0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES71346JD002CA1

6ES71346JD002CA1

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    ET 200SP. AI 4XRTD/TC 2-/3-/4-WI

  • 数据手册
  • 价格&库存
6ES71346JD002CA1 数据手册
Data sheet 6ES7134-6JD00-2CA1 SIMATIC ET 200SP, Analog input module, AI 4xRTD/TC High Feature, Pack quantity: 10 units, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1%, 2-/3-/4-wire General information Product type designation AI 4xRTD/TC 2-/3-/4-wire HF HW functional status From FS08 Firmware version ● FW update possible Yes usable BaseUnits BU type A0, A1 Color code for module-specific color identification plate CC00 Product function ● I&M data Yes; I&M0 to I&M3 ● Isochronous mode No ● Adjustment of measuring range Yes Engineering with ● STEP 7 TIA Portal configurable/integrated from version V14 ● PCS 7 configurable/integrated from version V8.1 SP1 ● PROFIBUS from GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher ● PROFINET from GSD version/GSD revision GSDML V2.3 Operating mode ● Oversampling No ● MSI No CiR - Configuration in RUN Reparameterization possible in RUN Yes Calibration possible in RUN Yes Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Input current Current consumption, max. 35 mA Power loss Power loss, typ. 0.75 W Address area Address space per module ● Address space per module, max. 8 byte; + 1 byte for QI information Hardware configuration Automatic encoding 6ES71346JD002CA1 Page 1/2 Yes 1.19.2021 Subject to change without notice © Copyright Siemens ● Mechanical coding element Yes ● Type of mechanical coding element Type A Selection of BaseUnit for connection variants ● 2-wire connection BU type A0, A1 ● 3-wire connection BU type A0, A1 Analog inputs Number of analog inputs 4 permissible input voltage for voltage input (destruction limit), max. 30 V Constant measurement current for resistance-type transmitter, typ. 0.7 mA Cycle time (all channels), min. Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels); for line compensation in case of a three-wire connection, an additional cycle is necessary Technical unit for temperature measurement adjustable Yes; °C/°F/K Input ranges (rated values), voltages ● -1 V to +1 V — Input resistance (-1 V to +1 V) ● -250 mV to +250 mV — Input resistance (-250 mV to +250 mV) ● -50 mV to +50 mV — Input resistance (-50 mV to +50 mV) ● -80 mV to +80 mV — Input resistance (-80 mV to +80 mV) Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Input ranges (rated values), thermocouples ● Type B — Input resistance (Type B) ● Type C — Input resistance (Type C) ● Type E — Input resistance (Type E) ● Type J — Input resistance (type J) ● Type K — Input resistance (Type K) ● Type L — Input resistance (Type L) ● Type N — Input resistance (Type N) ● Type R — Input resistance (Type R) ● Type S — Input resistance (Type S) ● Type T — Input resistance (Type T) ● Type U — Input resistance (Type U) ● Type TXK/TXK(L) to GOST — Input resistance (Type TXK/TXK(L) to GOST) Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Input ranges (rated values), resistance thermometer ● Cu 10 — Input resistance (Cu 10) ● Ni 100 — Input resistance (Ni 100) ● Ni 1000 — Input resistance (Ni 1000) ● LG-Ni 1000 — Input resistance (LG-Ni 1000) 6ES71346JD002CA1 Page 2/3 Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ 1.19.2021 Subject to change without notice © Copyright Siemens ● Ni 120 — Input resistance (Ni 120) ● Ni 200 — Input resistance (Ni 200) ● Ni 500 — Input resistance (Ni 500) ● Pt 100 — Input resistance (Pt 100) ● Pt 1000 — Input resistance (Pt 1000) ● Pt 200 — Input resistance (Pt 200) ● Pt 500 — Input resistance (Pt 500) Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Yes; 16 bit incl. sign 1 MΩ Input ranges (rated values), resistors ● 0 to 150 ohms — Input resistance (0 to 150 ohms) ● 0 to 300 ohms — Input resistance (0 to 300 ohms) ● 0 to 600 ohms — Input resistance (0 to 600 ohms) ● 0 to 3000 ohms — Input resistance (0 to 3000 ohms) ● 0 