0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6SL32203YE340UP0

6SL32203YE340UP0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    G120X IP20 380...480V 30KW FSD U

  • 数据手册
  • 价格&库存
6SL32203YE340UP0 数据手册
Data sheet for SINAMICS G120X MLFB-Ordering data 6SL3220-3YE34-0UP0 Figure similar Client order no. : Item no. : Order no. : Consignment no. : Offer no. : Project : Remarks : Rated data General tech. specifications Input Number of phases 3 AC Line voltage 380 ... 480 V +10 % -20 % Line frequency 47 ... 63 Hz Rated voltage 400V IEC 480V NEC Rated current (LO) 59.00 A 49.00 A Rated current (HO) 47.00 A 41.00 A Output Number of phases 3 AC Rated voltage 400V IEC 480V NEC Rated power (LO) 30.00 kW 40.00 hp Rated power (HO) 22.00 kW 25.00 hp Rated current (LO) 60.00 A 52.00 A Rated current (HO) 45.00 A 40.00 A Rated current (IN) 62.00 A Max. output current 81.00 A Pulse frequency 4 kHz Output frequency for vector control 0 ... 200 Hz Output frequency for V/f control 0 ... 550 Hz Power factor λ 0.90 ... 0.95 Offset factor cos φ 0.99 Efficiency η 0.98 Sound pressure level (1m) 70 dB Power loss 0.770 kW Filter class (integrated) Unfiltered EMC category (with accessories) without Ambient conditions Standard board coating type Class 3C2, according to IEC 60721-33: 2002 Cooling Air cooling using an integrated fan Cooling air requirement 0.055 m³/s (1.942 ft³/s) Installation altitude 1000 m (3280.84 ft) Ambient temperature Operation -20 ... 45 °C (-4 ... 113 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Storage -25 ... 55 °C (-13 ... 131 °F) Relative humidity Max. operation 95 % At 40 °C (104 °F), condensation and icing not permissible Overload capability Low Overload (LO) 110% base load current IL for 60 s in a 300 s cycle time High Overload (HO) 150% x base load current IH for 60 s within a 600 s cycle time Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 3 Generated Fri Jan 22 00:09:55 CET 2021 Data sheet for SINAMICS G120X MLFB-Ordering data 6SL3220-3YE34-0UP0 Figure similar Mechanical data Degree of protection IP20 / UL open type Size FSD Net weight 17 kg (37.48 lb) Width 200 mm (7.87 in) Height 472 mm (18.58 in) Depth 248 mm (9.76 in) Inputs / outputs Standard digital inputs Number 6 Switching level: 0→1 11 V Switching level: 1→0 5V Max. inrush current 15 mA Closed-loop control techniques V/f linear / square-law / parameterizable Yes V/f with flux current control (FCC) Yes V/f ECO linear / square-law Yes Sensorless vector control Yes Vector control, with sensor No Encoderless torque control Yes Torque control, with encoder No Communication Communication PROFIBUS DP Connections Signal cable Fail-safe digital inputs Number 1 Digital outputs Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) Line side Number as relay changeover contact 2 Version screw-type terminal Output (resistive load) DC 30 V, 5.0 A Conductor cross-section 10.00 ... 35.00 mm² (AWG 8 ... AWG 2) Number as transistor 0 Analog / digital inputs Number 2 (Differential input) Resolution 10 bit Motor end Version Screw-type terminals Conductor cross-section 10.00 ... 35.00 mm² (AWG 8 ... AWG 2) DC link (for braking resistor) Switching threshold as digital input PE connection 0→1 4V 1→0 1.6 V Analog outputs Number Screw-type terminals Max. motor cable length Shielded 200 m (656.17 ft) Unshielded 300 m (984.25 ft) 1 (Non-isolated output) PTC/ KTY interface 1 motor temperature sensor input, sensors that can be connected: PTC, KTY and Thermo-Click, accuracy ±5 °C Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 3 Generated Fri Jan 22 00:09:55 CET 2021 Data sheet for SINAMICS G120X MLFB-Ordering data 6SL3220-3YE34-0UP0 Figure similar Converter losses to EN 50598-2* Efficiency class IE2 Comparison with the reference converter (90% / 100%) -41.90 % Standards I 100% 50% 25% 594.2 W (1.43 %) 688.2 W (1.66 %) 834.3 W (2.01 %) 355.1 W (0.85 %) 391.0 W (0.94 %) 440.1 W (1.06 %) 274.7 W (0.66 %) 291 W (0.70 %) 50% 90% Compliance with standards UL, cUL, CE, C-Tick (RCM), EAC, KCC, SEMI F47, REACH CE marking EMC Directive 2004/108/EC, Low-Voltage Directive 2006/95/EC f The percentage values show the losses in relation to the rated apparent power of the converter. The diagram shows the losses for the points (as per standard EN 50598) of the relative torque generating current (I) over the relative motor stator frequency(f). The values are valid for the basic version of the converter without options/components. *converted values Operator panel: Intelligent Operator Panel (IOP-2) Screen Ambient conditions Display design LCD colors Screen resolution 320 x 240 Pixel Mechanical data Degree of protection IP55 / UL type 12 Net weight 0.13 kg (0.30 lb) Width 70.0 mm (2.76 in) Height 106.85 mm (4.21 in) Depth 19.65 mm (0.77 in) Ambient temperature during Operation 0 ... 50 °C (32 ... 122 °F) x 55 °C only with door mounting kit Storage -40 ... 70 °C (-40 ... 158 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Relative humidity at 25°C during Max. operation 95 % Approvals Certificate of suitability CE, cULus, EAC, KCC, RCM Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 3 of 3 Generated Fri Jan 22 00:09:55 CET 2021
6SL32203YE340UP0 价格&库存

很抱歉,暂时无法提供与“6SL32203YE340UP0”相匹配的价格&库存,您可以联系我们找货

免费人工找货