SKY65111-348LF

SKY65111-348LF

  • 厂商:

    SKYWORKS(思佳讯)

  • 封装:

    16-WFQFN裸露焊盘

  • 描述:

    IC AMP INGAP 600-1100MHZ 16QFN

  • 数据手册
  • 价格&库存
SKY65111-348LF 数据手册
DATA SHEET SKY65111-348LF: ISM 600–1100 MHz Band 2 Watt InGaP HBT Power Amplifier Features Optimized for 800–1100 MHz operation ● Output power greater than 33 dBm @915 MHz ● 3.5 V nominal operating voltage ● Integrated analog power control voltage, V APC = 0.1–2.8 V ● High PAE at maximum output power ● Ultrasmall, thermally enhanced micro lead frame package. ● Low current in standby mode of < 10 µA ● Available on tape and reel ● Available lead (Pb)-free and RoHS-compliant ● Block Diagram VCC2 16 GND 1 VCC2 15 GND 14 Open 13 12 RF OUT/VCC3 RF IN 2 11 RF OUT/VCC3 GND 3 10 RF OUT/VCC3 Description The SKY65111-348LF is a high-performance 3-stage, highpower amplifier IC designed for use in 600–1100 MHz ISM band applications such as automatic meter readers and RFID. It has an integrated analog power control voltage for achieving the desired output power levels. The IC is manufactured on an advanced InGaP HBT process. The SKY65111-348LF is packaged in a thermally enhanced, ultrasmall, micro lead frame package. VCC1 4 5 VAPC1 6 VAPC2 7 VREF 8 GND 9 RF OUT/VCC3 Package Dimensions 0.008 (0.20 mm) Ref. 0.118 (3.00 mm) Pin 1 Indicator 0.118 (3.00 mm) Seating Plane 0.001 (0.02 mm) ± 0.001 (+0.03 mm -0.02 mm) NEW Skyworks offers lead (Pb)-free, RoHS (Restriction of Hazardous Substances)-compliant packaging. 0.030 (0.75 mm) ± 0.002 (0.05 mm) (0.057 (1.45 mm) ± 0.004 (± 0.10 mm) 0.029 (0.73 mm) 0.029 (0.73 mm) Exposed Pad 0.059 (1.500 mm) 0.059 (1.500 mm) BUY NOW 0.057 (1.45 mm) ± 0.004 (±0.10 mm) 0.5 mm Pitch Innovation to GoTM Now available for purchase online. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 1 DATA SHEET • SKY65111-348LF Pin Assignments Pin 1, 3, 8, 14 2 4 5 6 7 9, 10, 11, 12 13 15, 16 Symbol GND RF IN VCC1 VAPC1 VAPC2 VREF RF OUT/ VCC3 OPEN VCC2 Description Connect this pin to the printed circuit board common via lowest possible impedance. RF input port. DC power supply input to the first gain stage. Power control voltage input to the first and second gain stages. Power control voltage input to the third gain stage. Control voltage input to bias control circuit. RF output ports and DC supply voltage inputs to third gain stage. No connection. Do not connect this pin to ground. DC power supply input to the second gain stage. Absolute Maximum Ratings Characteristic Supply voltage (VCC & VREF) Power control voltage (VAPC1 & VAPC2) RF input power Operating temperature Storage temperature Value 5.5 V 3.0 V 10 dBm -40 °C to +85 °C -65 °C to +85 °C Performance is guaranteed only under the conditions listed in the specifications table and is not guaranteed under the full range(s) described by the Absolute Maximum specifications. Exceeding any of the absolute maximum/minimum specifications may result in permanent damage to the device and will void the warranty. Each absolute maximum rating listed is an individual parameter. Basing and driving the amplifier with all absolute maximum ratings listed simultaneously may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, ESD (Electrostatic Discharge) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions must be employed at all times. General DC Electrical Specifications Parameter Supply voltage Power control voltage Power control