Data sheet
6GK5552-0AR00-2AR2
SCALANCE XR552-12M; managed IE switch; 19" rack; 4x 1000/10000
Mbit/s SFP+; 12x 100/1000 Mbit/s 4-port media modules, electrical,
electrical PoE or optical; LED diagnostics; error signaling contact;
Select/set pushbutton, PROFINET IO device, network management,
integrated redundancy manager; office features (RSTP, VLAN, IGMP, ...);
C-plug in scope of delivery Layer 3 integrated; ports in the front
product type designation
SCALANCE XR552-12M
transfer rate
transfer rate
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, 10 Gbit/s
interfaces / for communication / integrated
number of electrical connections
● for network components or terminal equipment
RJ45
● for Power-over-Ethernet / for network components
or terminal equipment
12
number of electrical connections
● for SFP+
4
interfaces / for communication / plug-in
number of 100 Mbit/s ST(BFOC) ports
● for multimode
48
● for single mode (LD)
48
number of 1000 Mbit/s SC ports
● for multimode
48
● for single mode (LD)
48
number of electrical connections
● for SFP
4
● for SFP+
4
interfaces / other
number of electrical connections
● for operator console
1
● for management purposes
1
● for signaling contact
1
● for media module
12
● for power supply
1
type of electrical connection
● for operator console
RJ11
● for management purposes
RJ45
● for signaling contact
2-pole terminal block
● for power supply
4-pole terminal block
design of the removable storage
● C-PLUG/KEY-PLUG
product feature / hot-swappable interface modules
Yes
Yes
signal inputs/outputs
operating voltage / of the signaling contacts
6GK55520AR002AR2
Page 1/2
12.22.2020
Subject to change without notice
© Copyright Siemens
● at DC / rated value
24 V
operational current / of the signaling contacts
● at DC / maximum
0.1 A
supply voltage, current consumption, power loss
type of voltage supply / redundant power supply unit
No
supplied active power / of PSE / with PoE
● per port / maximum
30 W
● total / maximum
180 W
type of voltage / 1 / of the supply voltage
DC
● supply voltage / 1 / rated value
24 V
● power loss [W] / 1 / rated value
34.08 W
● supply voltage / 1 / rated value
19.2 ... 28.8 V
● consumed current / 1 / maximum
12.5 A
● type of electrical connection / 1 / for power supply
4-pole terminal block
● product component / 1 / fusing at power supply input
Yes
ambient conditions
ambient temperature
● during operation
0 ... 60 °C
● during storage
-40 ... +70 °C
● during transport
-40 ... +70 °C
● note
Operation with integral fan, replaceable
relative humidity
● at 25 °C / without condensation / during operation /
maximum
protection class IP
95 %
IP20
design, dimensions and weights
design
19" rack
number of modular height units / relating to 19-inch
cabinet
3
width
449 mm
height
130.8 mm
depth
305 mm
net weight
10 kg
fastening method
● 19-inch installation
Yes
● 35 mm top hat DIN rail mounting
No
● wall mounting
No
● S7-300 rail mounting
No
● S7-1500 rail mounting
No
type of cable outlet
Cable outlet at front
product features, product functions, product components / general
cascading in cases of star topology
any (depending only on signal propagation time)
product functions / management, configuration, engineering
product function
● CLI
Yes
● web-based management
Yes
● MIB support
Yes
● TRAPs via email
Yes
● configuration with STEP 7
Yes
● RMON
Yes
● port mirroring
Yes
● multiport mirroring
Yes
● CoS
Yes
● PROFINET IO diagnosis
Yes
PROFINET conformity class
B
product function / switch-managed
Yes
telegram length / for Ethernet / maximum
9216 byte
protocol / is supported
6GK55520AR002AR2
Page 2/3
12.22.2020
Subject to change without notice
© Copyright Siemens
● Telnet
Yes
● HTTP
Yes
● HTTPS
Yes
● TFTP
Yes
● FTP
Yes
● BOOTP
Yes
● GMRP
Yes
● DCP
Yes
● LLDP
Yes
● SNMP v1
Yes
● SNMP v2
Yes
● SNMP v3
Yes
● IGMP (snooping/querier)
Yes
identification & maintenance function
● I&M0 - device-specific information
Yes
● I&M1 – higher level designation/location designation
Yes
product functions / diagnostics
product function
● port diagnostics
Yes
● statistics Packet Size
Yes
● statistics packet type
Yes
● error statistics
Yes
● SysLog
Yes
product functions / VLAN
product function
● VLAN - port based
Yes
● VLAN - protocol-based
