Si4736/37/38/39-C40
B R O A D C A S T A M / F M R ADIO R E C E IV E R
Features
Integrated LDO regulator
2.0 to 5.5 V supply voltage (SSOP)
Wide range of ferrite loop sticks and
air loop antennas supported
QFN and SSOP packages
RoHS compliant
Si4736/37/38/39 (QFN)
NC
Emergency radios
Table and portable radios
Stereos
Mini/micro systems
Boom boxes
Modules
Clock radios
Mini HiFi
Si473x
LNA
AGC
LOW-IF
ADC
ADC
LDO
AFC
RCLK
GND
DOUT
DFS
GPO/DCLK
DAC
ROUT
DAC
LOUT
CONTROL
INTERFACE
RST
2.7– 5.5 V (QFN)
2.0– 5.5 V (SSOP) VDD
SEN
AGC
18
17
16
15 DOUT
GND
PAD
14 LOUT
RST 5
12 GND
6
7
8
9
11 VDD
13 ROUT
10
Si4736/37 (SSOP)
DOUT
1
24
LOUT
DFS
2
23
ROUT
GPO3/DCLK
3
22
DBYP
GPO2/INT
4
21
VDD
GPO1
5
20
VIO
NC
6
19
RCLK
NC
7
18
SDIO
FMI
8
17
SCLK
RFGND
9
16
SEN
NC
10
15
RST
NC
11
14
GND
AMI
12
13
GND
DSP
SCLK
FMI
LNA
DIGITAL
AUDIO
(Si4737/
39)
SDIO
RFGND
19
AMI 4
Functional Block Diagram
RDS
(Si4737/
39)
20
RFGND 3
The Si4736/37/38/39 is the first digital CMOS AM/FM radio receiver IC that
integrates the complete tuner function from antenna input to audio output.
AMI
1
FMI 2
Description
FM/
WB
ANT
Pin Assignments
2.7 to 5.5 V supply voltage (QFN)
Applications
AM
ANT
Ordering Information:
See page 31.
DFS
2-wire and 3-wire control interface
GPO3/DCLK
Optional digital audio out (Si4737/39)
VIO
RDS/RBDS processor (Si4737/39)
GPO2/INT
Adjustable soft mute control
GPO1
Volume control
SDIO
Programmable reference clock
RCLK
No manual alignment necessary
SEN
AM/FM/WB digital tuning
SCLK
(162.4–162.55 MHz)
Worldwide FM band support
(64–108 MHz)
Worldwide AM band support
(520–1710 kHz) (Si4736/37)
1050 Hz alert tone detection
Excellent real-world performance
Freq synthesizer with integrated VCO
Advanced AM/FM seek tuning
Automatic frequency control (AFC)
Automatic gain control (AGC)
Digital FM stereo decoder
Programmable AVC max gain
Programmable de-emphasis
NC
NOAA weather band support
VIO
1.85–3.6 V
This product, its features, and/or its
architecture is covered by one or more of
the following patents, as well as other
patents, pending and issued, both foreign
and domestic: 7,127,217; 7,272,373;
7,272,375;
7,321,324;
7,355,476;
7,426,376;
7,471,940;
7,339,503;
7,339,504.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
TABLE O F C ONTENTS
Section
Page
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2. Typical Application Schematic (QFN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3. Typical Application Schematic (SSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4. Bill of Materials (QFN/SSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2. Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.3. FM Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.4. AM Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.5. Weather Band Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.6. Digital Audio Interface (Si4737/39 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.7. Stereo Audio Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.8. De-emphasis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.9. Stereo DAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
5.10. Soft Mute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.11. RDS/RBDS Processor (Si4737/39 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.12. Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.13. Seek . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.14. Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.15. Control Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.16. GPO Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.17. Firmware Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.18. Reset, Powerup, and Powerdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.19. Programming with Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6. Commands and Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7. Pin Descriptions: Si4736/37/38/39-GM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
8. Pin Descriptions: Si4736/37-GU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10. Package Markings (Top Marks) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.1. Si4736/37/38/39 Top Mark (QFN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.2. Top Mark Explanation (QFN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.3. Si4736/37 Top Mark (SSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
10.4. Top Mark Explanation (SSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
11. Package Outline: Si4736/37/38/39 QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
12. PCB Land Pattern: Si4736/37/38/39 QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
13. Package Outline: Si4736/37 SSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
14. PCB Land Pattern: Si4736/37 SSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
15. Additional Reference Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
1. Electrical Specifications
Table 1. Recommended Operating Conditions1
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Supply Voltage2
VDD
2.7
—
5.5
V
Interface Supply Voltage
VIO
1.85
—
3.6
V
Power Supply Powerup Rise Time
VDDRISE
10
—
—
µs
Interface Power Supply Powerup Rise Time
VIORISE
10
—
—
µs
TA
–20
25
85
C
Ambient Temperature
Note:
1. All minimum and maximum specifications apply across the recommended operating conditions. Typical values apply at
VDD = 3.3 V and 25 C unless otherwise stated.
2. SSOP devices operate down to VDD = 2 V at 25 °C.
Table 2. Absolute Maximum Ratings1,2
Parameter
Symbol
Value
Unit
Supply Voltage
VDD
–0.5 to 5.8
V
Interface Supply Voltage
VIO
–0.5 to 3.9
V
Input Current3
IIN
10
mA
Input Voltage3
VIN
–0.3 to (VIO + 0.3)
V
Operating Temperature
TOP
–40 to 95
C
Storage Temperature
TSTG
–55 to 150
C
0.4
VPK
RF Input Level4
Notes:
1. Permanent device damage may occur if the above Absolute Maximum Ratings are exceeded. Functional operation
should be restricted to the conditions as specified in the operational sections of this data sheet. Exposure beyond
recommended operating conditions for extended periods may affect device reliability.
2. The Si4736/37/38/39 devices are high-performance RF integrated circuits with certain pins having an ESD rating of <
2 kV HBM. Handling and assembly of these devices should only be done at ESD-protected workstations.
3. For input pins SCLK, SEN, SDIO, RST, RCLK, and DCLK.
4. At RF input pins, FMI and AMI.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
3
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 3. DC Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
—
19.2
22
mA
—
19.9
23
mA
IFM
—
19.2
23
mA
Supply Current1
IFM
—
19.2
22
mA
Supply Current
IFM
Low SNR level
—
19.8
23
mA
IAM
Analog Output Mode
—
15.4
20.5
mA
FM Mode
Supply Current1
IFM
2
IFM
Supply Current
RDS Supply Current1
Low SNR level
WB Mode
AM Mode
Supply Current1
Supplies and Interface
Interface Supply Current
IIO
—
320
600
µA
VDD Powerdown Current
IDDPD
—
10
20
µA
VIO Powerdown Current
IIOPD
—
1
10
µA
SCLK, RCLK inactive
High Level Input Voltage3
VIH
0.7 x VIO
—
VIO + 0.3
V
Low Level Input Voltage3
VIL
–0.3
—
0.3 x VIO
V
High Level Input Current3
IIH
VIN = VIO = 3.6 V
–10
—
10
µA
Low Level Input Current3
IIL
VIN = 0 V,
VIO = 3.6 V
–10
—
10
µA
High Level Output Voltage4
VOH
IOUT = 500 µA
0.8 x VIO
—
—
V
Voltage4
VOL
IOUT = –500 µA
—
—
0.2 x VIO
V
Low Level Output
Notes:
1. Specifications are guaranteed by characterization.
2. LNA is automatically switched to higher current mode for optimum sensitivity in weak signal conditions.
3. For input pins SCLK, SEN, SDIO, RST, RCLK, and DCLK.
4. For output pins SDIO, DOUT, GPO1, GPO2, and GPO3.
4
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 4. Reset Timing Characteristics1,2,3
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Min
Typ
Max
Unit
RST Pulse Width and GPO1, GPO2/INT Setup to RST
tSRST
100
—
—
µs
GPO1, GPO2/INT Hold from RST
tHRST
30
—
—
ns
Important Notes:
1. When selecting 2-wire mode, the user must ensure that a 2-wire start condition (falling edge of SDIO while SCLK is
high) does not occur within 300 ns before the rising edge of RST.
2. When selecting 2-wire mode, the user must ensure that SCLK is high during the rising edge of RST, and stays high until
after the first start condition.
3. When selecting 3-wire or SPI modes, the user must ensure that a rising edge of SCLK does not occur within 300 ns
before the rising edge of RST.
