0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
RD-HNPLC-2DW920KIT01

RD-HNPLC-2DW920KIT01

  • 厂商:

    SIPEX(迈凌)

  • 封装:

  • 描述:

    DW920 POWERLINE EVAL KIT

  • 数据手册
  • 价格&库存
RD-HNPLC-2DW920KIT01 数据手册
Wave-2 Powerline Networking Evaluation Public User Guide • www.maxlinear.com • 057-W2PLHNPUGR01 Wave-2 Powerline Networking Evaluation Public User Guide Revision History Revision History Document No. Release Date Change Description 057-W2PLHNPUGR01 October 18, 2018 Updated: ■ ■ 057-W2PLHNPUGR00 March 13, 2018 New template applied. Minor edits so that the document applies to home networking or industrial applications. Initial release. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 ii Wave-2 Powerline Networking Evaluation Public User Guide Table of Contents Table of Contents Introduction......................................................................................................................................................... 1 Wave-2 G.hn Networking Technology............................................................................................................... 2 Ordering Information.......................................................................................................................................... 3 Powerline Adapter User Interface ..................................................................................................................... 5 Powerline Network Setup................................................................................................................................... 7 Pairing ...........................................................................................................................................................................7 Configuring a Secure Powerline Network......................................................................................................................7 Return to Default Pairing Settings Procedure................................................................................................................8 Factory Reset Procedure...............................................................................................................................................8 Laboratory Evaluation and Tests ...................................................................................................................... 9 Evaluation Software Tool...............................................................................................................................................9 Network Performance Test............................................................................................................................................9 Test 1: Dynamic Range Measurement in Flat Channel........................................................................................9 Test 2: RFC 2544 Throughput/Latency Test ......................................................................................................12 Powerstrip Test............................................................................................................................................................14 Power Mask and Notches Test....................................................................................................................................16 Neighboring Networks Test .........................................................................................................................................17 Point-to-Multipoint Traffic Test in Flat Channels..........................................................................................................19 Field Evaluation and Tests............................................................................................................................... 21 Planning a Field Test Campaign .................................................................................................................................21 Determining the Size of the Testing Campaign..................................................................................................22 Determine the Types of Homes..........................................................................................................................22 Selecting the Tests to Be Performed..................................................................................................................22 Select PLC Profiles to Be Tested .......................................................................................................................23 Selecting the Points to Be Tested ......................................................................................................................23 Collecting the Results.........................................................................................................................................23 Appendix A: Safety Recommendations.......................................................................................................... 25 Avoiding Injuries ..........................................................................................................................................................25 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 iii Wave-2 Powerline Networking Evaluation Public User Guide List of Tables List of Tables Table 1: Wave-2 PLC Networking Ordering Information ...................................................................................... 3 Table 2: Ordering Information for Telebyte’s UPLC Splitters................................................................................ 4 Table 3: DW920 Connectors and Button .............................................................................................................. 5 Table 4: Link Quality Indicator Description ........................................................................................................... 6 Table 5: Secure Indicator Description................................................................................................................... 