6SL32301YE260AP0

6SL32301YE260AP0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    G120X IP20 380-480V 11KW FSC C2

  • 数据手册
  • 价格&库存
6SL32301YE260AP0 数据手册
Data sheet for SINAMICS G120X Article No. : 6SL3230-1YE26-0AP0 Client order no. : Order no. : Offer no. : Remarks : Figure similar Item no. : Consignment no. : Project : Rated data Inputs / outputs Input Standard digital inputs Number of phases 3 AC Number 6 Line voltage 380 ... 480 V +10 % -20 % Switching level: 0 → 1 11 V Line frequency 47 ... 63 Hz Switching level: 1 → 0 5V Rated voltage 400V IEC 480V NEC Max. inrush current 15 mA Rated current (LO) 24.50 A 21.30 A Rated current (HO) 18.25 A 14.00 A Output Fail-safe digital inputs Number 1 Digital outputs Number of phases 3 AC Rated voltage Number as relay changeover contact 2 Output (resistive load) DC 30 V, 5.0 A 0 400V IEC 480V Rated power (LO) 11.00 kW 15.00 hp Number as transistor Rated power (HO) 7.50 kW 10.00 hp Analog / digital inputs Rated current (LO) 26.00 A 21.00 A Number 2 (Differential input) Rated current (HO) 18.00 A 14.00 A Resolution 10 bit Rated current (IN) 27.00 A Max. output current 35.00 A Pulse frequency 4 kHz Output frequency for vector control 0 ... 200 Hz Output frequency for V/f control 0 ... 550 Hz NEC 1) Overload capability Switching threshold as digital input 0→1 4V 1→0 1.6 V Analog outputs Number 1 (Non-isolated output) PTC/ KTY interface Low Overload (LO) 110% base load current IL for 60 s in a 300 s cycle time 1 motor temperature sensor input, sensors that can be connected PTC, KTY and Thermo-Click, accuracy ±5 °C Closed-loop control techniques High Overload (HO) 150% x base load current IH for 60 s within a 600 s cycle time General tech. specifications V/f linear / square-law / parameterizable Yes V/f with flux current control (FCC) Yes Power factor λ 0.70 ... 0.85 V/f ECO linear / square-law Yes Offset factor cos φ 0.96 Sensorless vector control Yes Efficiency η 0.98 Vector control, with sensor No Sound pressure level (1m) 67 dB Encoderless torque control No Power loss 3) 0.344 kW Torque control, with encoder No Filter class (integrated) RFI suppression filter for Category C2 EMC category (with accessories) Category C2 Safety function "Safe Torque Off" without Communication Communication PROFIBUS DP Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 2 Generated Sat Jul 9 10:08:48 CET 2022 Data sheet for SINAMICS G120X Article No. : 6SL3230-1YE26-0AP0 Ambient conditions Standard board coating type Class 3C3, according to IEC 60721-3-3: 2002 Cooling Air cooling using an integrated fan Cooling air requirement 0.018 m³/s (0.653 ft³/s) Installation altitude 1,000 m (3,280.84 ft) Ambient temperature Operation -20 ... 45 °C (-4 ... 113 °F) Transport -40 ... 70 °C (-40 ... 158 °F) Storage -25 ... 55 °C (-13 ... 131 °F) Relative humidity Max. operation 95 % At 40 °C (104 °F), condensation and icing not permissible Mechanical data Degree of protection IP20 / UL open type Frame size FSC Net weight 7.66 kg (16.89 lb) Dimensions Width 140 mm (5.51 in) Height 295 mm (11.61 in) Depth 218 mm (8.58 in) Standards Compliance with standards UL, cUL, CE, C-Tick (RCM), EAC, KCC, SEMI F47, REACH CE marking EMC Directive 2004/108/EC, LowVoltage Directive 2006/95/EC Connections Signal cable Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) Converter losses to IEC61800-9-2* Efficiency class IE2 Comparison with the reference converter (90% / 100%) 36.8 % Line side Version screw-type terminal Conductor cross-section 1.50 ... 16.00 mm² (AWG 16 ... AWG 6) I 100% 229.0 W (1.3 %) 272.0 W (1.5 %) 344.0 W (1.9 %) 148.0 W (0.8 %) 164.0 W (0.9 %) 188.0 W (1.0 %) 120.0 W (0.7 %) 127.0 W (0.7 %) Motor end Version Screw-type terminals Conductor cross-section 1.50 ... 16.00 mm² (AWG 16 ... AWG 6) 50% DC link (for braking resistor) PE connection On housing with M4 screw 25% Max. motor cable length Shielded 150 m (492.13 ft) 50% 90% f The percentage values show the losses in relation to the rated apparent power of the converter. The diagram shows the losses for the points (as per standard IEC61800-9-2) of the relative torque generating current (I) over the relative motor stator frequency (f). The values are valid for the basic version of the converter without options/components. *converted values 1) The output current and HP ratings are valid for the voltage range 440V-480V 3) Typical value. More information can be found in the element group "Converter losses to IEC 61800-9-2" in this datasheet. Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 2 Generated Sat Jul 9 10:08:48 CET 2022
6SL32301YE260AP0 价格&库存

很抱歉,暂时无法提供与“6SL32301YE260AP0”相匹配的价格&库存,您可以联系我们找货

免费人工找货