4. If GPO1 and GPO2 are actively driven by the user, then minimum tSRST is only 30 ns. If GPO1 or GPO2 is hi-Z, then
minimum tSRST is 100 µs, to provide time for on-chip 1 M devices (active while RST is low) to pull GPO1 high and
GPO2 low.
tSRST
RST
70%
GPO1
70%
GPO2/
INT
tHRST
30%
30%
70%
30%
Figure 1. Reset Timing Parameters for Busmode Select
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
5
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 5. 2-Wire Control Interface Characteristics1,2,3
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
SCLK Frequency
fSCL
0
—
400
kHz
SCLK Low Time
tLOW
1.3
—
—
µs
SCLK High Time
tHIGH
0.6
—
—
µs
SCLK Input to SDIO Setup (START)
tSU:STA
0.6
—
—
µs
SCLK Input to SDIO Hold (START)
tHD:STA
0.6
—
—
µs
SDIO Input to SCLK Setup
tSU:DAT
100
—
—
ns
SDIO Input to SCLK Hold4,5
tHD:DAT
0
—
900
ns
SCLK input to SDIO Setup (STOP)
tSU:STO
0.6
—
—
µs
STOP to START Time
tBUF
1.3
—
—
µs
SDIO Output Fall Time
tf:OUT
—
250
ns
—
300
ns
Cb
20 + 0.1 ----------1pF
SDIO Input, SCLK Rise/Fall Time
tf:IN
tr:IN
Cb
20 + 0.1 ----------1pF
SCLK, SDIO Capacitive Loading
Cb
—
—
50
pF
Input Filter Pulse Suppression
tSP
—
—
50
ns
Notes:
1. When VIO = 0 V, SCLK and SDIO are low impedance.
2. When selecting 2-wire mode, the user must ensure that a 2-wire start condition (falling edge of SDIO while SCLK is
high) does not occur within 300 ns before the rising edge of RST.
3. When selecting 2-wire mode, the user must ensure that SCLK is high during the rising edge of RST, and stays high
until after the first start condition.
4. The Si4736/37/38/39 delays SDIO by a minimum of 300 ns from the VIH threshold of SCLK to comply with the
minimum tHD:DAT specification.
5. The maximum tHD:DAT has only to be met when fSCL = 400 kHz. At frequencies below 400 KHz, tHD:DAT may be
violated as long as all other timing parameters are met.
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
SCLK
70%
SDIO
70%
tSU:STA tHD:STA
tLOW
START
tr:IN
tHIGH
tr:IN
tf:IN
tSP
tSU:STO
tBUF
30%
30%
tf:IN,
tf:OUT
tHD:DAT tSU:DAT
STOP
START
Figure 2. 2-Wire Control Interface Read and Write Timing Parameters
SCLK
A6-A0,
R/W
SDIO
START
ADDRESS + R/W
D7-D0
ACK
DATA
D7-D0
ACK
DATA
ACK
STOP
Figure 3. 2-Wire Control Interface Read and Write Timing Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
7
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 6. 3-Wire Control Interface Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
SCLK Frequency
fCLK
0
—
2.5
MHz
SCLK High Time
tHIGH
25
—
—
ns
SCLK Low Time
tLOW
25
—
—
ns
tS
20
—
—
ns
SDIO Input to SCLKHold
tHSDIO
10
—
—
ns
SEN Input to SCLKHold
tHSEN
10
—
—
ns
SCLKto SDIO Output Valid
tCDV
Read
2
—
25
ns
SCLKto SDIO Output High Z
tCDZ
Read
2
—
25
ns
SCLK, SEN, SDIO, Rise/Fall time
tR, tF
—
—
10
ns
SDIO Input, SEN to SCLKSetup
Note: When selecting 3-wire mode, the user must ensure that a rising edge of SCLK does not occur within 300 ns before the
rising edge of RST.
SCLK
70%
30%
tR
tF
tHSDIO
tS
SEN
70%
SDIO
70%
tHIGH
tLOW
tHSEN
tS
30%
A7
30%
A6-A5,
R/W,
A4-A1
A0
D15
D14-D1
Address In
D0
Data In
Figure 4. 3-Wire Control Interface Write Timing Parameters
SCLK
70%
SEN
70%
30%
tHSDIO
tS
tCDV
tHSEN
tCDZ
tS
30%
70%
SDIO
A7
30%
A6-A5,
R/W,
A4-A1
Address In
A0
D15
½ Cycle Bus
Turnaround
D14-D1
D0
Data Out
Figure 5. 3-Wire Control Interface Read Timing Parameters
8
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 7. SPI Control Interface Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
SCLK Frequency
fCLK
0
—
2.5
MHz
SCLK High Time
tHIGH
25
—
—
ns
SCLK Low Time
tLOW
25
—
—
ns
tS
15
—
—
ns
SDIO Input to SCLKHold
tHSDIO
10
—
—
ns
SEN Input to SCLKHold
tHSEN
5
—
—
ns
SCLKto SDIO Output Valid
tCDV
Read
2
—
25
ns
SCLKto SDIO Output High Z
tCDZ
Read
2
—
25
ns
SCLK, SEN, SDIO, Rise/Fall time
tR, tF
—
—
10
ns
SDIO Input, SEN to SCLKSetup
Note: When selecting SPI mode, the user must ensure that a rising edge of SCLK does not occur within 300 ns before the
rising edge of RST.
SCLK
70%
30%
tR
tHIGH
SEN
70%
SDIO
70%
tS
tLOW
tF
tHSDIO
tHSEN
tS
30%
C7
C6–C1
C0
D7
D6–D1
D0
30%
Control Byte In
8 Data Bytes In
Figure 6. SPI Control Interface Write Timing Parameters
SCLK
70%
30%
tCDV
tS
SEN
70%
tHSEN
tHSDIO
tS
30%
tCDZ
SDIO
70%
C7
C6 –C1
C0
D7
D6 –D1
D0
30%
Control Byte In
Bus
Turnaround
16 Data Bytes Out
(SDIO or GPO1)
Figure 7. SPI Control Interface Read Timing Parameters
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
9
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 8. Digital Audio Interface Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
DCLK Cycle Time
tDCT
26
—
1000
ns
DCLK Pulse Width High
tDCH
10
—
—
ns
DCLK Pulse Width Low
tDCL
10
—
—
ns
DFS Set-up Time to DCLK Rising Edge
tSU:DFS
5
—
—
ns
DFS Hold Time from DCLK Rising Edge
tHD:DFS
5
—
—
ns
tPD:DOUT
0
—
12
ns
DOUT Propagation Delay from DCLK Falling Edge
tDCH
tDCL
DCLK
tDCT
DFS
tHD:DFS
tSU:DFS
DOUT
tPD:OUT
Figure 8. Digital Audio Interface Timing Parameters, I2S Mode
10
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 9. FM Receiver Characteristics1,2
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Min
Typ
Max
Unit
76
—
108
MHz
(S+N)/N = 26 dB
—
2.2
3.5
µV EMF
(S+N)/N = 26 dB
—
1.1
—
µV EMF
f = 2 kHz,
RDS BLER < 5%
—
15
—
µV EMF
3
4
5
k
4
5
6
pF
100
105
—
dBµV EMF
m = 0.3
40
50
—
dB
Adjacent Channel Selectivity
±200 kHz
35
50
—
dB
Alternate Channel Selectivity
±400 kHz
60
70
—
dB
In-band
35
—
—
dB
72
80
90
mVRMS
—
—
1
dB
Input Frequency
fRF
Sensitivity with Headphone
Sensitivity with 50
RDS
Test Condition
Network3,4,5
Network3,4,5,6
Sensitivity6
LNA Input Resistance6,7
LNA Input
Capacitance6,7
Input IP36,8
AM
Suppression3,4,6,7
Spurious Response
Audio Output
Rejection6
Voltage3,4,7
Audio Output L/R Imbalance3,7,9
Audio Frequency Response
Low6
–3 dB
—
—
30
Hz
Audio Frequency Response
High6
–3 dB
15
—
—
kHz
32
42
—
dB
55
63
—
dB
—
58
—
dB
—
0.1
0.5
%
FM_DEEMPHASIS = 2
70
75
80
µs
FM_DEEMPHASIS = 1
45
50
54
µs
f = ±400 kHz
—
32
—
dBµV
f = ±4 MHz
—
38
—
dBµV
Audio Stereo Separation7,9
Audio Mono
S/N3,4,5,7,10
Audio Stereo
S/N4,5,6,7,10,11
Audio THD3,7,9
De-emphasis Time
Constant6
Blocking Sensitivity3,4,5,6,12,13
Notes:
1. Additional testing information is available in “AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure.”
Volume = maximum for all tests. Tested at RF = 98.1 MHz.
2. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
3. FMOD = 1 kHz, 75 µs de-emphasis, MONO = enabled, and L = R unless noted otherwise.
4. f = 22.5 kHz.
5. BAF = 300 Hz to 15 kHz, A-weighted.
6. Guaranteed by characterization.
7. VEMF = 1 mV.
8. |f2 – f1| > 2 MHz, f0 = 2 x f1 – f2. AGC is disabled.
9. f = 75 kHz.