to 6000 ohms — Input resistance (0 to 6000 ohms) ● PTC — Input resistance (PTC) Yes; 15 bit 1 MΩ Yes; 15 bit 1 MΩ Yes; 15 bit 1 MΩ Yes; 15 bit 1 MΩ Yes; 15 bit 1 MΩ Yes 1 MΩ Thermocouple (TC) Temperature compensation — parameterizable Yes — Reference channel of the module Yes — internal comparison point Yes; with BaseUnit type A1 — Reference channel of the group Yes — Number of reference channel groups 4; Group 0 to 3 — fixed reference temperature Yes Cable length ● shielded, max. 200 m; 50 m with thermocouples Analog value generation for the inputs Measurement principle integrating (Sigma-Delta) Integration and conversion time/resolution per channel ● Resolution with overrange (bit including sign), max. 16 bit ● Integration time, parameterizable Yes ● Basic conversion time, including integration time (ms) — additional processing time for wire-break check 2 ms; In the ranges resistance thermometers, resistors and thermocouples — additional power line wire-break check 2 ms; for 3/4 wire transducer (resistance thermometer and resistor) ● Interference voltage suppression for interference frequency f1 in Hz 16.6 / 50 / 60 Hz ● Conversion time (per channel) 180 / 60 / 50 ms Smoothing of measured values ● Number of smoothing levels 4; None; 4/8/16 times ● parameterizable Yes Encoder Connection of signal encoders ● for voltage measurement Yes ● for resistance measurement with two-wire connection Yes ● for resistance measurement with three-wire Yes 6ES71346JD002CA1 Page 3/4 1.19.2021 Subject to change without notice © Copyright Siemens connection ● for resistance measurement with four-wire connection Yes Errors/accuracies Linearity error (relative to input range), (+/-) 0.01 %; ±0.1 % for resistance thermometers and resistance Temperature error (relative to input range), (+/-) 0.0009 %/K; ±0.005 % / K at thermocouple Crosstalk between the inputs, min. -50 dB Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.05 % Operational error limit in overall temperature range ● Voltage, relative to input range, (+/-) 0.1 % ● Resistance, relative to input range, (+/-) 0.1 % Basic error limit (operational limit at 25 °C) ● Voltage, relative to input range, (+/-) 0.05 % ● Resistance, relative to input range, (+/-) 0.05 % Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency ● Series mode interference (peak value of interference < rated value of input range), min. 70 dB ● Common mode voltage, max. 10 V ● Common mode interference, min. 90 dB Interrupts/diagnostics/status information Diagnostics function Yes Alarms ● Diagnostic alarm Yes ● Limit value alarm Yes; two upper and two lower limit values in each case Diagnoses ● Monitoring the supply voltage Yes ● Wire-break Yes; channel by channel ● Group error Yes ● Overflow/underflow Yes; channel by channel Diagnostics indication LED ● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED ● Channel status display Yes; green LED ● for channel diagnostics Yes; red LED ● for module diagnostics Yes; green/red DIAG LED Potential separation Potential separation channels ● between the channels No ● between the channels and backplane bus Yes ● between the channels and the power supply of the electronics Yes Permissible potential difference between the inputs (UCM) 10 V DC Isolation Isolation tested with 707 V DC (type test) Ambient conditions Ambient temperature during operation ● horizontal installation, min. -30 °C; < 0 °C as of FS08 ● horizontal installation, max. 60 °C ● vertical installation, min. -30 °C; < 0 °C as of FS08 ● vertical installation, max. 50 °C Altitude during operation relating to sea level ● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual Dimensions Width 15 mm Height 73 mm Depth 58 mm last modified: 1/16/2021 6ES71346JD002CA1 Page 4/5 1.19.2021 Subject to change without notice © Copyright Siemens 6ES71346JD002CA1 Page 5/5 1.19.2021 Subject to change without notice © Copyright Siemens
6ES71346JD002CA1 价格&库存

很抱歉,暂时无法提供与“6ES71346JD002CA1”相匹配的价格&库存,您可以联系我们找货

免费人工找货