6 Table 6: CONFIG Button ...................................................................................................................................... 6 Table 7: DW920 Iperf UDP Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile ........................... 11 Table 8: DW920 Iperf TCP Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile............................ 11 Table 9: DW920 UDP Unidirectional Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile............. 13 Table 10: DW920 UDP Bidirectional Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile............. 13 Table 11: PLC 100 MHz MIMO Boost 2 ˟ 2–DW920 Ixia RF2544 PLR 0% MAC xput Test Results for Same Powerstrip .......................................................................................................................................... 15 Table 12: Results RFC 2889 Fully Meshed Test PLR 0% Bidirectional ............................................................. 20 Table 13: Example of General Field Test Information ........................................................................................ 23 Table 14: Example of Outlet Description ............................................................................................................ 24 Table 15: Example of Outlets Description .......................................................................................................... 24 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 iv Wave-2 Powerline Networking Evaluation Public User Guide List of Figures List of Figures Figure 1: Wave-2 DW920 GbE to Powerline Adapter Block Diagram .................................................................. 2 Figure 2: Wave-2 DW920 Gigabit Ethernet to Powerline Adapter........................................................................ 3 Figure 3: Universal PLC Signal Splitter ................................................................................................................ 4 Figure 4: Pairing Procedure in MaxLinear Powerline Adapter.............................................................................. 7 Figure 5: Test Setup for 2 PLC Adapters Based on TR208................................................................................ 10 Figure 6: Test Setup with Powerstrip.................................................................................................................. 14 Figure 7: Notching Test ...................................................................................................................................... 16 Figure 8: Neighboring Networks Test Set Up Based on TR208 ......................................................................... 17 Figure 9: Test Diagrams for Point to Multipoint .................................................................................................. 19 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 v Wave-2 Powerline Networking Evaluation Public User Guide Introduction Introduction The scope of this document is to provide a guide for evaluating MaxLinear’s G.hn Wave-2 Powerline Communications (PLC) solution for home networking or industrial applications. The features described and performance data within this document are for guidance only, and they cannot be construed as any form of specification, guarantee, or contract between MaxLinear and the evaluator. This user guide helps engineers to evaluate powerline networking solution feature set at technical level using hardware and software tools provided in evaluation package, and to learn about the technology at the same time as checking its real world performance. Warning! The electrical safety of this Evaluation Kit (EVK) has not been fully evaluated against the requirements of the EN 60950-1:2006 (IEC 60950-1:2005) standard and this EVK does not fulfill with all the relevant electrical safety requirements stated in such standard. Before continuing read carefully the “Appendix A: Safety Recommendations” on page 25. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 1 Wave-2 Powerline Networking Evaluation Public User Guide Wave-2 G.hn Networking Technology Wave-2 G.hn Networking Technology MaxLinear’s standard International Telecommunication Union (ITU) G.hn technology enables a complete wireline transceiver for use over all existing cables: powerlines, coaxial cables, and phone lines. The MaxLinear G.hn offering introduces the new Wave-2 Digital Baseband (DBB) processor family 88LX5152/88LX5153/ 88LX5153A and new Analog Front End (AFE) 88LX2720/88LX2730/88LX2740/88LX2741 chipsets, Spirit 7.x firmware, SDK/API, associated reference designs, and auxiliary software tools. MaxLinear’s G.hn technology provides exceptional performance and industry-leading features, and it is intended for tripleplay service provider, industrial, and consumer applications. The new MaxLinear Wave-2 G.hn chipset provides a very compact, flexible, and cost-effective solution, which includes several interfaces such as an RGMII and SGMII. MaxLinear’s new 88LX5152/88LX5153/88LX5153A and 88LX2720/88LX2730/88LX2740/88LX2741 G.hn families support: ■ ■ ■ PHY bit rate of up to 2Gbps over phone line and coax line. SISO 200 MHz profile for coaxial and 2-wire telephone lines. Features such as: Phone and powerline Multiple Input Multiple Output (MIMO) 100 MHz profiles. On-chip remote management support (TR-069). Powerline Neighboring Networks Interference Mitigation (NDIM). Optimized power consumption with power saving mode. Flash 32Mbit Tx1 Dual Coupling Unit AC Line L N PE Rx1 ADC 1 88LX2720 AFE ADC 2 Tx2 DAC 2 HPF 2MHz Rx2 Rx3 ISN & AC Filter 5V 88LX5152 DBB SGMII ADC 3 ADC 4 88LX2720 AFE Control LEDs & Buttons Gigabit PHY 88E1514 RJ-45 + Magnetics ETH Ethernet GPIOs DAC 1 HPF 2MHz SPI1 3.3V 1.5V VDD_COR E Single DC/DC 88PG852 Single DC/DC 88PG852 Single DC/DC 88PG852 AC/DC 5V Figure 1: Wave-2 DW920 GbE to Powerline Adapter Block Diagram www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 2 Wave-2 Powerline Networking Evaluation Public User Guide Ordering Information Ordering Information To evaluate MaxLinear’s G.hn Wave-2 powerline networking technology, the