10. At LOUT and ROUT pins.
11. Analog audio output mode.
12. Blocker Amplitude = 100 dBµV
13. Sensitivity measured at (S+N)/N = 26 dB.
14. At temperature (25°C).
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
11
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 9. FM Receiver Characteristics1,2 (Continued)
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Intermode
Symbol
Sensitivity3,4,5,6,12,13
Test Condition
Min
Typ
Max
Unit
f = ±400 kHz, ±800 kHz
—
40
—
dBµV
f = ±4 MHz, ±8 MHz
—
35
—
dBµV
Audio Output Load
Resistance6,10
RL
Single-ended
10
—
—
k
Audio Output Load
Capacitance6,10
CL
Single-ended
—
—
50
pF
RCLK tolerance = 100 ppm
—
—
60
ms/channel
From powerdown
—
—
110
ms
Input levels of 8 and
60 dBµV at RF Input
–3
—
3
dB
Seek/Tune Time6
Powerup
RSSI
Time6
Offset14
Notes:
1. Additional testing information is available in “AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure.”
Volume = maximum for all tests. Tested at RF = 98.1 MHz.
2. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
3. FMOD = 1 kHz, 75 µs de-emphasis, MONO = enabled, and L = R unless noted otherwise.
4. f = 22.5 kHz.
5. BAF = 300 Hz to 15 kHz, A-weighted.
6. Guaranteed by characterization.
7. VEMF = 1 mV.
8. |f2 – f1| > 2 MHz, f0 = 2 x f1 – f2. AGC is disabled.
9. f = 75 kHz.
10. At LOUT and ROUT pins.
11. Analog audio output mode.
12. Blocker Amplitude = 100 dBµV
13. Sensitivity measured at (S+N)/N = 26 dB.
14. At temperature (25°C).
12
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 10. 64–75.9 MHz Input Frequency FM Receiver Characteristics1,2,6
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Input Frequency
Test Condition
fRF
Sensitivity with Headphone
Network3,4,5
Typ
Max
Unit
64
—
75.9
MHz
—
4.0
—
µV EMF
LNA Input
Resistance7
3
4
5
k
LNA Input
Capacitance7
4
5
6
pF
100
105
—
dBµV EMF
m = 0.3
40
50
—
dB
Adjacent Channel Selectivity
±200 kHz
—
50
—
dB
Alternate Channel Selectivity
±400 kHz
—
70
—
dB
72
80
90
mVRMS
—
—
1
dB
Input
AM
(S+N)/N = 26 dB
Min
IP38
Suppression3,4,7
Audio Output
Voltage3,4,7
Audio Output L/R
Imbalance3,7,9
Audio Frequency Response Low
–3 dB
—
—
30
Hz
Audio Frequency Response High
–3 dB
15
—
—
kHz
55
63
—
dB
—
0.1
0.5
%
FM_DEEMPHASIS = 2
70
75
80
µs
FM_DEEMPHASIS = 1
45
50
54
µs
Audio Mono
Audio
S/N3,4,5,7,10
THD3,7,9
De-emphasis Time Constant
Audio Output Load
Resistance10
RL
Single-ended
10
—
—
k
Audio Output Load
Capacitance10
CL
Single-ended
—
—
50
pF
RCLK tolerance
= 100 ppm
—
—
60
ms/channel
From powerdown
—
—
110
ms
Input levels of 8 and
60 dBµV EMF
–3
—
3
dB
Seek/Tune Time
Powerup Time
RSSI
Offset11
Notes:
1. Additional testing information is available in “AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure.”
Volume = maximum for all tests. Tested at RF = 98.1 MHz.
2. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
3. FMOD = 1 kHz, 75 µs de-emphasis, MONO = enabled, and L = R unless noted otherwise.
4. f = 22.5 kHz.
5. BAF = 300 Hz to 15 kHz, A-weighted.
6. Guaranteed by characterization.
7. VEMF = 1 mV.
8. |f2 – f1| > 2 MHz, f0 = 2 x f1 – f2. AGC is disabled.
9. f = 75 kHz.
10. At LOUT and ROUT pins.
11. At temperature (25 °C).
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
13
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 11. WB Receiver Characteristics1
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6V, TA = 25 °C)
Parameter
Symbol
Input Frequency
Test Condition
Min
Typ
Max
Unit
162.4
—
162.55
MHz
SINAD = 12 dB
—
0.9
—
µV EMF
±25 kHz
—
52
—
dB
fR
Sensitivity2,3
Adjacent Channel Selectivity
Audio S/N2,3,4,5
Mono
—
45
—
dB
Audio Frequency Response
Low6
–3 dB
—
—
300
Hz
Audio Frequency Response
High6
–3 dB
3
—
—
kHz
Notes:
1. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
2. FMOD = 1 kHz.
3. f = 3 kHz.
4. VEMF = 1 mV.
5. A-weighted.
6. Guaranteed by characterization
Table 12. AM Receiver Characteristics1,2
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Input Frequency
Handling4,,6,7
Power Supply Rejection Ratio6
Audio Output
Test Condition
Min
Typ
Max
Unit
520
—
1710
kHz
(S+N)/N = 26 dB
—
25
35
µV EMF
THD < 8%
—
300
—
mVRMS
ΔVDD = 100 mVRMS, 100 Hz
—
40
—
dB
54
60
67
mVRMS
fRF
Sensitivity3,4,5,6
Large Signal Voltage
Symbol
Voltage3,4,8
Audio S/N3,4,5,8
50
56
—
dB
THD3,4,8
—
0.1
0.5
%
Antenna Inductance6,9
180
—
450
µH
—
—
110
ms
Audio
Powerup
Time6
From powerdown
Notes:
1. Additional testing information is available in “AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure.”
Volume = maximum for all tests. Tested at RF = 520 kHz.
2. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
3. FMOD = 1 kHz, 30% modulation, 2 kHz channel filter.
4. Analog audio output mode.
5. BAF = 300 Hz to 15 kHz, A-weighted.
6. Guaranteed by characterization.
7. See “AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure” for evaluation method.
8. VIN = 5 mVrms.
9. Stray capacitance on antenna and board must be < 10 pF to achieve full tuning range at higher inductance levels.
14
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 13. Reference Clock and Crystal Characteristics
(VDD = 2.7 to 5.5 V, VIO = 1.85 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
31.130
32.768
40,000
kHz
–50
—
50
ppm
1
—
4095
31.130
32.768
34.406
kHz
Crystal Oscillator Frequency
—
32.768
—
kHz
Crystal Frequency Tolerance2
–50
—
50
ppm
—
—
3.5
pF
Reference Clock
RCLK Supported Frequencies1
RCLK Frequency Tolerance2
REFCLK_PRESCALE
REFCLK
Crystal Oscillator
Board Capacitance
Notes:
1. The Si4736/37/38/39 divides the RCLK input by REFCLK_PRESCALE to obtain REFCLK. There are some RCLK
frequencies between 31.130 kHz and 40 MHz that are not supported. For more details, see Table 6 of “AN332: Si47xx
Programming Guide”.
2. A frequency tolerance of ±50 ppm is required for FM seek/tune using 50 kHz channel spacing and WB tune.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
15
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
2. Typical Application Schematic (QFN)
GPO1
GPO2/INT
R1
R2
GPO3/DCLK
FMIP
L1
2 FMI
3 RFGND
4 AMI
5
GPO3/DCLK
DFS
DOUT
15
R3
Optional: Digital Audio Output
14
U1
13
Si4736/37/38/39-GM ROUT/DOUT
12
LOUT/DFS
GND
VDD
RST
DOUT
LOUT
ROUT
11
VBATTERY
2.7 to 5.5 V
C1
RST
SEN
SCLK
SDIO
RCLK
VIO
1.85 to 3.6 V
6
7
8
9
10
SEN
SCLK
SDIO
RCLK
VIO
AM antenna
Si4736/37 only C5
NC
GPO2/INT
1
GPO1
NC
20
19
18
17
16
DFS
X1
GPO3
C2
RCLK
C3
Optional: for crystal oscillator option
L2
RFGND
AMI
T1
C5
Optional: AM air loop antenna
Notes:
1. Place C1 close to VDD pin.
2. All grounds connect directly to GND plane on PCB.
3. Pins 1 and 20 are no connects, leave floating.
4. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
5. Pin 2 connects to the FM antenna interface, and pin 4 connects to the AM antenna interface.
6. Place Si4736/37/38/39 as close as possible to antenna and keep the FMI and AMI traces as short as possible.
16
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
3. Typical Application Schematic (SSOP)
Optional: Digital Audio Output
R3
DOUT
1
C4
R2
DFS
2
R1
3
GPO3/DCLK
4
GPO2/INT
5
GPO1
NC
6
NC
7
FMI
L1
AM antenna
Si4736/37 only
8
RFGND 9
10
NC
11
NC
AMI
12
C2
LOUT
23
ROUT
DBYP
22
C1
2.0 to 5.5 V
21 VDD
VIO
1.85 to 3.6 V
20
19
RCLK
SDIO
18
17
16
15
14
13
SCLK
SEN
RST
GND
C5
X1
GPIO3
24
RCLK
F2
RFGND
C3
AMI
T1
Optional: for crystal oscillator option
C5
Optional: AM air loop antenna
Notes:
1. Place C1 close to VDD and DBYP pins.
2. All grounds connect directly to GND plane on PCB.
3. Pins 6 and 7 are no connects, leave floating.
4. Pins 10 and 11 are unused. Tie these pins to GND.
5. To ensure proper operation and receiver performance, follow the guidelines in “AN383: Si47xx Antenna, Schematic,
Layout, and Design Guidelines.” Skyworks will evaluate schematics and layouts for qualified customers.
