Data sheet
US2:73CS35BFA
Enclosed soft starter, Controller 3RW40736BB35, Std. duty rating 200HP
@575V, Std. duty current rating 205A Control voltage 115Vac Enclosure
NEMA type 1, Indoor general purpose use
product brand name
Class 73
design of the product
Enclosed soft starter
special product feature
Control transformer, built-in overload relay and bypass contactor
included.
General technical data
weight [lb]
Height x Width x Depth [in]
106 lb
touch protection against electrical shock
NA for enclosed products
installation altitude [ft] at height above sea level maximum
6560 ft
36 × 22 × 20 in
ambient temperature [°F]
● during storage
-22 ... +149 °F
● during operation
-4 ... +104 °F
ambient temperature
● during storage
-30 ... +65 °C
● during operation
-20 ... +40 °C
country of origin
USA
Power and control electronics
manufacturer's article number of soft starter
3RW40736BB35
number of poles for main current circuit
3
design of power semiconductors (thyristors) for soft starter
control
2 controlled phases
operating range factor supply voltage rated value
0.85 ... 1.1
operating range factor of control voltage rated value
0.85 ... 1.1
operating condition for standard duty
Class 10 standard duty (350% of motor FLA for 10 seconds)
operating condition for severe duty
Class 20 severe duty (350% of motor FLA for 20 seconds)
Features and functions
ramp-up (soft starting)/ramp-down (soft stop)
Yes
starting voltage [%]
40 ... 100 %
stopping voltage [%]
40 ... 100 %
voltage ramp
Yes
ramp-up time
0 ... 20 s
ramp-down time
0 ... 20 s
torque control
No
adjustable current limitation
Yes
creep speed in both directions of rotation
No
pump ramp down
No
integrated bypass contact system
Yes
US2:73CS35BFA
Page 1/2
1.21.2021
Subject to change without notice
© Copyright Siemens
external isolation contactor
No
intrinsic device protection
Yes
overload protection
Yes
trip class
Class 5 / 15 / 20
reset function
Manual, automatic and remote
thermistor motor protection
No
inside-delta circuit
No
breakaway pulse
No
DC braking
No
combined braking
No
motor heating
No
configuration of control input 1
ON / OFF
configuration of control input 2
NA
configuration of control input 3
NA
configuration of control input 4
NA
configuration of relay output 1
ON / RUN
configuration of relay output 2
BYPASSED
configuration of relay output 3
OVERLOAD / FAILURE
configuration of relay output 4
NA
display version
4 LEDs
operating measured value display
No
product extension optional human machine interface
module
No
type of communication optional
None
error logbook
No
event list
No
slave pointer function
No
trace function
No
number of parameter sets
1
engineering software (Soft Starter ES)
No
disconnector functionality
No
Contactor
size of contactor
NA
Coil
type of voltage of the control supply voltage
AC
control supply voltage
● at AC at 50 Hz rated value
115 V
● at AC at 60 Hz rated value
115 V
Enclosure
degree of protection NEMA rating
1
degree of protection NEMA rating of the enclosure
NEMA Type 1
design of the housing
Indoor general purpose use
type of cooling
None
Mounting/wiring
mounting position
Vertical
fastening method
Surface mounting and installation
wire length between motor starter and motor maximum
300 m
type of electrical connection for supply voltage line-side
Box lug
tightening torque [lbf·in] for supply
180 ... 195 lbf·in
type of connectable conductor cross-sections at line-side
at AWG cables single or multi-stranded
3/0 AWG ... 600 MCM (front only) or 250 ... 500 MCM (back only) or 2x
2/0 AWG ... 2x 500 MCM (both front & back)
temperature of the conductor for supply maximum
permissible
75 °C
material of the conductor for supply
AL or CU
type of electrical connection for load-side outgoing feeder
Box lug
tightening torque [lbf·in] for load-side outgoing feeder
180 ... 195 lbf·in
type of connectable conductor cross-sections at AWG
cables for load-side outgoing feeder single or multistranded
3/0 ... 600 kcmil (front only) or 250 ... 500 kcmil (back only) or 2x 500
kcmil (both front & back) AWG
US2:73CS35BFA
Page 2/3
1.21.2021
Subject to change without notice
© Copyright Siemens
temperature of the conductor for load-side outgoing feeder
maximum permissible
75 °C
material of the conductor for load-side outgoing feeder
CU
type of electrical connection for auxiliary and control circuit
screw-type terminals
tightening torque [lbf·in] for auxiliary and control contacts
with screw-type terminals
7 ... 10 lbf·in
temperature of the conductor for auxiliary and control
contacts maximum permissible
75 °C
material of the conductor for auxiliary and control contacts
CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the
main circuit required
10kA@600V (Class H or K); 100kA@600V (Class R or J)
design of the short-circuit trip
Thermal magnetic circuit breaker
breaking capacity maximum short-circuit current (Icu)
● at 240 V
50 kA
● at 480 V
50 kA
● at 600 V
50 kA
certificate of suitability
NEMA ICS 2; UL 508A
Further information
Industrial Controls - Product Overview (Catalogs, Brochures,…)
www.usa.siemens.com/iccatalog
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:73CS35BFA
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/US/en/ps/US2:73CS35BFA
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:73CS35BFA&lang=en
Certificates/approvals
https://support.industry.siemens.com/cs/US/en/ps/US2:73CS35BFA/certificate
US2:73CS35BFA
Page 3/4
1.21.2021
Subject to change without notice
© Copyright Siemens
US2:73CS35BFA
Page 4/5
1.21.2021
Subject to change without notice
© Copyright Siemens
last modified:
US2:73CS35BFA
Page 5/5
3/19/2020
1.21.2021
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“73CS35BFA”相匹配的价格&库存,您可以联系我们找货
免费人工找货