0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SKY13286-359LF_09

SKY13286-359LF_09

  • 厂商:

    SKYWORKS(思佳讯)

  • 封装:

  • 描述:

    SKY13286-359LF_09 - 0.1-6.0 GHz High Isolation SPDT Absorptive Switch - Skyworks Solutions Inc.

  • 数据手册
  • 价格&库存
SKY13286-359LF_09 数据手册
DATA SHEET SKY13286-359LF: 0.1-6.0 GHz High Isolation SPDT Absorptive Switch Applications • GSM, PCS, WCDMA base stations • 2.4 and 5.8 GHz ISM devices • Wireless local loops CBL J1 50 CBL Features • Single, positive voltage control: 0 to 3 and 0 to 5 V • High isolation 64 dB at 1 GHz and 2 GHz • Integrated silicon CMOS driver • Absorptive • Small, QFN (16-pin, 4 x 4 mm) Pb-free package (MSL1, 260 °C per JEDEC J-STD-020) Skyworks offers lead (Pb)-free, RoHS (Restriction of Hazardous Substances) compliant packaging. VDD 50 CBL J2 RFC Decoder VCTL S1595 Figure 1. SKY13286-359LF Block Diagram Description The SKY13286-359LF is a GaAs pHEMT FET high-isolation, absorptive switch. The device is an ideal component for base station applications in which synthesizer isolation is critical. The device is provided in a 4 x 4 mm, 16-pin Quad Flat No-Lead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 1 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH GND GND GND 14 16 15 13 GND VDD VCTL RFC GND 1 2 12 11 J1 GND GND J2 3 4 10 9 5 6 7 8 GND GND GND Pin # 9 10 Figure 2. SKY13286-359LF Pinout – 16-Pin QFN (Top View) Table 1. SKY13286-359LF Signal Descriptions Pin # 1 2 VDD VCTL Name Description DC power supply DC switch control pin. Switches insertion loss state from RFC to J1 or J2 (see Table 5). RF input Ground Ground Ground Ground Ground Name J2 GND RF output 2 Ground Description 3 4 5 6 7 8 RFC GND GND GND GND GND 11 12 13 14 15 16 GND GND J1 GND GND GND GND Ground RF output 1 Ground Ground Ground Ground Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13286-359LF are provided in Table 2. Recommended operating conditions are specified in Table 3 and electrical specifications are provided in Table 4. Typical performance characteristics of the SKY13286-359LF are illustrated in Figures 3 through 9. The state of the SKY13286-359LF is determined by the logic provided in Table 5. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 2 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 2. SKY13286-359LF Absolute Maximum Ratings Parameter Supply voltage RF input power @ >500 MHz Operating temperature Storage temperature Note: Symbol VDD VI TOP TSTG Minimum 2.7 Typical Maximum 5.5 Units V W °C °C 1 –40 –65 +95 +150 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. Recommended Operating Conditions Parameter Switching characteristics: Rise, fall On/off Video feedthrough Symbol Test Condition 10/90% or 90/10% RF 50% control to 90/10% RF TRISE = 3 ns, measurement bandwidth = 500 MHz PINPUT IP3 VDD = 3V, 0.7-2.0 GHz VDD = 5 V, 0.7-2.0 GHz For 2-tone input power, +8 dBm/tone, 1 MHz spacing: VDD = 3.3 V, 0.7-1.0 GHz VDD = 5.0 V, 0.7-1.0 GHz VDD = 3.3 V, 1.0-2.0 GHz VDD = 5.0 V, 1.0-2.0 GHz Control voltage (Note 1): Low High Supply current Control current Supply voltage VCTL_LOW VCTL_HIGH VDD = 5 V VCTL = low or high 2.7 5 5.0 +45 +45 0 2.7 +49 +47 +43 +46 0.5 VDD 100 dBm dBm dBm dBm V V μA μA V +26 Min Typical 30 50 Max Units ns ns 25 +23 +30 mV dBm dBm Input power for 1 dB compression 3rd Order Intercept Point Note 1: VDD must be applied before a VCTL high signal. A latch-up condition may occur if a logic high signal is applied before the VDD voltage. Control voltages switch the VDD voltage to the GaAs switch. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 3 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 4. SKY13286-359LF Electrical Specifications (Note 1) (VCTL = 0 V/3 V, VDD = 5 V, TOP = +25 °C, PINPUT = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Insertion loss Symbol Test Condition 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 60 58 55 40 10 15 13 10 10 12 12 11 Min Typical 0.8 0.8 1.0 1.5 62 62 58 42 22 22 18 12 12 15 15 13 Max 1.10 1.25 1.35 1.80 Units dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB Isolation Return loss (insertion loss state) (Note 2) Return loss (isolation state) (Note 2) Note 1: Performance is guaranteed only under the conditions listed in this Table and is not guaranteed over the full operating or storage temperature ranges. Operation at elevated temperatures may reduce reliability of the device. Note 2: Lower