Data sheet
6ES7134-6JD00-2CA1
SIMATIC ET 200SP, Analog input module, AI 4xRTD/TC High Feature,
Pack quantity: 10 units, suitable for BU type A0, A1, Color code CC00,
channel diagnostics, 16 bit, +/-0.1%, 2-/3-/4-wire
General information
Product type designation
AI 4xRTD/TC 2-/3-/4-wire HF
HW functional status
From FS08
Firmware version
● FW update possible
Yes
usable BaseUnits
BU type A0, A1
Color code for module-specific color identification plate
CC00
Product function
● I&M data
Yes; I&M0 to I&M3
● Isochronous mode
No
● Adjustment of measuring range
Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from
version
V14
● PCS 7 configurable/integrated from version
V8.1 SP1
● PROFIBUS from GSD version/GSD revision
One GSD file each, Revision 3 and 5 and higher
● PROFINET from GSD version/GSD revision
GSDML V2.3
Operating mode
● Oversampling
No
● MSI
No
CiR - Configuration in RUN
Reparameterization possible in RUN
Yes
Calibration possible in RUN
Yes
Supply voltage
Rated value (DC)
24 V
permissible range, lower limit (DC)
19.2 V
permissible range, upper limit (DC)
28.8 V
Reverse polarity protection
Yes
Input current
Current consumption, max.
35 mA
Power loss
Power loss, typ.
0.75 W
Address area
Address space per module
● Address space per module, max.
8 byte; + 1 byte for QI information
Hardware configuration
Automatic encoding
6ES71346JD002CA1
Page 1/2
Yes
1.19.2021
Subject to change without notice
© Copyright Siemens
● Mechanical coding element
Yes
● Type of mechanical coding element
Type A
Selection of BaseUnit for connection variants
● 2-wire connection
BU type A0, A1
● 3-wire connection
BU type A0, A1
Analog inputs
Number of analog inputs
4
permissible input voltage for voltage input (destruction
limit), max.
30 V
Constant measurement current for resistance-type
transmitter, typ.
0.7 mA
Cycle time (all channels), min.
Sum of the basic conversion times and additional processing times
(depending on the parameterization of the active channels); for line
compensation in case of a three-wire connection, an additional cycle is
necessary
Technical unit for temperature measurement adjustable
Yes; °C/°F/K
Input ranges (rated values), voltages
● -1 V to +1 V
— Input resistance (-1 V to +1 V)
● -250 mV to +250 mV
— Input resistance (-250 mV to +250 mV)
● -50 mV to +50 mV
— Input resistance (-50 mV to +50 mV)
● -80 mV to +80 mV
— Input resistance (-80 mV to +80 mV)
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Input ranges (rated values), thermocouples
● Type B
— Input resistance (Type B)
● Type C
— Input resistance (Type C)
● Type E
— Input resistance (Type E)
● Type J
— Input resistance (type J)
● Type K
— Input resistance (Type K)
● Type L
— Input resistance (Type L)
● Type N
— Input resistance (Type N)
● Type R
— Input resistance (Type R)
● Type S
— Input resistance (Type S)
● Type T
— Input resistance (Type T)
● Type U
— Input resistance (Type U)
● Type TXK/TXK(L) to GOST
— Input resistance (Type TXK/TXK(L) to GOST)
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Input ranges (rated values), resistance thermometer
● Cu 10
— Input resistance (Cu 10)
● Ni 100
— Input resistance (Ni 100)
● Ni 1000
— Input resistance (Ni 1000)
● LG-Ni 1000
— Input resistance (LG-Ni 1000)
6ES71346JD002CA1
Page 2/3
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
1.19.2021
Subject to change without notice
© Copyright Siemens
● Ni 120
— Input resistance (Ni 120)
● Ni 200
— Input resistance (Ni 200)
● Ni 500
— Input resistance (Ni 500)
● Pt 100
— Input resistance (Pt 100)
● Pt 1000
— Input resistance (Pt 1000)
● Pt 200
— Input resistance (Pt 200)
● Pt 500
— Input resistance (Pt 500)
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Yes; 16 bit incl. sign
1 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohms
— Input resistance (0 to 150 ohms)
● 0 to 300 ohms
— Input resistance (0 to 300 ohms)
● 0 to 600 ohms
— Input resistance (0 to 600 ohms)
● 0 to 3000 ohms
— Input resistance (0 to 3000 ohms)
● 0 to 6000 ohms
— Input resistance (0 to 6000 ohms)
● PTC
— Input resistance (PTC)
Yes; 15 bit
1 MΩ
Yes; 15 bit
1 MΩ
Yes; 15 bit
1 MΩ
Yes; 15 bit
1 MΩ
Yes; 15 bit
1 MΩ
Yes
1 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizable
Yes
— Reference channel of the module
Yes
— internal comparison point
Yes; with BaseUnit type A1
— Reference channel of the group
Yes
— Number of reference channel groups
4; Group 0 to 3
— fixed reference temperature
Yes
Cable length
● shielded, max.
200 m; 50 m with thermocouples
Analog value generation for the inputs
Measurement principle
integrating (Sigma-Delta)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
16 bit
● Integration time, parameterizable
Yes
● Basic conversion time, including integration time
(ms)
— additional processing time for wire-break check
2 ms; In the ranges resistance thermometers, resistors and
thermocouples
— additional power line wire-break check
2 ms; for 3/4 wire transducer (resistance thermometer and resistor)
● Interference voltage suppression for interference
frequency f1 in Hz
16.6 / 50 / 60 Hz
● Conversion time (per channel)
180 / 60 / 50 ms
Smoothing of measured values
● Number of smoothing levels
4; None; 4/8/16 times
● parameterizable
Yes
Encoder
Connection of signal encoders
● for voltage measurement
Yes
● for resistance measurement with two-wire
connection
Yes
● for resistance measurement with three-wire
Yes
6ES71346JD002CA1
Page 3/4
1.19.2021
Subject to change without notice
© Copyright Siemens
connection
● for resistance measurement with four-wire
connection
Yes
Errors/accuracies
Linearity error (relative to input range), (+/-)
0.01 %; ±0.1 % for resistance thermometers and resistance
Temperature error (relative to input range), (+/-)
0.0009 %/K; ±0.005 % / K at thermocouple
Crosstalk between the inputs, min.
-50 dB
Repeat accuracy in steady state at 25 °C (relative to input
range), (+/-)
0.05 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)
0.1 %
● Resistance, relative to input range, (+/-)
0.1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)
0.05 %
● Resistance, relative to input range, (+/-)
0.05 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of
interference < rated value of input range), min.
70 dB
● Common mode voltage, max.
10 V
● Common mode interference, min.
90 dB
Interrupts/diagnostics/status information
Diagnostics function
Yes
Alarms
● Diagnostic alarm
Yes
● Limit value alarm
Yes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltage
Yes
● Wire-break
Yes; channel by channel
● Group error
Yes
● Overflow/underflow
Yes; channel by channel
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)
Yes; green PWR LED
● Channel status display
Yes; green LED
● for channel diagnostics
Yes; red LED
● for module diagnostics
Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels
No
● between the channels and backplane bus
Yes
● between the channels and the power supply of the
electronics
Yes
Permissible potential difference
between the inputs (UCM)
10 V DC
Isolation
Isolation tested with
707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
-30 °C; < 0 °C as of FS08
● horizontal installation, max.
60 °C
● vertical installation, min.
-30 °C; < 0 °C as of FS08
● vertical installation, max.
50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width
15 mm
Height
73 mm
Depth
58 mm