range Power control current Leakage current Thermal resistance RTH IVAPC PIN < -30 dBm, VAPC1, 2 = 0.1 V 50 Symbol VCC VAPC Condition Min. 2.5 0 Typ. 3.5 2.7 45 5 10 Max. 5 2.8 Unit V V dB mA µA ° C/W Guaranteed Performance VCC = 3.5 V, VREF = 3.5 V, VAPC = 2.7 V, TA = 25 °C Parameter Critical gain Saturated power Symbol lS21l PSAT 915 MHz Condition 902–928 NHz, -30 dBm input Specification 36 min. 30 min. Unit dB dBm Guaranteed performance is as measured in the application’s PC board as defined in this data sheet. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 2 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF General RF Transmit Electrical Specifications Conditions: VCC = 3.5 V, VREF = 3.5 V, VAPC = 2.7 V, PIN = -30 dBm, TA = 25 °C Parameter Frequency range Gain Gain variation over frequency Input return loss Output return loss Quiescent current Output P1 dB Current consumption Saturated power @ 915 MHz Power added efficiency Second harmonic Third harmonic Ruggedness Symbol F lS21l lΔS21l lS11l lS22l ICQ P1 dB ICC PSAT PAE F2 F3 Small signal Small signal Small signal Small signal (No RF signal) CW Output P1 dB VCC = 3.5 V, VREF = 3.5 V, VAPC1, 2 = 2.7 V PSAT Output P1 dB Output P1 dB Output VSWR = 8:1, All phase angles, VCC = 5 V, PIN = -5 dBm, VAPC = 2.7 V VREF = 5 V Output VSWR = 8:1, All phase angles, VCC = 5 V, PIN = -10 dBm, VAPC = 2.7 V VREF = 5 V Condition Min. 902 40 0.3 -12 -15 0.25 29.5 0.7 33 50 -28 -38 No module damage or permanent performance degradation -36 dBm Typ. Max. 928 Unit MHz dB dB dB dB A dBm A dBm % dBm dBm Stability Conditions: VCC = 3.5 V, VREF = 3.5 V, VAPC = 2.7 V, PIN = -30 dBm, TA = 25 °C Parameter Frequency range Gain Gain variation over frequency Input return loss Output return loss Output P1 dB Quiescent current Current consumption Second harmonic Third harmonic Ruggedness Symbol F lS21l lΔS21l lS11l lS22l P1 dB ICQ ICC F2 F3 Small signal Small signal Small signal Smal signal CW (No RF signal) Output P1 dB Output P1 dB Output P1 dB Output VSWR = 8:1, All phase angles, VCC = 5 V, PIN = -5 dBm, VAPC = 2.7 V VREF = 5 V Output VSWR = 8:1, All phase angles, VCC = 5 V, PIN = -10 dBm, VAPC = 2.7 V, VREF = 5 V PSAT PAE PSAT PAE VCC = 3.5 V, VREF = 3.5 V, VAPC1, 2 = 2.7 V PSAT VCC = 3.5 V, VREF = 3.5 V, VAPC1, 2 = 2.7 V PSAT Condition Min. 800 39.5 1.0 -11 -8 27 0.25 0.7 -17 -35 No module damage or permanent performance degradation 36 32 45 30 40 dBm dBm % dBm % Typ. Max. 1100 Unit MHz dB dB dB dB dBm A A dBm dBm Stability Saturated power @ 800 MHz Power added efficiency @ 800 MHz Saturated power @ 1100 MHz Power added efficiency @ 1100 MHz Unless otherwise stated VREF = VCC. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 3 DATA SHEET • SKY65111-348LF Typical Performance Data VAPC1 Sweep 25 °C VAPC1,2 Sweep 25 °C VAPC2 Sweep -40 °C VAPC1 Sweep 85 °C 35 25 15 VAPC1,2 Sweep 85 °C VAPC2 Sweep 25 °C VAPC1 Sweep -40 °C VAPC1,2 Sweep -40 °C VAPC2 Sweep 85 °C 43 42 41 40 800 MHz 915 MHz 1100 MHz Gain (dB) 39 38 37 36 35 34 33 15 17 19 21 23 25 27 29 31 33 POUT (dBm) 5 -5 -15 -25 -35 0 0.5 1.0 1.5 2.0 2.5 3.0 POUT (dBm) Gain vs. POUT and Frequency VCC = 3.5, T = 25 °C, VAPC1,2 = 2.7 V VAPC (V) POUT vs. VAPC 915 MHz, PIN = -5 dBm VAPC1 varied from 0 V–2.6 V, VAPC2 held at 2.6 V. VAPC2 varied from 0 V–2.6 V, VAPC1 held at 2.6 V. VAPC1 and VAPC2 varied from 0 V–2.6 V together. 