0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BIOMETRIC-EXP-EVB

BIOMETRIC-EXP-EVB

  • 厂商:

    SILABS(芯科科技)

  • 封装:

    -

  • 描述:

    EVAL BOARD BIOMETRIC

  • 数据手册
  • 价格&库存
BIOMETRIC-EXP-EVB 数据手册
Biometric-EXP EVB es ig ns B I O ME T R I C -EXP Evaluation Board U SER ’ S G UIDE 1. Introduction m en de d fo r N ew D The Silicon Labs’ Biometric-EXP Evaluation Board is a hardware plugin card for EFM32™ Starter Kits (STK’s). The Biometric-EXP is intended to demonstrate and evaluate the biometric applications of Silicon Labs Si7013 Humidity and Temperature Sensor and the Si1146 Proximity/UV/Ambient Light Sensor which is capable of monitoring pulse rate and oxygen saturation (SpO2). A Biometric-EXP Software Demo is available to download to an EFM32 Wonder Gecko STK through Simplicity Studio. The software is capable of displaying humidity, temperature, UV, pulse rate, and SpO2 readings on the Wonder Gecko STK display. In addition to the Silicon Labs sensors, it is also notable that the Biometric-EXP EVB contains a Silicon Labs’ TS3310 Boost DC-DC Converter. Figure 1. EFM32 Wonder Gecko STK (Left) Connected to a Biometric-EXP (Right) 1.1. Key Features Si7013 Humidity and Temperature Sensor Proximity/UV/Ambient Light Sensor capable of monitoring Pulse Rate and SpO2 6-pin ribbon cable connector for attaching a postage stamp board 20-pin expansion header Battery operated with low power optimizations for long battery life Demonstration software source code available USB debug mode allowing HRM and SpO2 samples to be transferred to a PC Windows GUI to visualize pulse signals and to record samples from USB debug mode Easy use through Simplicity Studio ec om Si1146 1.2. Getting Started R The first step to getting started with your new Biometric-EXP-EVB is to download Simplicity Studio from www.silabs.com/simplicity-studio. N ot The simplicity studio software package contains all the tools, drivers, software examples, and documentation needed to use the Biometric-EXP-EVB. You will need to connect the Biometric-EXP-EVB to the EFM32WG-STK3800 Wonder Gecko STK or the EFM32GG-STK3700 Giant Gecko STK. The demo code can be loaded using the USB cable and the J-Link debug interface. Rev. 0.4 12/15 Copyright © 2015 by Silicon Laboratories Biometric-EXP EVB Biometric-EXP EVB 2. Loading the Demo Onto the Gecko Starter Kit The following steps will load the demo firmware onto the Gecko STK. This process requires Simplicity Studio which is available for download at www.silabs.com/simplicity-studio. es ig ns 1. Use a USB mini type cable to connect the J-Link debug interface on the Gecko STK to the PC and set the 3-position Power Source Select switch to DBG (right-most position). om m en de d fo r N ew D 2. Launch Simplicity Studio. Figure 2. Simplicity Studio 3. Click on Refresh Detected Hardware. 4. Select the Gecko STK device, under Detected Hardware. N ot R ec 5. Click on the Demos button on the top right of Simplicity Studio. 2 Rev. 0.4 Biometric-EXP EVB Figure 3. Demo Selection Dialog N ot R ec om m en de d fo r N ew D es ig ns 6. Select the Biometric-EXP demo from the list and click Start. Rev. 0.4 3 Biometric-EXP EVB 3. Running the Demo A Silicon Labs EFM32 Wonder Gecko Starter Kit (EFM32WG-STK3800) and a Silicon Labs Biometric-EXP (see Figure 1) is needed to run the Biometric EXP Demo. es ig ns The Biometric-EXP demo application uses the Wonder-Gecko STK’s LCD to display sensor output and the two push buttons, PB0 and PB1, to cycle through the modes of the demo. The full operation including startup is illustrated in Figures 4 and 5. 