CLM32061

CLM32061

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR,LIGHTING,20A,3-POLE,OP

  • 数据手册
  • 价格&库存
CLM32061 数据手册
Data sheet US2:CLM32061 Mechanically held lighting contactor, Contactor amp rating 20A, 0 N.C. / 3 N.O. poles, Non-combination type, Enclosure NEMA type (open), No enclosure product brand name Class CLM design of the product Mechanically held lighting contactor special product feature Energy efficient; Quiet operation General technical data weight [lb] 2 lb Height x Width x Depth [in] 7.3 × 4.3 × 3.5 in touch protection against electrical shock Not finger-safe installation altitude [ft] at height above sea level maximum 6560 ft country of origin Mexico Contactor size of contactor 20 Amp number of NO contacts for main contacts 3 number of NC contacts for main contacts 0 operating voltage for main current circuit at AC at 60 Hz maximum 600 V contact rating of the main contacts of lighting contactor ● at tungsten (1 pole per 1 phase) rated value 20A @250V 1p 1ph ● at tungsten (2 poles per 1 phase) rated value 20A @250V 2p 1ph ● at tungsten (3 poles per 3 phases) rated value 20A @250V 3p 3ph ● at ballast (1 pole per 1 phase) rated value 20A @347V 1p 1ph ● at ballast (2 poles per 1 phase) rated value 20A @600V 2p 1ph ● at ballast (3 poles per 3 phases) rated value 20A @600V 3p 3ph ● at resistive load (1 pole per 1 phase) rated value 30A @347V 1p 1ph ● at resistive load (2 poles per 1 phase) rated value 30A @600V 2p 1ph ● at resistive load (3 poles per 3 phases) rated value 30A @600V 3p 3ph Auxiliary contact number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of total auxiliary contacts maximum 4 contact rating of auxiliary contacts of contactor according to UL NA Coil type of voltage of the control supply voltage AC control supply voltage ● at AC at 50 Hz rated value 208 ... 240 V ● at AC at 60 Hz rated value 208 ... 240 V apparent pick-up power of magnet coil at AC 600 VA apparent holding power of magnet coil at AC 6 VA operating range factor control supply voltage rated value 0.85 ... 1.1 US2:CLM32061 Page 1/3 7/7/2022 Subject to change without notice © Copyright Siemens of magnet coil Enclosure degree of protection NEMA rating of the enclosure Open device (no enclosure) design of the housing NA Mounting/wiring mounting position Vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Screw-type terminals tightening torque [lbf·in] for supply 18 ... 18 lbf·in type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 2x (18 ... 10 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply CU type of electrical connection for load-side outgoing feeder Screw-type terminals tightening torque [lbf·in] for load-side outgoing feeder 18 ... 18 lbf·in type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 2x (18 ... 10 AWG) temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 18 ... 18 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (18 ... 10 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU Short-circuit current rating design of the fuse link for short-circuit protection of the main circuit required none design of the short-circuit trip Thermal magnetic circuit breaker breaking capacity maximum short-circuit current (Icu) ● at 240 V 5 kA ● at 480 V 5 kA ● at 600 V 5 kA certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No. 14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:CLM32061 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:CLM32061 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:CLM32061&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:CLM32061/certificate US2:CLM32061 Page 2/3 7/7/2022 Subject to change without