frequency return loss is dependent on DC blocks. Typical Performance Characteristics (VCTL = 0 V/3 V, VDD = 5 V, TOP = +25 °C, PINPUT = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) 0 –0.5 –1.0 0 –10 –20 J1 J2 Insertion Loss (dB) Isolation (dB) J1 J2 –1.5 –2.0 –2.5 –3.0 –3.5 –4.0 –4.5 –5.0 0 1 2 3 4 5 6 –30 –40 –50 –60 –70 –80 0 1 2 3 4 5 6 Frequency (GHz) Figure 3. Insertion Loss vs Frequency Frequency (GHz) Figure 4. Isolation v s Frequency Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 4 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 0 –5 0 –5 J1 |S11| J2 |S11| J1 |S22| J2 |S22| –10 Return Loss (dB) –15 –20 –25 –30 –35 –40 –45 0 1 2 3 4 5 6 J1 |S11| J2 |S11| J1 |S22| J2 |S22| Return Loss (dB) –10 –15 –20 –25 –30 0 1 2 3 4 5 6 Frequency (GHz) Figure 5. Return Loss vs Frequency (Insertion Loss State) 0 –10 –20 J1-J2 J2-J1 0 –0.2 Frequency (GHz) Figure 6. Return Loss vs Frequency (Isolation State) Insertion Loss (dB) –0.4 –0.6 –0.8 –1.0 –1.2 –1.4 –1.6 –1.8 3.0 V 3.3 V 5.0 V Isolation (dB) –30 –40 –50 –60 –70 –80 0 1 2 3 4 5 6 0 +4 +8 +12 +16 +20 +24 +28 +32 Frequency (GHz) Figure 7. Output to Output Isolation +55 Input Power (dBm) Figure 8. Insertion Loss vs Input Power Over Voltage +50 IP3 (dBm) +45 +40 0.7-1.0 GHz 1.0-2.0 GHz +35 +30 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 Supply Voltage (V) Figure 9. IP3 vs VDD Supply Voltage Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 5 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 5. SKY13286-359LF Truth Table VCTL 0 1 RFC to J1 Insertion loss Isolation RFC to J2 Isolation Insertion loss Evaluation Board Description The SKY13286-359LF Evaluation Board is used to test the performance of the SKY13286-359LF SPDT absorptive switch. An assembly drawing for the Evaluation Board is shown in Figure 10. Package and Handling Information Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. THE SKY13286-359LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 °C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. For packaging details, refer to the Skyworks Application Note, Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation, document number 200083. Package Dimensions The PCB layout footprint for the SKY13286-359LF is shown in Figure 11. Typical case markings are noted in Figure 12. Package dimensions for the 16-pin QFN are shown in Figure 13, and tape and reel dimensions are provided in Figure 14. GND VP VDD J2 VCTL VCTL 1 ?? J1 RFC ?? J3 J1 CBLK J2 Through ?? ?? Through CBL = 47 pF capacitor (5 places) S1597 Figure 10. SKY13286-359LF Evaluation Board Assembly Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 6 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 8X 1.600 0.325 Typ Solderable Area Pin 1 R0.200 8X 1.600 2X 1.350 Package Outline 0.30 2X 1.350 0.650 Pitch See Detail A For Solderable Area Solderable Area 0.55 Detail A S1598 Figure 11. SKY13286-359LF PCB Layout Footprint Pin 1 Indicator S286 XXXX YWW Skyworks P/N Skyworks GaAs Die Lot # Date Code Y = Calendar Year WW = Week Figure 12. Typical Case Markings Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 7 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 0.20 Ref 4.00 0.02 +0.03/–0.02 Pin 1 Indicator Seating Plane 2.70 +0.10/–0.15 Exposed Pad 1.35 +0.05/–0.075 Pin 1 Ind. 0.20 Min. Typ. 0.65 4.00 0.325 2.70 +0.10/–0.15 1.35 +0.05/–0.075 0.40 ± 0.10 0.90 ± 0.10 0.30 ± 0.05 All dimensions are in millimeters S1596 Figure 13. SKY13286-359LF 16-Pin QFN Package Dimensions 8.00 ± 0.10 1.13 ± 0.10 Reference Pin Indicator 4.00 ± 0.10 ∅1.50 ± 0.10 2.00 ± 0.05 1.75 ± 0.10 B 5.50 ± 0.05 A 4.25 ± 0.10 A 10o Max 0.229 ± 0.02 B ∅1.50 ± 0.25 B Notes: 1. Carrier tape material: black conductive polycarbonate or polysterene 2. Cover tape material: transparent conductive PSA 3. Cover tape size: 9.3 mm width 4. All measurements are in millimeters 4.25 ± 0.10 10o Max A S1056 Figure 14. SKY13286-359LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 8 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E 12.00 +0.30/–0.10 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Ordering Information Model Name SKY13286-359LF SPDT Absorptive Switch Manufacturing Part Number SKY13286-359LF (Pb-free package) Evaluation Board Part Number SK39110, rev. 2 Copyright © 2009 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 9
SKY13286-359LF_09 价格&库存

很抱歉,暂时无法提供与“SKY13286-359LF_09”相匹配的价格&库存,您可以联系我们找货

免费人工找货