Data sheet
6ES7314-6CH04-0AB0
SIMATIC S7-300, CPU 314C-2 DP Compact CPU with MPI, 24 DI/16 DO, 4 AI, 2
AO, 1 Pt100, 4 high-speed counters (60 kHz), integrated DP interface, Integr.
power supply 24 V DC, work memory 192 KB, Front connector (2x 40-pole) and
Micro Memory Card required
General information
HW functional status
01
Firmware version
V3.3
Engineering with
● Programming package
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
Supply voltage
Rated value (DC)
24 V
permissible range, lower limit (DC)
19.2 V
permissible range, upper limit (DC)
28.8 V
external protection for power supply lines (recommendation)
Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min.
4A
Mains buffering
● Mains/voltage failure stored energy time
5 ms
● Repeat rate, min.
1s
Load voltage L+
Digital inputs
— load voltage / at digital input / at DC / rated value
24 V
— Reverse polarity protection
Yes
Digital outputs
— Rated value (DC)
24 V
— Reverse polarity protection
No
Input current
Current consumption (rated value)
880 mA
Current consumption (in no-load operation), typ.
150 mA
Inrush current, typ.
5A
I²t
0.7 A²·s
Digital inputs
● from load voltage L+ (without load), max.
80 mA
Digital outputs
● from load voltage L+, max.
50 mA
Power loss
Power loss, typ.
13 W
Memory
Work memory
● integrated
192 kbyte
● expandable
No
Load memory
● Plug-in (MMC)
Yes
● Plug-in (MMC), max.
8 Mbyte
● Data management on MMC (after last programming),
min.
10 a
6ES73146CH040AB0
Page 1/11
5/6/2024
Subject to change without notice
© Copyright Siemens
Backup
● present
Yes; Guaranteed by MMC (maintenance-free)
● without battery
Yes; Program and data
CPU processing times
for bit operations, typ.
0.06 µs
for word operations, typ.
0.12 µs
for fixed point arithmetic, typ.
0.16 µs
for floating point arithmetic, typ.
0.59 µs
CPU-blocks
Number of blocks (total)
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be
reduced by the MMC used.
DB
● Number, max.
1 024; Number range: 1 to 16000
● Size, max.
64 kbyte
● Number, max.
1 024; Number range: 0 to 7999
● Size, max.
64 kbyte
● Number, max.
1 024; Number range: 0 to 7999
● Size, max.
64 kbyte
● Number, max.
see instruction list
● Size, max.
64 kbyte
● Number of free cycle OBs
1; OB 1
● Number of time alarm OBs
1; OB 10
● Number of delay alarm OBs
2; OB 20, 21
● Number of cyclic interrupt OBs
4; OB 32, 33, 34, 35
● Number of process alarm OBs
1; OB 40
● Number of DPV1 alarm OBs
3; OB 55, 56, 57
● Number of startup OBs
1; OB 100
● Number of asynchronous error OBs
5; OB 80, 82, 85, 86, 87
● Number of synchronous error OBs
2; OB 121, 122
FB
FC
OB
Nesting depth
● per priority class
16
● additional within an error OB
4
Counters, timers and their retentivity
S7 counter
● Number
256
Retentivity
— adjustable
Yes
— preset
Z 0 to Z 7
Counting range
— counting range / of S7 counters / initial value
0
— counting range / of S7 counters / full-scale value
999
IEC counter
● present
Yes
● Type
SFB
● Number
Unlimited (limited only by RAM capacity)
S7 times
● Number
256
Retentivity
— adjustable
Yes
— preset
No retentivity
Time range
— time range / of the S7 timers / initial value
10 ms
— time range / of the S7 timers / full-scale value
9 990 s
IEC timer
● present
Yes
● Type
SFB
● Number
Unlimited (limited only by RAM capacity)
Data areas and their retentivity
6ES73146CH040AB0
Page 2/11
5/6/2024
Subject to change without notice
© Copyright Siemens
Retentive data area (incl. timers, counters, flags), max.
64 kbyte
Flag
● Size, max.
256 byte
● Retentivity available
Yes; MB 0 to MB 255
● Retentivity preset
MB 0 to MB 15
● Number of clock memories
8; 1 memory byte
Data blocks
● Retentivity adjustable
Yes; via non-retain property on DB
● Retentivity preset
Yes
Local data
● per priority class, max.
