0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES7522-1BL01-0AB0

6ES7522-1BL01-0AB0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 6ES7522-1BL01-0AB0 - Digital Output Module, 32 Outputs, 24 VDC

  • 数据手册
  • 价格&库存
6ES7522-1BL01-0AB0 数据手册
Data sheet 6ES7522-1BL01-0AB0 SIMATIC S7-1500, digital output module DQ 32x24V DC/0.5A HF; 32 channels in groups of 8; 4 A per group; single-channel diagnostics; substitute value, switching cycle counter for connected actuators. the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:2015. front connector (screw terminals or push-in) to be ordered separately General information Product type designation DQ 32x24VDC/0.5A HF HW functional status From FS02 Firmware version V1.1.0 Product function ● I&M data Yes; I&M0 to I&M3 ● Isochronous mode Yes ● Prioritized startup Yes Engineering with ● STEP 7 TIA Portal configurable/integrated from version V13 SP1 / - ● STEP 7 configurable/integrated from version V5.5 SP3 / - ● PROFIBUS from GSD version/GSD revision V1.0 / V5.1 ● PROFINET from GSD version/GSD revision V2.3 / - Operating mode ● DQ Yes ● DQ with energy-saving function No ● PWM No ● Cam control (switching at comparison values) No ● Oversampling No ● MSO Yes ● Integrated operating cycle counter Yes Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes; through internal protection with 7 A per group Input current Current consumption, max. 60 mA output voltage / header Rated value (DC) 24 V Power Power available from the backplane bus 1.1 W Power loss Power loss, typ. 3.5 W Digital outputs Type of digital output Transistor Number of digital outputs 32 Current-sourcing Yes Digital outputs, parameterizable Yes 6ES75221BL010AB0 Page 1/3 5/6/2024 Subject to change without notice © Copyright Siemens Short-circuit protection ● Response threshold, typ. Yes; Clocked electronically 1A Limitation of inductive shutdown voltage to L+ (-53 V) Controlling a digital input Yes Switching capacity of the outputs ● with resistive load, max. 0.5 A ● on lamp load, max. 5W Load resistance range ● lower limit 48 Ω ● upper limit 12 kΩ Output voltage ● for signal "1", min. L+ (-0.8 V) Output current ● for signal "1" rated value 0.5 A ● for signal "1" permissible range, max. 0.5 A ● for signal "0" residual current, max. 0.5 mA Output delay with resistive load ● "0" to "1", max. 100 µs ● "1" to "0", max. 500 µs Parallel switching of two outputs ● for logic links Yes ● for uprating No ● for redundant control of a load Yes Switching frequency ● with resistive load, max. 100 Hz ● with inductive load, max. 0.5 Hz; According to IEC 60947-5-1, DC-13 ● on lamp load, max. 10 Hz Total current of the outputs ● Current per channel, max. 0.5 A; see additional description in the manual ● Current per group, max. 4 A; see additional description in the manual ● Current per module, max. 16 A; see additional description in the manual Cable length ● shielded, max. 1 000 m ● unshielded, max. 600 m Isochronous mode Execution and activation time (TCO), min. 70 µs Bus cycle time (TDP), min. 250 µs Interrupts/diagnostics/status information Diagnostics function Yes Substitute values connectable Yes Alarms ● Diagnostic alarm Yes ● Maintenance interrupt Yes Diagnoses ● Monitoring the supply voltage Yes ● Wire-break Yes ● Short-circuit Yes ● Group error Yes Diagnostics indication LED ● RUN LED Yes; green LED ● ERROR LED Yes; red LED ● MAINT LED Yes; Yellow LED ● Monitoring of the supply voltage (PWR-LED) Yes; green LED ● Channel status display Yes; green LED ● for channel diagnostics Yes; red LED ● for module diagnostics Yes; red LED Potential separation Potential separation channels ● between the channels No ● between the channels, in groups of 8 6ES75221BL010AB0 Page 2/3 5/6/2024 Subject to change without notice © Copyright Siemens ● between the channels and backplane bus Yes Isolation Isolation tested with 707 V DC (type test) Standards, approvals, certificates Suitable for safety functions No Suitable for safety-related tripping of standard modules Yes; From FS02 Highest safety class achievable for safety-related tripping of standard modules ● Performance level according to ISO 13849-1 PL d ● Category according to ISO 13849-1 Cat. 3 ● SIL acc. to IEC 62061 SIL 2 ● remark on safety-oriented shutdown https://support.industry.siemens.com/cs/de/en/view/39198632 product functions / security / header signed firmware update No data integrity No Ambient conditions Ambient temperature during operation ● horizontal installation, min. -30 °C; From FS03 ● horizontal installation, max. 60 °C ● vertical installation, min. -30 °C; From FS03 ● vertical installation, max. 40 °C Altitude during operation relating to sea level ● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual Dimensions Width 35 mm Height 147 mm Depth 129 mm Weights Weight, approx. 280 g last modified: 3/12/2024 6ES75221BL010AB0 Page 3/3 5/6/2024 Subject to change without notice © Copyright Siemens
6ES7522-1BL01-0AB0 价格&库存

很抱歉,暂时无法提供与“6ES7522-1BL01-0AB0”相匹配的价格&库存,您可以联系我们找货

免费人工找货
6ES7522-1BL01-0AB0
    •  国内价格
    • 1+6008.73875

    库存:1