0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CLM2C08120

CLM2C08120

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR LTG M-HELD,30A,8NO,N12

  • 数据手册
  • 价格&库存
CLM2C08120 数据手册
Data sheet US2:CLM2C08120 Mechanically held lighting contactor, Contactor amp rating 30Amp 0NC _ 8NO poles, 110VAC 50HZ/120VAC 60HZ coil, Non-combination type, Enclosure NEMA type 12, Dust/drip proof for indoors product brand name Class CLM design of the product Magnetically latched lighting contactor special product feature Energy efficient; Quiet operation General technical data weight [lb] Height x Width x Depth [in] 20 lb touch protection against electrical shock NA for enclosed products installation altitude [ft] at height above sea level maximum 6560 ft country of origin USA 16 × 13 × 6 in Contactor size of contactor 30 Amp number of NO contacts for main contacts 8 number of NC contacts for main contacts 0 operating voltage for main current circuit at AC at 60 Hz maximum 600 V mechanical service life (switching cycles) of the main contacts typical 10000000 contact rating of the main contacts of lighting contactor ● at tungsten (1 pole per 1 phase) rated value 30A @277V 1p 1ph ● at tungsten (2 poles per 1 phase) rated value 30A @480V 2p 1ph ● at tungsten (3 poles per 3 phases) rated value 30A @480V 3p 3ph ● at ballast (1 pole per 1 phase) rated value 30A @347V 1p 1ph ● at ballast (2 poles per 1 phase) rated value 30A @600V 2p 1ph ● at ballast (3 poles per 3 phases) rated value 30A @600V 3p 3ph ● at resistive load (1 pole per 1 phase) rated value 30A @347V 1p 1ph ● at resistive load (2 poles per 1 phase) rated value 30A @600V 2p 1ph ● at resistive load (3 poles per 3 phases) rated value 30A @600V 3p 3ph Auxiliary contact number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of total auxiliary contacts maximum 4 contact rating of auxiliary contacts of contactor according to UL NA Coil type of voltage of the control supply voltage AC control supply voltage ● at AC at 50 Hz rated value US2:CLM2C08120 Page 1/2 110 V 12.21.2020 Subject to change without notice © Copyright Siemens ● at AC at 60 Hz rated value 120 V apparent pick-up power of magnet coil at AC 820 V·A apparent holding power of magnet coil at AC 80 V·A operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 Enclosure degree of protection NEMA rating of the enclosure NEMA 12 enclosure design of the housing Dust tight and drip proof for indoors Mounting/wiring mounting position Vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Screw-type terminals tightening torque [lbf·in] for supply 18 ... 20 lbf·in type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 2x (14 ... 8 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply CU type of electrical connection for load-side outgoing feeder Screw-type terminals tightening torque [lbf·in] for load-side outgoing feeder 18 ... 20 lbf·in type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 2x (14 ... 8 AWG) temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 8 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU Short-circuit current rating design of the fuse link for short-circuit protection of the main circuit required none design of the short-circuit trip Thermal magnetic circuit breaker breaking capacity maximum short-circuit current (Icu) ● at 240 V 5 kA ● at 480 V 5 kA ● at 600 V 5 kA certificate of suitability NEMA ICS 2; UL 508A Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:CLM2C08120 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:CLM2C08120 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:CLM2C08120&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:CLM2C08120/certificate US2:CLM2C08120 Page 2/3 12.21.2020 Subject to change without notice © Copyright Siemens US2:CLM2C08120 Page 3/4 12.21.2020 Subject to change without notice © Copyright Siemens last modified: US2:CLM2C08120 Page 4/4 3/10/2020 12.21.2020 Subject to change without notice © Copyright Siemens
CLM2C08120 价格&库存

很抱歉,暂时无法提供与“CLM2C08120”相匹配的价格&库存,您可以联系我们找货

免费人工找货