3.1. Demo Startup D Upon reset, the demo will first check whether PB0 is pressed then store the result. It will then search for a supported device on the 6-pin ribbon cable connector. If a Si1143-M01-PS or Si1147-M01-PS is detected, the demo will automatically use that device for HRM measurements. In this case, the Si1146 sensor onboard the Biometric-EXP will not be utilized. SpO2 is not available with the Si114x-M01-PS EVB's. If a HRM-GGG-PS EVB is detected, the demo will display ‘Error’. The Biometric-EXP demo does not support wrist-based heart rate monitoring. Please contact Silicon Labs to inquire about our wrist-based heart rate monitor solutions. N ot R ec om m en de d fo r N ew Following the search for a ribbon cable device, the demo will check the stored value of PB0 to enable or disable the USB debug mode accordingly and display an USB On or USB Off message for one second. Refer to Section “4. USB Debug Mode” for details on USB debug mode. Lastly, the demo will display version information then start the demo in Heart Rate Monitor mode. 4 Rev. 0.4 Biometric-EXP EVB es ig ns 5HVHW 86%21 86%2)) fo r 'LVSOD\HGIRUV m en de d 'LVSOD\HGIRUV 1RW3UHVVHG 3%3UHVVHG" N ew 3UHVVHG D ,&5LEERQ&DEOH 'HYLFH'HWHFWLRQ 'HPR9HUVLRQ +509HUVLRQ (Displayed for 1 s) 6WDUW+HDUW5DWH0RQLWRU'HPR0RGH R ec om (Displayed for 1 s) N ot Figure 4. Biometric-EXP Demo Startup Sequence Flash Programmer Dialog Rev. 0.4 5 Biometric-EXP EVB 6S2 0RQLWRU 6L 8VH3%DQG3% WRF\FOHWKURXJK PRGHVRIWKHGHPR 7HPSHUDWXUH 6HQVRUƒ) 6L  7HPSHUDWXUH 6HQVRUƒ& 6L N ew +XPLGLW\ 6HQVRU 6L D 8OWUDYLROHW 6HQVRU 6L  es ig ns HeartRate Monitor (^i1146) Figure 5. Biometric-EXP Demo Modes 3.2. Heart Rate Monitor Mode fo r *Note: SpO2 Monitor mode is not available when using Si1143-M01-PS or Si1147-M01-PS. m en de d When heart rate monitor demo is idle, the LCD will show the word “Pulse” followed by a message instructing the user to place his/her finger on the optical sensor. In idle mode, the sensor is not continuously sampling. Rather, it executes one sample every two seconds by performing a forced measurement. That sample is then analyzed to determine if there is skin contact with the sensor. Only when the application detects skin contact does it begin sampling continuously and running the HRM algorithm. It will remain in run mode (continuous sampling) until skin contact is removed for greater than two seconds. This approach significantly reduces power usage when idle. When the application is acquiring the heart rate, it will display the word “Wait” on the LCD. It typically takes five to seven seconds to acquire a valid heart rate. Once a valid heart rate is measured, the display will show the heart rate. If the heart rate is not displayed within seven seconds, it is likely that the algorithm cannot get a valid pulse rate. When this occurs, the user should remove his/her finger and try it again adjusting the position of the finger and the finger pressure as needed. N ot R ec om Proper finger position in relation to the sensor and LEDs as well as proper finger pressure is essential for accurate measurements. The finger should fully cover both LEDs and the sensor. As illustrated in Figure 6, the finger should be lightly placed on the sensor. Too much pressure will restrict blood flow in the finger and, therefore, not allow the sensor to measure a heart rate. Figure 6. Proper Finger Placement 6 Rev. 0.4 Biometric-EXP EVB 3.3. SpO2 Monitor Mode es ig ns When SpO2 mode is active, the LCD will show “SpO2” followed by a message instructing the user to place his/her finger on the optical sensor. Beyond that, SpO2 monitor mode mirrors the operation of the Heart Rate Monitor mode as described in Section “3.2. Heart Rate Monitor Mode” . Please note that SpO2 mode is not available when using Si1143-M01-PS or Si1147-M01-PS devices via the 6-pin ribbon cable. Even more so than HRM, proper finger position and pressure is important to achieve a good SpO2 measurement. Refer to Figure 6 for an illustration of proper finger position. 