43 42 41 40 800 MHz 915 MHz 1100 MHz 43 42 41 40 800 MHz 915 MHz 1100 MHz Gain (dB) Gain (dB) 39 38 37 36 35 34 33 15 17 19 21 23 25 27 29 31 33 39 38 37 36 35 34 33 15 17 19 21 23 25 27 29 31 33 POUT (dBm) POUT (dBm) Gain vs. POUT and Frequency VCC = 3.5, T = 25 °C, VAPC1,2 = 2.8 V Gain vs. POUT and Frequency VCC = 3.5, T = 25 °C, VAPC1,2 = 2.6 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 4 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF 43 42 41 25 °C -20 °C 85 °C 50 °C -40 °C 0 °C 43 42 41 VCC = 5 V VCC = 3.5 V VCC = 2.5 V Gain (dB) 39 38 37 36 35 34 33 15 17 19 21 23 25 27 29 31 33 Gain (dB) 40 40 39 38 37 36 35 15 17 19 21 23 25 27 29 31 33 35 37 POUT (dBm) POUT (dBm) Gain vs. POUT, VCC = 3.5, VAPC1, 2 = 2.7 V, 915 MHz VAPC1,2 = 2.7 V VAPC1,2 = 2.6 V VAPC1,2 = 2.8 V Gain vs. POUT, VAPC1, 2 = 2.7 V, 915 MHz @ 25 °C -15 -20 P2FO (dBm) -25 -30 -40 -45 15 17 19 21 23 25 27 29 31 33 35 POUT (dBm) 2F0 vs. POUT, 915 MHz Fundamental, VCC = 3.5 V 25 °C PAE (%) -35 55 50 45 40 35 30 25 20 15 10 5 0 VCC = 3.5 V, VAPC1,2 = 2.7 V VCC = 3.5 V, VAPC1,2 = 2.6 V VCC = 3.5 V, VAPC1,2 = 2.8 V VCC = 4 V, VAPC1,2 = 2.6 V VCC = 4 V, VAPC1,2 = 2.7 V VCC = 4 V, VAPC1,2 = 2.8 V 10 12 14 16 18 20 22 24 26 28 30 32 34 36 POUT (dBm) % PAE vs. VAPC1, 2, and VCC 915 MHz @ 25 °C Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 5 DATA SHEET • SKY65111-348LF 65 60 55 50 45 40 35 30 25 20 15 10 5 0 VCC = 3.5 V, VAPC1,2 = 2.7 V VCC = 2.5 V, VAPC1,2 = 2.7 V VCC = 4 V, VAPC1,2 = 2.7 V VCC = 5 V, VAPC1,2 = 2.7 V 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 VCC = 3.5 V, VAPC = 2.7 V VCC = 3.5 V, VAPC = 2.8 V VCC = 4 V, VAPC = 2.7 V VCC = 3.5 V, VAPC = 2.6 V VCC = 4 V, VAPC = 2.6 V VCC = 4 V, VAPC = 2.8 V PAE (%) ICC (A) 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 12 14 16 18 20 22 24 26 28 30 32 34 36 POUT (dBm) POUT (dBm) % PAE vs. POUT and VCC, VAPC1,2 = 2.7, 915 MHz @ 25 °C VCC = 3.5 V, VAPC = 2.7 V VCC = 4 V, VAPC = 2.7 V VCC = 2.5V, VAPC = 2.7 V VCC = 5 V, VAPC = 2.7 V ICC vs. POUT, VCC and VAPC1,2 915 MHz, 25 °C 1.8 1.6 1.4 1.2 500 450 400 350 300 250 200 150 100 50 0 2.60 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C ICC (A) 1.0 0.8 0.6 0.4 0.2 0 14 16 18 20 22 24 26 28 30 32 34 36 38 ICQ (mA) 2.65 2.70 2.75 2.80 POUT (dBm) VAPC1,2 (V) ICC vs. POUT and VCC, VAPC1,2 = 2.7 V, 915 MHz @ 25 °C ICQ vs VAPC1, 2, VCC = 3.5 V RF Off @ 25 °C Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 6 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF 41 40 915 MHz 1000 MHz 800 MHz 1100 MHz 50 40 30 20 VCC = 3.5 V VCC = 2.5 V VCC = 5 V OIP3 (dBm) 39 38 37 36 35 2.60 2.65 2.70 2.75 2.80 2.85 2.90 2.95 3.00 Gain (dB) 10 0 -10 -20 -30 -40 -50 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Frequency (GHz) VAPC (V) OIP3 vs. VAPC1,2, Tone Spacing 1 MHz VCC = 3.5 V POUT = 20 dBm @ 25 °C 25 °C 0 °C 50 40 20 30 -40 °C 50 °C -20 °C 85 °C 0 -5 Gain vs. Frequency, VAPC1, 2 = 2.7 V PIN = -30 dBm, 25 °C 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C Input Return Loss (dB) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 -10 -15 -20 -25 -30 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Gain (dB) 10 0 -10 -20 -30 -40 -50 Frequency (GHz) Frequency (GHz) Gain vs. Frequency, VCC = 3.5 V, PIN = -30 dBm, VAPC1,2 = 2.7 V Input Return Loss vs. Frequenc VCC = 3.5 V, PIN = -30 dBm, VAPC1,2 = 2.7 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 7 DATA SHEET • SKY65111-348LF 