Yes
● VLAN - IP-based
Yes
● VLAN dynamic
Yes
number of VLANs / maximum
255
number of VLANs - dynamic / maximum
255
protocol / is supported / GVRP
Yes
product functions / DHCP
product function
● DHCP client
Yes
● DHCP Option 82
Yes
● DHCP Option 66
Yes
● DHCP Option 67
Yes
product functions / routing
service / routing / note
IP routing integrated
product function
● static IP routing
Yes
● static IP routing IPv6
Yes
● dynamic IP routing
Yes
● dynamic IP routing IPv6
Yes
protocol / is supported
● RIPv2
Yes
● RIPnG for IPv6
Yes
● OSPFv2
Yes
● OSPFv3 for IPv6
Yes
● VRRP
Yes
● VRRP for IPv6
Yes
product functions / redundancy
product function
● ring redundancy
Yes
● High Speed Redundancy Protocol (HRP)
Yes
● high speed redundancy protocol (HRP) with
redundancy manager
Yes
6GK55520AR002AR2
Page 3/4
12.22.2020
Subject to change without notice
© Copyright Siemens
● high speed redundancy protocol (HRP) with standby
redundancy
protocol / is supported / Media Redundancy Protocol
(MRP)
Yes
Yes
product function
● media redundancy protocol (MRP) with redundancy
manager
Yes
● Media Redundancy Protocol Interconnection (MRPI)
Yes
● redundancy procedure STP
Yes
● redundancy procedure RSTP
Yes
● redundancy procedure RSTP+
Yes
● redundancy procedure MSTP
Yes
● passive listening
Yes
protocol / is supported
● LACP
Yes
product functions / security
product function
● ACL - MAC-based
Yes
● ACL - port/MAC-based
Yes
● IEEE 802.1x (radius)
Yes
● broadcast/multicast/unicast limiter
Yes
● broadcast blocking
Yes
protocol / is supported
● SSH
Yes
product functions / time
product function
● SICLOCK support
Yes
protocol / is supported
● NTP
Yes
● SNTP
Yes
type of time synchronization
IEEE 1588
standards, specifications, approvals
standard
● for FM
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2,
Group IIC, T4
● for hazardous zone
EN 60079-0: 2009, EN60079-15: 2010, II 3 G Ex nA IIC T4 Gc, KEMA
07 ATEX 0145 X
● for safety / from CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1-03
● for hazardous zone / from CSA and UL
ISA 12.12.01-2012 (Hazardous Location), Class 1 / Division 2 / Group
A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4
● for emitted interference
EN 61000-6-4 (Class A)
● for interference immunity
EN 61000-6-2
standards, specifications, approvals / CE
certificate of suitability / CE marking
Yes
standards, specifications, approvals / other
certificate of suitability
EN 61000-6-2, EN 61000-6-4
● C-Tick
Yes
● E1 approval
No
● E1 approval
No
● KC approval
Yes
further information / internet-Links
Internet-Link
● to web page: selection aid TIA Selection Tool
http://www.siemens.com/snst
● to website: Industrial communication
http://www.siemens.com/simatic-net
● to website: Industry Mall
https://mall.industry.siemens.com
● to website: Information and Download Center
http://www.siemens.com/industry/infocenter
● to website: Image database
http://automation.siemens.com/bilddb
● to website: CAx-Download-Manager
http://www.siemens.com/cax
6GK55520AR002AR2
Page 4/5
12.22.2020
Subject to change without notice
© Copyright Siemens
● to website: Industry Online Support
https://support.industry.siemens.com
security information
security information
Siemens provides products and solutions with industrial security
functions that support the secure operation of plants, solutions,
machines, equipment and/or networks. They are important components
in a holistic industrial security concept. With this in mind, Siemens’
products and solutions undergo continuous development. Siemens
recommends strongly that you regularly check for product updates. For
the secure operation of Siemens products and solutions, it is necessary
to take suitable preventive action(e.g. cell protection concept) and
integrate each component into a holistic, state-of-the-art industrial
security concept. Third-party products that may be in use should also be
considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity. To stay informed about
product updates as they occur, sign up for a product-specific newsletter.
For more information, visit http://support.automation.siemens.com.
(V3.4)
last modified:
12/18/2020
6GK55520AR002AR2
Page 5/5
12.22.2020
Subject to change without notice
© Copyright Siemens