3.4. Ultraviolet Sensor Mode When the UV sensor mode is active, the LCD will show “UV” followed by the measured UV index. In this mode, the UV reading is updated every two seconds. D 3.5. Temperature Sensor Mode In the temperature sensor modes, the LCD will show the temperature in Fahrenheit or Celsius as indicated by an “F” or a “C” following the reading. In this mode the temperature reading is updated every two seconds. N ew 3.6. Relative Humidity Sensor Mode N ot R ec om m en de d fo r In the relative humidity sensor mode, the LCD will show “RH” followed by the relative humidity reading. In this modem, the relative humidity reading is updated every two seconds. Rev. 0.4 7 Biometric-EXP EVB 4. USB Debug Mode es ig ns The Biometric-EXP demo firmware includes a debug mode that enables Heart Rate Monitor and SpO2 raw samples from the sensor to be streamed to a host PC via the Gecko STK’s USB interface. Only HRM and SpO2 data is available via the USB debug interface. UV, Relative Humidity, and Temperature data is not available. Enabling and connecting to USB debug mode is illustrated in Figure 7 and is described in the following sections. The J-Link USB mini connector is not used for the Biometric-EXP demo debug interface. It is  only used to load firmware and for firmware development m en de d fo r N ew D To enable USB Debug Mode, hold down PB0 and press Reset. Continue holding PB0 until the display shows USB ON The Power Source Select Switch should be set to USB to enable the debug interface The USB micro connector is used as the Biometric-EXP demo debug interface. Figure 7. Enabling and Connecting to USB Debug Mode 4.1. Enabling USB Debug Mode ec om In order to maintain power efficiency of the demo, the USB debug mode is disabled by default. The LCD will show “USB OFF” during startup. To enable USB debug mode, the user must hold down button PB0 then press and release the Reset button. Both buttons are on the Gecko STK as shown in Figure 7. The user should hold down PB0 until the LCD shows “USB ON.” At this point, USB is enabled and the demo will run normally. To later disable USB debug mode the user can press the Reset button without holding PB0. 4.2. Connecting to USB Debug Mode on a PC N ot R Prior to using USB debug mode, the user must first install the Biometric-EXP Windows Evaluation Software. This will install the Windows applications and drivers necessary to use USB debug mode. The Gecko STK has two USB type connectors: a USB Mini type connector labeled J-Link on the short side of the EVB and a USB Micro type connector on the long side of the EVB. The USB Micro connector is used for the USB debug interface, as shown in Figure 7. In addition to using the correct physical interface, the Power Source Select switch must be set to USB (center position) for proper operation. USB debug mode utilizes a Virtual COM Port (VCP) interface to communicate between the Biometric-EXP demo and the PC. With the Windows software installed, USB debug mode enabled on the Wonder Gecko and a USB cable connecting the Wonder Gecko STK and the PC, the device will appear in Windows Device Manager as a COM port as shown in Figure 8. 8 Rev. 0.4 m en de d fo r N ew D es ig ns Biometric-EXP EVB   N ot R ec om Figure 8. Biometric-EXP Virtual COM Port Device in Windows Device Manager Rev. 0.4 9 Biometric-EXP EVB 4.3. Windows Applications for USB Debug Mode es ig ns The Biometric-EXP Windows Evaluation Software includes two Windows applications for evaluating and debugging the Biometric-EXP Heart Rate Monitor and SpO2 functions. An installation program for the BiometricEXP Windows Evaluation Software is distributed with Simplicity Studio. It can be found in the Installers directory within the Simplicity Studio directory structure. Following installation, the software can be launched from the Windows Start menu. om