Data sheet
US2:CLM32061
Mechanically held lighting contactor, Contactor amp rating 20A, 0 N.C. / 3
N.O. poles, Non-combination type, Enclosure NEMA type (open), No
enclosure
product brand name
Class CLM
design of the product
Mechanically held lighting contactor
special product feature
Energy efficient; Quiet operation
General technical data
weight [lb]
2 lb
Height x Width x Depth [in]
7.3 × 4.3 × 3.5 in
touch protection against electrical shock
Not finger-safe
installation altitude [ft] at height above sea level maximum
6560 ft
country of origin
Mexico
Contactor
size of contactor
20 Amp
number of NO contacts for main contacts
3
number of NC contacts for main contacts
0
operating voltage for main current circuit at AC at 60 Hz
maximum
600 V
contact rating of the main contacts of lighting contactor
● at tungsten (1 pole per 1 phase) rated value
20A @250V 1p 1ph
● at tungsten (2 poles per 1 phase) rated value
20A @250V 2p 1ph
● at tungsten (3 poles per 3 phases) rated value
20A @250V 3p 3ph
● at ballast (1 pole per 1 phase) rated value
20A @347V 1p 1ph
● at ballast (2 poles per 1 phase) rated value
20A @600V 2p 1ph
● at ballast (3 poles per 3 phases) rated value
20A @600V 3p 3ph
● at resistive load (1 pole per 1 phase) rated value
30A @347V 1p 1ph
● at resistive load (2 poles per 1 phase) rated value
30A @600V 2p 1ph
● at resistive load (3 poles per 3 phases) rated value
30A @600V 3p 3ph
Auxiliary contact
number of NC contacts for auxiliary contacts
0
number of NO contacts for auxiliary contacts
0
number of total auxiliary contacts maximum
4
contact rating of auxiliary contacts of contactor according
to UL
NA
Coil
type of voltage of the control supply voltage
AC
control supply voltage
● at AC at 50 Hz rated value
208 ... 240 V
● at AC at 60 Hz rated value
208 ... 240 V
apparent pick-up power of magnet coil at AC
600 VA
apparent holding power of magnet coil at AC
6 VA
operating range factor control supply voltage rated value
0.85 ... 1.1
US2:CLM32061
Page 1/3
7/7/2022
Subject to change without notice
© Copyright Siemens
of magnet coil
Enclosure
degree of protection NEMA rating of the enclosure
Open device (no enclosure)
design of the housing
NA
Mounting/wiring
mounting position
Vertical
fastening method
Surface mounting and installation
type of electrical connection for supply voltage line-side
Screw-type terminals
tightening torque [lbf·in] for supply
18 ... 18 lbf·in
type of connectable conductor cross-sections at line-side
at AWG cables single or multi-stranded
2x (18 ... 10 AWG)
temperature of the conductor for supply maximum
permissible
75 °C
material of the conductor for supply
CU
type of electrical connection for load-side outgoing feeder
Screw-type terminals
tightening torque [lbf·in] for load-side outgoing feeder
18 ... 18 lbf·in
type of connectable conductor cross-sections at AWG
cables for load-side outgoing feeder single or multistranded
2x (18 ... 10 AWG)
temperature of the conductor for load-side outgoing feeder
maximum permissible
75 °C
material of the conductor for load-side outgoing feeder
CU
type of electrical connection of magnet coil
Screw-type terminals
tightening torque [lbf·in] at magnet coil
18 ... 18 lbf·in
type of connectable conductor cross-sections of magnet
coil at AWG cables single or multi-stranded
2x (18 ... 10 AWG)
temperature of the conductor at magnet coil maximum
permissible
75 °C
material of the conductor at magnet coil
CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the
main circuit required
none
design of the short-circuit trip
Thermal magnetic circuit breaker
breaking capacity maximum short-circuit current (Icu)
● at 240 V
5 kA
● at 480 V
5 kA
● at 600 V
5 kA
certificate of suitability
NEMA ICS 2; UL 508; CSA 22.2, No. 14
Further information
Industrial Controls - Product Overview (Catalogs, Brochures,…)
www.usa.siemens.com/iccatalog
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:CLM32061
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/US/en/ps/US2:CLM32061
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:CLM32061&lang=en
Certificates/approvals
https://support.industry.siemens.com/cs/US/en/ps/US2:CLM32061/certificate
US2:CLM32061
Page 2/3
7/7/2022
Subject to change without notice
© Copyright Siemens
LOAD
LINE
1
AUX. CONTACT
WHEN USED
REFERENCE NUMBER
DENOTE POLE
LOCATION
(REFER TO CHART)
6
CONTROL SOURCE
NOTE: 1. CONTROL FUSING ACCORDING TO NEC 430-72 AND 450-3.
