0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SI53119-A01AGMR

SI53119-A01AGMR

  • 厂商:

    SILABS(芯科科技)

  • 封装:

    VFQFN-72

  • 描述:

    IC BUFFER ZDB PCIE 1:19 72-QFN

  • 数据手册
  • 价格&库存
SI53119-A01AGMR 数据手册
S i 5 3 119 19-O UTPUT P C I E G EN 3 BUFFER Features Applications Server  Storage  Data center  Enterprise switches and routers  Description The Si53119 is a 19-output, low-power HCSL differential clock buffer that meets all of the performance requirements of the Intel DB1200ZL specification. The device is optimized for distributing reference clocks for Intel® QuickPath Interconnect (Intel QPI), PCIe Gen 1/Gen 2/Gen 3/Gen 4, SAS, SATA, and Intel Scalable Memory Interconnect (Intel SMI) applications. The VCO of the device is optimized to support 100 MHz and 133 MHz operation. Each differential output can be enabled through I2C for maximum flexibility and power savings. Measuring PCIe clock jitter is quick and easy with the Skyworks Solutions PCIe Clock Jitter Tool. Download it for free at https://www.skyworksinc.com/en/application-pages/pciexpress-learning-center. GND VDD_IO Pin Assignments DIF_13 DIF_13 DIF_14 DIF_14  54 53 52 51 50 49 VDDA GNDA 100M_133M HBW_BYPASS_LBW PWRGD / PWRDN GND VDDR CLK_IN CLK_IN SA_0 SDA SCL SA_1 FBOUT_NC FBOUT_NC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 GND 16 DIF_0 17 DIF_0 18 48 47 46 45 44 43 42 41 40 39 38 37 Si53119 33 34 35 36  VDD_IO GND DIF_6 DIF_6  Ordering Information: See page 31. VDD GND DIF_15 DIF_15  GND VDD DIF_4 DIF_4 DIF_5 DIF_5  DIF_17 DIF_17 DIF_16 DIF_16  68 67 66 65 64 63 62 61 60 59 58 57 56 55  DIF_18 DIF_18 GND VDD_IO   72 71 70 69   PLL or bypass mode Spread spectrum tolerable 1.05 to 3.3 V I/O supply voltage 50 ps output-to-output skew 50 ps cyc-cyc jitter (PLL mode) Low phase jitter (Intel QPI, PCIe Gen 1/2/3 common clock compliant) Gen 3 SRNS Compliant 100 ps input-to-output delay Extended Temperature: –40 to 85 °C 72-pin QFN For variations of this device, contact Skyworks Solutions GND DIF_2 DIF_2 DIF_3 DIF_3   19 20 21 22 23 24 25 26 27 28 29 30 31 32   DIF_1 DIF_1  Nineteen 0.7 V low-power, pushpull HCSL PCIe Gen 3 outputs 100 MHz /133 MHz PLL operation, supports PCIe and QPI PLL bandwidth SW SMBUS programming overrides the latch value from HW pin 9 selectable SMBUS addresses SMBus address configurable to allow multiple buffers in a single control network 3.3 V supply voltage operation Separate VDDIO for outputs VDD_IO  DIF_12 DIF_12 VDD_IO GND DIF_11 DIF_11 DIF_10 DIF_10 GND VDD DIF_9 DIF_9 DIF_8 DIF_8 VDD_IO GND DIF_7 DIF_7 Patents pending Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 Functional Block Diagram FB_OUT SSC Compatible PLL CLK_IN DIF_[18:0] CLK_IN 100M_133 HBW_BYPASS_LBW SA_0 SA_1 PWRGD / PWRDN SDA SCL 2 Control Logic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 TA B L E O F C O N T E N T S Section Page 1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1. CLK_IN, CLK_IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.2. 100M_133M—Frequency Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.3. SA_0, SA_1—Address Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.4. CKPWRGD/PWRDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 2.5. HBW_BYPASS_LBW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.6. Miscellaneous Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3. Test and Measurement Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.1. Input Edge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.2. Termination of Differential Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4. Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 4.1. Byte Read/Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 4.2. Block Read/Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.3. Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5. Pin Descriptions: 72-Pin QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6. Power Filtering Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 6.1. Ferrite Bead Power Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 7. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 8. Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 9. Land Pattern: 72-pin QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 3 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 1. Electrical Specifications Table 1. DC Operating Characteristics VDD_A = 3.3 V±5%, VDD = 3.3 V±5% Parameter Symbol Test Condition Min Max Unit VDD/VDD_A 3.3 V ±5% 3.135 3.465 V VDD_IO 1.05 V to 3.3 V ±5% 0.9975 3.465 V 3.3 V Input High Voltage VIH VDD 2.0 VDD+0.3 V 3.3 V Input Low Voltage VIL VSS-0.3 0.8 V 3.3 V Core Supply Voltage 3.3 V I/O Supply Input Leakage Voltage1 Current2 IIL 0 < VIN < VDD –5 +5 µA 3 VIH_FS VDD 0.7 VDD+0.3 V 3 VIL_FS VSS–0.3 0.35 V 3.3 V Input Low Voltage VIL_Tri 0 0.9 V 3.3 V Input Med Voltage VIM_Tri 1.3 1.8 V 3.3 V Input High Voltage VIH_Tri 2.4 VDD V 3.3 V Input High Voltage 3.3 V Input Low Voltage Voltage4 VOH IOH = –1 mA 2.4 — V 3.3 V Output Low Voltage4 VOL IOL = 1 mA — 0.4 V CIN 2.5 4.5 pF COUT 2.5 4.5 pF LPIN — 7 nH –40 85 °C 3.3 V Output High Input Capacitance Output 5 Capacitance5 Pin Inductance Ambient Temperature TA No Airflow Notes: 1. VDD_IO applies to the low-power NMOS push-pull HCSL compatible outputs. 2. Input Leakage Current does not include inputs with pull-up or pull-down resistors. Inputs with resistors should state current requirements. 3. Internal voltage reference is to be used to guarantee VIH_FS and VIL_FS threshold levels over full operating range. 4. Signal edge is required to be monotonic when transitioning through this region. 5. Ccomp capacitance based on pad metallization and silicon device capacitance. Not including pin capacitance. 4 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 Table 2. SMBus Characteristics Parameter Symbol Test Condition Min Max Unit 0.8 V VDDSMB V 0.4 V 5.5 V 1 VILSMB SMBus Input High Voltage1 VIHSMB SMBus Output Low Voltage1 VOLSMB @ IPULLUP Nominal Bus Voltage1 VDDSMB @ VOL 2.7 IPULLUP 3 V to 5 V +/-10% 4 SCLK/SDAT Rise Time1 tRSMB (Max VIL – 0.15) to (Min VIH + 0.15) 1000 ns SCLK/SDAT Fall Time1 tFSMB (Min VIH + 0.15) to (Max VIL – 0.15) 300 ns fMINSMB Minimum Operating Frequency SMBus Input Low Voltage SMBus sink Current1 SMBus Operating Frequency1,2 2.1 mA 100 kHz Notes: 1. Guaranteed by design and characterization 2. The differential input clock must be running for the SMBus to be active Table 3. Current Consumption TA = -40–85 °C; supply voltage VDD = 3.3 V ±5% Parameter Operating Current Power Down Current Symbol Test Condition Min Typ Max Unit IDDVDD 100 MHz, VDD Rail — 25 35 mA IDDVDDA 100 MHz, VDDA + VDDR, PLL Mode — 16 20 mA IDDVDDIO 100 MHz, CL = Full Load, VDD IO Rail — 130 150 mA IDDVDDPD Power Down, VDD Rail — 1.5 2 mA IDDVDDAPD Power Down, VDDA Rail — 8 12 mA IDDVDDIOPD Power Down, VDD_IO Rail — 0.17 0.5 mA Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 5 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 Table 4. Clock Input Parameters TA = -40–85 °C; supply voltage VDD = 3.3 V ±5% Parameter Symbol Test Condition Min Typ Max Unit Input High Voltage VIHDIF Differential Inputs (singled-ended measurement) 600 700 1150 mV Input Low Voltage VIHDIF Differential Inputs (singled-ended measurement) Vss300 0 300 mV Input Common Mode Voltage Vcom Common mode input voltage 300 1000 mV Input Amplitude, CLK_IN Vswing Peak to Peak Value 300 1450 mV Input Slew Rate, CLK_IN dv/dt Measured differentially 0.4 8 V/ns Measurement from differential wave form 45 55 % 125 ps 150 MHz Input Duty Cycle 50 Input Jitter–Cycle to Cycle JDFin Differential measurement Input Frequency Fibyp VDD = 3.3 V, bypass mode 33 FiPLL VDD = 3.3 V, 100 MHz PLL Mode 90 100 110 MHz FiPLL VDD = 3.3 V, 133.33 MHz PLL Mode 120 133.33 147 MHz fMODIN Triangle wave modulation 30 31.5 33 kHz