0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6GK57882GD000AB0

6GK57882GD000AB0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    RF 接入点 2.41GHz ~ 2.48GHz,4.9GHz ~ 5.8GHz 802.11 a/b/g/h/n M-12 1Gbps

  • 数据手册
  • 价格&库存
6GK57882GD000AB0 数据手册
Data sheet product type designation 6GK5788-2GD00-0AB0 W788-2 M12 (USA) IWLAN Access Point, SCALANCE W788-2 M12, 2 radios, 6 N-CON antenna port, iFeatures support via KEY-PLUG, IEEE 802.11a/b/g/h/n, 2.4/5GHz, gross 450 Mbit/s per radio, 1x M12 max. 1 Gbit/s, PoE, redundant 24 V DC,M12 A-coded IP65, -20..+60 °C, plug slot, WPA2/802.11i/e, observe national approvals! CERT ID: RAPN-W2-M12E3, includes: MPCIE-R1-ABGN-U3, scope of delivery: Manuals on CDROM, German/English, M12 sealing caps, only for operation in the USA. transfer rate transfer rate ● with WLAN / maximum 450 Mbit/s ● for Industrial Ethernet 10, 100, 1000 Mbit/s transfer rate / for Industrial Ethernet ● minimum 10 Mbit/s ● maximum 1000 Mbit/s interfaces number of electrical connections ● for network components or terminal equipment 1 ● for power supply 1 ● for redundant voltage supply 1 type of electrical connection ● for network components or terminal equipment M12 interface (8-pole, X-coded), PoE ● for power supply M12 interface (4-pole, A-coded) design of the removable storage ● C-PLUG Yes ● KEY-PLUG Yes memory design of the removable storage ● C-PLUG Yes ● KEY-PLUG Yes interfaces / wireless number of radio cards / permanently installed 2 transmission mode / for multiple input multiple output (MIMO) 3x3 number of spatial streams 3 number of electrical connections / for external antenna(s) 6 type of electrical connection / for external antenna(s) N-Connect (socket) product feature / external antenna can be mounted directly on device Yes supply voltage, current consumption, power loss type of voltage / of the supply voltage DC supply voltage ● from Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af 48 V ● from Power-over-Ethernet according to IEEE802.3at for type 2 50 V consumed current 6GK57882GD000AB0 Page 1/5 7/7/2022 Subject to change without notice © Copyright Siemens ● at DC / at 24 V / typical 0.63 A ● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 0.22 A ● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 0.3 A power loss [W] ● at DC / at 24 V / typical 15 W ● with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical 10.7 W ● with Power-over-Ethernet according to IEEE802.3at for type 2 / typical 15 W supply voltage / 1 ● from M12 Power Connector (A-coded) for redundant power supply 19.2 V supply voltage / 2 ● from M12 Power Connector (A-coded) for redundant power supply 28.8 V ambient conditions ambient temperature ● during operation -20 ... +60 °C ● during storage -40 ... +85 °C ● during transport -40 ... +85 °C relative humidity / at 25 °C / without condensation / during operation / maximum 90 % ambient condition / for operation When used under hazardous conditions (Zone 2), the SCALANCE W788-x or W748-x product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. protection class IP IP65 design, dimensions and weights width / of the enclosure / without antenna 200 mm height / of the enclosure / without antenna 176 mm depth / of the enclosure / without antenna 79 mm net weight 1.7 kg fastening method For 35 mm DIN rail mounting an additional mounting adapter is required ● S7-300 rail mounting Yes ● S7-1500 rail mounting Yes ● 35 mm top hat DIN rail mounting Yes ● wall mounting Yes radio frequencies operating frequency ● for WLAN in 2.4 GHz frequency band 2.41 ... 2.48 GHz; depending on the country approvals ● for WLAN in 5 GHz frequency band 4.9 ... 5.8 GHz; depending on the country approvals product features, product functions, product components / general product function / Access Point Mode Yes product function / client Mode Yes number of SSIDs 16 product function ● iPCF Access Point Yes; Only in combination with the 'KEY-PLUG W780 iFeatures' ● iPCF client Yes; Only in combination with the 'KEY-PLUG W780 iFeatures' or 'KEYPLUG W740 iFeatures' ● iPCF-MC Access Point Yes; Only in combination with the 'KEY-PLUG W780 iFeatures' ● iPCF-MC client Yes; Only in combination with 'KEY-PLUG W780 iFeatures' or 'KEYPLUG W740 iFeatures' number of iPCF-capable radio modules 2 product function / iREF No; In combination only with 'KEY-PLUG W780 iFeatures' number of iREF-capable radio modules 2 product function / iPRP Yes; In combination with the 