DATA SHEET
SKY13370-374LF: 0.5 to 6.0 GHz SPDT Switch,
50 Ω Terminated
Applications
RF1
WiMAX 802.16
Dual-band WLANs (802.11 a/b/g/n)
LTE/4G systems
RF2
50 Ω
50 Ω
Features
50 Ω matched RF ports in all states
Low insertion loss: 0.7 dB @ 2.5 GHz
High isolation: 31 dB @ 2.5 GHz
IP1dB: +39 dBm
201408-001
Small DFN (6-pin, 1.5 x 1.5 mm) package
(MSL1, 260 C per JEDEC J-STD-020)
RFC
Figure 1. SKY13370-374LF Block Diagram
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04-0074.
Description
The SKY13370-374LF is a GaAs pHEMT single-pole, double-throw
(SPDT) high power switch with 50 Ω terminated outputs. The
high-linearity performance and low insertion loss achieved by the
SKY13370-374LF make it an ideal choice for WiMAX and higher
power WLAN applications such as access points.
The switch is manufactured in a compact, 1.5 x 1.5 mm, 6-pin
Dual Flat No-Lead (DFN) package.
V1
1
6
RF1
RFC
2
5
GND
V2
3
4
RF2
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
201408-002
Figure 2. SKY13370-374LF Pinout
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201408G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 15, 2018
1
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Table 1. SKY13370-374LF Signal Descriptions
Pin
Name
Pin
Name
Description
RF output: 50 Ω terminated when in
isolation state. Must be DC blocked.
DC control voltage. A logic high voltage
enables an insertion loss path between the
RFC and RF1 pins.
4
RF2
RFC
RF common input. Must be DC blocked.
5
GND
Ground
V2
DC control voltage. A logic high voltage
enables an insertion loss path between the
RFC and RF2 pins.
RF1
RF output: 50 Ω terminated when in
isolation state. Must be DC blocked.
1
V1
2
3
Description
6
Functional Description
Electrical and Mechanical Specifications
Switching is controlled by two control voltage inputs, V1 and V2
(pins 1 and 3, respectively). Depending on the logic voltage level
applied to the control pins, the RFC pin is connected to one of the
two switched RF outputs, RF1 or RF2, using a low insertion loss
path, while the path between the RFC pin and the other RF pin is
in a high isolation state.
The absolute maximum ratings of the SKY13370-374LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
DC blocking capacitors are required on all RF ports of the switch.
The value of the capacitors determines the low frequency
operation. The isolated RF output is internally terminated to 50 Ω.
Typical performance characteristics of the SKY13370-374LF are
illustrated in Figures 3 through 6.
The state of the SKY13370-374LF is determined by the logic
provided in Table 4.
Table 2. SKY13370-374LF Absolute Maximum Ratings1
Parameter
Symbol
Minimum
Maximum
Units
6
V
+40
dBm
+125
C
Control voltage
VCTL
Input power
PIN
Storage temperature
TSTG
-40
Operating temperature
TOP
-40
+85
C
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at
or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
January 15, 2018 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201408G
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Table 3. SKY13370-374LF Electrical Specifications1
(VCTL = 0 V and +3.0 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, CBLK = 47 pF, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typ
Max
Units
0.70
0.80
1.15
0.80
0.95
1.30
dB
dB
dB
RF Specifications
RFC to RF1 or RF2:
Insertion loss
IL
0.50 to 2.70 GHz
2.70 to 3.80 GHz
3.80 to 5.85 GHz
RFC to RF1 or RF2:
Isolation
Iso
Input return loss (“on” state)
|S11|
dB
dB
dB
dB
29.0
29.0
26.0
18.0
31.0
31.0
29.0
24.0
11
14
dB
12
15
15
dB
dB
dB
+36
+39
dBm
dBm
55
55
55
dB
dB
dB
+75
+75
+75
+75
+75
dBc
dBc
dBc
dBc
dBc
0.9 GHz
1.8 GHz
2.4 GHz
3.8 GHz
5.8 GHz
+75
+75
+75
+75
+75
dBc
dBc
dBc
dBc
dBc
50% VCTL to 90/10% RF
90/10% RF or 10/90% RF
100
100
250
250
3.0
5.0
V
45
85
µA
0.50 to 2.40 GHz
2.40 to 2.50 GHz
2.50 to 3.80 GHz
3.80 to 5.85 GHz
RFC or RF1 or RF2,
0.5 to 6.0 GHz
32.5
Isolated output RF1 or
RF2:
Input return loss (“off” state)
|S11|
1 dB input compression point
IP1dB
2.30 to 2.70 GHz
3.30 to 3.80 GHz
4.90 to 5.85 GHz
500 to 6000 MHz:
Third order input intercept point
IIP3
VCTL = 1.8 V
VCTL = 3.0 V
PIN = +25 dBm/tone,
ΔF = 1 MHz,
VCTL = 3.0 V:
2.4 GHz
3.8 GHz
5.8 GHz
PIN = +25 dBm,
VCTL = 3.0 V:
2nd harmonic
2fo
0.9 GHz
1.8 GHz
2.4 GHz
3.8 GHz
5.8 GHz
PIN = +25 dBm,
VCTL = 3.0 V:
3rd harmonic
3fo
Switching speed
ns
ns
DC Specifications
Control voltage
VCTL
Control current
ICC
1.8
1 Performance is guaranteed only under the conditions listed in this table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201408G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice January 15, 2018
3
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Typical Performance Characteristics