Input SS Modulation Rate 6 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 Table 5. Output Skew, PLL Bandwidth and Peaking TA = -40–85 °C; supply voltage VDD = 3.3 V ±5% Parameter Test Condition Min TYP Max Unit CLK_IN, DIF[x:0] Input-to-Output Delay in PLL Mode Nominal Value1,2,3,4 –100 18 100 ps CLK_IN, DIF[x:0] Input-to-Output Delay in Bypass Mode Nominal Value2,4,5 2.5 3.6 4.5 ns CLK_IN, DIF[x:0] Input-to-Output Delay Variation in PLL mode Over Voltage and Temperature2,4,5 –50 20 50 ps CLK_IN, DIF[x:0] Input-to-Output Delay Variation in Bypass Mode Over Voltage and Temperature2,4,5 –250 250 ps DIF[11:0] Output-to-Output Skew across all 19 Outputs (Common to Bypass and PLL Mode)1,2,3,4,5 0 20 50 ps PLL Jitter Peaking (HBW_BYPASS_LBW = 0)6 — 0.4 2.0 dB PLL Jitter Peaking (HBW_BYPASS_LBW = 1)6 — 0.1 2.5 dB PLL Bandwidth (HBW_BYPASS_LBW = 0) 7 — 0.7 1.4 MHz PLL Bandwidth (HBW_BYPASS_LBW = 1)7 — 2 4 MHz Notes: 1. Measured into fixed 2 pF load cap. Input-to-output skew is measured at the first output edge following the corresponding input. 2. Measured from differential cross-point to differential cross-point. 3. This parameter is deterministic for a given device. 4. Measured with scope averaging on to find mean value. 5. All Bypass Mode Input-to-Output specs refer to the timing between an input edge and the specific output edge created by it. 6. Measured as maximum pass band gain. At frequencies within the loop BW, highest point of magnification is called PLL jitter peaking. 7. Measured at 3 db down or half power point. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 7 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 Table 6. Phase Jitter Parameter Phase Jitter PLL Mode Test Condition Min Typ Max Unit — 25 86 ps PCIe Gen 2 Low Band, Common Clock F < 1.5 MHz1,3,4,5 — 2.5 3.0 ps (RMS) PCIe Gen 2 High Band, Common Clock 1.5 MHz < F < Nyquist1,3,4,5 — 2.5 3.1 ps (RMS) PCIe Gen 3, Common Clock (PLL BW 2–4 MHz, CDR = 10 MHz)1,3,4,5 — 0.5 1.0 ps (RMS) PCIe Gen 3 Separate Reference No Spread, SRNS (PLL BW of 2–4 or 2–5 MHz, CDR = 10 MHz)1,3,4,5 — 0.35 0.71 ps (RMS) Intel® QPI & Intel SMI (4.8 Gbps or 6.4 Gb/s, 100 or 133 MHz, 12 UI)1,6,7 — 0.25 0.5 ps (RMS) Intel QPI & Intel SMI (8 Gb/s, 100 MHz, 12 UI)1,6 — 0.15 0.3 ps (RMS) Intel QPI & Intel SMI (9.6 Gb/s, 100 MHz, 12 UI)1,6 — 0.16 0.2 ps (RMS) PCIe Gen 1, Common Clock 1,2,3 Notes: 1. Post processed evaluation through Intel supplied Matlab* scripts. Defined for a BER of 1E-12. Measured values at a smaller sample size have to be extrapolated to this BER target. 2. ζ = 0.54 implies a jitter peaking of 3 dB. 3. PCIe* Gen 3 filter characteristics are subject to final ratification by PCISIG. Check the PCI-SIG for the latest specification. 4. Measured on 100 MHz PCIe output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 5. Measured on 100 MHz output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 6. Measured on 100 MHz, 133 MHz output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 7. These jitter numbers are defined for a BER of 1E-12. Measured numbers at a smaller sample size have to be extrapolated to this BER target. 8. Gen 4 specifications based on the PCI-Express Base Specification 4.0 rev. 0.9. 9. Download the Skyworks Solutions PCIe Clock Jitter Tool at https://www.skyworksinc.com/en/application-pages/pciexpress-learning-center. 8 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 Table 6. Phase Jitter (Continued) Additive Phase Jitter Bypass Mode PCIe Gen 11,2,3 — 10 — ps PCIe Gen 2 Low Band F < 1.5 MHz1,3,4,5 — 1.0 — ps (RMS) PCIe Gen 2 High Band 1.5 MHz < F < Nyquist1,3,4,5 — 1.0 — ps (RMS) PCIe Gen 3 (PLL BW 2–4 MHz, CDR = 10 MHz)1,3,4,5 — 0.3 — ps (RMS) PCIe Gen 4, Common Clock (PLL BW of 2–4 or 2–5 MHz, CDR = 10 MHz)1,4,5,8 — 0.3 — ps (RMS) Intel QPI & Intel® SMI (4.8 Gbps or 6.4 Gb/s, 100 or 133 MHz, 12 UI)1,6,7 — 0.15 — ps (RMS) Intel QPI & Intel® SMI (8 Gb/s, 100 MHz, 12 UI)1,6 — 0.1 — ps (RMS) Intel QPI & Intel® SMI (9.6 Gb/s, 100 MHz, 12 UI)1,6 — 0.1 — ps (RMS) Notes: 1. Post processed evaluation through Intel supplied Matlab* scripts. Defined for a BER of 1E-12. Measured values at a smaller sample size have to be extrapolated to this BER target. 