6EP34468SB100AY0

6EP34468SB100AY0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SITOP PSU8200 36 V/13 A

  • 数据手册
  • 价格&库存
6EP34468SB100AY0 数据手册
Data sheet 6EP3446-8SB10-0AY0 SITOP PSU8200/3AC/36VDC/13A SITOP PSU8200 36 V/13 A Stabilized power supply input: 3 AC 400-500 V output: 36 V DC/13 A Input Input 3-phase AC Rated voltage value Vin rated 400 ... 500 V Voltage range AC 320 ... 575 V Wide-range input Yes Mains buffering at Vin = 400 V Mains buffering at Iout rated, min. 15 ms; at Vin = 400 V Rated line frequency 1 50 Hz Rated line frequency 2 60 Hz Rated line range 47 ... 63 Hz input current ● at rated input voltage 400 V 1.2 A ● at rated input voltage 500 V 1A Switch-on current limiting (+25 °C), max. 16 A I²t, max. 0.8 A²·s Built-in incoming fuse none Protection in the mains power input (IEC 898) Required: 3-pole connected miniature circuit breaker 6 ... 16 A characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) Output Output Controlled, isolated DC voltage Rated voltage Vout DC 36 V Total tolerance, static ± 3% Static mains compensation, approx. 0.1 % Static load balancing, approx. 0.2 % Residual ripple peak-peak, max. 100 mV Spikes peak-peak, max. (bandwidth: 20 MHz) 200 mV Adjustment range 36 ... 42 V product function output voltage adjustable Yes Output voltage setting via potentiometer; max. 480 W Status display Green LED for 36 V OK Signaling Relay contact (NO contact, rating 60 V DC/ 0.3 A) for 36 V OK On/off behavior No overshoot of Vout (soft start) Startup delay, max. 2.5 s voltage increase time of the output voltage maximum 500 ms 6EP34468SB100AY0 Page 1/2 1.16.2021 Subject to change without notice © Copyright Siemens Rated current value Iout rated 13 A Current range 0 ... 13 A ● Note supplied active power typical +60 ... +70 °C: Derating 2%/K 468 W short-term overload current ● at short-circuit during operation typical 39 A duration of overloading capability for excess current ● at short-circuit during operation 25 ms constant overload current ● on short-circuiting during the start-up typical 14 A Parallel switching for enhanced performance Yes; switchable characteristic Numbers of parallel switchable units for enhanced performance 2 Efficiency Efficiency at Vout rated, Iout rated, approx. 94 % Power loss at Vout rated, Iout rated, approx. 30 W Closed-loop control Dynamic mains compensation (Vin rated ±15 %), max. 0.1 % Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. 1% Load step setting time 50 to 100%, typ. 0.2 ms Load step setting time 100 to 50%, typ. 0.2 ms Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ. 2% Load step setting time 10 to 90%, typ. 0.2 ms Load step setting time 90 to 10%, typ. 0.2 ms setting time maximum 10 ms Protection and monitoring Output overvoltage protection < 48 V Current limitation, typ. 14 A property of the output short-circuit proof Yes Short-circuit protection Alternatively, constant current characteristic approx. 14 A or latching shutdown enduring short circuit current RMS value ● typical 14 A overcurrent overload capability in normal operation overload capability 150 % Iout rated up to 5 s/min Overload/short-circuit indicator LED yellow for "overload", LED red for "latching shutdown" Safety Primary/secondary isolation Yes galvanic isolation Safety extra low output voltage Vout according to EN 60950-1 Protection class Class I leakage current ● maximum 3.5 mA ● typical 0.9 mA Degree of protection (EN 60529) IP20 Approvals CE mark Yes UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) Explosion protection IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T4 certificate of suitability NEC Class 2 No FM approval - CB approval Yes Marine approval - EMC Emitted interference EN 55022 Class B Supply harmonics limitation EN 61000-3-2 Noise immunity EN 61000-6-2 6EP34468SB100AY0 Page 2/3 1.16.2021 Subject to change without notice © Copyright Siemens environmental conditions ambient temperature ● during operation — Note -25 ... +70 °C with natural convection ● during transport -40 ... +85 °C ● during storage -40 ... +85 °C Humidity class according to EN 60721 Climate class 3K3, 5 … 95% no condensation Mechanics Connection technology screw-type terminals Connections ● Supply input L1, L2, L3, PE: 1 screw terminal each for 0.2 ... 4 mm² single-core/finely stranded ● Output +, -: 2 screw terminals each for 0.2 ... 4 mm² ● Auxiliary 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²; 15, 16 (Remote): 1 screw terminal each for 0.14 ... 1.5 mm² width of the enclosure 70 mm height of the enclosure 125 mm depth of the enclosure 125 mm required spacing ● top 50 mm ● bottom 50 mm ● left 0 mm ● right 0 mm Weight, approx. 1.2 kg product feature of the enclosure housing can be lined up Yes Installation Snaps onto DIN rail EN 60715 35x7.5/15 mechanical accessories Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20 other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) 6EP34468SB100AY0 Page 3/3 1.16.2021 Subject to change without notice © Copyright Siemens
6EP34468SB100AY0 价格&库存

很抱歉,暂时无法提供与“6EP34468SB100AY0”相匹配的价格&库存,您可以联系我们找货

免费人工找货