following elements are required: ■ G.hn Wave-2 powerline evaluation kit (2 ˟DW920reference designs, using 88LX515 and 88LX2720 chipset) with Spirit 7.x HN firmware loaded. Be aware that some multi-mode test cases require more than 1 kit. ■ ■ This document: Wave-2 Powerline Networking Evaluation Public User Guide. Spirit Configuration Tool (SCT) to configure adapters during testing. Figure 2: Wave-2 DW920 Gigabit Ethernet to Powerline Adapter Table 1: Wave-2 PLC Networking Ordering Information Part Number Package Content RD-HNPLC-2DW920KIT01 Wave-2 Powerline Networking Evaluation Kit with TWO(2) G.hn adapters (88LX5152 and 88LX2720 based) and accessories. In addition to the DW920 EVK, MaxLinear recommends obtaining at least two Universal PLC Splitters. They are used to perform the proposed laboratory tests and control the attenuation between powerline boards. For home networking and broadband applications, use a 3-port mains-PLC signal splitter for SISO and vendor-independent MIMO as described in Broadband Forum’s Technical (BBF’s) Report TR-208. For further information, go to https://www.broadband-forum.org/ standards-and-software/technical-specifications/technical-reports. See Figure 5 on page 10. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 3 Wave-2 Powerline Networking Evaluation Public User Guide Ordering Information These Universal PLC splitters can be purchased through Telebyte, Inc. (http://www.telebytebroadband.com). The following table lists the corresponding ordering info for both European and North American varieties. Table 2: Ordering Information for Telebyte’s UPLC Splitters Package Content Part Number Number of Devices GHN-SP-UPLC-EU Universal PLC Splitter (European version) 1 GHN-SP-UPLC-NA Universal PLC Splitter (North American version) 1 BNC Male-BNC Male cables and several 20 dB and 10 dB 50Ohm BNC attenuators can be also required for performing the test cases described in this document. They are not included in UPLC kit, however they can be purchased in most hardware and electronics stores. Figure 3: Universal PLC Signal Splitter www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 4 Wave-2 Powerline Networking Evaluation Public User Guide Powerline Adapter User Interface Powerline Adapter User Interface The DW920 reference design incorporates one CONFIG button and two LEDs that allow the user to configure a secure G.hn network without using a computer and which also indicate the channel capacity in the receiver adapter. The DW920 incorporates also an extra LED to indicate the Ethernet link and activity. The main features provided by the DW920 hardware user interface are listed below: ■ Pairing (One Button Security setup, OBUS): Automatic generation of a random Domain Name and Encryption Password, used to guarantee network security, and exchanging of these parameters between adapters using a single button push as defined by HomeGrid Forum for compliance and interoperability purposes. ■ ■ ■ Link Quality indicator: With a three-color LED, three different levels of link quality are shown in the receiver adapter. Manual factory reset. Unpairing: Return to default security settings. . The following table lists the function and behavior of the LEDs and the buttons. Table 3: DW920 Connectors and Button Definition “CONFIG” Icon button1 Function Used to implement the following tasks: ■ One Button Security Setup (Pairing). ■ Return to default security settings (Unpairing). ■ Factory Reset. Link Quality1 Three-color LED indicating the application throughput level available in the G.hn link (throughput indicator) and the power saving mode. Ethernet1 LED indicates the link and traffic through Ethernet port. Secure1 LED indicating whether the device has received/generated the network key (it belongs to a single secure domain) or not. 1. See Figure 4 on page 7. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 5 Wave-2 Powerline Networking Evaluation Public User Guide Powerline Adapter User Interface Table 4: Link Quality Indicator Description Color Adapter Status Meaning Off ON No G.hn link. Red ON G.hn link is present and estimated application throughput < 20 Mbps (configurable value). Orange ON G.hn link is present and 20 Mbps (configurable) < estimated application throughput < 40 Mbps (configurable). Green ON G.hn link is present and estimated application throughput > 40 Mbps (configurable). Blinking (red, orange, or green) ON Tx/Rx activity in the G.hn port. Blinking in red every 5s POWER SAVING When the adapter enters in power saving, this LED blinks once every 5s. Table 5: Secure Indicator Description “Secure” LED State Meaning Off Device is not secure, it has neither received nor generated network keys (domain name and encryption password). On Device is secure (it has either received or generated network keys). Slow blinking Device is in configuration mode (able to exchange network keys). Quick blinking Device is in return to default security settings mode (unpairing). Three flashes Device has received key from other secure device, and it has finished its configuration. Table 6: CONFIG Button Button Meaning CONFIG ■ ■ ■ Press more than 2s (Secure indicator starts slow blinking) and release: The pairing procedure is started and configuration period is open. Press more than 5s (Secure indicator starts quick blinking) and release: Security settings are set to default values. Press more than 10s (Secure indicator switches off) and release: A factory reset is performed. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 6 Wave-2 Powerline Networking Evaluation Public User Guide Powerline Network Setup Powerline Network Setup Pairing All MaxLinear G.hn adapters have the same not unique domain name and AES encryption password by default. As a result, when they are plugged into the physical medium (PLC, coax, or phone line), a new network is created which operates smoothly, but without a secure unique configuration. Any nearby G.hn adapter (wanted or unwanted) with same common domain name and AES encryption password connected to the same electrical grid becomes part of this G.hn network. MaxLinear recommends to configure a private G.hn network (with a unique domain name and AES encryption password) to guarantee the security of every user’s network. Configuring a Secure Powerline Network Main steps of the pairing mechanism are listed below. ■ STEP 1 Press CONFIG button for 2s (until Secure LED starts slow blinking) to open a configuration period for 120s. If a device does not detect any other device within the configuration period, it generates a random network parameter key (domain name and encryption password) and Secure indicator remains ON. ■ STEP 2 Press CONFIG button for 2s (until Secure LED starts slow blinking) in an already secure device and in another unsecured device to open both configuration periods. ■ STEP 3 Secure device sends the keys to the new device (configuration process is successful when its Secure indicator flashes three times for 0.5s) and both belong to same secure and unique domain. At this point both devices can communicate data, Secure LED remains ON in both adapters and their Link Quality indicators show link quality between them. See the following figure to visualize the process. Figure 4: Pairing Procedure in MaxLinear Powerline Adapter Note: Any secure device (Secure indicator ON) can admit and exchange keys with an incoming unsecured device. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 7 Wave-2 Powerline Networking Evaluation Public User Guide Return to Default Pairing Settings Procedure Return to Default Pairing Settings Procedure The Return to Default Pairing Settings procedure forces a G.hn adapter to return to its default security settings. This procedure only resets the following parameters (domain name and AES encryption password) and does not affect other parameters such as (IP configuration, G.hn profile, notches, etc.). Perform the following steps to do it: 1. Press “CONFIG” button for more than 5s (Secure indicator should start slow blinking and after 5s starts quick blinking). Release the button. 2. At this time, the adapter resets its running security configuration to the default settings (unpaired). Factory Reset Procedure The Factory Reset procedure forces a G.hn adapter to return to its factory security settings. This procedure resets all parameters stored in flash memory, including (IP configuration, G.hn profile, security settings, notches, log file, QoS, Ethernet powers saving, etc). Perform the following steps to do it. 1. Press CONFIG button (Secure indicator should start slow blinking and after 5s quick blinking) and DO NOT release it until the Secure indicator switches OFF (it takes around 10s). Release the button. 2. After a few seconds the Link Quality indicator is also OFF. 3. At this time, the adapter resets its running configuration to factory default settings and auto-reboots www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 8 Wave-2 Powerline Networking Evaluation Public User Guide Laboratory Evaluation and Tests Laboratory Evaluation and Tests Evaluation Software Tool The SCT is a Java software tool to help evaluators during their testing of G.hn adapters. SCT enables reading and writing main configuration settings of MaxLinear G.hn adapters belonging to same logical network and it is used for most of the evaluation tests introduced in this section. For more information about installation and use of SCT refer to document Spirit Configuration Tool (SCT) Public User Guide (052SCTPUG). Network Performance Test Test 1: Dynamic Range Measurement in Flat Channel This test concentrates on network performance. The evaluator can measure the variation of the following variables as a function of attenuation. ■ ■ ■ Physical throughput TCP throughput UDP throughput Test Equipment ■ ■ ■ 2 ˟ MaxLinear DW920adapters A dedicated network performance analysis system such as Ixia or Spirent's Smartbits Alternatively, use two PCs with one of the following software options: Chariot SW from Ixia. Iperf software (a public domain application that can be downloaded for free), but the specific hardware and operating system could place a limitation on the results. I.e., Windows PC usually limits iperf UDP performance as client, so Linux (or Mac OS)is recommended for UDP performance tests when possible. PCATTCP software (a public domain application that can be downloaded for free) which can be used on Linux and Windows PCs for both TCP and UDP measurements. It is available at http://www.pcausa.com/Utilities/pcattcp.htm. ■ ■ ■ ■ SCT 2 ˟ GHN-SP-UPLC 3 ˟ BNC coax cables Combined fixed attenuators Figure 5 on page 10 shows the test setup diagram using mentioned test equipment. Note: DW920 devices included in EVK are configured by default in PLC 100 MHz MIMO Boost 2˟2 profile. This mode has an improved PSD over 30 MHz. This PSD levels are equivalent to the ones used currently in commercial equipment across all different legacy powerline technologies. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 9 Wave-2 Powerline Networking Evaluation Public User Guide Network Performance Test Figure 5: Test Setup for 2 PLC Adapters Based on TR208 Test Methodology To perform this test, follow the steps below. 1. Select the G.hn PLC profile to be tested (PLC 100 MHz MIMO Boost 2 ˟ 2 profile) and configure it by using SCT. 2. Set an attenuation of 10 dB between the adapters. 3. Run the corresponding Ixia tests that measure TCP throughput, UDP throughput, latency, frame lost, and jitter. 4. Alternatively, run Iperf as follows below. a. Perform a TCP throughput test typing the following in a console window: Server side (PC1): iperf –s –w 32K Client side (PC2):iperf –c [Server IP] –w 32K –i 1 –t 60 –P 32 b. Perform a UDP throughput by typing: Server side (PC1): iperf -s –i 1 –u –w 512K Client side (PC2): iperf -c [Server IP] -i 1 –u –w 512K -t 60 -b X where X is the injected bandwidth (in bps) for the application. Select an X value around 950M. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 10 Wave-2 Powerline Networking Evaluation Public User Guide Network Performance Test 5. Alternatively, run PCATTCP as follows: a. Perform a TCP throughput test typing the following commands in a console window: Server side (PC1): PCATTCP.exe -r –c -f m -b 512000 Client side (PC2): PCATTCP.exe -t -f m –u -n 300000 b. Perform a UDP throughput test by typing: Server side (PC1): PCATTCP.exe -r –c –f m –u Client side (PC2): PCATTCP.exe -t -f m –u -n 300000 6. Optional: Write down the transmission and reception physical throughput obtained using SCT. 7. Repeat steps 3 to 6 increasing the attenuation value by 10 dB or 20 dB until achieved throughput is near to 0. 8. Write down the results in a table similar to the following table. Note: The following results were obtained using Spirit 7.6 HN GA version (SPIRIT.v7_6_r548+8) loaded. . Table 7: DW920 Iperf UDP Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile Attenuation PLC 100 MHz MIMO Boost 2˟2 10 dB 933 20 dB 933 30 dB 933 40 dB 903 50 dB 821 60 dB 587 70 dB 346 75 dB 230 80 dB 157 85 dB 81 90 dB 39 95 dB 16 100 dB 0 Table 8: DW920 Iperf TCP Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile Attenuation PLC 100 MHz MIMO Boost 2˟2 10 dB 765 20 dB 764 30 dB 756 40 dB 725 50 dB 631 60 dB 447 70 dB 260 80 dB 87.9 90 dB 25 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 11 Wave-2 Powerline Networking Evaluation Public User Guide Network Performance Test Test 2: RFC 2544 Throughput/Latency Test The RFC 2544 methodology, established by the Internet Engineering Task Force (IETF), is the de-facto methodology that outlines the tests required to measure and prove performance criteria for carrier Ethernet networks. The standard provides an out-of-service benchmarking methodology to evaluate the performance of network devices using throughput, frame loss, and latency tests. The methodology defines the frame size, test duration, and number of test iterations. Once completed, these tests provide performance metrics of the Ethernet network under test. To ensure that an Ethernet network is capable of supporting a variety of services (such as VoIP or video), the RFC 2544 test suite supports seven pre-defined frame sizes (64, 128, 256, 512, 1024, 1280, and 1518 bytes) to simulate various traffic conditions. Small frame sizes increase the number of frames transmitted, thereby stressing the network device as it must switch a large number of frames. The test starts by sending frames at the specified rate (usually the maximum theoretical rate of the port), while the frame loss is monitored. Frames are sent from and received at all the ports on the device under test, and the Tx and Rx rates are recorded. A binary, step, or combo search algorithm is used to identify the maximum rate at which no frame loss is experienced. The latency test determines the latency of the device under test. In the latency test, frames are transmitted for a fixed duration. Rx ports compute the latency values for every frame in the test by comparing the Tx timestamp with the Rx timestamp. The difference between the two timestamps is the latency. This quick test provides the statistical results: Average latency, minimum latency, and maximum latency. Test Equipment ■ ■ ■ ■ ■ 2 ˟ MaxLinear DW920 adaptersA dedicated network performance analysis system such as Ixia or Spirent's Smartbits SCT 2 ˟ GHN-SP-UPLC Combined fixedattenuators 3 ˟ BNC coax cables See below for test setup diagram. Test Methodology To perform this test: 1. Set a fixed attenuation of 50 dB between the G.hn modems. 2. Select the PLC 100 MHz MIMO Boost 2 ˟ 2 profile to be tested in the G.hn adapters using the SCT. 3. Run the RFC 2544 throughput/latency unidirectional test in Ixia IxNetwork (it takes several hours to be completed). 4. Write down the final results in a table similar to the example shown in the following tables. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 12 Wave-2 Powerline Networking Evaluation Public User Guide Network Performance Test Table 9: DW920 UDP Unidirectional Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile Test Results PLC 100 MHz MIMO Boost 2 ˟ 2 Frame Size (bytes) Passed Rate (Mbps) for PLR 0% 64 618.918 128 790.457 256 847.715 512 902.162 1024 911.742 1280 907.616 1512 917.457 Table 10: DW920 UDP Bidirectional Measurements (Mbps)–PLC MIMO 100 MHz Boost 2 ˟ 2 Profile Test Results PLC 100 MHz MIMO Boost 2 ˟ 2 Frame Size (bytes) Passed Rate (Mbps) for PLR 0% 64 657.051 128 799.817 256 857.821 512 889.911 1024 907.01 1280 885.986 1512 900.521 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 13 Wave-2 Powerline Networking Evaluation Public User Guide Powerstrip Test Powerstrip Test The aim of this test is to demonstrate the peak performance of the solution when attenuation between G.hn nodes cannot be managed. Test Equipment ■ ■ ■ ■ ■ 2 ˟ MaxLinear DW920 adapters A dedicated network performance analysis system such as Ixia or Spirent's Smartbits SCT Grounded power strip Universal PLC splitter (GHN-SP-UPLC) to filter out noise from powerlines Table 6 on page 14 shows a test setup diagram. Figure 6: Test Setup with Powerstrip Test Methodology To perform this test, follow the steps below: 1. Plug adapters in a grounded power strip a shown above. 2. Open the SCT. 3. Configure for instance “PLC 100 MHz MIMO Boost 2 ˟ 2” profile in all adapters using SCT. 4. Run the corresponding 5. RFC 2544 Ixia test. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 14 Wave-2 Powerline Networking Evaluation Public User Guide Powerstrip Test 6. Alternatively, run iperf as follows: c. Perform a TCP throughput test typing the following commands in a console window: Server side (PC1): iperf –s –w 32K Client side (PC2): iperf –c [Server IP] –w 32K –i 1 –t 60 –P 32 d. To test UDP throughput and jitter type the following: Server side (PC1): iperf -s –i 1 –u –w 512K Client side (PC2): iperf -c [Server IP] -i 1 –u –w 512K -t 60 -b X where X is the injected bandwidth (in bps) for the application. Select an X value of around 950M. 7. Alternatively, run PCATTCP as follows: a. Perform a TCP throughput test typing the following commands in a console window: Server side (PC1): PCATTCP.exe -r –c -f m -b 512000 Client side (PC2): PCATTCP.exe -t -f m –u -n 300000 b. To test UDP throughput type the following: Server side (PC1): PCATTCP.exe -r –c –f m –u Client side (PC2): PCATTCP.exe -t -f m –u -n 300000 Table 11: PLC 100 MHz MIMO Boost 2 ˟ 2–DW920 Ixia RF2544 PLR 0% MAC xput Test Results for Same Powerstrip Test Results PLC 100 MHz MIMO Boost 2 ˟ 2 Frame Size (bytes) Passed Rate (Mbps) for PLR 0% 64 589.189 128 790.448 256 869.427 512 887.098 1024 896.437 1280 907.321 1512 909.631 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 15 Wave-2 Powerline Networking Evaluation Public User Guide Power Mask and Notches Test Power Mask and Notches Test This test intends to check the frequency notching feature. With this test check the effects on the injected signal when the notches are added or removed and how to use Power Mask and Notches options in SCT. Test Equipment ■ ■ ■ ■ 1 ˟ MaxLinear DW920 adapter SCT Universal PLC splitter Auxiliary electrical cables The following figure shows a test setup diagram using mentioned test equipment. Figure 7: Notching Test Test Methodology To perform this test, follow the steps below. 1. Launch the SCT. 2. Discover the G.hn network. 3. Choose G.hn PLC 100 MHz MIMO Boost 2 ˟ 2profile to be tested and configure it by using SCT. 4. Go to Notches tab of the G.hn adapter. Refresh measurement. 5. See default notches defined by G.hn enabled in selected profile band. 6. In the SCT, select Notches Menu > Network > Configure Notches tab to add or remove some USER notches. You can select up to 10 user notches starting from 1-10). 7. Refresh the Notches tab and notice new notches appearing in graph. Leave only default notches profile removing extra notches before continuing with next tests. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 16 Wave-2 Powerline Networking Evaluation Public User Guide Neighboring Networks Test Neighboring Networks Test This test intends to demonstrate Network Domain Interference Mitigation (NDIM) feature. With this test the evaluator checks the benefits of automatic Domain ID (DOD) selection in each neighboring network to isolate neighboring domains for low visibility cases, and also coordination is case of high visibility among networks. Test Equipment ■ 4 ˟ MaxLinear DW920 adapters Note: A second MaxLinear’s Powerline Home Networking EVK should be purchased for being able to perform multinode testing with adapters. ■ ■ ■ ■ ■ ■ ■ A dedicated network performance analysis system such as Ixia, Spirent's Smartbits or four Linux PCs with iperf SCT 4 ˟ Universal PLC splitters Combined fixed and variable attenuators 9 ˟ BNC coax cables 2 ˟ 3-Channel symmetrical splitters Auxiliary electrical cables See below test setup diagram using mentioned test equipment. Figure 8: Neighboring Networks Test Set Up Based on TR208 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 17 Wave-2 Powerline Networking Evaluation Public User Guide Neighboring Networks Test Test Methodology To perform this test, follow the steps below. 1. Set all Attenuators to 20 dB (Att1=Att2=Att3=…=Att13=Att14=Att15=20 dB) such that nodes in the same network face an attenuation of 40 dB whereas nodes in different networks face an attenuation of 60 dB between them (average values measured by ETSI in house test campaign). 2. Plug two MaxLinear adapters to be intended as network 1 as shown in the above figure. 3. Configured these two adapters with a unique DN and Encryption PW (for instance, doing pairing procedure). 4. Send an UDP traffic using Smartbitsor iperf between adapters belonging to Network1 (DOD X) and take note of the throughput. 5. Unplug network 1 adapters and plug network 2 adapters. 6. Repeat same process in second network (DOD Y is self-configured). 7. Plug network 1 (DOD X) adapters again. 8. Now both networks are working with visibility between them but with different DOD (X and Y). 9. Send an UDP traffic using Smartbits(or other measurement tool) per network at same time and note throughputs of both networks. Get the aggregated throughput (adding the two throughput results) and compare with individual throughputs previously got. They should work almost as isolated, so aggregated throughput should be almost the same as adding network 1 xput + network 2 xput. 10. Set attenuation between neighboring networks to 0 dB removing attenuators between them (Att13, Att14, and Att15). 11. Now both networks are coordinated sharing access to common powerline channel in time. 12. Send an UDP traffic using Smartbits(or other measurement tool) per network at same time and note throughputs of both networks. Get the aggregated throughput (adding the two throughput results) and it should be similar to have only one network running. Note result and compare with rest of results. Bandwidth is shared, thus, aggregated throughput should be similar to individual xput of network 1 or network 2. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 18 Wave-2 Powerline Networking Evaluation Public User Guide Point-to-Multipoint Traffic Test in Flat Channels Point-to-Multipoint Traffic Test in Flat Channels This test concentrates on network performance in point to multipoint scenarios. As such, the variation of the following variables is measured as a function of attenuation for networks with three (or more) G.hn devices. ■ ■ ■ ■ ■ ■ Physical throughput TCP throughput UDP throughput Latency Jitter Frame Lost Test Equipment ■ ■ ■ ■ ■ ■ ■ ■ 4 ˟ MaxLinear DW920 adapters A dedicated network performance analysis system such as Ixia or Spirent's Smartbits. Alternatively, use four PCs with Chariot or Iperf software. SCT 4 ˟ universal PLC splitters Combined fixed and variable attenuators 9 ˟ BNC coax cables 2 ˟ 3-Channel symmetrical splitters Auxiliary electrical cables See below test setup diagram using mentioned test equipment. Figure 9: Test Diagrams for Point to Multipoint www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 19 Wave-2 Powerline Networking Evaluation Public User Guide Point-to-Multipoint Traffic Test in Flat Channels Test Methodology To perform this test: 1. Set all attenuators to 20 dB (Att1=Att2=Att3=…=Att10=Att11=Att12=20 dB) between the modems. 2. Write down the physical Tx and Rx throughput that you obtain using the SCT. 3. Run the corresponding Ixia IxNetworks tests (RFC 2889) that measure Bidirectional UDP throughput, latency, frame loss, and jitter for 1518 bytes packet length. 