'KEY-PLUG W780 iFeatures' only product functions / management, configuration, engineering number of manageable IP addresses / in client 8 product function ● CLI 6GK57882GD000AB0 Page 2/5 Yes 7/7/2022 Subject to change without notice © Copyright Siemens ● web-based management Yes ● MIB support Yes ● TRAPs via email Yes ● configuration with STEP 7 Yes ● configuration with STEP 7 in the TIA Portal Yes ● operation with IWLAN controller No ● operation with Enterasys WLAN controller No ● forced roaming on IP down with IWLAN Yes ● forced roaming on link down with IWLAN Yes ● WDS Yes protocol / is supported ● Address Resolution Protocol (ARP) Yes ● ICMP Yes ● Telnet Yes ● HTTP Yes ● HTTPS Yes ● TFTP Yes ● DCP Yes ● LLDP Yes identification & maintenance function ● I&M0 - device-specific information Yes ● I&M1 – higher level designation/location designation Yes product functions / diagnostics product function ● PROFINET IO diagnosis Yes ● link check No ● connection monitoring IP-Alive No ● localization via Aeroscout Yes ● SysLog Yes protocol / is supported ● SNMP v1 Yes ● SNMP v2 Yes ● SNMP v3 Yes product functions / VLAN product function ● function VLAN with IWLAN Yes product functions / DHCP product function ● DHCP client Yes ● DHCP server Yes ● DHCP Option 82 Yes product functions / redundancy protocol / is supported ● STP/RSTP Yes ● MSTP Yes ● RSTP Yes product functions / security product function ● ACL - MAC-based Yes ● management security, ACL-IP based Yes ● IEEE 802.1x (radius) Yes ● NAT/NAPT Yes ● access protection according to IEEE802.11i Yes ● WPA/WPA2 Yes ● TKIP/AES Yes protocol / is supported ● SSH Yes ● RADIUS Yes product functions / time 6GK57882GD000AB0 Page 3/5 7/7/2022 Subject to change without notice © Copyright Siemens protocol / is supported ● NTP Yes ● SNTP Yes ● SIMATIC time synchronization (SIMATIC Time) Yes standards, specifications, approvals standard ● for FM FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 ● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1 certificate of suitability ● EC Declaration of Conformity Yes ● CE marking Yes ● C-Tick Yes ● E1 approval Yes ● railway application in accordance with EN 50155 Yes ● railway application in accordance with EN 50121-4 Yes ● fire protection in accordance with EN 45545-2 Yes ● NEMA TS2 No ● IEC 61375 No ● IEC 61850-3 No ● NEMA4X No ● Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af Yes ● Power-over-Ethernet according to IEEE802.3at for type 2 Yes standard for wireless communication ● IEEE 802.11a Yes ● IEEE 802.11b Yes ● IEEE 802.11e Yes ● IEEE 802.11g Yes ● IEEE 802.11h Yes ● IEEE 802.11i Yes ● IEEE 802.11n Yes wireless approval For operation in the USA, you will find more information under: www.siemens.de/funkzulassungen standards, specifications, approvals / marine classification Marine classification association ● American Bureau of Shipping Europe Ltd. (ABS) Yes ● French marine classification society (BV) Yes ● DNV GL Yes ● Korean Register of Shipping (KRS) Yes ● Lloyds Register of Shipping (LRS) Yes ● Nippon Kaiji Kyokai (NK) Yes ● Polski Rejestr Statkow (PRS) Yes ● Royal Institution of Naval Architects (RINA) Yes standards, specifications, approvals / hazardous environments standard / for hazardous zone ● from CSA and UL certificate of suitability / CCC / for hazardous zone according to GB standard EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC Yes further information / internet-Links Internet-Link ● to website: TIA Selection Tool http://www.siemens.com/tia-selection-tool ● to web page: selection aid TIA Selection Tool http://www.siemens.com/tia-selection-tool ● to the website: IWLAN http://www.siemens.com/iwlan ● to website: Industry Mall https://mall.industry.siemens.com ● to website: Information and Download Center http://www.siemens.com/industry/infocenter ● to website: Image database http://automation.siemens.com/bilddb ● to website: CAx-Download-Manager http://www.siemens.com/cax 6GK57882GD000AB0 Page 4/5 7/7/2022 Subject to change without notice © Copyright Siemens ● to website: Industry Online Support https://support.industry.siemens.com security information security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action(e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) last modified: 1/21/2021 6GK57882GD000AB0 Page 5/5 7/7/2022 Subject to change without notice © Copyright Siemens
6GK57882GD000AB0 价格&库存

很抱歉,暂时无法提供与“6GK57882GD000AB0”相匹配的价格&库存,您可以联系我们找货

免费人工找货