m en de d fo r N ew D The Windows Graphical User Interface (GUI) demo provides a waveform display of the HRM data along with the HRM and SpO2 calculated values. The GUI demo also allows the user to record the streaming data to a file for further analysis. A screenshot of the GUI demo is shown in Figure 9. Figure 9. Windows Graphical User Interface Demo N ot R ec The Windows Console Demo provides a running, once-per-second text output of many parameters that are used within the HRM and SpO2 algorithms including the HRM and SpO2 results. This tool can be used for advanced analysis of the HRM and SpO2 streaming data; however, the details of the parameters and how to use them to analyze a HRM-SpO2 recording is beyond the scope of this document. A screen shot of the Console demo is show in Figure 10. 10 Rev. 0.4 N ew D es ig ns Biometric-EXP EVB   fo r Figure 10. Windows Console Demo m en de d To connect the console to the streaming output from the Biometric-EXP, the user can type –u COMx at the prompt. In this command, COMx is the VCP COM port as shown in Figure 8, and the optional input specifies the file in which the streaming data is to be stored. Note that if is not provided, the console automatically stores the data to a default file. This default file is overwritten each time the demo is run. The console also has the ability to playback recorded files. This is done by typing –f filename at the prompt. In this command, filename specifies the source file containing the saved recording. N ot R ec om It is important to note that the USB debug interface is a one-way interface. Therefore, the applications can only take the streaming data as an input. They do not allow the user to control the Biometric-EXP software. Rev. 0.4 11 Biometric-EXP EVB 5. Hardware Overview 5.1. Block Diagram es ig ns Vmcu EXP Connector (JP3) EXP Connector (JP4) All other lines I2C Ribbon Connector (J6) 5V D TS3310 DC-DC Boost Converter I2C2 Si1146 Proximity/ UV/Ambient Light Sensor IR fo r I2C1 N ew Red m en de d Si7013 Humidity & Temperature Sensor Figure 11. Biometric-EXP Block Diagram 5.2. Hardware Connectors As illustrated in Figure 11 there are two separate I2C buses implemented on this board. The Si1146 is on its own bus while the Si7013 and the I2C Ribbon Connector J6 are on the second bus. This allows for expansion boards designed for the I2C Ribbon Connector to connect to the Biometric-EXP without the possibility of an I2C slave address conflict between any potential Si1145/Si1146/Si1147 devices on the expansion board. om Table 1 details the pinouts and signal function of the Biometric-EXP connectors JP3 and JP4. Table 1. Expansion Connectors (JP3 and JP4) Biometric-EXP Signal Description N ot R ec Pin # 12 WonderGecko Signal 1 GND GND 2 VMCU 3 Red LED D3 PC0 4 Not Used PD0 5 Green LED D3 PC3 6 Not Used PD1 7 Si7013 and I2C Ribbon Connector (J6) SDA PC4 VMCU Rev. 0.4 Biometric-EXP EVB Table 1. Expansion Connectors (JP3 and JP4) (Continued) Pin # Biometric-EXP Signal Description WonderGecko Signal Not Used PD2 9 Si7013 and I2C Ribbon Connector (J6) SCL PC5 10 Not Used PD3 11 Not Used PB11 12 Enable TS3310 Boost DC-DC Converter PD4 13 Not Used PB12 14 Si1146 and I2C Ribbon Connector (J6) INT 15 Not Used 16 Si1146 I2C SDA 17 Si1146 I2C SCL 18 Not Used 19 Not Used 20 3.3 V D es ig ns 8 PD5 N ew PC6 PD6 PD7 GND 3.3 V m en de d fo r 5V Table 2 details the pinouts and signal descriptions of the 6-pin I2C connector J6. Table 2. 