6. Pin 8 connects to the FM antenna interface, and pin 12 connects to the AM antenna interface.
7. Place Si4736/37/38/39 as close as possible to antenna and keep the FMI and AMI traces as short as possible.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
17
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
4. Bill of Materials (QFN/SSOP)
Component(s)
Value/Description
Supplier
C1
Supply bypass capacitor, 22 nF, ±20%, Z5U/X7R
Murata
C5
Coupling capacitor, 0.47 µF, ±20%, Z5U/X7R
Murata
L1
Ferrite loop stick, 180–450 µH
Jiaxin
U1
Si4736/37/38/39 AM/FM Radio Tuner
Skyworks
Optional Components
T1
Transformer, 1–5 turns ratio
Jiaxin, UMEC
L2
Air loop antenna, 10–20 µH
Various
Crystal load capacitors, 22 pF, ±5%, COG
(Optional for crystal oscillator option)
Venkel
C4
Noise mitigating capacitor, 2~5 pF(Optional for digital audio)
Murata
X1
32.768 kHz crystal (Optional for crystal oscillator option)
Epson
R1
Resistor, 2 k(Optional for digital audio)
Venkel
R2
Resistor, 2 k(Optional for digital audio)
Venkel
R3
Resistor, 600 (Optional for digital audio)
Venkel
C2, C3
18
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5. Functional Description
5.1. Overview
Si473x
AMI
RDS
(Si4737/
39)
LNA
AGC
ADC
AGC
ADC
AFC
RCLK
LDO
DFS
GPO/DCLK
DAC
ROUT
DAC
LOUT
DSP
2.7– 5.5 V (QFN)
2.0– 5.5 V (SSOP) VDD
GND
DOUT
CONTROL
INTERFACE
VIO
1.85–3.6 V
RST
FMI
LNA
SEN
FM/
WB
ANT
LOW-IF
DIGITAL
AUDIO
(Si4737/
39)
SDIO
RFGND
SCLK
AM
ANT
Figure 9. Functional Block Diagram
The Si4736/37 and Si4738/39 are the industry's first fully integrated, 100% CMOS AM/FM/WB and FM/WB radio
receiver ICs. Offering unmatched integration and PCB space savings, the Si4736/37/38/39 requires only two
external components and less than 15 mm2 of board area, excluding the antenna inputs. The Si4736/37/38/39
AM/FM/WB radio provides the space savings and low power consumption necessary for portable devices while
delivering the high performance and design simplicity desired for all AM/FM/WB solutions.
Leveraging Skyworks' proven and patented Si4700/01 FM tuner's digital low intermediate frequency (low-IF)
receiver architecture, the Si4736/37/38/39 delivers superior RF performance and interference rejection in both AM
and FM bands. The high integration and complete system production test simplifies design-in, increases system
quality, and improves manufacturability.
The Si4736/37/38/39 is a feature-rich solution including 1050 Hz tone detection, advanced seek algorithms, soft
mute, auto-calibrated digital tuning, and FM stereo processing. In addition, the Si4736/37/38/39 provides analog
and digital audio outputs and a programmable reference clock. The device supports I2C-compatible, 2-wire control
interface, SPI, and a Si4700/01 backwards-compatible, 3-wire control interface.
The Si4736/37/38/39 utilizes digital processing to achieve high fidelity, optimal performance, and design flexibility.
The chip provides excellent pilot rejection, selectivity, and unmatched audio performance, and offers both the
manufacturer and the end-user extensive programmability and flexibility in listening experience.
The Si4737/39 incorporates a digital processor for the European Radio Data System (RDS) and the North
American Radio Broadcast Data System (RBDS), and includes all required symbol decoding, block
synchronization, error detection, and error correction functions. Using this feature, the Si4737/39 enables
broadcast data such as station identification and song name to be displayed to the user.
5.2. Operating Modes
The Si4736/37/38/39 operates in an FM receive, an AM receive, or a weather band receive mode. In FM mode and
WB mode, radio signals are received on FMI and processed by the FM front-end circuitry. In AM mode, radio
signals are received on AMI and processed by the AM front-end circuitry. In addition to the receiver mode, there is
a clocking mode to choose to clock the Si4736/37/38/39 from a reference clock or crystal. On the Si4731, there is
an audio output mode to choose between an analog and/or digital audio output. In the analog audio output mode,
ROUT and LOUT are used for the audio output pins. In the digital audio mode, DOUT, DFS, and DCLK pins are
used. Concurrent analog/digital audio output mode is also available requiring all five pins. The receiver mode and
the audio output mode are set by the POWER_UP command listed in Table 15, “Selected Si473x Commands,” on
page 26.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
19
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5.3. FM Receiver
The Si4736/37/38/39 FM receiver is based on the
proven Si4700/01 FM tuner. The receiver uses a digital
low-IF architecture allowing the elimination of external
components
and
factory
adjustments.
The
Si4736/37/38/39 integrates a low noise amplifier (LNA)
supporting the worldwide FM broadcast band (64 to 108
MHz). An AGC circuit controls the gain of the LNA to
optimize sensitivity and rejection of strong interferers.
An image-reject mixer downconverts the RF signal to
low-IF. The quadrature mixer output is amplified,
filtered, and digitized with high resolution analog-todigital converters (ADCs). This advanced architecture
allows the Si4736/37/38/39 to perform channel
selection, FM demodulation, and stereo audio
processing to achieve superior performance compared
to traditional analog architectures.
5.4. AM Receiver
The highly-integrated Si4736/37/38/39 supports
worldwide AM band reception from 520 to 1710 kHz
using a digital low-IF architecture with a minimum
number of external components and no manual
alignment required. This digital low-IF architecture
allows for high-precision filtering offering excellent
selectivity and SNR with minimum variation across the
AM band. The DSP also provides adjustable channel
step sizes in 1 kHz increments, AM demodulation, soft
mute, seven different channel bandwidth filters, and
additional features, such as a programmable automatic
volume control (AVC) maximum gain allowing users to
adjust the level of background noise. Similar to the FM
receiver, the integrated LNA and AGC optimize
sensitivity and rejection of strong interferers allowing
better reception of weak stations.
The Si4736/37/38/39 provides highly-accurate digital
AM tuning without factory adjustments. To offer
maximum flexibility, the receiver supports a wide range
of ferrite loop sticks from 180–450 µH. An air loop
antenna is supported by using a transformer to increase
the effective inductance from the air loop. Using a 1:5
turn ratio inductor, the inductance is increased by 25
times and easily supports all typical AM air loop
antennas which generally vary between 10 and 20 µH.
5.5. Weather Band Receiver
The Si4736/37/38/39 supports weather band reception
from 162.4 to 162.55 MHz. The highly integrated
Si4736/37/38/39 meets NOAA specification, receives all
seven NOAA specified frequencies, implements narrowband FM de-emphasis, and supports 1050 Hz alert tone
detection. In addition, the Si4736/37/38/39 provides
advanced features not available on conventional radios,
such as an AFC and a dynamic channel bandwidth filter.
The AFC locks on to the strongest signal within a
narrow, adjustable frequency range to compensate for
any potential frequency errors such as crystal tolerance
or transmit frequency errors. The AFC ensures the
channel filter is always centered on the desired channel
providing optimal reception. The dynamic channel
bandwidth feature utilizes a wide filter in strong signal
conditions to provide best sound quality and a narrower
filter in weak conditions to provide best sensitivity.
5.6. Digital Audio Interface
(Si4737/39 Only)
The digital audio interface operates in slave mode and
supports three different audio data formats:
I2S
Left-Justified
DSP Mode
5.6.1. Audio Data Formats
In I2S mode, by default the MSB is captured on the
second rising edge of DCLK following each DFS
transition. The remaining bits of the word are sent in
order, down to the LSB. The left channel is transferred
first when the DFS is low, and the right channel is
transferred when the DFS is high.
In Left-Justified mode, by default the MSB is captured
on the first rising edge of DCLK following each DFS
transition. The remaining bits of the word are sent in
order, down to the LSB. The left channel is transferred
first when the DFS is high, and the right channel is
transferred when the DFS is low.