2. ζ = 0.54 implies a jitter peaking of 3 dB. 3. PCIe* Gen 3 filter characteristics are subject to final ratification by PCISIG. Check the PCI-SIG for the latest specification. 4. Measured on 100 MHz PCIe output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 5. Measured on 100 MHz output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 6. Measured on 100 MHz, 133 MHz output using the template file in the Intel-supplied Clock Jitter Tool V1.6.3. 7. These jitter numbers are defined for a BER of 1E-12. Measured numbers at a smaller sample size have to be extrapolated to this BER target. 8. Gen 4 specifications based on the PCI-Express Base Specification 4.0 rev. 0.9. 9. Download the Skyworks Solutions PCIe Clock Jitter Tool at https://www.skyworksinc.com/en/application-pages/pciexpress-learning-center. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 9 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 Table 7. DIF 0.7 V AC Timing Characteristics (Non-Spread Spectrum Mode)1 Parameter Symbol CLK 100 MHz, 133 MHz Min Typ Max Unit Clock Stabilization Time2 TSTAB — 1.5 1.8 ms Long Term Accuracy3,4,5 LACC — — 100 ppm Absolute Host CLK Period (100 MHz)3,4,6 TABS 9.94900 — 10.05100 ns Absolute Host CLK Period (133 MHz)3,4,6 TABS 7.44925 — 7.55075 ns Edge_rate 1.0 3.0 4.0 V/ns Rise Time Variation3,8,9 ∆ Trise — — 125 ps Fall Time Variation3,8,9 ∆ Tfall — — 125 ps TRISE_MAT/ TFALL_MAT — 7 20 % VHIGH 660 750 850 mV Slew Rate3,4,7 Rise/Fall Matching3,8,10,11 Voltage High (typ 0.7 V)3,8,12 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. This is the time from the valid CLK_IN input clocks and the assertion of the PWRGD signal level at 1.8–2.0 V to the time that stable clocks are output from the buffer chip (PLL locked). 3. Test configuration is Rs = 33.2 , 2 pF for 100  transmission line; Rs = 27 , 2 pF for 85  transmission line. 4. Measurement taken from differential waveform. 5. Using frequency counter with the measurement interval equal or greater than 0.15 s, target frequencies are 99,750,00 Hz, 133,000,000 Hz. 6. The average period over any 1 µs period of time must be greater than the minimum and less than the maximum specified period. 7. Measure taken from differential waveform on a component test board. The edge (slew) rate is measured from –150 mV to +150 mV on the differential waveform. Scope is set to average because the scope sample clock is making most of the dynamic wiggles along the clock edge. Only valid for Rising clock and Falling CLOCK. Signal must be monotonic through the Vol to Voh region for Trise and Tfall. 8. Measurement taken from single-ended waveform. 9. Measured with oscilloscope, averaging off, using min max statistics. Variation is the delta between min and max. 10. Measured with oscilloscope, averaging on. The difference between the rising edge rate (average) of clock verses the falling edge rate (average) of CLOCK. 11. Rise/Fall matching is derived using the following, 2*(Trise – Tfall) / (Trise + Tfall). 12. VHigh is defined as the statistical average High value as obtained by using the Oscilloscope VHigh Math function. 13. VLow is defined as the statistical average Low value as obtained by using the Oscilloscope VLow Math function. 14. Measured at crossing point where the instantaneous voltage value of the rising edge of CLK equals the falling edge of CLK. 15. This measurement refers to the total variation from the lowest crossing point to the highest, regardless of which edge is crossing. 16. The crossing point must meet the absolute and relative crossing point specifications simultaneously. 