6-Pin I2C Connector (J6) Signal Description 1 I2C SCL 2 5V 3 I2C SDA 4 GND 5 INT 6 VMCU N ot R ec om Pin # Rev. 0.4 13 Biometric-EXP EVB 5.3. Hardware Component Layout IR and Red LEDs es ig ns Si1146 Proximity/UV/Ambient Light D Silabs TS3310 DC-DC Boost Converter N ew Si7013 Humidity & Temperature EXP connector for EFM32 STK fo r I2C Ribbon Cable Connector Figure 12. Biometric-EXP Hardware Component Layout R 3RZHU6RXUFH 6HOHFW N ot /&' 5HVHW%XWWRQ (;3+HDGHU om ec &RLQ&HOO %DWWHU\ m en de d -/LQN'HYHORSPHQW ,QWHUIDFH ()0:RQGHU *HFNR 0&8 %XWWRQ3% 86%'HEXJ,QWHUIDFH %XWWRQ3% Figure 13. Wonder Gecko STK Component Layout 5.4. Schematics, Assembly Drawings, and BOM The schematics, assembly drawings and bill of materials (BOM) for the Biometric-EXP-EVB are available through Simplicity Studio when the EXP documentation package has been installed. 14 Rev. 0.4 Biometric-EXP EVB DOCUMENT CHANGE LIST     Revision 0.2 to Revision 0.3 m en de d  Removed the description(s) of operation with a HRM-GGG-PS EVB. The Biometric-EXP demo does not support wrist-based heart rate monitoring.  Removed a comment indicating that the C++ source code for the Windows Console Demo is supplied with the installation. This source code is available by request only. Revision 0.3 to Revision 0.4  Removed HRM-SpO2 API Reference Manual  N ot R ec om reference. 15 D  Added "1.2. Getting Started" on page 1. Modified “2. Loading the Demo Onto the Gecko Starter Kit” to describe how to load the demo that is integrated into Simplicity Studio Added a comment in“3.2. Heart Rate Monitor Mode” describing the proper finger pressure. Added Figure 7, “Enabling and Connecting to USB Debug Mode,” on page 8. Added a comment in “4.3. Windows Applications for USB Debug Mode” describing where to find the Windows software installation program within Simplicity Studio Removed the section describing how to import the project source into Simplicity Studio. It is now integrated and imports seamlessly Removed the schematic as it is now a separate document in Simplicity Studio. N ew  fo r  es ig ns Revision 0.1 to Revision 0.2 Rev. 0.4 es ig ns D N ew fo r om Products m en de d Smart. Connected. Energy-Friendly. www.silabs.com/products Quality www.silabs.com/quality Support and Community community.silabs.com N ot R ec Disclaimer Silicon Laboratories intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Laboratories reserves the right to make changes without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy or completeness of the included information. Silicon Laboratories shall have no liability for the consequences of use of the information supplied herein. This document does not imply or express copyright licenses granted hereunder to design or fabricate any integrated circuits. The products are not designed or authorized to be used within any Life Support System without the specific written consent of Silicon Laboratories. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected to result in significant personal injury or death. Silicon Laboratories products are not designed or authorized for military applications. Silicon Laboratories products shall under no circumstances be used in weapons of mass destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons. Trademark Information Silicon Laboratories Inc.® , Silicon Laboratories®, Silicon Labs®, SiLabs® and the Silicon Labs logo®, Bluegiga®, Bluegiga Logo®, Clockbuilder®, CMEMS®, DSPLL®, EFM®, EFM32®, EFR, Ember®, Energy Micro, Energy Micro logo and combinations thereof, "the world’s most energy friendly microcontrollers", Ember®, EZLink®, EZRadio®, EZRadioPRO®, Gecko®, ISOmodem®, Precision32®, ProSLIC®, Simplicity Studio®, SiPHY®, Telegesis, the Telegesis Logo®, USBXpress® and others are trademarks or registered trademarks of Silicon Laboratories Inc. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand names mentioned herein are trademarks of their respective holders. Silicon Laboratories Inc. 400 West Cesar Chavez Austin, TX 78701 USA http://www.silabs.com
BIOMETRIC-EXP-EVB 价格&库存

很抱歉,暂时无法提供与“BIOMETRIC-EXP-EVB”相匹配的价格&库存,您可以联系我们找货

免费人工找货
BIOMETRIC-EXP-EVB
    •  国内价格
    • 2+334.62939
    • 8+321.29787

    库存:8