In DSP mode, the DFS becomes a pulse with a width of
1DCLK period. The left channel is transferred first,
followed right away by the right channel. There are two
options in transferring the digital audio data in DSP
mode: the MSB of the left channel can be transferred on
the first rising edge of DCLK following the DFS pulse or
on the second rising edge.
In all audio formats, depending on the word size, DCLK
frequency and sample rates, there may be unused
DCLK cycles after the LSB of each word before the next
DFS transition and MSB of the next word. In addition, if
preferred, the user can configure the MSB to be
captured on the falling edge of DCLK via properties.
The number of audio bits can be configured for 8, 16,
20, or 24 bits.
20
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5.6.2. Audio Sample Rates
The device supports a number of industry-standard sampling rates including 32, 40, 44.1, and 48 kHz. The digital
audio interface enables low-power operation by eliminating the need for redundant DACs on the audio baseband
processor.
(OFALL = 1)
INVERTED
DCLK
(OFALL = 0)
DCLK
LEFT CHANNEL
DFS
I2S
(OMODE = 0000)
RIGHT CHANNEL
1 DCLK
DOUT
1 DCLK
1
2
n-2
3
n-1
MSB
n
1
LSB
MSB
2
n-2
3
n-1
n
LSB
Figure 10. I2S Digital Audio Format
(OFALL = 1)
INVERTED
DCLK
(OFALL = 0)
DCLK
DFS
LEFT CHANNEL
RIGHT CHANNEL
Left-Justified
(OMODE = 0110)
1
DOUT
2
3
n-2
n-1
MSB
n
1
LSB
MSB
2
n-2
3
n-1
n
LSB
Figure 11. Left-Justified Digital Audio Format
(OFALL = 0)
DCLK
DFS
RIGHT CHANNEL
LEFT CHANNEL
(OMODE = 1100)
DOUT
(MSB at 1 rising edge)
1
st
2
3
n-2
n-1
MSB
(OMODE = 1000)
1
LSB
MSB
n-1
n
1
LSB
MSB
2
3
n-2
1
MSB
2
3
n-2
n-1
n
LSB
LEFT CHANNEL
1 DCLK
DOUT
(MSB at 2 rising edge)
nd
n
RIGHT CHANNEL
2
3
n-2
n-1
n
LSB
Figure 12. DSP Digital Audio Format
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
21
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5.7. Stereo Audio Processing
Modulation Level
The output of the FM demodulator is a stereo
multiplexed (MPX) signal. The MPX standard was
developed in 1961, and is used worldwide. Today's
MPX signal format consists of left + right (L+R) audio,
left – right (L–R) audio, a 19 kHz pilot tone, and
RDS/RBDS data as shown in Figure 13 below.
various regions. The de-emphasis time constant is
programmable to 50 or 75 µs and is set by the
FM_DEEMPHASIS property.
5.9. Stereo DAC
High-fidelity stereo digital-to-analog converters (DACs)
drive analog audio signals onto the LOUT and ROUT
pins. The audio output may be muted. Volume is
adjusted digitally with the RX_VOLUME property.
5.10. Soft Mute
Mono Audio
Left + Right
0
Stereo
Pilot
15 19 23
Stereo Audio
Left - Right
38
RDS/
RBDS
53
57
Frequency (kHz)
Figure 13. MPX Signal Spectrum
5.7.1. Stereo Decoder
The Si4736/37/38/39's integrated stereo decoder
automatically decodes the MPX signal using DSP
techniques. The 0 to 15 kHz (L+R) signal is the mono
output of the FM tuner. Stereo is generated from the
(L+R), (L–R), and a 19 kHz pilot tone. The pilot tone is
used as a reference to recover the (L–R) signal. Output
left and right channels are obtained by adding and
subtracting the (L+R) and (L–R) signals respectively.
The Si4731 uses frequency information from the 19 kHz
stereo pilot to recover the 57 kHz RDS/RBDS signal.
5.7.2. Stereo-Mono Blending
Adaptive noise suppression is employed to gradually
combine the stereo left and right audio channels to a
mono (L+R) audio signal as the signal quality degrades
to maintain optimum sound fidelity under varying
reception conditions. Stereo/mono status can be
monitored with the FM_RSQ_STATUS command. Mono
operation
can
be
forced
with
the
FM_BLEND_MONO_THRESHOLD property.
5.8. De-emphasis
Pre-emphasis and de-emphasis is a technique used by
FM broadcasters to improve the signal-to-noise ratio of
FM receivers by reducing the effects of high-frequency
interference and noise. When the FM signal is
transmitted, a pre-emphasis filter is applied to
accentuate the high audio frequencies. The
Si4736/37/38/39 incorporates a de-emphasis filter
which attenuates high frequencies to restore a flat
frequency response. Two time constants are used in
The soft mute feature is available to attenuate the audio
outputs and minimize audible noise in very weak signal
conditions. The softmute attenuation level is adjustable
using the FM_SOFT_MUTE_MAX_ATTENUATION and
AM_SOFT_MUTE_MAX_ATTENUATION properties.
5.11. RDS/RBDS Processor
(Si4737/39 Only)
The Si4737/39 implements an RDS/RBDS* processor
for symbol decoding, block synchronization, error
detection, and error correction.
The Si4737/39 device is user configurable and provides
an optional interrupt when RDS is synchronized, loses
synchronization, and/or the user configurable RDS
FIFO threshold has been met.
The Si4737/39 reports RDS decoder synchronization
status and detailed bit errors in the information word for
each RDS block with the FM_RDS_STATUS command.
The range of reportable block errors is 0, 1–2, 3–5, or
6+. More than six errors indicates that the
corresponding block information word contains six or
more non-correctable errors or that the block checkword
contains errors.
*Note: RDS/RBDS is referred to only as RDS throughout the
remainder of this document.
5.12. Tuning
The tuning frequency is directly programmed using the
FM_TUNE_FREQ, WB_TUNE_FREQ, and
AM_TUNE_FREQ commands. The Si4736/37/38/39
supports channel spacing steps of 10 kHz in FM mode,
25 kHz in WB mode, and 1 kHz in AM mode.
22
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5.13. Seek
Seek tuning will search up or down for a valid channel.
Valid channels are found when the receive signal
strength indicator (RSSI) and the signal-to-noise ratio
(SNR) values exceed the set threshold. Using the SNR
qualifier rather than solely relying on the more
traditional RSSI qualifier can reduce false stops and
increase the number of valid stations detected. Seek is
initiated
using
the
FM_SEEK_START
and
AM_SEEK_START commands. The RSSI and SNR
threshold settings are adjustable using properties (see
Table 16).
5.14. Reference Clock
The Si4736/37/38/39 reference clock is programmable,
supporting RCLK frequencies in Table 13. Refer to
Table 3, “DC Characteristics,” on page 4 for switching
voltage
levels
and
Table 9,
“FM
Receiver
Characteristics,” on page 11 for frequency tolerance
information.
An onboard crystal oscillator is available to generate the
32.768 kHz reference when an external crystal and load
capacitors are provided. Refer to "2. Typical Application
Schematic (QFN)" on page 16. This mode is enabled
using the POWER_UP command. Refer to Table 15,
“Selected Si473x Commands,” on page 26.
The Si4736/37/38/39 performance may be affected by
data activity on the SDIO bus when using the integrated
internal oscillator. SDIO activity results from polling the
tuner for status or communicating with other devices
that share the SDIO bus. If there is SDIO bus activity
while the Si4736/37/38/39 is performing the seek/tune
function, the crystal oscillator may experience jitter,
which may result in mistunes, false stops, and/or lower
SNR.
For best seek/tune results, Skyworks recommends that
all SDIO data traffic be suspended during
Si4736/37/38/39 seek and tune operations. This is
achieved by keeping the bus quiet for all other devices
on the bus, and delaying tuner polling until the tune or
seek operation is complete. The seek/tune complete
(STC) interrupt should be used instead of polling to
determine when a seek/tune operation is complete.
5.15. Control Interface
A serial port slave interface is provided, which allows an
external controller to send commands to the
Si4736/37/38/39 and receive responses from the
device. The serial port can operate in three bus modes:
2-wire mode, 3-wire mode, or SPI mode. The
Si4736/37/38/39 selects the bus mode by sampling the
state of the GPO1 and GPO2 pins on the rising edge of
RST. The GPO1 pin includes an internal pull-up resistor,
which is connected while RST is low, and the GPO2 pin
includes an internal pull-down resistor, which is
connected while RST is low. Therefore, it is only
necessary for the user to actively drive pins which differ
from these states. See Table 14.
Table 14. Bus Mode Select on Rising Edge of
RST
Bus Mode
GPO1
GPO2
2-Wire
1
0
SPI
1
1 (must drive)
3-Wire
0 (must drive)
0
After the rising edge of RST, the pins GPO1 and GPO2
are used as general purpose output (O) pins, as
described in Section “5.16. GPO Outputs”. In any bus
mode, commands may only be sent after VIO and VDD
supplies are applied.
