0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SKY13410-365LF

SKY13410-365LF

  • 厂商:

    SKYWORKS(思佳讯)

  • 封装:

    VFQFN20_EP

  • 描述:

    IC RF SWITCH 2.15GHZ 20QFN

  • 数据手册
  • 价格&库存
SKY13410-365LF 数据手册
DATA SHEET SKY13410-365LF: 0.25 - 2.15 GHz 4x2 Switch Matrix with Tone/Voltage Decoder Applications • DBS switching systems • Cable TV/modems Features • Broadband frequency range: 0.25 to 2.15 GHz • Tone and voltage, or mode control switching • High isolation: 40 dB typical @ 900 MHz • Four RF inputs, two RF outputs • Low current consumption: 1.5 mA typical @ 5 V • Miniature QFN (20-pin, 4 x 4 mm) package (MSL1, 260 °C per JEDEC J-STD-020) Figure 1. SKY13410-365LF Block Diagram Description The SKY13410-365LF is a four-input to two-output switch matrix intended for Direct Broadcast Satellite (DBS) switching and cable TV/modem applications. The SKY13410-365LF enables 16 states, directing any of the four inputs to either of the two outputs. Switch states are selected using tone and voltage signals together with logic levels applied to mode control inputs. The switch can operate over a temperature range of –40 °C to +85 °C. The SKY13410-365LF is manufactured in a compact, 4 x 4 mm, 20-pin Quad Flat No-Lead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 1 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 2. SKY13410-365LF Pinout – 20-Pin QFN (Top View) Table 1. SKY13410-365LF Signal Descriptions Pin # Name Description Signal Type I/O Pin # Name Description Signal Type 1 OUT1 RF channel output #1, 250 to 2150 MHz RF O 11 I3 RF input #3, 250 to 2150 MHz RF I 2 T1 Tone detector input #1 AC I 12 N/C No connection – – 3 V1 Voltage detector input #1 DC I 13 V2 Voltage detector input #2 DC I 4 N/C No connection – – 14 T2 Tone detector input #2 AC I 5 I1 RF input #1, 250 to 2150 MHz RF I 15 OUT2 RF channel output #2, 250 to 2150 MHz RF O 6 GND Ground GND – 16 N/C No connection. This pin must be left open. DC – 7 I2 RF input #2, 250 to 2150 MHz RF I 17 B2 Mode control input #2 DC I 8 GND Ground GND – 18 B1 Mode control input #1 DC I 9 I4 RF input #4, 250 to 2150 MHz RF I 19 P0 Mode control input #0 10 GND Ground GND – 20 VDD Supply voltage, +3.3 to +5.0 V DC I Technical Description The SKY13410-365LF is controlled by a pair of DC voltage levels applied to V1 (pin 3) and V2 (pin 13) combined with 22 kHz signal levels applied to T1 (pin 2) and T2 (pin 14). These signals are supplied from a set top box, receiver, etc., that is controlled by the user. The configuration of the switch, itself, is controlled by the logic levels applied to P0 (pin 19), B1 (pin 18), and B2 (pin 17). A pair of SKY13410-365LF 4x2 switches can be used to form a 4x4 switch. Figure 3 shows a suggested implementation in which one of the 4x2 switches is mounted on the top side of a printed circuit board, with the second 4x2 switch mounted on the back side of the printed circuit board. The four RF input signals, which may come from a variety of sources but are shown here coming from four separate low-noise block converters, are split and routed directly to the inputs of the top-side switch and through vias to the inputs of the back-side switch. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 2 I/O January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 3. Suggested Implementation of Two 4x2 Switches With each of the configuration inputs (P0, B1, and B2) of the topside switch held at 0 V, and each of the configuration inputs of the back-side switch held at VDD, the same logic controls from each of the four receivers selects any specific input signal. For example, if the user of receiver 1 wants to receive the signal from antenna 1, polarization 1, through low-noise block A, that receiver must send a 22 kHz tone and a control voltage greater than the threshold voltage to switch 1. If the user of receiver 3 also wants to receive the signal from antenna 1, polarization 1, through low-noise block A, that receiver must also send a 22 kHz tone and a control voltage greater than the threshold voltage to switch 2. Other logic configurations are possible. Refer to the truth Tables in this Data Sheet. Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13410-365LF are provided in Table 2. Electrical specifications are provided in Table 3. Typical performance characteristics of the SKY13410-365LF are illustrated in Figures 4 through 9. The state of the SKY13410-365LF is determined by the logic provided in Tables 4 through 13. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 3 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 2. SKY13410-365LF Absolute Maximum Ratings Parameter Supply voltage Symbol Minimum Typical Maximum Units 5.5 V 5.5 V VDD Mode select input voltage (must not exceed VDD) Polarization input control voltage RF input power PIN Storage temperature TSTG Operating temperature TOP Note: 21 V +15 dBm –65 +150 °C –40 +85 °C Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. SKY13410-365LF Electrical Specifications (Note 1) (1 of 2) (VDD = 0 and +3.3 to +5.0 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 0.25 to 0.95 GHz 0.95 to 2.15 GHz 7.5 9.0 8.0 10.0 dB dB 0.25 to 0.95 GHz 0.95 to 2.15 GHz 0.7 2.0 1.0 3.0 dB dB RF Switch Specifications Insertion loss IL Insertion loss flatness Isolation Iso Normalized to insertion loss 0.25 to 0.95 GHz 0.95 to 2.15 GHz Input return loss 38 28 40 30 dB dB 10 8 15 10 dB dB 0.25 to 0.95 GHz I1, I2, I3, I4 OUT1, OUT2 1 dB Input Compression Point IP1dB 0.25 to 0.95 GHz +12 dBm Polarization select input current IPT1, IPT2 VP1 and VP2 = 21 V 200 μA Polarization select threshold voltage VTP1, VTP2 Polarization switching time TSPOL Tone frequency TF1, TF2 @ 500 mVp-p Tone threshold voltage TT1, TT2 @ 22 kHz with 10 nF external DC blocking capacitor Tone input impedance TZIN1, TZIN2 @ 22 kHz including external 10 nF series blocking capacitor Tone/Voltage Detector Specifications 14 15 16 V μs 0.9 7 22 800 kHz 100 170 900 mVp-p 2 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 4 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B kΩ DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 3. SKY13410-365LF Electrical Specifications (Note 1) (2 of 2) (VDD = 0 and +3.3 to +5.0, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units Mode Control Specifications 0 V ≤ VCTRL ≤ VDD Control input current IDIG Control input low logic level VLOW 0 Control input high logic level VHIGH VDD – 1 Supply voltage VDD 3.3 Supply current IDD μA 1 1 V VDD VDD + 0.5 V 4.2 5.0 Power Supply 1.5 V mA Note 1: Performance is guaranteed only under the conditions listed in this Table. Note 2: The SKY13410-365LF detects 22 kHz signaling amplitudes across the full specified range of the DiSEqC bus functional specification. Anticipated Performance Characteristics (VDD = +3.3 to +5.0, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted) Figure 4. I1 to OUT1 and I1 to OUT2 Paths for States 0 to 15 Figure 5. I2 to OUT1 and I2 to OUT2 Paths for States 0 to 15 Figure 6. I3 to OUT1 and I3 to OUT2 Paths for States 0 to 15 Figure 7. I4 to OUT1 and I4 to OUT2 Paths for States 0 to 15 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 5 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 8. I1, I2, I3, and I4 for States 0 to 15 Figure 9. OUT1 and I2 to OUT2 Paths for States 0 to 15 Table 4. SKY13410-365LF Truth Table: Mode Control Summary (1 of 2) Mode Paths Mode P0 (Pin 19) B1 (Pin 18) B2 (Pin 17) I1 (Pin 5) I2 (Pin 7) I4 (Pin 9) I3 (Pin 11) 0 0 0 0 A B C D 1 0 0 1 A B D C 2 0 1 0 B A C D 3 0 1 1 B A D C Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 6 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 4. SKY13410-365LF Truth Table: Mode Control Summary (2 of 2) Mode Paths Mode P0 (Pin 19) B1 (Pin 18) B2 (Pin 17) I1 (Pin 5) I2 (Pin 7) I4 (Pin 9) I3 (Pin 11) 4 1 0 0 C D A B 5 1 0 1 C D B A 6 1 1 0 D C A B 7 1 1 1 D C B A Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 7 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 5. SKY13410-365LF Truth Table: General Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) V2 (Pin 13) Signal Paths 1 No Tone VLOW No Tone VLOW 2 No Tone VLOW No Tone VHIGH D → OUT1, B → OUT2 3 No Tone VLOW 22 kHz Tone VLOW D → OUT1, C → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH D → OUT1, A → OUT2 5 No Tone VHIGH No Tone VLOW B → OUT1, D → OUT2 6 No Tone VHIGH No Tone VHIGH B → OUT1, B → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW B → OUT1, C → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH B → OUT1, A → OUT2 9 22 kHz Tone VLOW No Tone VLOW C → OUT1, D → OUT2 10 22 kHz Tone VLOW No Tone VHIGH C → OUT1, B → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW C → OUT1, C → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH C → OUT1, A → OUT2 13 22 kHz Tone VHIGH No Tone VLOW A → OUT1, D → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH A → OUT1, B → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW A → OUT1, C → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH A → OUT1, A → OUT2 D → OUT1, D → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 8 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 6. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 0 (000): P0 = B1 = B2 = 0 V (Default State) Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I3 → OUT1, I3 → OUT2 2 No Tone VLOW No Tone VHIGH I3 → OUT1, I2 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I3 → OUT1, I4 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I3 → OUT1, I1 → OUT2 5 No Tone VHIGH No Tone VLOW I2 → OUT1, I3 → OUT2 6 No Tone VHIGH No Tone VHIGH I2 → OUT1, I2 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I2 → OUT1, I4 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I2 → OUT1, I1 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I4 → OUT1, I3 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I4 → OUT1, I2 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I4 → OUT1, I4 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I4 → OUT1, I1 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I1 → OUT1, I3 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I1 → OUT1, I2 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I1 → OUT1, I4 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I1 → OUT1, I1 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 9 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 7. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 1 (001): P0 = B1 = 0 V, B2 = VDD Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I4 → OUT1, I4 → OUT2 2 No Tone VLOW No Tone VHIGH I4 → OUT1, I2 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I4 → OUT1, I3 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I4 → OUT1, I1 → OUT2 5 No Tone VHIGH No Tone VLOW I2 → OUT1, I4 → OUT2 6 No Tone VHIGH No Tone VHIGH I2 → OUT1, I2 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I2 → OUT1, I3 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I2 → OUT1, I1 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I3 → OUT1, I4 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I3 → OUT1, I2 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I3 → OUT1, I3 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I3 → OUT1, I1 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I1 → OUT1, I4 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I1 → OUT1, I2 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I1 → OUT1, I3 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I1 → OUT1, I1 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 10 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 8. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 2 (010): P0 = 0 V, B1 = VDD, B2 = 0 V Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I3 → OUT1, I3 → OUT2 2 No Tone VLOW No Tone VHIGH I3 → OUT1, I1 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I3 → OUT1, I4 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I3 → OUT1, I2 → OUT2 5 No Tone VHIGH No Tone VLOW I1 → OUT1, I3 → OUT2 6 No Tone VHIGH No Tone VHIGH I1 → OUT1, I1 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I1 → OUT1, I4 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I1 → OUT1, I2 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I4 → OUT1, I3 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I4 → OUT1, I1 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I4 → OUT1, I4 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I4 → OUT1, I2 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I2 → OUT1, I3 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I2 → OUT1, I1 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I2 → OUT1, I4 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I2 → OUT1, I2 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 11 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 9. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 3 (011): P0 = 0 V, B1 = B2 = VDD Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I4 → OUT1, I4 → OUT2 2 No Tone VLOW No Tone VHIGH I4 → OUT1, I1 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I4 → OUT1, I3 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I4 → OUT1, I2 → OUT2 5 No Tone VHIGH No Tone VLOW I1 → OUT1, I4 → OUT2 6 No Tone VHIGH No Tone VHIGH I1 → OUT1, I1 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I1 → OUT1, I3 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I1 → OUT1, I2 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I3 → OUT1, I4 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I3 → OUT1, I1 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I3 → OUT1, I3 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I3 → OUT1, I2 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I2 → OUT1, I4 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I2 → OUT1, I1 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I2 → OUT1, I3 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I2 → OUT1, I2 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 12 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 10. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 4 (100): P0 = VDD, B1 = B2 = 0 V Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I2 → OUT1, I2 → OUT2 2 No Tone VLOW No Tone VHIGH I2 → OUT1, I3 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I2 → OUT1, I1 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I2 → OUT1, I4 → OUT2 5 No Tone VHIGH No Tone VLOW I3 → OUT1, I2 → OUT2 6 No Tone VHIGH No Tone VHIGH I3 → OUT1, I3 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I3 → OUT1, I1 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I3 → OUT1, I4 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I1 → OUT1, I2 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I1 → OUT1, I3 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I1 → OUT1, I1 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I1 → OUT1, I4 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I4 → OUT1, I2 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I4 → OUT1, I3 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I4 → OUT1, I1 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I4 → OUT1, I4 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 13 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 11. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 5 (101): P0 = VDD, B1 = 0 V, B2 = VDD Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I2 → OUT1, I2 → OUT2 2 No Tone VLOW No Tone VHIGH I2 → OUT1, I4 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I2 → OUT1, I1 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I2 → OUT1, I3 → OUT2 5 No Tone VHIGH No Tone VLOW I4 → OUT1, I2 → OUT2 6 No Tone VHIGH No Tone VHIGH I4 → OUT1, I4 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I4 → OUT1, I1 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I4 → OUT1, I3 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I1 → OUT1, I2 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I1 → OUT1, I4 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I1 → OUT1, I1 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I1 → OUT1, I3 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I3 → OUT1, I2 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I3 → OUT1, I4 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I3 → OUT1, I1 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I3 → OUT1, I3 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 14 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 12. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 6 (110): P0 = B1 = VDD, B2 = 0 V Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I1 → OUT1, I1 → OUT2 2 No Tone VLOW No Tone VHIGH I1 → OUT1, I3 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I1 → OUT1, I2 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I1 → OUT1, I4 → OUT2 5 No Tone VHIGH No Tone VLOW I3 → OUT1, I1 → OUT2 6 No Tone VHIGH No Tone VHIGH I3 → OUT1, I3 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I3 → OUT1, I2 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I3 → OUT1, I4 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I2 → OUT1, I1 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I2 → OUT1, I3 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I2 → OUT1, I2 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I2 → OUT1, I4 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I4 → OUT1, I1 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I4 → OUT1, I3 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I4 → OUT1, I2 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I4 → OUT1, I4 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 15 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Table 13. SKY13410-365LF Truth Table: Tone and Voltage Controls Mode 7 (111): P0 = B1 = B2 = VDD Tone and Voltage Inputs (Note 1) State T1 (Pin 2) V1 (Pin 3) T2 (Pin 14) 1 No Tone VLOW No Tone VLOW I1 → OUT1, I1 → OUT2 2 No Tone VLOW No Tone VHIGH I1 → OUT1, I4 → OUT2 3 No Tone VLOW 22 kHz Tone VLOW I1 → OUT1, I2 → OUT2 4 No Tone VLOW 22 kHz Tone VHIGH I1 → OUT1, I3 → OUT2 5 No Tone VHIGH No Tone VLOW I4 → OUT1, I1 → OUT2 6 No Tone VHIGH No Tone VHIGH I4 → OUT1, I4 → OUT2 7 No Tone VHIGH 22 kHz Tone VLOW I4 → OUT1, I2 → OUT2 8 No Tone VHIGH 22 kHz Tone VHIGH I4 → OUT1, I3 → OUT2 V2 (Pin 13) Signal Paths 9 22 kHz Tone VLOW No Tone VLOW I2 → OUT1, I1 → OUT2 10 22 kHz Tone VLOW No Tone VHIGH I2 → OUT1, I4 → OUT2 11 22 kHz Tone VLOW 22 kHz Tone VLOW I2 → OUT1, I2 → OUT2 12 22 kHz Tone VLOW 22 kHz Tone VHIGH I2 → OUT1, I3 → OUT2 13 22 kHz Tone VHIGH No Tone VLOW I3 → OUT1, I1 → OUT2 14 22 kHz Tone VHIGH No Tone VHIGH I3 → OUT1, I4 → OUT2 15 22 kHz Tone VHIGH 22 kHz Tone VLOW I3 → OUT1, I2 → OUT2 16 22 kHz Tone VHIGH 22 kHz Tone VHIGH I3 → OUT1, I3 → OUT2 Note 1: “No Tone” = no 22 kHz tone present “22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p VLOW ≤ 14 V VHIGH ≥ 16 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 16 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Evaluation Board Description Package and Handling Information The SKY13410-365LF Evaluation Board is used to test the performance of the SKY13410-365LF 4x2 Switch Matrix. A recommended application schematic is provided in Figure 10. An assembly drawing for the Evaluation Board is shown in Figure 11. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Package Dimensions The PCB layout footprint for the SKY13410-365LF is provided in Figure 12. Typical case markings are shown in Figure 13. Package dimensions for the 20-pin QFN are shown in Figure 14, and tape and reel dimensions are provided in Figure 15. THE SKY13410-365LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 °C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. Figure 10. SKY13410-365LF Recommended Application Circuit Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 17 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 11. SKY13410-365LF Evaluation Board Assembly Diagram Figure 12. SKY13410-365LF PCB Layout Footprint (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 18 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 13. Typical Case Markings (Top View) Figure 14. SKY13410-365LF 20-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 19 DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Figure 15. SKY13410-365LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 20 January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX Ordering Information Model Name SKY13410-365LF 4x2 Switch Matrix Manufacturing Part Number SKY13410-365LF Evaluation Board Part Number SKY13410-365LF-EVB Copyright © 2011, 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012 21
SKY13410-365LF 价格&库存

很抱歉,暂时无法提供与“SKY13410-365LF”相匹配的价格&库存,您可以联系我们找货

免费人工找货