Description
EVB Features
The Si5345-D-EVB is used for evaluating the Si5345
Any-Frequency, Any-Output, Jitter-Attenuating Clock
Multiplier revision D. The device revision is
distinguished by a white 1 inch x 0.187 inch label with
the text “SI5345-D-EB” installed in the lower left hand
corner of the board. (For ordering purposes only, the
terms “EB” and “EVB” refer to the board and the kit
respectively. For the purpose of this document, the
terms are synonymous in context.)
Powered from USB port or external power supply.
Onboard 48 MHz XTAL or Reference SMA Inputs
allow holdover mode of operation on the Si5345.
ClockBuilder® Pro (CBPro) GUI programmable VDD
supply allows device to operate from 3.3, 2.5, or
1.8 V.
CBPro GUI programmable VDDO supplies allow each
of the 10 outputs to have its own power supply
voltage selectable from 3.3, 2.5, or 1.8 V.
CBPro GUI-controlled voltage, current, and power
measurements of VDD and all VDDO supplies.
Status LEDs for power supplies and control/status
signals of Si5345.
SMA connectors for input clocks, output clocks, and
optional external timing reference clock.
Figure 1. Si5345-D Evaluation Board
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
1. Functional Block Diagram
Below is a functional block diagram of the Si5345-D-EB. This evaluation board can be connected to a PC via the
main USB connector for programming, control, and monitoring. See section “3. Quick Start” or section “10.3.
Overview of ClockBuilder Pro Applications” for more information.
Figure 2. Si5345-D-EB Functional Block Diagram
2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
2. Si5345-D-EVB Support Documentation and ClockBuilder Pro Software
All Si5345-D-EVB schematics, BOMs, User’s Guides, and software can be found online at the following link:
www.skyworksinc.com/support-ia
3. Quick Start
1. Install ClockBuilder Pro desktop software from
www.skyworksinc.com/en/application-pages/clockbuilder-pro-software.
2. Connect a USB cable from Si5345-D-EB to the PC where the software was installed.
3. Confirm jumpers are installed as shown in Table 1.
4. Launch the ClockBuilder Pro Software.
5. You can use ClockBuilder Pro to create, download, and run a frequency plan on the Si5345-D-EB.
6. For the Si5345 data sheet, go to www.skyworksinc.com/en/Products/Timing.
4. Jumper Defaults
Table 1. Si5345-D-EB Jumper Defaults*
Location
Type
I = Installed
0 = Open
Location
Type
I = Installed
0 = Open
JP1
2 pin
O
JP23
2 pin
O
JP2
2 pin
I
JP24
2 pin
O
JP3
2 pin
O
JP25
2 pin
O
JP4
2 pin
I
JP26
2 pin
O
JP5
2 pin
I
JP27
2 pin
O
JP6
2 pin
I
JP28
2 pin
O
JP7
2 pin
I
JP29
2 pin
O
JP8
2 pin
O
JP30
2 pin
O
JP9
2 pin
O
JP31
2 pin
O
JP10
2 pin
I
JP32
2 pin
O
JP13
2 pin
O
JP33
2 pin
O
JP14
2 pin
I
JP34
2 pin
O
JP15
3 pin
1 to 2
JP35
2 pin
O
JP16
3 pin
1 to 2
JP36
2 pin
O
JP17
2 pin
O
JP38
3 pin
All Open
JP18
2 pin
O
JP39
2 pin
O
JP19
2 pin
O
JP40
2 pin
O
JP20
2 pin
O
JP41
2 pin
O
JP21
2 pin
O
J36
5 x 2 Hdr
All 5 installed
JP22
2 pin
O
*Note: Refer to the Si5345-D-EB schematics for the functionality associated with each jumper.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
3
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
5. Status LEDs
Table 2. Si5345-D-EB Status LEDs
Location
Silkscreen
Color
Status Function Indication
D27
5VUSBMAIN
Blue
Main USB +5 V present
D22
3P3V
Blue
DUT +3.3 V is present
D26
VDD DUT
Blue
DUT VDD voltage present
D25
INTR
Red
MCU INTR (Interrupt) active
D21
READY
Green
MCU Ready
D24
BUSY
Green
MCU Busy
D27, D22, and D26 are illuminated when USB +5 V, Si5345 +3.3 V, and Si5345 VDD supply voltages, respectively,
are present. D25, D21, and D24 are status LEDs showing on-board MCU activity.