In any bus mode, before sending a command or reading
a response, the user must first read the status byte to
ensure that the device is ready (CTS bit is high).
5.15.1. 2-Wire Control Interface Mode
When selecting 2-wire mode, the user must ensure that
SCLK is high during the rising edge of RST, and stays
high until after the first start condition. Also, a start
condition must not occur within 300 ns before the rising
edge of RST.
The 2-wire bus mode uses only the SCLK and SDIO
pins for signaling. A transaction begins with the START
condition, which occurs when SDIO falls while SCLK is
high. Next, the user drives an 8-bit control word serially
on SDIO, which is captured by the device on rising
edges of SCLK. The control word consists of a 7-bit
device address, followed by a read/write bit (read = 1,
write = 0). The Si4736/37/38/39 acknowledges the
control word by driving SDIO low on the next falling
edge of SCLK.
Although the Si4736/37/38/39 will respond to only a
single device address, this address can be changed
with the SEN pin (note that the SEN pin is not used for
signaling in 2-wire mode). When SEN = 0, the 7-bit
device address is 0010001b. When SEN = 1, the
address is 1100011b.
For write operations, the user then sends an 8-bit data
byte on SDIO, which is captured by the device on rising
edges of SCLK. The Si4736/37/38/39 acknowledges
each data byte by driving SDIO low for one cycle, on the
next falling edge of SCLK. The user may write up to 8
data bytes in a single 2-wire transaction. The first byte is
a command, and the next seven bytes are arguments.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
23
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
For read operations, after the Si4736/37/38/39 has
acknowledged the control byte, it will drive an 8-bit data
byte on SDIO, changing the state of SDIO on the falling
edge of SCLK. The user acknowledges each data byte
by driving SDIO low for one cycle, on the next falling
edge of SCLK. If a data byte is not acknowledged, the
transaction will end. The user may read up to 16 data
bytes in a single 2-wire transaction. These bytes contain
the response data from the Si4736/37/38/39.
A 2-wire transaction ends with the STOP condition,
which occurs when SDIO rises while SCLK is high.
For details on timing specifications and diagrams, refer
to Table 5, “2-Wire Control Interface Characteristics” on
page 6; Figure 2, “2-Wire Control Interface Read and
Write Timing Parameters,” on page 7, and Figure 3, “2Wire Control Interface Read and Write Timing Diagram,”
on page 7.
5.15.2. 3-Wire Control Interface Mode
When selecting 3-wire mode, the user must ensure that
a rising edge of SCLK does not occur within 300 ns
before the rising edge of RST.
The 3-wire bus mode uses the SCLK, SDIO, and SEN_
pins. A transaction begins when the user drives SEN
low. Next, the user drives a 9-bit control word on SDIO,
which is captured by the device on rising edges of
SCLK. The control word consists of a 9-bit device
address (A7:A5 = 101b), a read/write bit (read = 1, write
= 0), and a 5-bit register address (A4:A0).
For write operations, the control word is followed by a
16-bit data word, which is captured by the device on
rising edges of SCLK.
For read operations, the control word is followed by a
delay of one-half SCLK cycle for bus turn-around. Next,
the Si4736/37/38/39 will drive the 16-bit read data word
serially on SDIO, changing the state of SDIO on each
rising edge of SCLK.
A transaction ends when the user sets SEN high, then
pulses SCLK high and low one final time. SCLK may
either stop or continue to toggle while SEN is high.
5.15.3. SPI Control Interface Mode
When selecting SPI mode, the user must ensure that a
rising edge of SCLK does not occur within 300 ns
before the rising edge of RST.
SPI bus mode uses the SCLK, SDIO, and SEN pins for
read/write operations. The system controller can
choose to receive read data from the device on either
SDIO or GPO1. A transaction begins when the system
controller drives SEN = 0. The system controller then
pulses SCLK eight times, while driving an 8-bit control
byte serially on SDIO. The device captures the data on
rising edges of SCLK. The control byte must have one
of five values:
0x48 = write a command (controller drives 8
additional bytes on SDIO).
0x80 = read a response (device drives 1additional
byte on SDIO).
0xC0 = read a response (device drives 16 additional
bytes on SDIO).
0xA0 = read a response (device drives 1 additional
byte on GPO1).
0xE0 = read a response (device drives 16 additional
bytes on GPO1).
For write operations, the system controller must drive
exactly 8 data bytes (a command and seven
arguments) on SDIO after the control byte. The data is
captured by the device on the rising edge of SCLK.
For read operations, the controller must read exactly 1
byte (STATUS) after the control byte or exactly 16 data
bytes (STATUS and RESP1–RESP15) after the control
byte. The device changes the state of SDIO (or GPO1,
if specified) on the falling edge of SCLK. Data must be
captured by the system controller on the rising edge of
SCLK.
Keep SEN low until all bytes have transferred. A
transaction may be aborted at any time by setting SEN
high and toggling SCLK high and then low. Commands
will be ignored by the device if the transaction is
aborted.
In 3-wire mode, commands are sent by first writing each
argument to register(s) 0xA1–0xA3, then writing the
command word to register 0xA0. A response is
retrieved by reading registers 0xA8–0xAF.
For details on timing specifications and diagrams, refer
to Figure 6 and Figure 7 on page 9.
For details on timing specifications and diagrams, refer
to Table 6, “3-Wire Control Interface Characteristics,” on
page 8; Figure 4, “3-Wire Control Interface Write Timing
Parameters,” on page 8, and Figure 5, “3-Wire Control
Interface Read Timing Parameters,” on page 8.
The Si4736/37/38/39 provides three general-purpose
output pins. The GPO pins can be configured to output
a constant low, constant high, or high-impedance. The
GPO pins can be reconfigured as specialized functions.
GPO2/INT can be configured to provide interrupts and
GPO3 can be configured to provide external crystal
support or as DCLK in digital audio output mode.
5.16. GPO Outputs
24
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
5.17. Firmware Upgrades
5.19. Programming with Commands
The Si4736/37/38/39 contains on-chip program RAM to
accommodate minor changes to the firmware. This
allows Skyworks to provide future firmware updates to
optimize the characteristics of new radio designs and
those already deployed in the field.
To ease development time and offer maximum
customization, the Si4736/37/38/39 provides a simple
yet powerful software interface to program the receiver.
The device is programmed using commands,
arguments, properties, and responses.
5.18. Reset, Powerup, and Powerdown
To perform an action, the user writes a command byte
and associated arguments, causing the chip to execute
the given command. Commands control an action such
as powerup the device, shut down the device, or tune to
a station. Arguments are specific to a given command
and are used to modify the command. A partial list of
commands is available in Table 15, “Selected Si473x
Commands,” on page 26.
Setting the RST pin low will disable analog and digital
circuitry, reset the registers to their default settings, and
disable the bus. Setting the RST pin high will bring the
device out of reset.
A powerdown mode is available to reduce power
consumption when the part is idle. Putting the device in
powerdown mode will disable analog and digital circuitry
while keeping the bus active.
Properties are a special command argument used to
modify the default chip operation and are generally
configured immediately after powerup. Examples of
properties are de-emphasis level, RSSI seek threshold,
and soft mute attenuation threshold. A partial list of
properties is available in Table 16, “Selected Si473x
Properties,” on page 27.
Responses provide the user information and are
echoed after a command and associated arguments are
issued. All commands provide a 1-byte status update,
indicating interrupt and clear-to-send status information.
For a detailed description of the commands and
properties for the Si4736/37/38/39, see “AN332: Si47xx
Programming Guide.”
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
25
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
6. Commands and Properties
Table 15. Selected Si473x Commands
Cmd
Name
Description
0x01
POWER_UP
0x10
GET_REV
0x11
POWER_DOWN
Powerdown device.
0x12
SET_PROPERTY
Sets the value of a property.
0x13
GET_PROPERTY
Retrieves a property’s value.
0x20
FM_TUNE_FREQ
Selects the FM tuning frequency.
0x21
FM_SEEK_START
Begins searching for a valid frequency.
0x23
FM_RSQ_STATUS
Queries the status of the Received Signal Quality (RSQ) of the current
channel.
0x24
FM_RDS_STATUS
Returns RDS information for current channel and reads an entry from the RDS FIFO
(Si4731 only).
0x40
AM_TUNE_FREQ
Selects the AM tuning frequency.
0x41
AM_SEEK_START
Begins searching for a valid frequency.
0x43
AM_RSQ_STATUS
Queries the status of the RSQ of the current channel.
0x50
WB_TUNE_FREQ
Selects the WB tuning frequency.
0x53
WB_RSQ_STATUS
Queries the status of the RSQ of the current channel.
