0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6SL32203YC181UP0

6SL32203YC181UP0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    G120X IP20 200...240V 3KW FSB UF

  • 数据手册
  • 价格&库存
6SL32203YC181UP0 数据手册
Data sheet for SINAMICS G120X Article No. : 6SL3220-3YC18-1UP0 Client order no. : Order no. : Offer no. : Remarks : Figure similar Item no. : Consignment no. : Project : Rated data Inputs / outputs Input Standard digital inputs Number of phases 3 AC Number 6 Line voltage 200 ... 240 V +10 % -20 % Switching level: 0 → 1 11 V Line frequency 47 ... 63 Hz Switching level: 1 → 0 5V Rated voltage 200V IEC 240V NEC Max. inrush current 15 mA Rated current (LO) 12.70 A 12.70 A Rated current (HO) 9.60 A 9.60 A Fail-safe digital inputs Number Output 1 Digital outputs Number of phases 3 AC Rated voltage 200V IEC 240V NEC Rated power (LO) 3.00 kW Rated power (HO) Rated current (LO) Number as relay changeover contact 2 Output (resistive load) DC 30 V, 5.0 A 4.00 hp Number as transistor 0 2.20 kW 3.00 hp Analog / digital inputs 13.60 A 13.60 A Number 2 (Differential input) Rated current (HO) 10.40 A 10.40 A Resolution 10 bit Rated current (IN) 14.10 A Max. output current 18.40 A Pulse frequency 4 kHz Output frequency for vector control 0 ... 200 Hz Output frequency for V/f control 0 ... 550 Hz Overload capability 1) Switching threshold as digital input 0→1 4V 1→0 1.6 V Analog outputs Number 1 (Non-isolated output) PTC/ KTY interface Low Overload (LO) 110% base load current IL for 60 s in a 300 s cycle time 1 motor temperature sensor input, sensors that can be connected PTC, KTY and Thermo-Click, accuracy ±5 °C Closed-loop control techniques High Overload (HO) 150% x base load current IH for 60 s within a 600 s cycle time General tech. specifications V/f linear / square-law / parameterizable Yes V/f with flux current control (FCC) Yes Power factor λ 0.70 ... 0.85 V/f ECO linear / square-law Yes Offset factor cos φ 0.96 Sensorless vector control Yes Efficiency η 0.96 Vector control, with sensor No Sound pressure level (1m) 63 dB Encoderless torque control No Power loss 3) 0.165 kW Torque control, with encoder No Filter class (integrated) Unfiltered EMC category (with accessories) without Safety function "Safe Torque Off" without Communication Communication PROFIBUS DP Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 4 Generated Sat Jul 9 09:49:06 CET 2022 Data sheet for SINAMICS G120X Article No. : 6SL3220-3YC18-1UP0 Ambient conditions Standard board coating type Class 3C2, according to IEC 60721-3-3: 2002 Cooling Air cooling using an integrated fan Cooling air requirement 0.018 m³/s (0.653 ft³/s) Installation altitude 1,000 m (3,280.84 ft) Ambient temperature Operation -20 ... 45 °C (-4 ... 113 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Storage -25 ... 55 °C (-13 ... 131 °F) Relative humidity Max. operation 95 % At 40 °C (104 °F), condensation and icing not permissible Mechanical data Degree of protection IP20 / UL open type Frame size FSB Net weight 5.8 kg (12.79 lb) Dimensions Width 100 mm (3.94 in) Height 275 mm (10.83 in) Depth 218 mm (8.58 in) Standards Compliance with standards UL, cUL, CE, C-Tick (RCM), EAC, KCC, SEMI F47, REACH CE marking EMC Directive 2004/108/EC, LowVoltage Directive 2006/95/EC Connections Signal cable Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) Converter losses to IEC61800-9-2* Efficiency class IE2 Comparison with the reference converter (90% / 100%) 45.6 % Line side Version screw-type terminal Conductor cross-section 1.50 ... 