Figure 3. Status LEDs
4
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
6. External Reference Input (XA/XB)
An external reference (XTAL) is used in combination with the internal oscillator to produce an ultra-low jitter
reference clock for the DSPLL and for providing a stable reference for the free-run and holdover modes. The
Si5345-D-EVB can also accommodate an external reference clock instead of a crystal. To evaluate the device with
a REFCLK, C111 and C113 must be populated and the XTAL removed (see Figure 4 below). The REFCLK can
then be supplied to J39 and J40.
Figure 4. External Reference Input Circuit
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
5
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
7. Clock Input Circuits (INx/INxB)
The Si5345-D-EB has eight SMA connectors (IN0, IN0B–IN3, IN3B) for receiving external clock signals. All input
clocks are terminated as shown in Figure 5 below. Note input clocks are ac-coupled and 50 terminated. This
represents four differential input clock pairs. Single-ended clocks can be used by appropriately driving one side of
the differential pair with a single-ended clock. For details on how to configure inputs as single-ended, please refer
to the Si5345 data sheet.
Figure 5. Input Clock Termination Circuit
8. Clock Output Circuits (OUTx/OUTxB)
Each of the twenty output drivers (10 differential pairs) is ac-coupled to its respective SMA connector. The output
clock termination circuit is shown in Figure 6 below. The output signal will have no dc bias. If dc coupling is
required, the ac coupling capacitors can be replaced with a resistor of appropriate value. The Si5345-D-EVB
provides pads for optional output termination resistors and/or low frequency capacitors. Note that components with
schematic “NI” designation are not normally populated on the Si5345-D-EB and provide locations on the PCB for
optional dc/ac terminations by the end user.
Figure 6. Output Clock Termination Circuit
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
9. Installing ClockBuilder Pro Desktop Software
To install the CBOPro software on any Windows 7 (or above) PC:
Go to www.skyworksinc.com/en/application-pages/clockbuilder-pro-software and download ClockBuilder Pro
software.
Installation instructions and User’s Guide for ClockBuilder Pro can be found at the download link shown above.
Please follow the instructions as indicated.
10. Using the Si5345-D-EVB
10.1. Connecting the EVB to Your Host PC
Once ClockBuilder Pro software is installed, connect to the EVB with a USB cable as shown below.
Figure 7. EVB Connection Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
7
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
10.2. Additional Power Supplies
Although additional power (besides the power supplied by the host PC’s USB port) is not needed for most
configurations, two additional +5 VDC power supplies (MAIN and AUX) can be connected to J33 and J34 (located
on the bottom of the board, near the USB connector). Refer to the Si5345-D-EB schematic for details.
The Si5345-D-EB comes pre-configured with jumpers installed at JP15 and JP16 (pins 1-2 in both cases) in order
to select “USB”. These jumpers, together with the components installed, configure the evaluation board to obtain all
+5 V power solely through the main USB connector at J37. This setup is the default configuration and should
normally be sufficient.
Figure 8 shows the correct installation of the jumper shunts at JP15 and JP16 for default or standard operation.
Figure 8. JP15-JP16 Standard Jumper Shunt Installation
Errata Note:Some early versions of the 64-pin Si534x-EVBs may have the silkscreen text at JP15-JP16 reversed regarding
EXT and USB, i.e., USB EXT instead of EXT USB. Regardless, the correct installation of the jumper shunts for
default or standard operation is on the right hand side as read and viewed in Figure 8.
The general guidelines for single USB power supply operation are listed below:
Use
either a USB 3.0 or USB 2.0 port. These ports are specified to supply 900 mA and 500 mA respectively
at +5 V.
