Data sheet
6EP3446-8SB10-0AY0
SITOP PSU8200/3AC/36VDC/13A
SITOP PSU8200 36 V/13 A
Stabilized power supply input: 3
AC 400-500 V output: 36 V
DC/13 A
Input
Input
3-phase AC
Rated voltage value Vin rated
400 ... 500 V
Voltage range AC
320 ... 575 V
Wide-range input
Yes
Mains buffering
at Vin = 400 V
Mains buffering at Iout rated, min.
15 ms; at Vin = 400 V
Rated line frequency 1
50 Hz
Rated line frequency 2
60 Hz
Rated line range
47 ... 63 Hz
input current
● at rated input voltage 400 V
1.2 A
● at rated input voltage 500 V
1A
Switch-on current limiting (+25 °C), max.
16 A
I²t, max.
0.8 A²·s
Built-in incoming fuse
none
Protection in the mains power input (IEC 898)
Required: 3-pole connected miniature circuit breaker 6 ... 16 A
characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or
3RV2711-1DD10 (UL 489)
Output
Output
Controlled, isolated DC voltage
Rated voltage Vout DC
36 V
Total tolerance, static ±
3%
Static mains compensation, approx.
0.1 %
Static load balancing, approx.
0.2 %
Residual ripple peak-peak, max.
100 mV
Spikes peak-peak, max. (bandwidth: 20 MHz)
200 mV
Adjustment range
36 ... 42 V
product function output voltage adjustable
Yes
Output voltage setting
via potentiometer; max. 480 W
Status display
Green LED for 36 V OK
Signaling
Relay contact (NO contact, rating 60 V DC/ 0.3 A) for 36 V OK
On/off behavior
No overshoot of Vout (soft start)
Startup delay, max.
2.5 s
voltage increase time of the output voltage maximum
500 ms
6EP34468SB100AY0
Page 1/2
1.16.2021
Subject to change without notice
© Copyright Siemens
Rated current value Iout rated
13 A
Current range
0 ... 13 A
● Note
supplied active power typical
+60 ... +70 °C: Derating 2%/K
468 W
short-term overload current
● at short-circuit during operation typical
39 A
duration of overloading capability for excess current
● at short-circuit during operation
25 ms
constant overload current
● on short-circuiting during the start-up typical
14 A
Parallel switching for enhanced performance
Yes; switchable characteristic
Numbers of parallel switchable units for enhanced
performance
2
Efficiency
Efficiency at Vout rated, Iout rated, approx.
94 %
Power loss at Vout rated, Iout rated, approx.
30 W
Closed-loop control
Dynamic mains compensation (Vin rated ±15 %), max.
0.1 %
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ.
1%
Load step setting time 50 to 100%, typ.
0.2 ms
Load step setting time 100 to 50%, typ.
0.2 ms
Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ.
2%
Load step setting time 10 to 90%, typ.
0.2 ms
Load step setting time 90 to 10%, typ.
0.2 ms
setting time maximum
10 ms
Protection and monitoring
Output overvoltage protection
< 48 V
Current limitation, typ.
14 A
property of the output short-circuit proof
Yes
Short-circuit protection
Alternatively, constant current characteristic approx. 14 A or latching
shutdown
enduring short circuit current RMS value
● typical
14 A
overcurrent overload capability in normal operation
overload capability 150 % Iout rated up to 5 s/min
Overload/short-circuit indicator
LED yellow for "overload", LED red for "latching shutdown"
Safety
Primary/secondary isolation
Yes
galvanic isolation
Safety extra low output voltage Vout according to EN 60950-1
Protection class
Class I
leakage current
● maximum
3.5 mA
● typical
0.9 mA
Degree of protection (EN 60529)
IP20
Approvals
CE mark
Yes
UL/cUL (CSA) approval
cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus
(CSA C22.2 No. 60950-1, UL 60950-1)
Explosion protection
IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc;
cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2,
Group ABCD, T4
certificate of suitability NEC Class 2
No
FM approval
-
CB approval
Yes
Marine approval
-
EMC
Emitted interference
EN 55022 Class B
Supply harmonics limitation
EN 61000-3-2
Noise immunity
EN 61000-6-2
6EP34468SB100AY0
Page 2/3
1.16.2021
Subject to change without notice
© Copyright Siemens
environmental conditions
ambient temperature
● during operation
— Note
-25 ... +70 °C
with natural convection
● during transport
-40 ... +85 °C
● during storage
-40 ... +85 °C
Humidity class according to EN 60721
Climate class 3K3, 5 … 95% no condensation
Mechanics
Connection technology
screw-type terminals
Connections
● Supply input
L1, L2, L3, PE: 1 screw terminal each for 0.2 ... 4 mm² single-core/finely
stranded
● Output
+, -: 2 screw terminals each for 0.2 ... 4 mm²
● Auxiliary
13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²; 15, 16
(Remote): 1 screw terminal each for 0.14 ... 1.5 mm²
width of the enclosure
70 mm
height of the enclosure
125 mm
depth of the enclosure
125 mm
required spacing
● top
50 mm
● bottom
50 mm
● left
0 mm
● right
0 mm
Weight, approx.
1.2 kg
product feature of the enclosure housing can be lined up
Yes
Installation
Snaps onto DIN rail EN 60715 35x7.5/15
mechanical accessories
Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20
other information
Specifications at rated input voltage and ambient temperature +25 °C
(unless otherwise specified)
6EP34468SB100AY0
Page 3/3
1.16.2021
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“6EP34468SB100AY0”相匹配的价格&库存,您可以联系我们找货