17. Vcross(rel) Min and Max are derived using the following, Vcross(rel) Min = 0.250 + 0.5 (Vhavg – 0.700), Vcross(rel) Max = 0.550 – 0.5 (0.700 – Vhavg), (see Figures 3–4 for further clarification). 18. Vcross is defined as the total variation of all crossing voltages of Rising CLOCK and Falling CLOCK. This is the maximum allowed variance in Vcross for any particular system. 19. Overshoot is defined as the absolute value of the maximum voltage. 20. Undershoot is defined as the absolute value of the minimum voltage. 10 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 Table 7. DIF 0.7 V AC Timing Characteristics (Non-Spread Spectrum Mode)1 (Continued) Parameter Symbol CLK 100 MHz, 133 MHz Min Typ Max Unit Voltage Low (Typ 0.7 V)3,8,13 VLOW –150 15 150 mV Maximum Voltage8 VMAX — 850 1150 mV Minimum Voltage VMIN –300 — — mV Absolute Crossing Point Voltages3,8,14,15,16 VoxABS 300 450 550 mV Total Variation of Vcross Over All Edges3,8,18 Total ∆ Vox — 14 140 mV Duty Cycle3,4 DC 45 — 55 % Maximum Voltage (Overshoot)3,8,19 Vovs — — VHigh + 0.3 V Maximum Voltage (Undershoot)3,8,20 Vuds — — VLow – 0.3 V Ringback Voltage3,8 Vrb 0.2 — N/A V Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. This is the time from the valid CLK_IN input clocks and the assertion of the PWRGD signal level at 1.8–2.0 V to the time that stable clocks are output from the buffer chip (PLL locked). 3. Test configuration is Rs = 33.2 , 2 pF for 100  transmission line; Rs = 27 , 2 pF for 85  transmission line. 4. Measurement taken from differential waveform. 5. Using frequency counter with the measurement interval equal or greater than 0.15 s, target frequencies are 99,750,00 Hz, 133,000,000 Hz. 6. The average period over any 1 µs period of time must be greater than the minimum and less than the maximum specified period. 7. Measure taken from differential waveform on a component test board. The edge (slew) rate is measured from –150 mV to +150 mV on the differential waveform. Scope is set to average because the scope sample clock is making most of the dynamic wiggles along the clock edge. Only valid for Rising clock and Falling CLOCK. Signal must be monotonic through the Vol to Voh region for Trise and Tfall. 8. Measurement taken from single-ended waveform. 9. Measured with oscilloscope, averaging off, using min max statistics. Variation is the delta between min and max. 10. Measured with oscilloscope, averaging on. The difference between the rising edge rate (average) of clock verses the falling edge rate (average) of CLOCK. 11. Rise/Fall matching is derived using the following, 2*(Trise – Tfall) / (Trise + Tfall). 12. VHigh is defined as the statistical average High value as obtained by using the Oscilloscope VHigh Math function. 13. VLow is defined as the statistical average Low value as obtained by using the Oscilloscope VLow Math function. 14. Measured at crossing point where the instantaneous voltage value of the rising edge of CLK equals the falling edge of CLK. 15. This measurement refers to the total variation from the lowest crossing point to the highest, regardless of which edge is crossing. 16. The crossing point must meet the absolute and relative crossing point specifications simultaneously. 17. Vcross(rel) Min and Max are derived using the following, Vcross(rel) Min = 0.250 + 0.5 (Vhavg – 0.700), Vcross(rel) Max = 0.550 – 0.5 (0.700 – Vhavg), (see Figures 3–4 for further clarification). 18. Vcross is defined as the total variation of all crossing voltages of Rising CLOCK and Falling CLOCK. This is the maximum allowed variance in Vcross for any particular system. 19. Overshoot is defined as the absolute value of the maximum voltage. 20. Undershoot is defined as the absolute value of the minimum voltage. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 11 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 Table 8. Clock Periods Differential Clock Outputs with SSC Disabled SSC OFF Center Freq, MHz Measurement Window 1 Clock –C-C Jitter AbsPer Min 1 µs 0.1 s –ppm –SSC Long Short Term AVG Term AVG Min Min 0.1 s Unit 0.1 s 1 µs 0 ppm Period Nominal +SSC +ppm Short Long Term AVG Term AVG Max Max 1 Clock +C-C Jitter AbsPer Max 100.00 9.94900 9.99900 10.00000 10.00100 10.05100 ns 133.33 7.44925 7.49925 7.50000 7.50075 7.55075 ns Table 9. Clock Periods Differential Clock Outputs with SSC Enabled SSC ON Center Freq, MHz Measurement Window 1 Clock –C-C Jitter AbsPer Min 1 µs 0.1 s –ppm –SSC Long Short Term AVG Term AVG Min Min 0.1 s 0.1 s Unit 1 µs 0 ppm Period Nominal +SSC +ppm Short Long Term AVG Term AVG Max Max 1 Clock +C-C Jitter AbsPer Max 99.75 9.94906 9.99906 10.02406 10.02506 10.02607 10.05107 10.10107 ns 133.33 7.44930 7.49930 7.51805 7.51880 7.51955 7.53830 7.58830 ns Table 10. Absolute Maximum Ratings Parameter Symbol Min Max Unit VDD/VDD_A — 4.6 V VDD_IO — 4.6 V VIH — 4.6 V VIL −0.5 — V Storage Temperature1 ts –65 150 °C Input ESD protection3 ESD 2000 — V 3.3 V Core Supply Voltage1 3.3 V I/O Supply Voltage1 3.3 V Input High Voltage1,2 3.3 V Input Low Voltage1 Notes: 1. Consult manufacturer regarding extended operation in excess of normal dc operating parameters. 2. Maximum VIH is not to exceed maximum VDD. 3. Human body model. 12 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 2. Functional Description 2.1. CLK_IN, CLK_IN The differential input clock is expected to be sourced from a clock synthesizer or PCH. 2.2. 100M_133M—Frequency Selection The Si53119 is optimized for lowest phase jitter performance at operating frequencies of 100 and 133 MHz. 100M_133M is a hardware input pin, which programs the appropriate output frequency of the differential outputs. Note that the CLK_IN frequency must be equal to the CLK_OUT frequency; meaning Si53119 is operated in 1:1 mode only. Frequency selection can be enabled by the 100M_133M hardware pin. An external pull-up or pull-down resistor is attached to this pin to select the input/output frequency. The functionality is summarized in Table 11. Table 11. Frequency Program Table 100M_133M Optimized Frequency (DIF_IN = DIF_x) 0 133.33 MHz 1 100.00 MHz Note: All differential outputs transition from 100 to 133 MHz or from 133 to 100 MHz in a glitch free manner. 2.3. SA_0, SA_1—Address Selection SA_0 and SA_1 are tri-level hardware pins, which program the appropriate address for the Si53119. The two trilevel input pins that can configure the device to nine different addresses. Table 12. SMBUS Address Table SA_1 SA_0 SMBUS Address L L D8 L M DA L H DE M L C2 M M C4 M H C6 H L CA H M CC H H CE Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 13 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 2.4. CKPWRGD/PWRDN CKPWRGD is asserted high and deasserted low. Deassertion of PWRGD (pulling the signal low) is equivalent to indicating a power down condition. CKPWRGD (assertion) is used by the Si53119 to sample initial configurations, such as frequency select condition and SA selections. After CKPWRGD has been asserted high for the first time, the pin becomes a PWRDN (Power Down) pin that can be used to shut off all clocks cleanly and instruct the device to invoke power-saving mode. PWRDN is a completely asynchronous active low input. When entering powersaving mode, PWRDN should be asserted low prior to shutting off the input clock or power to ensure all clocks shut down in a glitch free manner. When PWRDN is asserted low, all clocks will be disabled prior to turning off the VCO. When PWRDN is deasserted high, all clocks will start and stop without any abnormal behavior and will meet all ac and dc parameters. Note: The assertion and deassertion of PWRDN is absolutely asynchronous. Warning: Disabling of the CLK_IN input clock prior to assertion of PWRDN is an undefined mode and not recommended. Operation in this mode may result in glitches, excessive frequency shifting, etc. Table 