4. Alternatively, run Iperf as follows: G.hn D  G.hn A, G.hn C  G.hn A, and G.hn B  G.hn A, that is, PC 2 to PC 1, PC 3 to PC 1, and PC 4 to PC 1. a. Perform a TCP throughput test by typing the following in a console window: Server side (PC 1): iperf -s -w 32K –p iperf -s -w 32K –p iperf -s -w 32K –p Client side (PC 2, PC 3, PC 4): iperf -c [Server IP] -w 32K -i 1 -t 60 -P 32 –p b. To test UDP throughput and jitter type the following: Server side (PC 1): iperf -s -i 1 -u -w 512K –p iperf -s -i 1 -u -w 512K –p iperf -s -i 1 -u -w 512K –p Client side (PC 2, PC 3, PC 4): iperf -c [Server IP] -i 1 -u -w 512K -t 60 -b X –p where X is the injected bandwidth (in bps) for the application. The value for X should be selected such that the loss % is close to 0, for example, X = 900M. To generate bidirectional traffic with iperf use optional paramater –d in client commands. 5. Repeat steps 1 to 3 for different attenuations in node generating traffic flows (for instance, set Att1=Att2=Att3=40 dB). . Table 12: Results RFC 2889 Fully Meshed Test PLR 0% Bidirectional Frame Length UDP Throughput Aggregated (Mbps) 64 576.054 128 734.941 256 831.479 512 847.617 1024 860.799 1280 864.169 1518 869.321 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 20 Wave-2 Powerline Networking Evaluation Public User Guide Field Evaluation and Tests Field Evaluation and Tests Field evaluation is the process of testing a G.hn technology in a real world environment. The main differences between evaluating G.hn in the field and in the laboratory are listed below. ■ ■ ■ The field environment is more difficult to control than the lab environment. ■ The field test environment can have a wide variety of interfering devices, which might affect the performance of equipment. ■ The field environment has attenuation profiles depending on the frequency. The results of a particular field test may be more difficult to reproduce than those of a lab test. The signal environment in a field test is dynamic and the characteristics of the communication channel change along the time. The results achieved in a field environment could be affected by a wide range of variables; the key elements are listed below. ■ ■ The size of the home where the tests are being performed. ■ ■ ■ ■ Ground presence in the house. The way in which electricity is distributed: a single phase in all outlets or whether there are multiple phases going to different outlets in the home. The electrical layout of the home in terms of the locations of electrical distribution. The age of the home and the type of electrical cabling used. The range of interfering devices connected to the electrical network. Planning a Field Test Campaign Despite the fact that the field environment is far more variable than the laboratory environment, it is possible to improve the quality of the test campaign by following an appropriate procedure. The suggested steps to be performed when executing a field test campaign are listed below. 1. Determine the size of the testing campaign, resources and equipment required. 2. Determine the types of homes which is used in the campaign. 3. Select the tests to be performed. 4. Select G.hn profiles to be tested 5. Select the power points in each home to be tested (typical outlet where an IPTV service would be installed, for instance near the TV, in the home office, etc.). 6. Collect results. 7. Collate and present results. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 21 Wave-2 Powerline Networking Evaluation Public User Guide Planning a Field Test Campaign Determining the Size of the Testing Campaign Correct dimensioning of the test campaign beforehand is greatly help in ensuring the correct planning of the process. A field test in a single home usually takes a few hours performing typical throughput tests and depending on the number of chosen socket combinations. To get a more complete view of the capabilities of the technologies, the results of several homes can be compiled. Increasing the sample size can improve the statistical confidence in results. The basic equipment required to undertake the campaign is listed below. ■ ■ ■ Two G.hn adapters Laptop PCs, enough powerful to support throughputs close to 1Gbps in TCP and UDP. Testing software (iperf, Chariot or similar). In case of ISP operators it is also recommended to use real IPTV service in the evaluation interconnecting home gateway and STBs through adapters as they are used in real deployments. Determine the Types of Homes Home types vary greatly according to geographical area, demographic groups and a wide range of other factors. The home-wide performance of powerline products is therefore a function of all of these variables. When selecting homes for a field trial campaign it is important that the homes selected are representative for the target market to use the technology. For example, the homes selected for a product targeted at IPTV for the Asian market is radically different from those chosen for a high-end home networking product for the US market. To summarize, homes should be selected to provide a representative sample of the following variables for the chosen application, market, and geographical area. ■ ■ ■ ■ ■ ■ ■ Floor area Construction type (single tenant unit or apartment building) Number of floors Age Electrical layout (three phases or single phase) and ground presence Selected outlets description Rooms in the house Selecting the Tests to Be Performed Depending on the target application, and the resources available, any of the tests mentioned in the previous sections can be done in the field environment in a similar way. Typically, TCP and/or UDP throughput, latency, jitter and frame lost measurements are some examples commonly chosen, as well as testing real services with which the technology are used (for instance, IPTV service, HD streaming from video server to video player,…). Note: A very important point in case of performing benchmarking of different technologies is to do a test in one location for each