0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C Output Return Loss (dB) Reverse Isolation (dB) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Frequency (GHz) Frequency (GHz) Output Return Loss vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C Reverse Isolation vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 0.80 0 -5 Input Return Loss (dB) -10 -15 -20 -25 -30 0.80 Gain (dB) 0.84 0.88 0.92 0.96 1.00 1.04 1.08 1.10 0.84 0.88 0.92 0.96 1.00 1.04 1.08 1.10 Frequency (GHz) Frequency (GHz) Gain vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V Input Return Loss vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 8 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF 0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50 0.80 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 0.80 25 °C 0 °C -40 °C 50 °C -20 °C 85 °C Output Return Loss (dB) 0.84 0.88 0.92 0.96 1.00 1.04 1.08 1.10 Reverse Isolation (dB) 0.84 0.88 0.92 0.96 1.00 1.04 1.08 1.10 Frequency (GHz) Frequency (GHz) Output Return Loss vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V VCC = 3.5 V @ 855 KHz VCC = 2.5 V @ 855 KHz VCC = 4 V @ 1.98 MHz VCC = 5 V @ 855 KHz -40 -45 VCC = 4 V @ 855 KHz VCC = 3.5 V @ 1.98 MHz VCC = 2.5 V @ 1.98 MHz VCC = 5 V @ 1.98 MHz Reverse Isolation vs. Frequency, VCC = 3.5 V PIN = -30 dBm, VAPC1,2 = 2.7 V VCC = 3.5 V @ 855 KHz VCC = 2.5 V @ 855 KHz VCC = 4 V @ 1.98 MHz VCC = 5 V @ 855 KHz -40 -45 VCC = 4 V @ 855 KHz VCC = 3.5 V @ 1.98 MHz VCC = 2.5 V @ 1.98 MHz VCC = 5 V @ 1.98 MHz ACPR (dBc) -55 -60 -65 -70 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ACPR (dBc) POUT (dBm) -50 -50 -55 -60 -65 -70 15 16 17 18 19 20 21 22 23 24 25 26 27 28 POUT (dBm) ACPR vs, POUT and Frequency IS-95, VAPC1,2 = 2.7 V, 881 MHz @ 25 °C ACPR vs, POUT and Frequency IS-95, VAPC1,2 = 2.7 V, 836 MHz @ 25 °C Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 9 DATA SHEET • SKY65111-348LF ACPR, IS-95 REV, VCC 3.5 V, VAPC1, 2 = 2.7 V 881 MHz @ 25 °C ACPR, IS-95 FWD, VCC 3.5 V, VAPC1, 2 = 2.7 V 836 MHz @ 25 °C Response Time, PIN = -15 dBm, 915 MHz, VCC = 3.5 V, VAPC1, 2 = 2.7 V @ 25 °C Response Time, Rise Time, 50% Ctrl, 90% RF VAPC1, 2 = 2.7 V/0 V @ 25 °C Response Time, Fall Time 90% RF, 50% Ctrl VAPC1, 2 = 2.7 V/0 V @ 25 °C Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 10 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF Bill of Material for Evaluation Board Designator C1 C2 C3 C4 C5 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 L1 L2 R1 R2 Value 100 pF 2.2 pF 4.7 pF 100 pF 1000 pF DNP 100 pF 1000 pF 10 µF 100 pF 1000 pF 10 nF 10 µF 12 pF 5.6 pF 10 µF DNP DNP DNP DNP 1000 pF 100 pF 100 pF 18 pF 1.8 nH 1 nH 0W 0W 0402 0402 0402 0402 0402 0402 0402 0402 Murata Murata Murata Murata Johanson Johanson Panasonic Panasonic GRM155R71H102KA01 GRM1555C1H101JD83E GRM1555C1H101JD83E GRM1555C180JZ35E L-07C1N8ST L-07C1N0ST ERJ2BJ00X ERJ2BJ00X 1 1 0402 0402 0402 0402 0402 0402 1206 0402 0402 1206 Murata Murata AVX Murata Murata Murata AVX Murata Murata AVX GRM1555C1H101JD83E GRM155R71H102KA01 TAJA106M006R GRM1555C1H101JD83E GRM155R71H102KA01 GRM155R71E103KA01 TAJA106M006R GJM1555C1H120JB01E GJM1555C1H5R6CB01E TAJA106M006R 2 2 2 2 1 1 1 1 Size 0402 0402 0402 0402 0402 Manufacturer Murata Murata Murata Murata Murata Part Number GRM1555C1H101JD83E GRM1555C1H2R2JZ35E GRM1555C1H4R7JZ35E GRM1555C1H101JD83E GRM155R71H102KA01 1 2 Notes 1. Panasonic and Murata are Skyworks preferred vendors. However, any suitable equivalent part is acceptable for this component. 