0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A6X30074045

A6X30074045

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    MSP S0 11-16A SCREW 12PCS

  • 数据手册
  • 价格&库存
A6X30074045 数据手册
Data sheet 3RV2021-4AA10-Z W97 Circuit breaker size S0 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A screw terminal Standard switching capacity Multi-unit packaging Pack = 12 units product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data size of the circuit-breaker S0 size of contactor can be combined company-specific S00, S0 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 9.25 W ● at AC in hot operating state per pole 3.1 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV maximum permissible voltage for safe isolation in networks with grounded star point ● between main and auxiliary circuit 400 V ● between main and auxiliary circuit 400 V shock resistance acc. to IEC 60068-2-27 25g / 11 ms mechanical service life (switching cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 electrical endurance (switching cycles) typical 100 000 type of protection according to ATEX directive 2014/34/EU Ex II (2) GD certificate of suitability according to ATEX directive 2014/34/EU DMT 02 ATEX F 001 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -20 ... +60 °C ● ambient temperature during storage -50 ... +80 °C ● ambient temperature during transport -50 ... +80 °C temperature compensation -20 ... +60 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3RV20214AA10-Z W97 Page 1/2 3 1.30.2021 Subject to change without notice © Copyright Siemens adjustable current response value current of the current-dependent overload release 10 ... 16 A ● operating voltage rated value 690 V ● operating voltage at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 16 A operational current at AC-3 at 400 V rated value 16 A operating power at AC-3 ● at 230 V rated value 4 000 W ● at 400 V rated value 7 500 W ● at 500 V rated value 7 500 W ● at 690 V rated value 11 000 W operating frequency at AC-3 maximum 15 1/h Auxiliary circuit number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of CO contacts for auxiliary contacts 0 Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal breaking capacity operating short-circuit current (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 25 kA ● at 500 V rated value 5 kA ● at 690 V rated value 2 kA breaking capacity maximum short-circuit current (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 55 kA ● at AC at 500 V rated value 10 kA ● at AC at 690 V rated value 4 kA response value current of instantaneous short-circuit trip unit 208 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 16 A ● at 600 V rated value 16 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 1 hp — at 230 V rated value 2 hp ● for 3-phase AC motor — at 200/208 V rated value 3 hp — at 220/230 V rated value 5 hp — at 460/480 V rated value 10 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link for IT network for short-circuit protection of the main circuit ● at 400 V gL/gG 63 A ● at 500 V gL/gG 50 A ● at 690 V gL/gG 40 A Installation/ mounting/ dimensions mounting position 3RV20214AA10-Z W97 Page 2/3 any 1.30.2021 Subject to change without notice © Copyright Siemens fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 height 97 mm width 45 mm depth 97 mm required spacing ● for grounded parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm ● for live parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm Connections/ Terminals product function removable terminal for auxiliary and control circuit No type of electrical connection ● for main current circuit arrangement of electrical connectors for main current circuit screw-type terminals Top and bottom type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² ● at AWG cables for main contacts 2x (16 ... 12), 2x (14 ... 8) ● tightening torque for main contacts with screw-type terminals 2 ... 2.5 N·m design of screwdriver shaft Diameter 5 to 6 mm size of the screwdriver tip Pozidriv 2 design of the thread of the connection screw ● for main contacts M4 Safety related data B10 value ● with high demand rate acc. to SN 31920 5 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 50 % ● with high demand rate acc. to SN 31920 50 % failure rate [FIT] 3RV20214AA10-Z W97 Page 3/4 1.30.2021 Subject to change without notice © Copyright Siemens ● with low demand rate acc. to SN 31920 50 FIT T1 value for proof test interval or service life acc. to IEC 61508 10 y protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front display version for switching status Handle Certificates/ approvals Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-4AA10-Z W97 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-4AA10-Z W97 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-4AA10-Z W97 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-4AA10-Z W97&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-4AA10-Z W97/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2021-4AA10-Z W97&objecttype=14&gridview=view1 3RV20214AA10-Z W97 Page 4/5 1.30.2021 Subject to change without notice © Copyright Siemens 3RV20214AA10-Z W97 Page 5/6 1.30.2021 Subject to change without notice © Copyright Siemens last modified: 3RV20214AA10-Z W97 Page 6/6 12/15/2020 1.30.2021 Subject to change without notice © Copyright Siemens
A6X30074045 价格&库存

很抱歉,暂时无法提供与“A6X30074045”相匹配的价格&库存,您可以联系我们找货

免费人工找货