Features • Diplexer Single Mode Single Fiber 1x9 SC Receptacle Connector • Wavelength Tx 1310 nm/Rx 1490 nm • IEEE 802.3 Compliant • Single +3.3V power Supply • PECL/LVPECL Differential Inputs and Output [B-13/14-1250-T3-SSC] • TTL/LVTTL Signal Detection Output Optional [B-13/14-1250C-T3-SSC] • Wave Solderable and Aqueous Washable • LED Multisourced 1x9 Transceiver Interchangeable • Class 1 Laser Int. Safety Standard IEC 825 Compliant • Uncooled Laser diode with MQW structure • Complies with Telcordia (Bellcore) GR-468-CORE • RoHS compliance available
Absolute Maximum Rating
Parameter
Power Supply Voltage Input Voltage Output Current Soldering Temperature Storage Temperature
Symbol
Vcc
-
Min.
0 0 -40
Max.
3.6 Vcc 30 260 85
Unit
V V mA ºC ºC
Note
Iout
-
10 seconds on leads only
Tstg
Recommended Operating Condition
Parameter
Power Supply Voltage Operating Temperature (Case) Operating Temperature (Case) Data Rate
Symbol
Vcc Topr Topr -
Min.
3.1 0 -40 -
Typ.
3.3 1250
Max.
3.5 70 85 -
Unit
V ºC ºC Mbps
Transmitter Specifications (Optical)
Parameter
Optical Transmit Power Output center Wavelength Output Spectrum Width Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Optical Isolation Relative Intensity Noise Total Jitter
Symbol
Po λ ∆λ ER Tr
Tf -
Min
-10 1260 9 30 -
Typical
1310 -
Max
-3 1360 3 0.26 0.26 -116 0.27
Unit
dBm nm nm dB ns ns dB dB/Hz ns 20% to 80% Values 20% to 80% Values RMS (σ)
Notes
Output power is coupled into a 9/125 µm single mode fiber
Compliant with IEEE 802.3
Tx:1310 nm/ Rx:1490 nm Measured with 27-1 PRBS
RIN TJ
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Transmitter Specifications (Electrical)
Parameter
Power Supply Current Data Input Current-Low Data Input Current-High Differential Input Voltage Data Input Voltage-Low Data Input Voltage-High
Symbol
ICC IIL IIH VIH-VIL VIL-VCC VIH-VCC
Min
-350 300 -2.0 -1.1
Typical
-
Max
160 350 -1.58 -0.74
Unit
mA µA µA mV V V
Notes
Maximum current is specified at Vcc= Maximum @ maximum temperature
These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs
Receiver Specifications (Optical)
Parameter
Sensitivity Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Cross Talk Wavelength of Operation
Symbol
Pin Pa Pd -
Min
0 -38 1.0 1470
Typical
-
Max
-22 -22 -33 1600
Unit
dBm dBm dBm dBm dB dB nm
Notes
Measured with 27-1 PRBS, BER = 10-12
Measured on transition: low to high(Note1) Measured on transition: high to low(Note1)
Note 1: The SD level should be deasserted when fiber disconnected
Receiver Specifications (Electrical)
Parameter
Power Supply Current Data output Voltage-Low Data output Voltage-High Signal Detect output Voltge-Low Signal Detect Output Voltge-High Signal Detect output Voltge-Low Signal Detect Output Voltge-High
Symbol
ICC VOL -Vcc VOH- Vcc VSDL-Vcc VSDH- Vcc V SDL V SDH
Min
-2.0 -1.1 -2.0 -1.1 -20
Typical
-
Max
100 -1.58 -0.74 -1.58 -0.74 0.5 -
Unit
mA V V V V V V
Note
The current excludes the output load current These outputs are compatible with 10K, 10KH and 100KECL and PECL outputs B-13/14-1250-T3-SSC B-13/14-1250C-T3-SSC
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Connection Diagram
1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND)
NC
Top View
NC
Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground
PIN 1 2 3 4 5 6 7 8 Warnings 9
Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND
Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal DC power for the receiver section DC power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Recommended Circuit Schematic (PECL SD) B-13/14-1250-T3-SSC
Tx Vcc
C5
Rx Vcc
9
R1 R3
8
7
65
43
2
1
R9
R5
R7
C6
TD + TD -
RD + RD -
Tx Vcc Rx Vcc
R2 R4
SD
R10
No internal connection
Transceiver Top view
No internal connection
R6
R8
L1
Notes +3.3V: R1=R3=R5=R7=R9=130 R2=R4=R6=R8=R10=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H
Vcc
C3
L2
C4
C1
Rx Vcc
C2
Tx Vcc
Recommended Circuit Schematic (TTL SD) B-13/14-1250C-T3-SSC
Tx Vcc
C5
Rx Vcc
98
R1 R3
7
65
432
1
R5
R7
C6
TD + TD -
RD + RD -
Tx Vcc Rx Vcc
R2 R4
SD
R6 R8
No internal connection
Transceiver Top view
No internal connection
L1
Notes +3.3V: R1=R3=R5=R7=130 R2=R4=R6=R8=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H
Vcc
C3
L2
C4
C1
Rx Vcc
C2
Tx Vcc
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance.
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Package Diagram B-13/14-1250(C)-T3-SSC
Units in mm
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Ordering Information
Available Options: B-13/14-1250-T3-SSC-G5 B-13/14-1250C-T3-SSC-G5 B-13/14-1250-T3-SSCA-G5 B-13/14-1250C-T3-SSCA-G5
Part numbering Definition: B - 13/14 - 1250(C) - T - S SC Tx Power Temperature
• Wavelength Tx Wavelength=1310nm Rx Wavelength=1490nm • Communication protocol (1250 Gbps) 1250= PECL SD Output 1250C= TTL SD Output • T = +5 V Transceiver T3 = +3.3V Transceiver • Single mode fiber • Connector options • Tx Power Blank = -10 to -3 dBm
-RoHS
• Temperature range Blank = industrial temperature(0 to 70 ºC) A = industrial temperature(-40 to 85 ºC)
• RoHS Compliance options G5 = RoHS 5/6-compliant product (lead exemption)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS1828-May1308 Rev A.0
1.25 Gbps Bi-directional Receptacle Single Fiber Transceiver
B-13/14-1250(C)-T3-SSC
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notice
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7