2. "DNP" = Do not place. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 11 DATA SHEET • SKY65111-348LF Application Circuit VCC2 C10 C9 C8 C7 C11 C12 C13 C14 VCC3 16 15 14 13 12 11 L1 RF In C1 C25 C3 1 2 SKY65111-348 3 4 5 6 7 8 10 9 C2 C15 C16 C24 RF Out L2 VCC1 C17 C5 C4 C18 C19 C23 C22 VREF R1 R2 VAPC1 C20 C21 VAPC2 Component Placement Diagram Transmission line width: 0.027 inches. Gerber files available upon request. Incorrect soldering of the device paddle to grounding pad may lead to parasitic oscillations, reduced performance and increased device temperature rise. Uniform coverage over the entire bottom ground paddle must be maintained to avoid these conditions. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 12 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF Application Circuit Notes Ground, (Pins 1, 3, 8, 14). Attach all ground pins to the RF ground plane with the largest diameter and lowest inductance via that the layout will allow. Multiple small vias are also acceptable and will work well under the device if solder migration is an issue. It is extremely important that the device paddle be sufficiently grounded for both thermal and stability reasons. Please refer to the enclosed Package Footprint. RF input (Pin 2). A lumped element matching structure for good in-band return loss has been realized on the RF input, Pin 2. This structure is comprised of a DC blocking capacitor (C1), low pass LC filter (L1, C1) and at the device input, a series capacitor (C25). This combination of devices will yield a return loss better than 11 dB over the entire 800–1100 MHz band of interest. The placement of C1 is not critical; it can be moved as close to L1, C2 and C25 as desired. C25 should be placed as close to the device pin as possible to replicate performance as measured on the applications board. VCC1 (Pin 4). VCC1 is the collector bias for the first amplifier stage in the SKY65111. Multiple bypass capacitors, C3-C5, C17 and a series inductor, L2, have been utilized to ensure stability both in and out of the useable bandwidth of the device. The length of transmission line between L2 and Pin 4 is not critical; L2 can be placed as close to the pin as possible if desired. However, placement of L2 farther away from Pin 4 than shown on the Applications Circuit is not recommended. C3 should also be placed in the approximate location shown on the Applications Circuit, but placement is not critical. VAPC1 (Pin 5). VAPC1 is the bias control voltage input for amplifier stages 1 and 2. Nominal operating range is between 2.6 VDC and 2.8 VDC, with 3 VDC producing the minimum attenuation point. VAPC1 may also be set to 0 VDC, to force stages 1 and 2 into standby mode. VAPC2 (Pin 6). VAPC2 is the bias control voltage for amplifier stage 3. Nominal operating range is between 2.6 VDC and 2.8 VDC, with 3 VDC producing the minimum attenuation point. A 100 pF capacitor (C19) may be used for bypassing at high frequencies. The value of this capacitor may also be made large, greater than 1000 pF, if longer response time is acceptable. VAPC2 may also be set to 0 VDC, to place amplifier stage 3 into standby status. VREF (Pin 7). VREF is the bias reference voltage for amplifier stages 2 and 3. VREF should be operated over the same voltage range