13. CKPWRGD/PWRDN Functionality CKPWRGD/P WRDN DIF_IN/ DINF_IN# SMBus EN bit DIF-x/ DIF_x# FBOUT_NC/ FBOUT_NC# PLL State 0 X X Low/Low Low/Low OFF 1 Running 0 Low/Low Running ON 1 Running Running ON 2.4.1. PWRDN Assertion When PWRDN is sampled low by two consecutive rising edges of DIF, all differential outputs must be held LOW/LOW on the next DIF high-to-low transition. PWRDWN DIF DIF Figure 1. PWRDN Assertion 14 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 2.4.2. CKPWRGD Assertion The powerup latency is to be less than 1.8 ms. This is the time from a valid CLK_IN input clock and the assertion of the PWRGD signal to the time that stable clocks are output from the device (PLL locked). All differential outputs stopped in a LOW/LOW condition resulting from power down must be driven high in less than 300 µs of PWRDN deassertion to a voltage greater than 200 mV. Tstable 0 and 400 mA current rating. Figure 11. Schematic Example of the Si53119 Power Filtering 30 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 7. Ordering Guide Part Number Package Type Temperature Si53119-A01AGM 72-pin QFN Extended, –40 to 85 C Si53119-A01AGMR 72-pin QFN—Tape and Reel Extended, –40 to 85 C Lead-free Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 31 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 8. Package Outline Figure 12 illustrates the package details for the Si53119. Table 27 lists the values for the dimensions shown in the illustration. Figure 12. 72-Pin Quad Flat No Lead (QFN) Package Table 27. Package Dimensions Dimension Min Nom Max Dimension Min Nom Max A 0.80 0.85 0.90 E2 5.90 6.00 6.10 A1 0.00 0.02 0.05 L 0.30 0.40 0.50 b 0.18 0.25 0.30 aaa 0.10 bbb 0.10 ccc 0.08 D D2 10.00 BSC. 5.90 6.00 6.10 e 0.50 BSC. ddd 0.10 E 10.00 BSC. eee 0.05 Notes: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. 3. This drawing conforms to JEDEC outline MO-220 4. Recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification for Small Body Components. 32 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 Si53119 9. Land Pattern: 72-pin QFN Figure 13 shows the recommended land pattern details for the Si53119 in a 72-pin QFN package. Table 28 lists the values for the dimensions shown in the illustration.   Figure 13. 72-pin QFN Land Pattern Table 28. PCB Land Pattern Dimensions Dimension mm C1 9.90 C2 9.90 E 0.50 X1 0.30 Y1 0.85 X2 6.10 Y2 6.10 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 33 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 S i 5 3 11 9 DOCUMENT CHANGE LIST Revision 0.9 to Revision 1.0  Corrected specs in Table 6, “Phase Jitter,” on page 8. Revision 1.0 to Revision 1.1 Updated Features on page 1. Updated Description on page 1.  Updated specs in Table 6, “Phase Jitter,” on page 8.   Revision 1.1 to Revision 1.2 February 22, 2016  Corrected specs in Table 1, “DC Operating Characteristics,” on page 4.  Updated operating characteristics in Table 3, Table 4, and Table 5. Revision 1.2 to Revision 1.3 November 22, 2017 Removed Gen4 PLL mode jitter spec.  Added Table 25, “Byte 18: PLL Mode Control Register,” on page 25.  34 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 3, 2021 ClockBuilder Pro Customize Skyworks clock generators, jitter attenuators and network synchronizers with a single tool. With CBPro you can control evaluation boards, access documentation, request a custom part number, export for in-system programming and more! www.skyworksinc.com/CBPro Portfolio SW/HW Quality Support & Resources www.skyworksinc.com/ia/timing www.skyworksinc.com/CBPro www.skyworksinc.com/quality www.skyworksinc.com/support Copyright © 2021 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks’ Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of Skyworks’ published specifications or parameters. Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540 |
SI53119-A01AGMR 价格&库存

很抱歉,暂时无法提供与“SI53119-A01AGMR”相匹配的价格&库存,您可以联系我们找货

免费人工找货