Data sheet
product description
6XV1850-2GH20
Patch cable, preferred length, preassembled with two RJ45 connectors
(10/100MB)
Industrial Ethernet TP Cord RJ45/RJ45, TP cord pre-assembled with 2
RJ45 plug, length 2 m.
suitability for use
Easy connection of terminal devices to the IE FC cabling system
cable designation
LI 02YSCY 2x2x0,15/0,98 PIMF ICCS GN
wire length
2m
electrical data
number of electrical connections
2
attenuation factor per length
● at 10 MHz / maximum
0.09 dB/m
● at 100 MHz / maximum
0.285 dB/m
● at 300 MHz / maximum
0.495 dB/m
● at 600 MHz / maximum
0.75 dB/m
impedance
● at 1 MHz ... 100 MHz
100 Ω
● at 10 MHz … 600 MHz
100 Ω
relative symmetrical tolerance
● of the characteristic impedance at 1 MHz … 100
MHz
15 %
● of the characteristic impedance at 10 MHz … 600
MHz
6%
transfer impedance per length / at 10 MHz
10 mΩ/m
loop resistance per length / maximum
300 mΩ/m
insulation resistance coefficient
150 GΩ·m
operating voltage
● RMS value
80 V
mechanical data
number of electrical cores
4
design of the shield
Overlapped aluminum-clad foil, sheathed in a braided screen of tinplated copper wires
core diameter
● of AWG26 insulated conductor
0.48 mm
outer diameter
● of inner conductor
0.48 mm
● of the wire insulation
0.98 mm
width / of cable sheath
5.8 mm
symmetrical tolerance of width / of cable sheath
0.2 mm
thickness / of cable sheath
3.7 mm
symmetrical tolerance of thickness / of cable sheath
0.2 mm
material
● of the wire insulation
6XV18502GH20
Page 1/2
polyethylene (PE)
7/8/2022
Subject to change without notice
© Copyright Siemens
● of cable sheath
PVC
color
● of the insulation of data wires
white/blue, white/orange
● of cable sheath
green
bending radius
● with single bend / minimum permissible
24 mm
● with multiple bends / minimum permissible
42 mm
weight per length
32 kg/km
ambient conditions
ambient temperature
● during operation
-40 ... +70 °C
● during storage
-40 ... +70 °C
● during transport
-40 ... +70 °C
● during installation
-40 ... +70 °C
fire behavior
flame resistant according to IEC 60332-2-1
chemical resistance
● to mineral oil
oil resistant according to IEC 60811-2-1 (4 h / 70°C)
● to grease
Conditional resistance
protection class IP
IP20
product features, product functions, product components / general
product feature
● halogen-free
No
● silicon-free
Yes
standards, specifications, approvals
UL/ETL listing / 300 V Rating
No
UL/ETL style / 600 V Rating
No
certificate of suitability
● EAC approval
Yes
● UL approval
Yes
standard for structured cabling
Cat5
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS)
No
● French marine classification society (BV)
No
● Det Norske Veritas (DNV)
No
● Germanische Lloyd (GL)
No
● Lloyds Register of Shipping (LRS)
No
● Nippon Kaiji Kyokai (NK)
No
● Polski Rejestr Statkow (PRS)
No
reference code
● according to IEC 81346-2
WG
● according to IEC 81346-2:2019
WGB
further information / internet-Links
Internet-Link
● to web page: selection aid TIA Selection Tool
http://www.siemens.com/tia-selection-tool
● to website: Industrial communication
http://www.siemens.com/simatic-net
● to website: Industry Mall
https://mall.industry.siemens.com
● to website: Information and Download Center
http://www.siemens.com/industry/infocenter
● to website: Selection guide for cables and
connectors
https://sie.ag/2QdlxcP
● to website: Image database
http://automation.siemens.com/bilddb
● to website: CAx-Download-Manager
http://www.siemens.com/cax
● to website: Industry Online Support
https://support.industry.siemens.com
last modified:
6XV18502GH20
Page 2/2
1/14/2022
7/8/2022
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“6XV18502GH20”相匹配的价格&库存,您可以联系我们找货
免费人工找货