If
you are working with a USB 2.0 port and you are current limited, turn off enough DUT output voltage
regulators to drop the total DUT current ≤ 470 mA. (Note: USB 2.0 ports may supply > 500 mA. Provided the
nominal +5 V drops gracefully by less than 10%, the EVB will still work.)
If
you are working with a USB 2.0 and you are current limited and need all output clock drivers enabled, reconfigure the EVB to drive the DUT output voltage regulators from an external +5 V power supply as follows:
Connect
Move
8
external +5 V power supply to terminal block J33 on the back side of the PCB.
the jumper at JP15 from pins 1-2 USB to pins 2-3 EXT.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
10.3. Overview of ClockBuilder ProApplications
Note: The following instructions and screen captures may vary slightly depending on your version of ClockBuilder
Pro. The ClockBuilder Pro installer will install two main applications:
Figure 9. Application #1: ClockBuilder Pro Wizard
Use the CBPro Wizard to:
Create
a new design
Review
or edit an existing design
Export:
create in-system programming
Figure 10. Application #2: EVB GUI
Use the EVB GUI to:
Download
configuration to EVB’s DUT (Si5345)
Control
the EVB’s regulators
Monitor
voltage, current, power on the EVB
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
9
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
10.4. Common ClockBuilder Pro Work Flow Scenarios
There are three common workflow scenarios when using CBPro and the Si5345-D-EVB. These workflow scenarios
are:
Workflow
Scenario #1: Testing a Skyworks-Created Default Configuration
Workflow
Scenario #2: Modifying the Default Skyworks-Created Device Configuration
Workflow
Scenario #3: Testing a User-Created Device Configuration
Each is described in more detail in the following sections.
10.5. Workflow Scenario #1: Testing a Skyworks-Created Default Configuration
The flow for using the EVB GUI to initialize and control a device on the EVB is as follows.
Once the PC and EVB are connected, launch ClockBuilder Pro by clicking on this icon on your PC’s desktop.
Figure 11. ClockBuilder Pro Desktop Icon
If an EVB is detected, click on the “Open Default Plan” button on the Wizard’s main menu. CBPro automatically
detects the EVB and device type.
Figure 12. Open Default Plan
Once you open the default plan (based on your EVB model number), a popup will appear.
Figure 13. Write Design to EVB Dialog
10
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
Select “Yes” to write the default plan to the Si5345 device mounted on your EVB. This ensures the device is
completely reconfigured per the Skyworks default plan for the DUT type mounted on the EVB.
Figure 14. Writing Design Status
After CBPro writes the default plan to the EVB, click on “Open EVB GUI” as shown below.
Figure 15. Open EVB GUI
The EVB GUI will appear. Note all power supplies will be set to the values defined in the device’s default CBPro
project file created by Skyworks, as shown below.
Figure 16. EVB GUI Window
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
11
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
10.5.1. Verify Free-Run Mode Operation
Assuming no external clocks have been connected to the INPUT CLOCK differential SMA connectors (labeled
“INx/INxB”) located around the perimeter of the EVB, the DUT should now be operating in free-run mode, as the
DUT will be locked to the crystal in this case.
You can run a quick check to determine if the device is powered up and generating output clocks (and consuming
power) by clicking on the Read All button highlighted above and then reviewing the voltage, current and power
readings for each VDDx supply.
Note: Shutting “Off” then “On” of the VDD and VDDA supplies will power-down and reset the DUT. Every time you do
this, to reload the Skyworks-created default plan into the DUT’s register space, you must go back to the Wizard’s main menu and select “Write Design to EVB”:
Figure 17. Write Design to EVB
Failure to do the step above will cause the device to read in a pre-programmed plan from its non-volatile
memory (NVM). However, the plan loaded from the NVM may not be the latest plan recommended by
Skyworks for evaluation.
At this point, you should verify the presence and frequencies of the output clocks (running to free-run mode from
the crystal) using appropriate external instrumentation connected to the output clock SMA connectors. To verify the
output clocks are toggling at the correct frequency and signal format, click on View Design Report as highlighted
below.