(VCTL = 0 V and +3.0 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [Zo] = 50 Ω, CBLK = 47 pF, Unless Otherwise Noted)
0
0
–5
RFC to RF1
RFC to RF2
–10
Isolation (dB)
–0.6
–0.8
–1.0
–1.2
–1.4
–1.6
–1.8
–2.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
RFC to RF1 (RFC to RF2 in Insertion Loss State)
RFC to RF2 (RFC to RF1 in Insertion Loss State)
–15
–20
–25
–30
201408-004
–0.4
201408-003
Insertion Loss (dB)
–0.2
–35
–40
0.5
6.0
1.0
1.5
2.0
2.5
Frequency (GHz)
3.0
3.5
4.0
4.5
5.0
5.5
6.0
Frequency (GHz)
Figure 3. Typical Insertion Loss vs Frequency
Figure 4. Typical Isolation vs Frequency
0
–5
0
–15
–20
–25
201408-006
–30
–35
–40
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
RF1 Return Loss (RFC to RF2 in Insertion Loss State)
RF2 Return Loss (RFC to RF1 in Insertion Loss State)
–5
Return Loss (dB)
Return Loss (dB)
–10
RFC Return Loss (RFC to RF1 in Insertion Loss State)
RF1 Return Loss (RFC to RF1 in Insertion Loss State)
RFC Return Loss (RFC to RF2 in Insertion Loss State)
RF2 Return Loss (RFC to RF2 in Insertion Loss State)
4.5
Frequency (GHz)
Figure 5. Return Loss vs Frequency
(Insertion Loss State)
5.0
5.5
6.0
–10
–15
–20
–25
–30
–35
–40
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Frequency (GHz)
Figure 6. Return Loss vs Frequency
(Isolation State)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
January 15, 2018 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201408G
5.0
5.5
6.0
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Table 4. SKY13370-374LF Truth Table1
V1 (Pin 1)
V2 (Pin 3)
Insertion Loss State
1
0
RFC to RF1
0
1
RFC to RF2
1 “1” = +1.8 V to +5.0 V. “0” = 0 V to +0.2 V. Any state other than described in this Table places the switch into an undefined state. An undefined state will not damage the device.
Evaluation Board Description
Package and Handling Information
The SKY13370-374LF Evaluation Board is used to test the
performance of the SKY13370-374LF SPDT Switch. An Evaluation
Board schematic diagram is provided in Figure 7. An assembly
drawing for the Evaluation Board is shown in Figure 8.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The PCB layout footprint for the SKY13370-374LF is provided in
Figure 9. Typical part markings are shown in Figure 10. Package
dimensions are shown in Figure 11, and tape and reel dimensions
are provided in Figure 12.
DC Control
Voltage
RF Common
Input
CBL
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
1
V1
RF1
6
2
RFC
GND
5
RF2
4
3
DC Control
Voltage
The SKY13370-374LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
V2
CBL
RF Output
CBL
RF Output
CBL = 47 pF for >1 GHz operation. Increase
value for lower frequency operation.
Exposed ground paddle should be grounded
for best performance.
201408-007
Figure 7. SKY13370-374LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201408G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice January 15, 2018
5
DATA SHEET • SKY13370-374LF: SPDT SWITCH
RFC
V2
C BL
V1
RF2
C BL
C BL
RF1
201408-008
Figure 8. SKY13370-374LF Evaluation Board Assembly Diagram
6X 0.55
0.15 X 45o
6X 0.35
6X 0.25
0.60
0.50 Pitch
1.20
7X Exposed Solder
Area
0.05
0.20
0.35
0.70
201408-009
Figure 9. SKY13370-374LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
6
January 15, 2018 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201408G
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Pin 1
Indicator
Skyworks
Part Number
201408-010
Figure 10. Typical Part Markings
(Top View)
201804-011
Figure 11. SKY13370-374LF 6-Pin DFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201408G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice January 15, 2018
7
DATA SHEET • SKY13370-374LF: SPDT SWITCH
4.00 ± 0.10
01.50± 0.10
2.00 ± 0.05
0.20 ± 0.02 (T)
1.75 ± 0.10
A
3.50 ± 0.05
1.78 ± 0.05 (Bo)
B
A
B
0.69 ± 0.05 (Ko)
00.50± 0.05
Detail B
5o Max
1.78 ± 0.05 (Ao)
Detail A
Notes:
1. Carrier tape: black conductive polycarbonate or polystyrene.
2. Cover tape material: transparent conductive PSA.
3. Cover tape size: 5.4 mm width.
4. All measurements are in millimeters.
5. Pin 1 orientation is in lower left corner for SOT-666 packages.
Pin 1 orientation is in upper left corner for 1.5 x 1.5 mm
MLPD, QFN, and DFN packages.
Figure 12. SKY13370-374LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
8
January 15, 2018 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201408G
201408-012
8.00 +0.30/–0.10
Pin 1
5o Max
DATA SHEET • SKY13370-374LF: SPDT SWITCH
Ordering Information
Product Description
SKY13370-374LF: SPDT Switch
Product Part Number
SKY13370-374LF
Evaluation Board Part Number
SKY13370-374LF-EVB
Copyright © 2011, 2013, 2018 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names
are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201408G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice January 15, 2018
9