32 kbyte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs
2 048 byte
● Outputs
2 048 byte
of which distributed
— Inputs
2 003 byte
— Outputs
2 010 byte
Process image
● Inputs
2 048 byte
● Outputs
2 048 byte
● Inputs, adjustable
2 048 byte
● Outputs, adjustable
2 048 byte
● Inputs, default
128 byte
● Outputs, default
128 byte
Default addresses of the integrated channels
— Digital inputs
124.0 to 126.7
— Digital outputs
124.0 to 125.7
— Analog inputs
752 to 761
— Analog outputs
752 to 755
Digital channels
● Inputs
— of which central
● Outputs
— of which central
16 048
1 016
16 096
1 008
Analog channels
● Inputs
— of which central
● Outputs
— of which central
1 006
253
1 007
250
Hardware configuration
Number of expansion units, max.
3
Number of DP masters
● integrated
1
● via CP
4
Number of operable FMs and CPs (recommended)
● FM
8
● CP, PtP
8
● CP, LAN
10
Rack
● Racks, max.
4
● Modules per rack, max.
8; In rack 3 max. 7
Time of day
Clock
● Hardware clock (real-time)
Yes
● retentive and synchronizable
Yes
● Backup time
6 wk; At 40 °C ambient temperature
● Deviation per day, max.
10 s; Typ.: 2 s
● Behavior of the clock following POWER-ON
Clock continues running after POWER OFF
● Behavior of the clock following expiry of backup period
the clock continues at the time of day it had when power was switched off
6ES73146CH040AB0
Page 3/11
5/6/2024
Subject to change without notice
© Copyright Siemens
Operating hours counter
● Number
1
● Number/Number range
0
● Range of values
0 to 2^31 hours (when using SFC 101)
● Granularity
1h
● retentive
Yes; Must be restarted at each restart
Clock synchronization
● supported
Yes
● to MPI, master
Yes
● to MPI, slave
Yes
● to DP, master
Yes; With DP slave only slave clock
● to DP, slave
Yes
● in AS, master
Yes
● in AS, slave
No
Digital inputs
Number of digital inputs
● of which inputs usable for technological functions
24
16
integrated channels (DI)
24
Input characteristic curve in accordance with IEC 61131, type 1
Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max.
24
— up to 60 °C, max.
12
vertical installation
— up to 40 °C, max.
12
Input voltage
● Rated value (DC)
24 V
● for signal "0"
-3 to +5V
● for signal "1"
+15 to +30 V
Input current
● for signal "1", typ.
8 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable
Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard
inputs during program runtime. Please note that under certain circumstances
your newly set filter time may not be effective until the next filter cycle.)
— Rated value
3 ms
for technological functions
— at "0" to "1", max.
8 µs; Minimum pulse width/minimum pause between pulses at maximum
counting frequency
Cable length
● shielded, max.
1 000 m; 50 m for technological functions
● unshielded, max.
600 m; for technological functions: No
for technological functions
— shielded, max.
50 m; at maximum count frequency
— unshielded, max.
not allowed
Digital outputs
Number of digital outputs
● of which high-speed outputs
16
4; Notice: You cannot connect the fast outputs of your CPU in parallel
integrated channels (DO)
16
Short-circuit protection
Yes; Clocked electronically
● Response threshold, typ.
1A
Limitation of inductive shutdown voltage to
L+ (-48 V)
Controlling a digital input
Yes
Switching capacity of the outputs
● on lamp load, max.
5W
Load resistance range
● lower limit
48 Ω
● upper limit
4 kΩ
Output voltage
● for signal "1", min.
6ES73146CH040AB0
Page 4/11
L+ (-0.8 V)
5/6/2024
Subject to change without notice
© Copyright Siemens
Output current
● for signal "1" rated value
500 mA
● for signal "1" permissible range, min.
5 mA
● for signal "1" permissible range, max.
0.6 A
● for signal "1" minimum load current
5 mA
● for signal "0" residual current, max.
0.5 mA
Parallel switching of two outputs
● for uprating
No
● for redundant control of a load
Yes
Switching frequency
● with resistive load, max.
100 Hz
● with inductive load, max.
0.5 Hz
● on lamp load, max.
100 Hz
● of the pulse outputs, with resistive load, max.
2.5 kHz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.
3A
— up to 60 °C, max.
2A
vertical installation
— up to 40 °C, max.
2A
Cable length
● shielded, max.
1 000 m
● unshielded, max.