technology almost at the same moment to avoid that the evolution of the communication channel along time affect the results. For example, execute test X for technology A in a socket combination and after it finishes execute same test X for technology B in same socket combination, same for C, and so on. After that, going to next socket combination and repeat the process. www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 22 Wave-2 Powerline Networking Evaluation Public User Guide Planning a Field Test Campaign Select PLC Profiles to Be Tested MaxLinear G.hn technology provides several configuration profiles that can be tested to choose the best initial configuration for a further commercial deployment. Currently main profile to be tested in MaxLinear Wave-2 G.hn solution is “PLC 100 MHz MIMO Boost 2˟2”. Selecting the Points to Be Tested The time required to perform tests and collate results can be reduced, using the fact that results can be treated statistically. So even with a subset of results it is possible to interpolate the results for any home. In the field, the electrical layout of the home in terms of wire length, type, and layout, is very seldom available. For this reason, field tests are generally aimed at assessing the statistical probability of achieving a particular performance between random outlet pairs, or between outlet pairs in random rooms. The number of measurements that can be made is therefore proportional to the square of the number of outlet pairs selected. For example, if there are seven outlets selected for testing PHY speed, there are 21 connections between outlets, each of which produces a different result depending on whether the transmission or reception path is tested giving a total of 42 combinations. The recommended number of outlets for testing is three to five per home, for instance the typical ones in which final users usually plug the G.hn adapters. For the correct collation of results in any statistical experiment, a proper random sample selection process is necessary, and for G.hn field tests there are two possibilities: ■ Randomly select a number of outlets in the home: This technique provides the inter-socket performance of the technology. ■ Randomly select a outlet in each room of the home: This technique provides the inter-room performance of the technology. Collecting the Results Test results can be collected for each socket pair, performing the relevant throughput tests. Below some tables are presented that could be used as a model for evaluator’s tests. Table 13: Example of General Field Test Information Test Parameters Date test performed Home tested Modem “A” MAC Address, firmware loaded and reference design Modem “B” MAC Address, firmware loaded and reference design Home floor area (m2) Electrical phase distribution Ground presence Building type Country and city Age (years) Number of floors Rooms in the house www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 23 Wave-2 Powerline Networking Evaluation Public User Guide Planning a Field Test Campaign . Table 14: Example of Outlet Description Socket No 1 2 3 4 5 Table 15: Example of Outlets Description Frame Lost Jitter Latency UDP Throughput TCP Throughput Physical Throughput Frame Lost Jitter Latency UDP Throughput TCP Throughput Receive Physical Throughput Outlet Pair Transmit 1-2 1-3 1-4 1-5 2-3 2-4 2-5 3-4 3-5 4-5 www.maxlinear.com October 18, 2018 057-W2PLHNPUGR01 24 Powerline Wave-2 Powerline Networking Evaluation Public User Guide Disclaimer Appendix A: Safety Recommendations To protect yourself from injuries and avoid damage of the device, always observe the following safety instructions when installing and working with the EVK. Warning! The electrical safety of this EVK has not been fully evaluated against the requirements of the EN 60950-1:2006 (IEC 60950-1:2005) standard and this EVK does not fulfill with all the relevant electrical safety requirements stated in such standard. Avoiding Injuries Warning! – – – Electrical current! Electrical current from power and communications cables can be hazardous. Never touch any electrical elements with bare hands To avoid potential shock hazards: ■ ■ ■ ■ ■ ■ Do not remove the enclosure with the adapter plugged to mains. Do not manipulate the circuits and/or components with enclosure removed and adapter powered. Do not touch any component from the boards when it is plugged into the mains. Do not carry out any installation, maintenance, or (re)configuration work during a thunderstorm. Do not connect or disconnect any power cables during a thunderstorm. For installation in a hot-plug system, observe the safety instructions specific to this system. Read the relevant documentation. MaxLinear, Inc. 5966 La Place Court, Suite 100 Carlsbad, CA 92008 760.692.0711 p. 760.444.8598 f. www.maxlinear.com The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by MaxLinear, Inc. MaxLinear, Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this guide. Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced into, stored in, or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the express written permission of MaxLinear, Inc. Maxlinear, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless MaxLinear, Inc. receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of MaxLinear, Inc. is adequately protected under the circumstances. MaxLinear, Inc. may have patents, patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from MaxLinear, Inc., the furnishing of this document does not give you any license to these patents, trademarks, copyrights, or other intellectual property. MaxLinear, the MaxLinear logo, and any MaxLinear trademarks, MxL, Full-Spectrum Capture, FSC, G.now, AirPHY and the MaxLinear logo are all on the products sold, are all trademarks of MaxLinear, Inc. or one of MaxLinear’s subsidiaries in the U.S.A. and other countries. All rights reserved. Other company trademarks and product names appearing herein are the property of their respective owners. © 2018 MaxLinear, Inc. All rights reserved.
RD-HNPLC-2DW920KIT01 价格&库存

很抱歉,暂时无法提供与“RD-HNPLC-2DW920KIT01”相匹配的价格&库存,您可以联系我们找货

免费人工找货