0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B-15-155C-T-SSC3GR

B-15-155C-T-SSC3GR

  • 厂商:

    SOURCE

  • 封装:

  • 描述:

    B-15-155C-T-SSC3GR - 155 Mbps Bi-directional Receptacle Single Fiber Transceiver - Source Photonics,...

  • 数据手册
  • 价格&库存
B-15-155C-T-SSC3GR 数据手册
155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Features • Diplexer Single Mode Single Fiber 1x9 SC/FC/ST Receptacle Connector • Wavelength Tx 1310 nm/Rx 1530 nm • SONET OC-3 SDH STM-1 Compliant • Single +5V/+3.3V Power Supply • PECL/LVPECL Differential Inputs and Output [B-13/15-155-T(3)-Sxx3(4)] • TTL/LVTTL Differential Inputs and Output [B-13/15-155C-T(3)-Sxx3(4)] • Wave Solderable and Aqueous Washable • LED Multisourced 1x9 Transceiver Interchangeable • Class 1 Laser Int. Safety Standard IEC 825 Compliant • Uncooled Laser diode with MQW structure • Complies with Telcordia (Bellcore) GR-468-CORE • RoHS compliance available Absolute Maximum Rating Parameter Power Supply Voltage Power Supply Voltage Input Voltage Output Current Soldering Temperature Storage Temperature Symbol Vcc Vcc - Min. 0 0 0 -40 Max. 6 3.6 Vcc 30 260 85 Unit V V V mA ºC ºC Note B-13/15-155(C)-T-Sxx3(4) B-13/15-155(C)-T3-Sxx3(4) Iout - 10 seconds on leads only Tstg Recommended Operating Condition Parameter Power Supply Voltage Power Supply Voltage Operating Temperature (Case) Operating Temperature (Case) Data Rate Transmitter Specifications Symbol Vcc Vcc Topr Topr - Min. 4.75 3.1 0 -40 - Typ. 5 3.3 155 Max. 5.25 3.5 70 85 - Unit V V ºC ºC Mbps Parameter Optical Optical Transmit Power Optical Transmit Power Output center Wavelength Output Spectrum Width Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Optical Isolation Relative Intensity Noise Total Jitter Symbol Po Po λ ∆λ ER Tr Tf - Min -14 -8 1260 8.2 30 - Typical 1310 - Max -8 -3 1360 3 2 2 -116 1.2 Unit dBm dBm nm nm dB ns ns dB dB/Hz ns RMS (σ) Notes Output power is coupled into a 9/125 µm single mode fiber.B-13/15-155(C)-T(3)-Sxx3 Output power is coupled into a 9/125 µm single mode fiber.B-13/15-155(C)-T(3)-Sxx4 Compliant with ITU-T recommendation G.957/STM-1 10% to 90% Values 10% to 90% Values Tx:1530 nm/ Rx:1310 nm Measured with 223-1 PRBS with 72 ones and 72 zeros. RIN TJ LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Transmitter Specifications Parameter Electrical Power Supply Current Data Input Current-Low Data Input Current-High Differential Input Voltage Data Input Voltage-Low Data Input Voltage-High Symbol ICC IIL IIH VIH-VIL VIL-VCC VIH-VCC Min -350 300 -2.0 -1.1 Typical - Max 140 350 -1.58 -0.74 Unit mA µA µA mV V V Notes Maximum current is specified at Vcc= Maximum @ maximum temperature These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Receiver Specifications Parameter Optical Sensitivity Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Cross Talk Wavelength of Operation Symbol Pin Pa Pd Min -3 -45 1.0 Typical - Max -33 -33 4.0 -33 1600 Unit dBm dBm dBm dBm dB dB nm Notes Measured with 223-1 PRBS, BER = 10-10 Measured on transition: low to high (Note1) - 1480 Note 1: The SD level should be deasserted when fiber disconnected Receiver Specifications Parameter Electrical Power Supply Current Data output Voltage-Low Data output Voltage-High Signal Detect output Voltge-Low Signal Detect Output Voltge-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Symbol ICC VOL -Vcc VOH- Vcc VSDL-Vcc VSDH- Vcc VSDL VSDH Min -2.0 -1.1 -2.0 -1.1 2.0 Typical - Max 100 -1.58 -0.74 -1.58 -0.74 0.5 - Unit mA V V V V V V Note The current excludes the output load current These outputs are compatible with 10K, 10KH and 100KECL and PECL outputs B-13/15-155-T(3)-Sxx3(4) B-13/15-155C-T(3)-Sxx3(4) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground PIN 1 2 3 4 5 6 7 8 Warnings 9 Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal DC power for the receiver section DC power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Recommended Circuit Schematic (3.3V/5V) B-13/15-155-T(3)-Sxx3(4) Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 65 43 2 1 R9 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 SD R10 R6 No internal connection Transceiver Top view No internal connection R8 L1 Vcc Notes +3.3V: R1=R3=R5=R7=R9=130 R2=R4=R6=R8=R10=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Notes +5V: R1=R3=R5=R7=R9=82 R2=R4=R6=R8=R10=130 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H C3 C1 Rx Vcc L2 C4 C2 Tx Vcc Recommended Circuit Schematic (3.3V/5V) B-13/15-155C-T(3)-Sxx3(4) Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 65 43 2 1 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 SD R6 R8 No internal connection Transceiver Top view No internal connection L1 Vcc Notes +3.3V: R1=R3=R5=R7=130 R2=R4=R6=R8=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Notes +5V: R1=R3=R5=R7=82 R2=R4=R6=R8=130 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H C3 C1 Rx Vcc L2 C4 C2 Tx Vcc The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Package Diagram B-13/15-155(C)-T(3)-SSC3(4) Top View Front View Side View Rear View LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Package Diagram B-13/15-155(C)-T(3)-SFC3(4) Top View Front View Package Diagram B-13/15-155(C)-T(3)-SST3(4) Top View Front View LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Ordering Information B-13/15-155(C)-T-SSC3(4)(A) B-13/15-155(C)-T-SFC3(4)(A) B-13/15-155(C)-T-SST3(4)(A) B-13/15-155(C)-T3-SSC3(4)(A) B-13/15-155(C)-T3-SFC3(4)(A) B-13/15-155(C)-T3-SST3(4)(A) Available Options: B-13/15-155(C)-T-SSC3(4)(A)-G5 B-13/15-155(C)-T-SFC3(4)(A)-G5 B-13/15-155(C)-T-SST3(4)(A)-G5 B-13/15-155(C)-T3-SSC3(4)(A)-G5 B-13/15-155(C)-T3-SFC3(4)(A)-G5 B-13/15-155(C)-T3-SST3(4)(A)-G5 B-13/15-155(C)-T-SSC3(4)(A)-GR B-13/15-155(C)-T-SFC3(4)(A)-GR B-13/15-155(C)-T-SST3(4)(A)-GR B-13/15-155(C)-T3-SSC3(4)(A)-GR B-13/15-155(C)-T3-SFC3(4)(A)-GR B-13/15-155(C)-T3-SST3(4)(A)-GR Part Numbering Definitions: B - 13/15 - 155(C) - T(3) - S XX Tx Power Temperature and Package -RoHS • Wavelength Tx Wavelength=1310nm Rx Wavelength=1530nm • Communication protocol (155 Mbps) 155 = PECL Signal Detection Optupt 155C = TTL Signal Detection Optupt • T = +5 V Transceiver T3 = +3.3V Transceiver • Single mode fiber • Connector options SC/ST/FC • Tx Power 3 = -14 to -8 dBm 4 = -8 to -3 dBm • Temperature range and package Blank = commercial temperature(0 to 70 ºC) A = industrial temperature(-40 to 85 ºC) • RoHS Blank = RoHS non-compliant product G5 = RoHS 5/6-compliant product (lead exemption) GR = Full RoHS compliant product (no exemption) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS591-Apr2007 Rev A.2 155 Mbps Bi-directional Receptacle Single Fiber Transceiver B-13/15-155(C)-T(3)-Sxx3(4) Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notice IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 8 LUMNDS591-Apr2007 Rev A.2
B-15-155C-T-SSC3GR 价格&库存

很抱歉,暂时无法提供与“B-15-155C-T-SSC3GR”相匹配的价格&库存,您可以联系我们找货

免费人工找货