600 m
Analog inputs
Number of analog inputs
5
● For voltage/current measurement
4
● For resistance/resistance thermometer measurement
1
integrated channels (AI)
5; 4x current/voltage, 1x resistance
permissible input voltage for current input (destruction limit),
max.
5 V; Permanent
permissible input voltage for voltage input (destruction limit),
max.
30 V; Permanent
permissible input current for voltage input (destruction limit),
max.
0.5 mA; Permanent
permissible input current for current input (destruction limit),
max.
50 mA; Permanent
Electrical input frequency, max.
400 Hz
No-load voltage for resistance-type transmitter, typ.
3.3 V
Constant measurement current for resistance-type transmitter,
typ.
1.25 mA
Technical unit for temperature measurement adjustable
Yes; Degrees Celsius / degrees Fahrenheit / Kelvin
Input ranges
● Voltage
Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
● Current
Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
● Resistance thermometer
Yes; Pt 100 / 10 MΩ
● Resistance
Yes; 0 Ω to 600 Ω / 10 MΩ
Input ranges (rated values), voltages
● 0 to +10 V
— Input resistance (0 to 10 V)
Yes
100 kΩ
Input ranges (rated values), currents
● 0 to 20 mA
— Input resistance (0 to 20 mA)
● -20 mA to +20 mA
— Input resistance (-20 mA to +20 mA)
● 4 mA to 20 mA
— Input resistance (4 mA to 20 mA)
Yes
100 Ω
Yes
100 Ω
Yes
100 Ω
Input ranges (rated values), resistance thermometer
● Pt 100
— Input resistance (Pt 100)
Yes
10 MΩ
Input ranges (rated values), resistors
● 0 to 600 ohms
— Input resistance (0 to 600 ohms)
6ES73146CH040AB0
Page 5/11
Yes
10 MΩ
5/6/2024
Subject to change without notice
© Copyright Siemens
Thermocouple (TC)
Temperature compensation
— parameterizable
No
Characteristic linearization
● parameterizable
— for resistance thermometer
Yes; by software
Pt 100
Cable length
● shielded, max.
100 m
Analog outputs
Number of analog outputs
2
integrated channels (AO)
2
Voltage output, short-circuit protection
Yes
Voltage output, short-circuit current, max.
55 mA
Current output, no-load voltage, max.
14 V
Output ranges, voltage
● 0 to 10 V
Yes
● -10 V to +10 V
Yes
Output ranges, current
● 0 to 20 mA
Yes
● -20 mA to +20 mA
Yes
● 4 mA to 20 mA
Yes
Connection of actuators
● for voltage output two-wire connection
Yes; Without compensation of the line resistances
● for voltage output four-wire connection
No
● for current output two-wire connection
Yes
Load impedance (in rated range of output)
● with voltage outputs, min.
1 kΩ
● with voltage outputs, capacitive load, max.
0.1 µF
● with current outputs, max.
300 Ω
● with current outputs, inductive load, max.
0.1 mH
Destruction limits against externally applied voltages and currents
● Voltages at the outputs towards MANA
16 V; Permanent
● Current, max.
50 mA; Permanent
Cable length
● shielded, max.
200 m
Analog value generation for the inputs
Measurement principle
Actual value encryption (successive approximation)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
12 bit
● Integration time, parameterizable
Yes; 16.6 / 20 ms
● Interference voltage suppression for interference
frequency f1 in Hz
50 / 60 Hz
● Time constant of the input filter
0.38 ms
● Basic execution time of the module (all channels
released)
1 ms
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
12 bit
● Conversion time (per channel)
1 ms
Settling time
● for resistive load
0.6 ms
● for capacitive load
1 ms
● for inductive load
0.5 ms
Encoder
Connection of signal encoders
● for voltage measurement
Yes
● for current measurement as 2-wire transducer
Yes; with external supply
● for current measurement as 4-wire transducer
Yes
● for resistance measurement with two-wire connection
Yes; Without compensation of the line resistances
● for resistance measurement with three-wire connection
No
● for resistance measurement with four-wire connection
No
6ES73146CH040AB0
Page 6/11
5/6/2024
Subject to change without notice
© Copyright Siemens
Connectable encoders
● 2-wire sensor
— permissible quiescent current (2-wire sensor), max.
Yes
1.5 mA
Errors/accuracies
Temperature error (relative to input range), (+/-)
0.006 %/K
Crosstalk between the inputs, min.