Powerup device and mode selection. Modes include AM or FM receive, analog or
digital output, and reference clock or crystal support.
Returns revision information on the device.
26
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 16. Selected Si473x Properties
Prop
Name
0x1100
FM_DEEMPHASIS
0x1105
Description
Default
Sets de-emphasis time constant. Default is 75 µs.
0x0002
FM_BLEND_STEREO_
THRESHOLD
Sets RSSI threshold for stereo blend (full stereo above threshold, blend
below threshold). To force stereo set this to 0. To force mono set this to
127. Default value is 49 dBµV.
0x0031
0x1106
FM_BLEND_MONO_
THRESHOLD
Sets RSSI threshold for mono blend (full mono below threshold, blend
above threshold). To force stereo, set this to 0. To force mono, set this
to 127. Default value is 30 dBµV.
0x001E
0x1200
FM_RSQ_INT_
SOURCE
Configures interrupt related to RSQ metrics.
0x0000
0x1300
FM_SOFT_MUTE_RATE
Sets the attack and decay rates when entering and leaving soft mute.
0x0040
0x1302
FM_SOFT_MUTE_
MAX_ATTENUATION
Sets maximum attenuation during soft mute (dB). Set to 0 to disable
soft mute. Default is 16 dB.
0x0010
0x1303
FM_SOFT_MUTE_
SNR_THRESHOLD
Sets SNR threshold to engage soft mute. Default is 4 dB.
0x0004
0x1400
FM_SEEK_BAND_
BOTTOM
Sets the bottom of the FM band for seek. Default is 8750.
0x222E
0x1401
FM_SEEK_BAND_TOP
Sets the top of the FM band for seek. Default is 10790.
0x2A26
0x1402
FM_SEEK_FREQ_
SPACING
Selects frequency spacing for FM seek.
0x000A
0x1403
FM_SEEK_TUNE_
SNR_THRESHOLD
Sets the SNR threshold for a valid FM Seek/Tune. Default value is
3 dB.
0x0003
0x1404
FM_SEEK_TUNE_
RSSI_TRESHOLD
Sets the RSSI threshold for a valid FM Seek/Tune. Default value is
20 dBuV.
0x0014
0x1500
RDS_INT_SOURCE
Configures RDS interrupt behavior.
0x0000
0x1501
RDS_INT_FIFO_COUNT
Sets the minimum number of RDS groups stored in the receive RDS
FIFO required before RDS RECV is set.
0x0000
0x1502
RDS_CONFIG
Configures RDS setting.
0x0000
0x3100
AM_DEEMPHASIS
Sets de-emphasis time constant. Can be set to 50 us. De-emphasis is
disabled by default.
0x0000
0x3102
AM_CHANNEL_FILTER
Selects the bandwidth of the channel filter for AM reception. The
choices are 6, 4, 3, 2.5, 2, 1.8, or 1 kHz. In addition, a power line rejection filter can be applied. The default is the 2 kHz bandwidth filter without power line rejection.
0x0003
0x3103
AM_AUTOMATIC_VOLUME_CONTROL_MAX_GAIN
Selects the maximum gain for automatic volume control.
0x1543
0x3200
AM_RSQ_INTERRUPTS
Configures interrupt related to RSQ metrics. All interrupts are disabled
by default.
0x0000
0x3300
AM_SOFT_MUTE_RATE
Sets the rate of attack when entering or leaving soft mute. The default
is 278 dB/s.
0x0040
0x3302
AM_SOFT_MUTE_MAX_
ATTENUATION
Sets maximum attenuation during soft mute (dB).
0x0008
0x3303
AM_SOFT_MUTE_SNR_
THRESHOLD
Sets SNR threshold to engage soft mute. Default is 0 dB, which disables soft mute.
0x0008
0x3400
AM_SEEK_BAND_
BOTTOM
Sets the bottom of the AM band for seek. Default is 520.
0x0208
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
27
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 16. Selected Si473x Properties (Continued)
Prop
Name
0x3401
AM_SEEK_BAND_TOP
0x3402
AM_SEEK_FREQ_
SPACING
0x3403
Description
Default
Sets the top of the AM band for seek.
0x06AE
Selects frequency spacing for AM seek. Default is 10 kHz spacing.
0x000A
AM_SEEK_SNR_
THRESHOLD
Sets the SNR threshold for a valid AM Seek/Tune. If the value is zero,
then SNR threshold is not considered when doing a seek. Default value
is 5 dB.
0x0005
0x3404
AM_SEEK_RSSI_
THRESHOLD
Sets the RSSI threshold for a valid AM Seek/Tune. If the value is zero,
then RSSI threshold is not considered when doing a seek. Default
value is 25 dBuV.
0x0019
0x4000
RX_VOLUME
Sets the output volume.
0x003F
0x4001
RX_HARD_MUTE
Mutes the audio output. L and R audio outputs may be muted independently in FM mode.
0x0000
0x5108
WB_MAX_TUNE_ERROR
Maximum change in frequencies from the WB_TUNE_FREQ to which
the AFC will lock.
0x000F
0x5200
WB_RSQ_INTERRUPT_
SOURCE
Configures interrupts related to RSQ metrics. All interrupts are disabled
by default.
0x0000
0x5600
WB_ASQ_INTERRUPT_
SOURCE
Configures 1050 Hz alert tone interrupts. All interrupts are disabled by
default.
0x0000
28
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
GPO2/INT
GPO3/DCLK
DFS
1
GPO1
NC
NC
7. Pin Descriptions: Si4736/37/38/39-GM
20
19
18
17
16
FMI 2
15 DOUT
RFGND 3
14 LOUT
GND
PAD
AMI 4
13 ROUT
6
7
8
9
10
SCLK
SDIO
RCLK
VIO
12 GND
SEN
RST 5
11 VDD
Pin Number(s)
Name
Description
1, 20
NC
No connect. Leave floating.
2
FMI
FM/WB RF inputs. FMI should be connected to the antenna trace.
3
RFGND
4
AMI
AM RF input. AMI should be connected to the AM antenna.
5
RST
Device reset (active low) input.
6
SEN
Serial enable input (active low).
7
SCLK
Serial clock input.
8
SDIO
Serial data input/output.
9
RCLK
External reference oscillator input.
10
VIO
I/O supply voltage.
11
VDD
Supply voltage. May be connected directly to battery.
12, GND PAD
GND
Ground. Connect to ground plane on PCB.
13
ROUT
Right audio line output in analog output mode.
14
LOUT
Left audio line output in analog output mode.
15
DOUT
Digital output data in digital output mode.
16
DFS
17
GPO3/DCLK
18
GPO2/INT
19
GPO1
RF ground. Connect to ground plane on PCB.
Digital frame synchronization input in digital output mode.
General purpose output, crystal oscillator, or digital bit synchronous clock input in digital
output mode.
General purpose output or interrupt pin.
General purpose output.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
29
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
8. Pin Descriptions: Si4736/37-GU
DOUT
1
24
LOUT
DFS
2
23
ROUT
GPO3/DCLK
3
22
DBYP
GPO2/INT
4
21
VDD
GPO1
5
20
VIO
NC
6
19
RCLK
NC
7
18
SDIO
FMI
8
17
SCLK
RFGND
9
16
SEN
NC
10
15
RST
NC
11
14
GND
AMI
12
13
GND
Pin Number(s)
Name
Description
1
DOUT
2
DFS
3
GPO3/DCLK
4
GPO2/INT
5
GPO1
6,7
NC
No connect. Leave floating.
8
FMI
FM/WB RF inputs. FMI should be connected to the antenna trace.
9
RFGND
10,11
NC
Unused. Tie these pins to GND.
12
AMI
AM RF input. AMI should be connected to the AM antenna.
13,14
GND
Ground. Connect to ground plane on PCB.
15
RST
Device reset (active low) input.
16
SEN
Serial enable input (active low).
17
SCLK
Serial clock input.
18
SDIO
Serial data input/output.
19
RCLK
External reference oscillator input.
20
VIO
I/O supply voltage.
21
VDD
Supply voltage. May be connected directly to battery.
22
DBYP
Dedicated bypass for VDD and VIO.
23
ROUT
Right audio line output in analog output mode.
24
LOUT
Left audio line output in analog output mode.
Digital output data in digital output mode.
Digital frame synchronization input in digital output mode.
General purpose output, crystal oscillator, or digital bit synchronous clock input in digital
output mode.
General purpose output or interrupt pin.
General purpose output.
RF ground. Connect to ground plane on PCB.
