Data sheet for SINAMICS G120C Article No. : 6SL3210-1KE22-6AF1 Client order no. : Order no. : Offer no. : Remarks : Figure similar Item no. : Consignment no. : Project : Rated data Inputs / outputs Input Standard digital inputs Number of phases 3 AC Number 6 Line voltage 380 ... 480 V +10 % -20 % Switching level: 0→1 11 V Line frequency 47 ... 63 Hz Switching level: 1→0 5V Rated current (LO) 33.00 A Max. inrush current 15 mA Rated current (HO) 24.10 A Fail-safe digital inputs Output Number Number of phases 3 AC Rated voltage 1 Digital outputs 400V IEC 480V Rated power (LO) 11.00 kW Rated power (HO) 7.50 kW Rated current (LO) 25.00 A NEC 1) Number as relay changeover contact 1 15.00 hp Output (resistive load) DC 30 V, 0.5 A 10.00 hp Number as transistor 1 Output (resistive load) DC 30 V, 0.5 A Analog / digital inputs Rated current (HO) 16.50 A Rated current (IN) 26.00 A Number 1 (Differential input) Max. output current 33.00 A Resolution 10 bit Switching threshold as digital input Pulse frequency 4 kHz Output frequency for vector control 0 ... 240 Hz 0→1 4V Output frequency for V/f control 0 ... 550 Hz 1→0 1.6 V Analog outputs Overload capability Number Low Overload (LO) 150 % base load current IL for 3 s, followed by 110 % base load current IL for 57 s in a 300 s cycle time PTC/ KTY interface 1 motor temperature sensor input, sensors that can be connected PTC, KTY and Thermo-Click, accuracy ±5 °C High Overload (HO) 200% base load current IH for 3 s, followed by 150% base load current IH for 57 s in a 300 s cycle time General tech. specifications Power factor λ 0.70 ... 0.85 Offset factor cos φ 0.95 Efficiency η 0.97 Sound pressure level (1m) 66 dB Power loss 298.0 W Filter class (integrated) Class A 1 (Non-isolated output) Closed-loop control techniques V/f linear / square-law / parameterizable Yes V/f with flux current control (FCC) Yes V/f ECO linear / square-law Yes Sensorless vector control Yes Vector control, with sensor No Encoderless torque control No Torque control, with encoder No Communication Communication PROFINET, EtherNet/IP Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 2 Generated Thu May 9 12:39:07 CET 2024 Data sheet for SINAMICS G120C Article No. : 6SL3210-1KE22-6AF1 Ambient conditions Converter losses to IEC61800-9-2* Cooling Air cooling using an integrated fan Efficiency class IE2 Cooling air requirement 0.018 m³/s (0.636 ft³/s) 33.2 % Installation altitude 1,000 m (3,280.84 ft) Comparison with the reference converter (90% / 100%) Ambient temperature Operation -10 ... 40 °C (14 ... 104 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Storage -40 ... 70 °C (-40 ... 158 °F) I 100% 227.0 W (1.3 %) 257.0 W (1.5 %) 298.0 W (1.7 %) 152.0 W (0.9 %) 164.0 W (0.9 %) 180.0 W (1.0 %) 126.0 W (0.7 %) 132.0 W (0.8 %) Relative humidity Max. operation 95 % At 40 °C (104 °F), condensation and icing not permissible 50% Connections 25% Signal cable Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) Line side 50% Version Plug-in screw terminals Conductor cross-section 6.00 ... 16.00 mm² (AWG 10 ... AWG 6) Motor end Version Plug-in screw terminals Conductor cross-section 6.00 ... 16.00 mm² (AWG 10 ... AWG 6) Version Plug-in screw terminals Conductor cross-section 6.00 ... 16.00 mm² (AWG 10 ... AWG 6) Line length, max. 15 m (49.21 ft) PE connection On housing with M4 screw f The percentage values show the losses in relation to the rated apparent power of the converter. The diagram shows the losses for the points (as per standard IEC61800-9-2) of the relative torque generating current (I) over the relative motor stator frequency (f). The values are valid for the basic version of the converter without options/components. *calculated values 1) DC link (for braking resistor) 90% The output current and HP ratings are valid for the voltage range 440V-480V Max. motor cable length Shielded 50 m (164.04 ft) Unshielded 100 m (328.08 ft) Mechanical data Degree of protection IP20 / UL open type Frame size FSC Net weight 4.40 kg (9.70 lb) Dimensions Width 140 mm (5.51 in) Height 295 mm (11.61 in) Depth 208 mm (8.19 in) Standards Compliance with standards UL, cUL, CE, C-Tick (RCM) CE marking EMC Directive 2004/108/EC, LowVoltage Directive 2006/95/EC Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 2 Generated Thu May 9 12:39:07 CET 2024
6SL32101KE226AF1 价格&库存

很抱歉,暂时无法提供与“6SL32101KE226AF1”相匹配的价格&库存,您可以联系我们找货

免费人工找货