Dynamic Speaker Electroacoustic Characteristics
Sound Pressure Level
SP DYNAMIC
SPEAKER UNIT
Acoustic Product Specification
92±3dB SPL @ 0.6, 0.8, 1.0, 1.2, 1.5 and 2.0KHz in average (0dB SPL=20μPa)
Measuring Condition: 0.1W (Sine wave) 10cm measured with baffler
shown in Fig.1
AC Impedance
8±15%Ω (@ 2 KHz 1V) without baffler
Frequency Response Curve
Product Number: SP-4005
SP-1605-3
As shown in Figure 2
Response Frequency
550 ± 20%Hz @ 1V. (Without Baffler)
Input Power (Nominal and Maximum)
Rated Noise Power: 2.0W
Short Term Max Power: 2.5W must be normal at a white noise
(1W, F0 ~ 20KHz) for one minute
Operation Test
Release | Revision: A/2016
Must be free audible noise (buzzes and rattles)
300 ~ 8KHz frequency range, input level up to 4.0Vrms
Distortion
CONTENTS
This document contains the
technical specifications for the
dynamic speaker unit.
Page 1
Speaker Electroacoustic
Characteristics
General Specifications
Page 2
Reliability Tests
Page 3
Measuring Method (Speaker
Mode)
Standard Test Condition of
Speakers
Page 4
Frequency Response Curve
Less than 10% @1KHz, 5cm, 0.1W frequency range, input level up to 0.1W
General Specifications
Operating Temperature Range
-20℃~+60℃
Standard Test Conditions
Temperature 17℃~25℃
Relative Humidity 45%~80%(RH)
Dimension
Ø40 x 5.5mm
IP Level
No rating
Page 5
Dimensions
Page 6
Packing
1
www.soberton.com
Reliability Tests
The sound pressure as specified will neither deviate more than ±3dB from the initial
value, nor have any significant damage after any of following testing.
SP DYNAMIC
SPEAKER UNIT
Acoustic Product Specification
High Temperature Test
High Temperature +65±2℃
Duration 96 hours
Low Temperature Test
Product Number: SP-4005
SP-1605-3
Low Temperature -20±2℃
Duration 96 hours
Heat Shock Test
High Temperature +65±2℃
Low Temperature -20±2℃
Changeover Time
很抱歉,暂时无法提供与“SP-4005”相匹配的价格&库存,您可以联系我们找货
免费人工找货