30
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
9. Ordering Guide
Part Number*
Description
Package
Type
Operating
Temperature/Voltage
Si4736-C40-GM
AM/FM/WB Broadcast Radio Receiver
QFN
Pb-free
–20 to 85 °C
2.7 to 5.5 V
Si4736-C40-GU
AM/FM/WB Broadcast Radio Receiver
SSOP
Pb-free
–20 to 85 °C
2.0 to 5.5 V
Si4737-C40-GM
AM/FM/WB Broadcast Radio Receiver with
RDS/RBDS
QFN
Pb-free
–20 to 85 °C
2.7 to 5.5 V
Si4737-C40-GU
AM/FM/WB Broadcast Radio Receiver with
RDS/RBDS
SSOP
Pb-free
–20 to 85 °C
2.0 to 5.5 V
Si4738-C40-GM
FM/WB Broadcast Radio Receiver
QFN
Pb-free
–20 to 85 °C
2.7 to 5.5 V
Si4739-C40-GM
FM/WB Broadcast Radio Receiver with RDS/RBDS
QFN
Pb-free
–20 to 85 °C
2.7 to 5.5 V
*Note: Add an “(R)” at the end of the device part number to denote tape and reel option; 2500 quantity per reel. SSOP
devices operate down to VDD = 2 V at 25 °C.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
31
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
10. Package Markings (Top Marks)
10.1. Si4736/37/38/39 Top Mark (QFN)
3640
CTTT
YWW
3740
CTTT
YWW
3840
CTTT
YWW
3940
CTTT
YWW
10.2. Top Mark Explanation (QFN)
Mark Method:
YAG Laser
Line 1 Marking:
Part Number
36 = Si4736, 37 = Si4737, 38 = Si4738, 39 = Si4739
Firmware Revision
40 = Firmware Revision 4.0
Die Revision
C = Revision C Die
TTT = Internal Code
Internal tracking code
Circle = 0.5 mm Diameter
(Bottom-Left Justified)
Pin 1 Identifier
Y = Year
WW = Workweek
Assigned by the Assembly House. Corresponds to the last significant
digit of the year and workweek of the mold date.
Line 2 Marking:
Line 3 Marking:
32
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
10.3. Si4736/37 Top Mark (SSOP)
4736C40GU
YYWWTTTTTT
10.4. Top Mark Explanation (SSOP)
Mark Method:
Line 1 Marking:
Line 2 Marking:
YAG Laser
Part Number
4736 = Si4736; 4737 = Si4737.
Die Revision
C = Revision C die.
Firmware Revision
40 = Firmware Revision 4.0.
YY = Year
WW = Work week
TTTTTT = Manufacturing code
Assigned by the Assembly House.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
33
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
11. Package Outline: Si4736/37/38/39 QFN
Figure 14 illustrates the package details for the Si4736/37/38/39. Table 17 lists the values for the dimensions
shown in the illustration.
Figure 14. 20-Pin Quad Flat No-Lead (QFN)
Table 17. Package Dimensions
Symbol
Millimeters
Symbol
Millimeters
Min
Nom
Max
A
0.50
0.55
0.60
f
A1
0.00
0.02
0.05
L
0.35
0.40
0.45
b
0.20
0.25
0.30
L1
0.00
—
0.10
c
0.27
0.32
0.37
aaa
—
—
0.05
bbb
—
—
0.05
ccc
—
—
0.08
D
D2
3.00 BSC
1.65
1.70
1.75
Min
Nom
Max
2.53 BSC
e
0.50 BSC
ddd
—
—
0.10
E
3.00 BSC
eee
—
—
0.10
E2
1.65
1.70
1.75
Notes:
1. All dimensions are shown in millimeters (mm) unless otherwise noted.
2. Dimensioning and tolerancing per ANSI Y14.5M-1994.
34
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
12. PCB Land Pattern: Si4736/37/38/39 QFN
Figure 15 illustrates the PCB land pattern details for the Si4736/37/38/39-C40-GM QFN. Table 18 lists the values
for the dimensions shown in the illustration.
Figure 15. PCB Land Pattern
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
35
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
Table 18. PCB Land Pattern Dimensions
Symbol
Millimeters
Min
D
D2
Symbol
Max
2.71 REF
1.60
1.80
Min
Max
GE
2.10
—
W
—
0.34
—
0.28
e
0.50 BSC
X
E
2.71 REF
Y
E2
1.60
f
GD
1.80
2.53 BSC
2.10
Millimeters
0.61 REF
ZE
—
3.31
ZD
—
3.31
—
Notes: General
1. All dimensions shown are in millimeters (mm) unless otherwise noted.
2. Dimensioning and Tolerancing is per the ANSI Y14.5M-1994 specification.
3. This Land Pattern Design is based on IPC-SM-782 guidelines.
4. All dimensions shown are at Maximum Material Condition (MMC). Least Material
Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm.
Notes: Solder Mask Design
1. All metal pads are to be non-solder mask defined (NSMD). Clearance between the
solder mask and the metal pad is to be 60 µm minimum, all the way around the pad.
Notes: Stencil Design
1. A stainless steel, laser-cut, and electro-polished stencil with trapezoidal walls should
be used to assure good solder paste release.
2. The stencil thickness should be 0.125 mm (5 mils).
3. The ratio of stencil aperture to land pad size should be 1:1 for the perimeter pads.
4. A 1.45 x 1.45 mm square aperture should be used for the center pad. This provides
approximately 70% solder paste coverage on the pad, which is optimum to assure
correct component stand-off.
Notes: Card Assembly
1. A No-Clean, Type-3 solder paste is recommended.
2. The recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification
for Small Body Components.
36
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
13. Package Outline: Si4736/37 SSOP
Figure 16 illustrates the package details for the Si4736/37. Table 19 lists the values for the dimensions shown in
the illustration.
Figure 16. 24-Pin SSOP
Table 19. Package Dimensions
Dimension
Min
Nom
Max
A
—
—
1.75
A1
0.10
—
0.25
b
0.20
—
0.30
c
0.10
—
0.25
D
8.65 BSC
E
6.00 BSC
E1
3.90 BSC
e
0.635 BSC
L
0.40
L2
θ
—
1.27
0.25 BSC
0°
—
aaa
0.20
bbb
0.18
ccc
0.10
ddd
0.10
8°
Notes:
1. All dimensions shown are in millimeters (mm) unless otherwise noted.
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.
3. This drawing conforms to the JEDEC Solid State Outline MO-137, Variation AE.
4. Recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification
for Small Body Components.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
37
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
14. PCB Land Pattern: Si4736/37 SSOP
Figure 17 illustrates the PCB land pattern details for the Si4736/37-C40-GU SSOP. Table 20 lists the values for the
dimensions shown in the illustration.
Figure 17. PCB Land Pattern
Table 20. PCB Land Pattern Dimensions
Dimension
Min
Max
C
5.20
5.40
E
0.65 BSC
X1
0.35
0.45
Y1
1.55
1.75
General:
1. All dimensions shown are in millimeters (mm) unless otherwise noted.
2. This land pattern design is based on the IPC-7351 guidelines.
Solder Mask Design:
3. All metal pads are to be non-solder mask defined (NSMD). Clearance between
the solder mask and the metal pad is to be 60 µm minimum, all the way around
the pad.
Stencil Design:
4. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls
should be used to assure good solder paste release.
5. The stencil thickness should be 0.125 mm (5 mils).
6. The ratio of stencil aperture to land pad size should be 1:1 for all perimeter pads.
Card Assembly:
7. A No-Clean, Type-3 solder paste is recommended.
8. The recommended card reflow profile is per the JEDEC/IPC J-STD-020
specification for Small Body Components.
38
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
15. Additional Reference Resources
Contact your local sales representatives for more information or to obtain copies of the following references:
AN332: Si47xx Programming Guide
AN383: Si47xx Antenna, Schematic, Layout, and Design Guidelines
AN388: Si470x/1x/2x/3x/4x Evaluation Board Test Procedure
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
39
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Si4736/37/38/39-C40
DOCUMENT CHANGE LIST
Revision 0.71 to Revision 1.0
Updated patent information on page 1.
Pin 22 changed from “GND” to “DBYP.”
Updated Table 1 on page 3.
Updated Table 3 on page 4.
Updated Table 12 on page 14.
Updated "3. Typical Application Schematic (SSOP)" on page 17.
Updated "4. Bill of Materials (QFN/SSOP)" on page 18.
Updated "8. Pin Descriptions: Si4736/37-GU" on page 30.
Updated "9. Ordering Guide" on page 31.
40
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 1, 2021
Connecting Everyone
and Everything,
All the Time
Portfolio
Quality
Support & Resources
www.skyworksinc.com
www.skyworksinc.com/quality
www.skyworksinc.com/support
Copyright © 2021 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the
information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer.
Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation,
products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or
information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability
for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or
materials, except as may be provided in Skyworks’ Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR
OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR
COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR
ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT
OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks
products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such
applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of
design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating
safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any
equipment resulting from the use of Skyworks products outside of Skyworks’ published specifications or parameters.
Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or
registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for
identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at
www.skyworksinc.com, are incorporated by reference.
Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com
USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540 |