.5 mm² mechanical data width × height × depth of the enclosure 135 × 150 installation width × mounting height 135 mm required spacing ● top 40 mm ● bottom 40 mm ● left 0 mm ● right 0 mm fastening method Snaps onto DIN rail EN 60715 35x15 ● standard rail mounting Yes ● S7 rail mounting No ● wall mounting No housing can be lined up Yes net weight 3.3 kg accessories electrical accessories Buffer module mechanical accessories Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20 further information internet links internet link ● to website: Industry Mall https://mall.industry.siemens.com ● to web page: selection aid TIA Selection Tool https://siemens.com/tst ● to website: Industrial communication http://www.siemens.com/simatic-net ● to website: CAx-Download-Manager http://www.siemens.com/cax ● to website: Industry Online Support https://support.industry.siemens.com 6EP34378SB000AY0 Page 3/4 5/24/2024 Subject to change without notice © Copyright Siemens additional information other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) security information security information Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) Classifications Version Classification 14 27-04-07-01 eClass 12 27-04-07-01 eClass 9.1 27-04-07-01 eClass 9 27-04-07-01 eClass 8 27-04-90-02 eClass 7.1 27-04-90-02 eClass 6 27-04-90-02 ETIM 9 EC002540 ETIM 8 EC002540 ETIM 7 EC002540 eClass IDEA 4 4130 UNSPSC 15 39-12-10-04 Approvals Certificates General Product Approval Manufacturer Declaration General Product Approval For use in hazardous locations BIS CRS Marine / Shipping last modified: 6EP34378SB000AY0 Page 4/4 Declaration of Conformity CCC-Ex Environment 5/22/2024 5/24/2024 Subject to change without notice © Copyright Siemens
6EP3437-8SB00-0AY0 价格&库存

很抱歉,暂时无法提供与“6EP3437-8SB00-0AY0”相匹配的价格&库存,您可以联系我们找货

免费人工找货
6EP3437-8SB00-0AY0
  •  国内价格
  • 1+4857.90919

库存:27