as VCC, with a nominal voltage of 3.5 VDC. Bypassing of VREF is accomplished with C22 and C23 which should be placed as close to the device pin as possible. RFOUT, VCC3 (Pins 9-12). RFOUT and VCC3 are the biasing input of the stage 3 collectors. Bias is applied to the RF output through a length of transmission line that is approximately 827 mils (21 mm) long. Capacitors C11-C14 provide proper RF bypassing and should be placed as shown in the Applications Circuit. Output matching for optimal power gain is accomplished with capacitors C15 and C16. Spacing between these capacitors with respect to the RF output and each other is critical and is shown on the Component Placement Diagram. Special care must be taken when placing these devices; their locations should not deviate significantly from the locations as shown. If these capacitors are not located properly, large decreases in output power and efficiency will occur. Pin 13. Pin 13 has no connection and should be left open circuit. VCC2 (Pins 15-16). VCC2 is the collector bias input for the second amplifier stage in the SKY65111. Multiple bypass capacitors, C8-C10 have been utilized to ensure stability both in and out of the useable bandwidth of the device. Capacitor C7 is not populated with the normal tuning configuration described above. NOTE: In most applications VAPC1 and VAPC2 pins are directly tied together and biased from the same control voltage. VAPC1 and VAPC2 may also be split if independent control is desired. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 13 DATA SHEET • SKY65111-348LF Package Footprint Evaluation Board Stack-Up Via Plating Thru Both Boards See Note 3 0.014 Ref. Circuit Board See Note 1A 0.062 ± 0.002 Ref. Copper Side of Backing Detail A Circuit Board Backing See Note 1B Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 14 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E DATA SHEET • SKY65111-348LF Application Board Bias Procedure Step 1. Connect DC ground. Step 2. Connect all VCC and VREF lines to 3.5 V supply, labeled 2. Step 3. With the RF off, apply 2.7 VDC to VAPC1, 2 control pins. Verify the ICQ current is approximately 250 mA, labeled 3. Step 4. Apply RF signal data -30 dBm level and observe that the output level is approximately 10 dBm or the gain of the device is approximately 40 dB. 1 GND 2 NOTE: It is important that the VCC1, VCC2, VCC3, and VREF voltage source be adjusted such that 3.5 V is measured at the board. The high collector currents will drop the collector voltage significantly if long leads are used. Adjust the bias voltage to compensate. RF In RF Out Recommended Solder Reflow Profiles Refer to the “Recommended Solder Reflow Profile” Application Note. 1 GND 3 2 1 GND Tape and Reel Information Refer to the “Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation” Application Note. Branding Specifications Pin 1 Indicator Pin 16 Pin 1 S111 XXXX YWW Top View Skyworks P/N Lot # Date Code Y = Calendar Year WW = Week Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 200428 Rev. E • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • February 12, 2007 15 DATA SHEET • SKY65111-348LF Copyright © 2002, 2003, 2004, 2005, 2006, 2007, Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 16 February 12, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200428 Rev. E
SKY65111-348LF 价格&库存

很抱歉,暂时无法提供与“SKY65111-348LF”相匹配的价格&库存,您可以联系我们找货

免费人工找货