L1/1
L1/1
L2
L2
DUAL PRIMARY
SINGLE PRIMARY
L1/1
DUAL PRIMARY
L2
OPTIONAL LINE CONTROL FUSING
OR
SEPARATE SOURCE
1
L
BLACK N.O
COIL
L
O
H3
H4
H2
H1
460V
H3
H4
H1
H4
---V
H1
X1
X2
X1
X2
1
X2
X1
X2
1
X2
X1
1
115V
1
1 2 3 4 5 O C
REMOTE CONTROL MODULE
WHEN USED SEE FIG. B,C & D
ON
CONTROL
MODULE
VOLTAGE
MODULE
TERMINAL
0
LINE
LOAD
CONNECTIONS TO CONTROL MODULES
COMMON OR SEPARATE
CONTROL LINES
ON
OFF
FIG. A
TYPICAL OFF-ON
SELECTOR SWITCH
5
2
C
3
ORANGE N.C
7
OFF
AUTO
5
MODULE CONTROL VOLTAGE *
5
CONTACTOR CONTROL VOLTAGE
" " CONTACTOR
TERMINAL O ON
" " CONTACTOR
TERMINAL C ON
L
CR
CR
0
CR
C
4
REMOTE
CONTROL
COIL
ON
2 WIRE CONTROL ACC. 47
LINE
LOAD
4
3
CONTROL
MODULE
VOLTAGE
12
CONT. STATION FOR ACC. 47,48 & 49
* FOR 24 VDC CONTROL MODULES
CONNECT TERMINAL 4 TO NEGATIVE (-)
OFF
HAND
1
BROWN
CONT. STATION FOR ACC. 48 & 49
3
C
L
NOT USED
2
O
CONTACTOR CONTROL
VOLTAGE
CONTROL
MODULE
VOLTAGE
O C
CONTACTOR
CONTROL VOLTAGE
4
O
5
L
L
CONNECT TO:
1
6
COIL
X2
X2
OFF
C
BLACK N.O
---V
L
REMOTE CONTROL MODULE
WHEN USED SEE FIG. B,C & D
1
115V
12
FIG. 1
2-6 POLES
AUX. CONTACT
WHEN USED
L2
SEPARATE
CONTROL
SUPPLY
5
BROWN
7
L1/1
CONTACTOR
CONTROL VOLTAGE
C
ORANGE N.C
H2 230V
CONTACTOR CONTROL
VOLTAGE
FIG. 2
8-12 POLES
L
OFF
5
L
ON-OFF
CONTACT POLE LOCATION CHART
POLES
AUXILIARY CONTACT RATING
ACC. CLM4097291 (1PDT)
ACC. CLM4097292 (2PDT)
LOCATION
2
2&5
3
2, 3 & 5
4
2, 3, 4 & 5
6
1-6
8
1 - 6, 8 & 11
10
1 - 6, 8, 9, 10 & 11
12
1 - 12
CR
0
CR
C
3
CONTROL
MODULE
VOLTAGE
CR
4
10A, 1/3 HP
277 VAC
0.5A, 125VDC
0.25A, 250VDC
ON
2 WIRE CONTROL ACC. 47
FIG. B
L
CONTACTOR CONTROL
VOLTAGE
MAIN CONTACT MAXIMUM VOLTAGE
RATINGS OPEN OR CLOSED
2 FOR 1
AMPERE
CONTINUOUS
CONTROL
MODULE
VOLTAGE
ON
3 FOR 3
2
CR1
250 AC
20
TUNGSTEN
277 AC
480 AC
20
BALLAST
347 AC
600 AC
30
GENERAL
GENERAL NOTES
3
CR2
L
CR2
CR1
0
CR1
CR2
C
4
250 AC
OFF
5
OFF
POLES TO LOAD
1 FOR 1
COIL
ON
COIL
B. MAIN CONTACTS ARE SHOWN IN OPEN POSITION WITH
CONTROL LINE DE-ENERGIZED. SEE RATINGS BELOW.
(SWITCH SHIPPED WITH CONTACTS CLOSED)
PILOT LIGHTS
REQUIRE (1) EA.
CLM4097291
AUXILIARY
CONTACT KIT.
3 WIRE CONTROL ACC. 48
FIG. C
A. WHEN CONTACTOR & LINE VOLTAGE ARE THE SAME,
THE CONTACTOR CONTROL VOLTAGE CAN BE DERIVED
FROM THE LINE POLES OF THE CONTACTOR SWITCH.
C. LINE & LOAD TERMINALS ARE REVERSIBLE.
D. CONTACTS ARE SINGLE THROW, DOUBLE BREAK, WITH
MOMENTARILY ENERGIZED SINGLE COIL OPERATOR
MECHANICALLY HELD IN BOTH OPEN & CLOSED PORITIONS.
20 AMP. DC
GENERAL
125V DC MAX. 2 POLES IN SERIES
250V DC MAX. 3 POLES IN SERIES
SWITCH IS SUITABLE FOR USE IN A CIRCUIT
CAPABLE OF DELIVERING NOT MORE THAN THE
RMS SYMMETERICAL CURRENT AT THE MAXIMUM
VOLTAGE SHOWN BELOW, WHEN PROTECTED BY
A 30 AMP CIRCUIT BREAKER HAVING AN
INTERRUPTING RATING OF NOT LESS THAN
VALUES SHOWN.
MAXIMUM RMS
E. CUSTOMER CONNECTIONS TO LINE & LOAD WILL ACCEPT
NO. 18AWG TO 10AWG COPPER WIRE. TORQUE LINE
POLE CONNECTION TO 18 in. lb.
ON
CONTACTOR CONTROL
VOLTAGE
L
OFF
3
OFF
5
CR2
CONTROL
MODULE
VOLTAGE
2
CR1
CR2
L
CR1
0
CR1
C
F. CUSTOMER CONNECTIONS TO ELECTRONIC MODULE (ACC.
47, 48, OR 49) WILL ACCEPT NO. 22AWG TO 12AWG
COPPER WIRE. TORQUE CONTROL TERMINALS TO 12 in. lb.
G. CONTROL MODULE VOLTAGE SUPPLIED BY CUSTOMER.
COIL
4
MAXIMUM AC
AMPERES
VOLTS
22,000
250
14,000
480
10,000
600
ON
ON-OFF (FORM 3) CONTROL
ACC. 49
FIG. D
24306100401
last modified:
US2:CLM32061
Page 3/3
4/27/2021
7/7/2022
Subject to change without notice
© Copyright Siemens