notice © Copyright Siemens LOAD LINE 1 AUX. CONTACT WHEN USED REFERENCE NUMBER DENOTE POLE LOCATION (REFER TO CHART) 6 CONTROL SOURCE NOTE: 1. CONTROL FUSING ACCORDING TO NEC 430-72 AND 450-3. L1/1 L1/1 L2 L2 DUAL PRIMARY SINGLE PRIMARY L1/1 DUAL PRIMARY L2 OPTIONAL LINE CONTROL FUSING OR SEPARATE SOURCE 1 L BLACK N.O COIL L O H3 H4 H2 H1 460V H3 H4 H1 H4 ---V H1 X1 X2 X1 X2 1 X2 X1 X2 1 X2 X1 1 115V 1 1 2 3 4 5 O C REMOTE CONTROL MODULE WHEN USED SEE FIG. B,C & D ON CONTROL MODULE VOLTAGE MODULE TERMINAL 0 LINE LOAD CONNECTIONS TO CONTROL MODULES COMMON OR SEPARATE CONTROL LINES ON OFF FIG. A TYPICAL OFF-ON SELECTOR SWITCH 5 2 C 3 ORANGE N.C 7 OFF AUTO 5 MODULE CONTROL VOLTAGE * 5 CONTACTOR CONTROL VOLTAGE " " CONTACTOR TERMINAL O ON " " CONTACTOR TERMINAL C ON L CR CR 0 CR C 4 REMOTE CONTROL COIL ON 2 WIRE CONTROL ACC. 47 LINE LOAD 4 3 CONTROL MODULE VOLTAGE 12 CONT. STATION FOR ACC. 47,48 & 49 * FOR 24 VDC CONTROL MODULES CONNECT TERMINAL 4 TO NEGATIVE (-) OFF HAND 1 BROWN CONT. STATION FOR ACC. 48 & 49 3 C L NOT USED 2 O CONTACTOR CONTROL VOLTAGE CONTROL MODULE VOLTAGE O C CONTACTOR CONTROL VOLTAGE 4 O 5 L L CONNECT TO: 1 6 COIL X2 X2 OFF C BLACK N.O ---V L REMOTE CONTROL MODULE WHEN USED SEE FIG. B,C & D 1 115V 12 FIG. 1 2-6 POLES AUX. CONTACT WHEN USED L2 SEPARATE CONTROL SUPPLY 5 BROWN 7 L1/1 CONTACTOR CONTROL VOLTAGE C ORANGE N.C H2 230V CONTACTOR CONTROL VOLTAGE FIG. 2 8-12 POLES L OFF 5 L ON-OFF CONTACT POLE LOCATION CHART POLES AUXILIARY CONTACT RATING ACC. CLM4097291 (1PDT) ACC. CLM4097292 (2PDT) LOCATION 2 2&5 3 2, 3 & 5 4 2, 3, 4 & 5 6 1-6 8 1 - 6, 8 & 11 10 1 - 6, 8, 9, 10 & 11 12 1 - 12 CR 0 CR C 3 CONTROL MODULE VOLTAGE CR 4 10A, 1/3 HP 277 VAC 0.5A, 125VDC 0.25A, 250VDC ON 2 WIRE CONTROL ACC. 47 FIG. B L CONTACTOR CONTROL VOLTAGE MAIN CONTACT MAXIMUM VOLTAGE RATINGS OPEN OR CLOSED 2 FOR 1 AMPERE CONTINUOUS CONTROL MODULE VOLTAGE ON 3 FOR 3 2 CR1 250 AC 20 TUNGSTEN 277 AC 480 AC 20 BALLAST 347 AC 600 AC 30 GENERAL GENERAL NOTES 3 CR2 L CR2 CR1 0 CR1 CR2 C 4 250 AC OFF 5 OFF POLES TO LOAD 1 FOR 1 COIL ON COIL B. MAIN CONTACTS ARE SHOWN IN OPEN POSITION WITH CONTROL LINE DE-ENERGIZED. SEE RATINGS BELOW. (SWITCH SHIPPED WITH CONTACTS CLOSED) PILOT LIGHTS REQUIRE (1) EA. CLM4097291 AUXILIARY CONTACT KIT. 3 WIRE CONTROL ACC. 48 FIG. C A. WHEN CONTACTOR & LINE VOLTAGE ARE THE SAME, THE CONTACTOR CONTROL VOLTAGE CAN BE DERIVED FROM THE LINE POLES OF THE CONTACTOR SWITCH. C. LINE & LOAD TERMINALS ARE REVERSIBLE. D. CONTACTS ARE SINGLE THROW, DOUBLE BREAK, WITH MOMENTARILY ENERGIZED SINGLE COIL OPERATOR MECHANICALLY HELD IN BOTH OPEN & CLOSED PORITIONS. 20 AMP. DC GENERAL 125V DC MAX. 2 POLES IN SERIES 250V DC MAX. 3 POLES IN SERIES SWITCH IS SUITABLE FOR USE IN A CIRCUIT CAPABLE OF DELIVERING NOT MORE THAN THE RMS SYMMETERICAL CURRENT AT THE MAXIMUM VOLTAGE SHOWN BELOW, WHEN PROTECTED BY A 30 AMP CIRCUIT BREAKER HAVING AN INTERRUPTING RATING OF NOT LESS THAN VALUES SHOWN. MAXIMUM RMS E. CUSTOMER CONNECTIONS TO LINE & LOAD WILL ACCEPT NO. 18AWG TO 10AWG COPPER WIRE. TORQUE LINE POLE CONNECTION TO 18 in. lb. ON CONTACTOR CONTROL VOLTAGE L OFF 3 OFF 5 CR2 CONTROL MODULE VOLTAGE 2 CR1 CR2 L CR1 0 CR1 C F. CUSTOMER CONNECTIONS TO ELECTRONIC MODULE (ACC. 47, 48, OR 49) WILL ACCEPT NO. 22AWG TO 12AWG COPPER WIRE. TORQUE CONTROL TERMINALS TO 12 in. lb. G. CONTROL MODULE VOLTAGE SUPPLIED BY CUSTOMER. COIL 4 MAXIMUM AC AMPERES VOLTS 22,000 250 14,000 480 10,000 600 ON ON-OFF (FORM 3) CONTROL ACC. 49 FIG. D 24306100401 last modified: US2:CLM32061 Page 3/3 4/27/2021 7/7/2022 Subject to change without notice © Copyright Siemens
CLM32061 价格&库存

很抱歉,暂时无法提供与“CLM32061”相匹配的价格&库存,您可以联系我们找货

免费人工找货