60 dB
Repeat accuracy in steady state at 25 °C (relative to input
range), (+/-)
0.06 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz),
(+/-)
0.1 %
Linearity error (relative to output range), (+/-)
0.15 %
Temperature error (relative to output range), (+/-)
0.01 %/K
Crosstalk between the outputs, min.
60 dB
Repeat accuracy in steady state at 25 °C (relative to output
range), (+/-)
0.06 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)
1%
● Current, relative to input range, (+/-)
1%
● Resistance, relative to input range, (+/-)
1%
● Voltage, relative to output range, (+/-)
1%
● Current, relative to output range, (+/-)
1%
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)
0.8 %; Linearity error ±0.06 %
● Current, relative to input range, (+/-)
0.8 %; Linearity error ±0.06 %
● Resistance, relative to input range, (+/-)
0.8 %; Linearity error ±0.2 %
● Resistance thermometer, relative to input range, (+/-)
0.8 %
● Voltage, relative to output range, (+/-)
0.8 %
● Current, relative to output range, (+/-)
0.8 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference <
rated value of input range), min.
30 dB
● Common mode interference, min.
40 dB
Interfaces
Number of industrial Ethernet interfaces
0
Number of PROFINET interfaces
0
Number of RS 485 interfaces
2; MPI and PROFIBUS DP
Number of RS 422 interfaces
0
1. Interface
Interface type
Integrated RS 485 interface
Isolated
No
Interface types
● RS 485
Yes
● Output current of the interface, max.
200 mA
Protocols
● MPI
Yes
● PROFIBUS DP master
No
● PROFIBUS DP slave
No
● Point-to-point connection
No
● Transmission rate, max.
187.5 kbit/s
MPI
Services
— PG/OP communication
Yes
— Routing
Yes
— Global data communication
Yes
— S7 basic communication
Yes
— S7 communication
Yes; Only server, configured on one side
— S7 communication, as client
No; but via CP and loadable FB
— S7 communication, as server
Yes
2. Interface
Interface type
Integrated RS 485 interface
Isolated
Yes
Interface types
6ES73146CH040AB0
Page 7/11
5/6/2024
Subject to change without notice
© Copyright Siemens
● RS 485
Yes
● Output current of the interface, max.
200 mA
Protocols
● MPI
No
● PROFINET IO Controller
No
● PROFINET IO Device
No
● PROFINET CBA
No
● PROFIBUS DP master
Yes
● PROFIBUS DP slave
Yes
● Point-to-point connection
No
PROFIBUS DP master
● Transmission rate, max.
12 Mbit/s
● Number of DP slaves, max.
124
Services
— PG/OP communication
Yes
— Routing
Yes
— Global data communication
No
— S7 basic communication
Yes; I blocks only
— S7 communication
Yes; Only server, configured on one side
— S7 communication, as client
No
— S7 communication, as server
Yes
— Equidistance
Yes
— Isochronous mode
No
— SYNC/FREEZE
Yes
— Activation/deactivation of DP slaves
Yes
— Number of DP slaves that can be simultaneously
activated/deactivated, max.
8
— Direct data exchange (slave-to-slave
communication)
Yes; as subscriber
— DPV1
Yes
Address area
— Inputs, max.
2 kbyte
— Outputs, max.
2 kbyte
User data per DP slave
— Inputs, max.
244 byte
— Outputs, max.
244 byte
PROFIBUS DP slave
● GSD file
The latest GSD file is available on the Internet
(http://www.siemens.com/profibus-gsd)
● Transmission rate, max.
12 Mbit/s
● automatic baud rate search
Yes; only with passive interface
● Address area, max.
32
● User data per address area, max.
32 byte
Services
— PG/OP communication
Yes
— Routing
Yes; Only with active interface
— Global data communication
No
— S7 basic communication
No
— S7 communication
Yes; Only server, configured on one side
— S7 communication, as client
No
— S7 communication, as server
Yes
— Direct data exchange (slave-to-slave
communication)
Yes
— DPV1
No
Transfer memory
— Inputs
244 byte
— Outputs
244 byte
Protocols
PROFIsafe
No
communication functions / header
PG/OP communication
Yes
Data record routing
Yes
6ES73146CH040AB0
Page 8/11
5/6/2024
Subject to change without notice
© Copyright Siemens
Global data communication
● supported
Yes
● Number of GD loops, max.