6.00 mm² (AWG 16 ... AWG 10) I 100% 122.0 W (2.2 %) 140.0 W (2.5 %) 165.0 W (2.9 %) 87.4 W (1.5 %) 95.4 W (1.7 %) 106.0 W (1.9 %) 73.5 W (1.3 %) 77.3 W (1.4 %) Motor end Version Screw-type terminals Conductor cross-section 1.50 ... 6.00 mm² (AWG 16 ... AWG 10) 50% DC link (for braking resistor) PE connection On housing with M4 screw 25% Max. motor cable length Shielded 150 m (492.13 ft) Unshielded 300 m (984.25 ft) 50% 90% f The percentage values show the losses in relation to the rated apparent power of the converter. The diagram shows the losses for the points (as per standard IEC61800-9-2) of the relative torque generating current (I) over the relative motor stator frequency (f). The values are valid for the basic version of the converter without options/components. *converted values 1) The output current and HP ratings are valid for the voltage range 220V-240V 3) Typical value. More information can be found in the element group "Converter losses to IEC 61800-9-2" in this datasheet. Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 4 Generated Sat Jul 9 09:49:06 CET 2022 Data sheet for SINAMICS G120X Article No. : 6SL3220-3YC18-1UP0 Operator panel: Intelligent Operator Panel (IOP-2) Screen Display design LCD color Screen resolution 320 x 240 Pixel Ambient conditions Ambient temperature Operation 0 ... 50 °C (32 ... 122 °F) 55 °C only with door installation kit Mechanical data Degree of protection IP55 / UL type 12 Net weight 0.134 kg (0.30 lb) Dimensions Storage -40 ... 70 °C (-40 ... 158 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Relative humidity at 25°C during Max. operation Width 70.00 mm (2.76 in) Height 106.85 mm (4.21 in) Depth 19.65 mm (0.77 in) 95 % Approvals Certificate of suitability Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 3 of 4 CE, cULus, EAC, KCC, RCM Generated Sat Jul 9 09:49:06 CET 2022 Data sheet for SINAMICS G120X Article No. : 6SL3220-3YC18-1UP0 I/O Extension Module Inputs / outputs Mechanical data Dimensions Digital inputs Number of digital inputs 1) 2 Width 71 mm (2.80 in) Conductor cross-section 0.5 … 1.5 mm² (AWG 21 … AWG 16) Height 117 mm (4.61 in) Alternatively 2 x 0.5 mm² Depth 27 mm (1.06 in) Input voltage (0→1) 11 V Input voltage (1→0) 5V Input voltage, max. 30 V Number of digital outputs 4 Conductor cross-section 1.5 mm² (AWG 16) Output 6: digital input; DI 7: P or M switch; DI COM: Input for Control Unit interface (24 V out, max. 250 mA) 2) The max. current depends on the temperature and the size of the connected converted. It varies between 2 A and 3 A at 30 V DC. analog inputs for the connection of Pt1000/Ni1000 temperature sensors. One of which can be optionally used as analog input. 4) Switchable between voltage (0 ... 10 V) and current (0 ... 20 mA) using a parameter 3) 2 Digital outputs current 2) 1) DI 2A Analog inputs Number of analog inputs 3) 2 Conductor cross-section 0.5 … 1.5 mm² (AWG 21 … AWG 16) alternatively 2*0.5 mm² Current 0 … 20 mA Analog outputs Number of analog outputs 2 Type of analog outputs 4) Non-isolated output Conductor cross-section 0.5 … 1.5 mm² (AWG 21 … AWG 16) Alternatively 2 x 0.5 mm² Output voltage 0 … 10 V Output current 0 … 20 mA Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 4 of 4 Generated Sat Jul 9 09:49:06 CET 2022
6SL32203YC181UP0 价格&库存

很抱歉,暂时无法提供与“6SL32203YC181UP0”相匹配的价格&库存,您可以联系我们找货

免费人工找货