0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES7134-6GF00-0AA1

6ES7134-6GF00-0AA1

  • 厂商:

    SIEMENS(西门子)

  • 封装:

  • 描述:

    SIEMENS - 6ES7134-6GF00-0AA1 - Analog Input Module, 8 Inputs, 24 VDC

  • 数据手册
  • 价格&库存
6ES7134-6GF00-0AA1 数据手册
Data sheet 6ES7134-6GF00-0AA1 SIMATIC ET 200SP, Analog input module, AI 8XI 2-/4-wire Basic, suitable for BU type A0, A1, Color code CC01, Module diagnostics, 16 bit General information Product type designation AI 8xI 2-/4-wire BA HW functional status from FS21 Firmware version V1.0.1 ● FW update possible Yes usable BaseUnits BU type A0, A1 Color code for module-specific color identification plate CC01 Product function ● I&M data Yes; I&M0 to I&M3 ● Isochronous mode No ● Measuring range scalable No Engineering with ● STEP 7 TIA Portal configurable/integrated from version V13 SP1 ● STEP 7 configurable/integrated from version V5.5 SP3 / - ● PROFIBUS from GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher ● PROFINET from GSD version/GSD revision GSDML V2.3 Operating mode ● Oversampling No ● MSI No CiR - Configuration in RUN Reparameterization possible in RUN No Calibration possible in RUN No Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Input current Current consumption, max. 25 mA; without sensor supply Encoder supply 24 V encoder supply ● 24 V Yes ● Short-circuit protection Yes ● Output current, max. 0.7 A; total current of all encoders/channels Power loss Power loss, typ. 0.7 W; Without encoder supply voltage Address area Address space per module ● Address space per module, max. 16 byte Hardware configuration 6ES71346GF000AA1 Page 1/3 5/24/2024 Subject to change without notice © Copyright Siemens Automatic encoding Yes ● Mechanical coding element Yes ● Type of mechanical coding element Type A Selection of BaseUnit for connection variants ● 1-wire connection BU type A0, A1 ● 2-wire connection BU type A0, A1 ● 4-wire connection BU type A0, A1 + potential distributor module Analog inputs Number of analog inputs ● For current measurement 8; Single-ended 8 permissible input current for current input (destruction limit), max. 50 mA Cycle time (all channels), min. 1 ms; per channel Input ranges (rated values), currents ● 0 to 20 mA — Input resistance (0 to 20 mA) ● -20 mA to +20 mA — Input resistance (-20 mA to +20 mA) ● 4 mA to 20 mA — Input resistance (4 mA to 20 mA) Yes 100 Ω; 15 bit Yes 100 Ω; 16 bit incl. sign Yes 100 Ω; 15 bit Cable length ● shielded, max. 200 m Analog value generation for the inputs Integration and conversion time/resolution per channel ● Resolution with overrange (bit including sign), max. 16 bit ● Integration time, parameterizable Yes ● Interference voltage suppression for interference frequency f1 in Hz 16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) ● Conversion time (per channel) 180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms Smoothing of measured values ● Number of smoothing levels 4 ● parameterizable Yes ● Step: None Yes ● Step: low Yes ● Step: Medium Yes ● Step: High Yes Encoder Connection of signal encoders ● for voltage measurement No ● for current measurement as 2-wire transducer Yes — Burden of 2-wire transmitter, max. ● for current measurement as 4-wire transducer 650 Ω Yes Errors/accuracies Linearity error (relative to input range), (+/-) 0.01 % Temperature error (relative to input range), (+/-) 0.005 %/K Crosstalk between the inputs, min. 50 dB Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.05 % Operational error limit in overall temperature range ● Current, relative to input range, (+/-) 0.5 % Basic error limit (operational limit at 25 °C) ● Current, relative to input range, (+/-) 0.3 % Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency ● Series mode interference (peak value of interference < rated value of input range), min. 70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB Interrupts/diagnostics/status information Diagnostics function Yes Alarms ● Diagnostic alarm Yes ● Limit value alarm No Diagnoses ● Monitoring the supply voltage 6ES71346GF000AA1 Page 2/3 Yes 5/24/2024 Subject to change without notice © Copyright Siemens ● Wire-break Yes; at 4 to 20 mA ● Short-circuit Yes; Sensor supply to M; module by module ● Group error Yes ● Overflow/underflow Yes; Module-wise Diagnostics indication LED ● Monitoring of the supply voltage (PWR-LED) Yes; green LED ● Channel status display Yes; green LED ● for channel diagnostics No ● for module diagnostics Yes; green/red DIAG LED Potential separation Potential separation channels ● between the channels No ● between the channels and backplane bus Yes ● between the channels and the power supply of the electronics No Isolation Isolation tested with 707 V DC (type test) Ambient conditions Ambient temperature during operation ● horizontal installation, min. -30 °C; < 0 °C as of FS04 ● horizontal installation, max. 60 °C ● vertical installation, min. -30 °C; < 0 °C as of FS04 ● vertical installation, max. 50 °C Altitude during operation relating to sea level ● Installation altitude above sea level, max. 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual Dimensions Width 15 mm Height 73 mm Depth 58 mm Weights Weight, approx. 31 g last modified: 5/22/2024 6ES71346GF000AA1 Page 3/3 5/24/2024 Subject to change without notice © Copyright Siemens
6ES7134-6GF00-0AA1 价格&库存

很抱歉,暂时无法提供与“6ES7134-6GF00-0AA1”相匹配的价格&库存,您可以联系我们找货

免费人工找货
6ES7134-6GF00-0AA1
  •  国内价格 香港价格
  • 1+2587.087561+323.28170

库存:0

6ES7134-6GF00-0AA1
  •  国内价格
  • 1+2298.81288

库存:37