8
● Number of GD packets, max.
8
● Number of GD packets, transmitter, max.
8
● Number of GD packets, receiver, max.
8
● Size of GD packets, max.
22 byte
● Size of GD packet (of which consistent), max.
22 byte
S7 basic communication
● communication function / S7 basic communication
Yes
● User data per job, max.
76 byte
● User data per job (of which consistent), max.
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET
as server)
S7 communication
● supported
Yes
● as server
Yes
● as client
Yes; Via CP and loadable FB
● User data per job, max.
180 kbyte; With PUT/GET
● User data per job (of which consistent), max.
240 byte; as server
S5 compatible communication
● supported
Yes; via CP and loadable FC
Number of connections
● overall
12
● usable for PG communication
11
— reserved for PG communication
1
— adjustable for PG communication, min.
1
— adjustable for PG communication, max.
11
● usable for OP communication
11
— reserved for OP communication
1
— adjustable for OP communication, min.
1
— adjustable for OP communication, max.
11
● usable for S7 basic communication
8
— reserved for S7 basic communication
0
— adjustable for S7 basic communication, min.
0
— adjustable for S7 basic communication, max.
8
● usable for routing
4; max.
S7 message functions
Number of login stations for message functions, max.
12; Depending on the configured connections for PG/OP and S7 basic
communication
Process diagnostic messages
Yes
simultaneously active Alarm-S blocks, max.
300
Test commissioning functions
Status block
Yes; Up to 2 simultaneously
Single step
Yes
Number of breakpoints
4
Status/control
● Status/control variable
Yes
● Variables
Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max.
30
— of which status variables, max.
30
— of which control variables, max.
14
Forcing
● Forcing
Yes
● Forcing, variables
Inputs, outputs
● Number of variables, max.
10
Diagnostic buffer
● present
Yes
● Number of entries, max.
500
— adjustable
No
— of which powerfail-proof
100; Only the last 100 entries are retained
● Number of entries readable in RUN, max.
6ES73146CH040AB0
Page 9/11
499
5/6/2024
Subject to change without notice
© Copyright Siemens
— adjustable
Yes; From 10 to 499
— preset
10
Service data
● test-/initiation function / service data readable
Yes
Interrupts/diagnostics/status information
Diagnostics indication LED
● Status indicator digital input (green)
Yes
● Status indicator digital output (green)
Yes
Integrated Functions
Frequency measurement
● Number of frequency meters
Yes
4; up to 60 kHz (see "Technological Functions" manual)
controlled positioning
Yes
integrated function blocks (closed-loop control)
Yes; PID controller (see "Technological Functions" manual)
PID controller
Yes
Number of pulse outputs
4; Pulse width modulation up to 2.5 kHz (see "Technological Functions"
Manual)
Limit frequency (pulse)
2.5 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputs
Yes
● between the channels
No
● between the channels and backplane bus
Yes
Potential separation digital outputs
● Potential separation digital outputs
Yes
● between the channels
Yes
● between the channels, in groups of
8
● between the channels and backplane bus
Yes
Potential separation analog inputs
● Potential separation analog inputs
Yes; common for analog I/O
● between the channels
No
● between the channels and backplane bus
Yes
Potential separation analog outputs
● Potential separation analog outputs
Yes; common for analog I/O
● between the channels
No
● between the channels and backplane bus
Yes
Isolation
Isolation tested with
600 V DC
Ambient conditions
Ambient temperature during operation
● min.
0 °C
● max.
60 °C
configuration / header
Configuration software
● STEP 7
Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP
203
● STEP 7 Lite
No
configuration / programming / header
● Command set
see instruction list
● Nesting levels
8
● System functions (SFC)
see instruction list
● System function blocks (SFB)
see instruction list
Programming language
— LAD
Yes
— FBD
Yes
— STL
Yes
— SCL
Yes
— CFC
Yes
— GRAPH
Yes
— HiGraph®
Yes
Know-how protection
● User program protection/password protection
6ES73146CH040AB0
Page 10/11
Yes
5/6/2024
Subject to change without notice
© Copyright Siemens
● Block encryption
Yes; With S7 block Privacy
Dimensions
Width
120 mm
Height
125 mm
Depth
130 mm
Weights
Weight, approx.
680 g
last modified:
4/25/2024
6ES73146CH040AB0
Page 11/11
5/6/2024
Subject to change without notice
© Copyright Siemens