0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES7136-6AA00-0CA1.

6ES7136-6AA00-0CA1.

  • 厂商:

    SIEMENS(西门子)

  • 封装:

  • 描述:

    SIEMENS - 6ES7136-6AA00-0CA1. - Electronic Module, 4 I/P, 24 VDC, SIMATIC DP Series

  • 数据手册
  • 价格&库存
6ES7136-6AA00-0CA1. 数据手册
Data sheet 6ES7136-6AA00-0CA1 SIMATIC DP, electronic module ET 200SP, F-AI 4xI0(4)..20 mA HF fail-safe analog inputs up to PL e (ISO 13849) up to SIL 3 (IEC 61508) General information Product type designation F-AI 4xI 0(4)..20mA 2-/4-wire HF Firmware version ● FW update possible Yes usable BaseUnits BU type A0, A1 Color code for module-specific color identification plate CC00 Product function ● I&M data Yes; I&M0 to I&M3 Engineering with ● STEP 7 TIA Portal configurable/integrated from version V15 with HSP 203 CiR - Configuration in RUN Reparameterization possible in RUN No Calibration possible in RUN No Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes power supply according to NEC Class 2 required No Input current Current consumption (rated value) 0.38 A Current consumption, max. 0.4 A Encoder supply 24 V encoder supply ● 24 V Yes; min. L+ (-1.5 V) ● Short-circuit protection Yes ● Output current, max. 300 mA; total current of all encoders/channels Power Power available from the backplane bus 70 mW Power loss Power loss, typ. 2W Address area Address space per module ● Inputs 14 byte; S7-300/400F CPU, 13 byte ● Outputs 5 byte; S7-300/400F CPU, 4 byte Hardware configuration Automatic encoding ● Electronic coding element type F Yes Yes Analog inputs Number of analog inputs 6ES71366AA000CA1 Page 1/3 4 5/15/2024 Subject to change without notice © Copyright Siemens ● For current measurement permissible input current for current input (destruction limit), max. 4 35 mA Input ranges (rated values), currents ● 0 to 20 mA — Input resistance (0 to 20 mA) ● 4 mA to 20 mA — Input resistance (4 mA to 20 mA) Yes 125 Ω Yes 125 Ω Cable length ● shielded, max. 1 000 m Analog value generation for the inputs Measurement principle Sigma Delta Integration and conversion time/resolution per channel ● Resolution with overrange (bit including sign), max. 16 bit ● Integration time, parameterizable Yes ● Integration time (ms) 20 / 16,667 ● Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz Smoothing of measured values ● Number of smoothing levels 7 ● parameterizable Yes ● Step: None Yes; 1x conversion cycle time ● Step: low Yes; 2x / 4x conversion cycle time ● Step: Medium Yes; 8x / 16x conversion cycle time ● Step: High Yes; 32x / 64x conversion cycle time Encoder Connection of signal encoders ● for current measurement as 2-wire transducer — Burden of 2-wire transmitter, max. ● for current measurement as 4-wire transducer Yes 650 Ω Yes Errors/accuracies Linearity error (relative to input range), (+/-) 0.1 % Temperature error (relative to input range), (+/-) 0.023 %/K Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.1 % Operational error limit in overall temperature range ● Current, relative to input range, (+/-) 2% Basic error limit (operational limit at 25 °C) ● Current, relative to input range, (+/-) 0.1 % Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency ● Series mode interference (peak value of interference < rated value of input range), min. 40 dB ● Common mode interference, min. 70 dB Interrupts/diagnostics/status information Diagnostics function Yes Alarms ● Diagnostic alarm Yes ● Limit value alarm No Diagnoses ● Monitoring the supply voltage Yes ● Wire-break Yes ● Short-circuit Yes Diagnostics indication LED ● RUN LED Yes; green LED ● ERROR LED Yes; red LED ● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED ● Channel status display Yes; green LED ● for channel diagnostics Yes; red LED ● for module diagnostics Yes; green/red DIAG LED Potential separation Potential separation channels ● between the channels 6ES71366AA000CA1 Page 2/3 No 5/15/2024 Subject to change without notice © Copyright Siemens ● between the channels and backplane bus Yes ● between the channels and the power supply of the electronics Yes Permissible potential difference between the inputs (UCM) 10 Vpp Isolation Isolation tested with 707 V DC (type test) Standards, approvals, certificates Highest safety class achievable in safety mode ● Performance level according to ISO 13849-1 PLe ● Category according to ISO 13849-1 Cat. 4 ● SIL acc. to IEC 61508 SIL 3 Probability of failure (for service life of 20 years and repair time of 100 hours) — Low demand mode: PFDavg in accordance with SIL3 < 5.00E-05 — High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09 1/h Ambient conditions Ambient temperature during operation ● horizontal installation, min. 0 °C ● horizontal installation, max. 60 °C ● vertical installation, min. 0 °C ● vertical installation, max. 50 °C Dimensions Width 15 mm Height 73 mm Depth 58 mm Weights Weight, approx. 48 g last modified: 4/25/2024 6ES71366AA000CA1 Page 3/3 5/15/2024 Subject to change without notice © Copyright Siemens
6ES7136-6AA00-0CA1. 价格&库存

很抱歉,暂时无法提供与“6ES7136-6AA00-0CA1.”相匹配的价格&库存,您可以联系我们找货

免费人工找货