Figure 18. View Design Report
12
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
Your configuration’s design report will appear in a new window, as shown below. Compare the observed output
clocks to the frequencies and formats noted in your default project’s Design Report.
Figure 19. Design Report Window
10.5.2. Verify Locked Mode Operation
Assuming you connect the correct input clocks to the EVB (as noted in the Design Report shown above), the DUT
on your EVB will be running in “locked” mode.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
13
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
10.6. Workflow Scenario #2: Modifying the Default Skyworks-Created Device
Configuration
To modify the “default” configuration using the CBPro Wizard, click on Edit Configuration with Wizard:
Figure 20. Edit Configuration with Wizard
You will now be taken to the Wizard’s step-by-step menus to allow you to change any of the default plan’s
operating configurations.
Figure 21. Design Wizard
14
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
Note you can click on the icon on the lower left hand corner of the menu to confirm if your frequency plan is valid.
After making your desired changes, you can click on Write to EVB to update the DUT to reconfigure your device
real-time. The Design Write status window will appear each time you make a change.
Figure 22. Writing Design Status
10.7. Workflow Scenario #3: Testing a User-Created Device Configuration
To test a previously created user configuration, open the CBPro Wizard by clicking on the icon on your desktop and
then selecting Open Design Project File.
Figure 23. Open Design Project File
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
15
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
Locate your CBPro design file in the Windows file browser.
Figure 24. Browse to Project File
Select Yes when the WRITE DESIGN to EVB popup appears:
Figure 25. Write Design to EVB Dialog
The progress bar will be launched. Once the new design project file has been written to the device, verify the
presence and frequencies of your output clocks and other operating configurations using external instrumentation.
16
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si5345-D-EVB
10.8. Exporting the Register Map File for Device Programming by a Host Processor
You can also export your configuration to a file format suitable for in-system programming by selecting Export as
shown below:
Figure 26. Export Register Map File
You can now write your device’s complete configuration to file formats suitable for in-system programming.
Figure 27. Export Settings
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
17
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
Si 5345- D- EV B
11. Writing a New Frequency Plan or Device Configuration to Non-Volatile
Memory (OTP)
Note: Writing to the device non-volatile memory (OTP) is NOT the same as writing a configuration into the Si5345 using
ClockBuilder Pro on the Si5345-D-EB. Writing a configuration into the EVB from ClockBuilder Pro is done using Si5345
RAM space and can be done virtually unlimited numbers of times. Writing to OTP is limited as described below.
Refer to the Si534x/8x Family Reference Manuals and device data sheets for information on how to write a
configuration to the EVB DUT’s non-volatile memory (OTP). The OTP can be programmed a maximum of two
times only. Care must be taken to ensure the configuration desired is valid when choosing to write to OTP.
12. Si5345-D-EVB Schematic, Layout, and Bill of Materials (BOM)
The Si5345-D-EVB Schematic, Layout, and Bill of Materials (BOM) can be found online at:
www.skyworksinc.com/support-ia
Note: Please be aware that the Si5345-D-EB schematic is in OrCad Capture hierarchical format and not in a typical “flat”
schematic format.
18
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 1.0 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 2, 2021
ClockBuilder Pro
Customize Skyworks clock generators,
jitter attenuators and network
synchronizers with a single tool. With
CBPro you can control evaluation
boards, access documentation, request
a custom part number, export for
in-system programming and more!
www.skyworksinc.com/CBPro
Portfolio
SW/HW
Quality
Support & Resources
www.skyworksinc.com/ia/timing
www.skyworksinc.com/CBPro
www.skyworksinc.com/quality
www.skyworksinc.com/support
Copyright © 2021 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the
information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer.
Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation,
products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or
information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability
for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or
materials, except as may be provided in Skyworks’ Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR
OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR
COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR
ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT
OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks
products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such
applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of
design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating
safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any
equipment resulting from the use of Skyworks products outside of Skyworks’ published specifications or parameters.
Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or
registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for
identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at
www.skyworksinc.com, are incorporated by reference.
Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com
USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540 |