10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Features • Data Rate 1.062 to 1.25 Gb/s • Single 3.3V Supply • 10km Reach • 13dB Typical Link Budget • Commercial, Reduced and Industrial Temp. Operation • 1310nm FP Laser • Fibre Channel 100-SM-LC-L Compliant • Gigabit Ethernet IEEE 802.3ah Compliant • SFP MSA SFF-8074i Compliant • Telcordia GR-468 Compliant • Digital Diagnostic SFF-8472 Compliant • Color code Bail Latch : Blue • RoHS compliant
General Operation Parameter Supply Voltage Total Current Power Supply Rejectiona Operating Case Temperature (-CxA) Operating Case Temperature (-RxA) Operating Case Temperature (-TxA) Storage Temperature Data Rate GbE Data Rate FC a) 20Hz to 155MHz Symbol Vcc ICC PSR Topr Topr Topr Tstg DR DR Min. 3.135 100 -5 -20 -40 -40 Typ. 3.3 1250 1062.5 Max. 3.465 300 70 85 85 85 Unit V mA mVp-p ºC ºC ºC ºC Mbps Mbps
Transmitter Specifications (Optical) Parameter Optical Power Average Launch Power (Tx:Off) Extinction Ratio Eye Mask Total Jitter Optical Rise Timeb Optical Fall Time
b
Symbol Pop Poff ER TJ tr tf λ ∆λ RIN
Min -9 9 1270 -
Typical -5 1310 -
Max -3 -30 IEEE 802.3ah compliant 200 260 260 1355 -120
Unit dBm dBm dB ps ps ps nm dB/Hz
Mean Wavelength Spectral Width (RMS) Relative Intensity Noise b) 20%-80% values
IEEE 802.3ah 1000BASE-LX10 Compliant
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Transmitter Specifications (Electrical) Parameter Input Differential Impedence PECL Single Ended Data Input Swing TxFault_Fault TxFault_Normal TxDisable_Disable TxDisable_Enable Symbol Rin Vin, p-p Vfault Vnormal Vd Ven Min 80 250 2 Vee 2 Vee Typical 100 Max 120 1200 Vcc Vee + 0.5 Vcc Vee + 0.8 Unit Ω mV V V V V
Receiver Specifications (Optical) Parameter Receiver Power Lowc Receiver Power Highc Damage Threshold for Receiver Wavelengthd Maximum Reflectance of Receiver LOS Assert LOS De-Assert LOS Hysteresis PRBS of c) Measured at BER of 10 d) Operational over 1200-1625nm range Receiver Specifications (Electrical) Parameter PECL Single-Ended Data Output Swing Data Output Rise Time Data Output Fall Time Symbol Vout,p-p tr tf Min 185 Typical Max 800 260 260 Unit mV ps ps
-12,
Symbol Rsens,low Rsens,high Pin, damage λ RX_r 27-1, at eye center
Min -3 6 1270 -38 0.5
Typical -24 0 -
Max -22 1355 -12 -22 -
Unit dBm dBm dBm nm dB dBm dBm dB
Timing Timing and Electrical Parameter Tx Disable Negate Time Tx Disable Assert Time Time to Initialize, Including Reset of Tx Fault Tx Fault Assert Time Tx Disable to Reset LOS Assert Time LOS De-assert Time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) LOS Output Voltage-Fault LOS Output Voltage-Normal MOD_DEF (0:2)-High MOD_DEF (0:2)-Low Symbol t_on t_off t_init t_fault t_reset t_loss_on t_loss_off f_serial_clock Rx_LOSH RX_LOSL VLOS fault VLOS normal Vh VI Min 10 2 2 Vee 2 Vee Typical Max 1 10 300 100 100 100 100 Vcc 0.8 Vcc Vee + 0.5 Vcc Vee + 0.5 Unit ms µs ms µs µs µs µs KHz V V V V V V
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Diagnostics Parameter Temperature (-CDA) Temperature (-RDA) Temperature (-TDA) Voltage Bias Current Tx Power Rx Power Range -5 to 70 -20 to 85 -40 to 85 0 to Vcc 0 to 120 -9 to -3 -22 to -3 Accuracy ±3 ±3 ±3 0.1 5 ±3dB ±3dB Unit ºC ºC ºC V mA dBm dBm Calibration External External External External External External External Formula Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function VeeT TX_FAULT TX_DISABLE MOD_DEF2 MOD_DEF1 MOD_DEF0 NC LOS VeeR VeeR VeeR RXDRXD+ VeeR VCCR VCCT VeeT TXD+ TXDVeeT Notes TX GND Open Collector Internally Pulled High Serial Data Input Serial Clock Input Internally Grounded Not Connected Open Collector RX Ground RX Ground RX Ground RX Data Negative RX Data Positive RX GND RX Power TX Power TX GND TX Data Positive TX Data Negative TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
EEPROM Serial ID Name of Field Discription of Field Address 20 21 22 23 24 Vendor Name SFP Vendor name (ASCII) 25 26 27 28 29 30 37 Vendor OUI IEEE vendor OUI code for LuminentOIC Inc. 38 39 40 41 42 Vendor P/N Part number in ASCII, e.g. SP-GB-LX-CDA 43 44 45 46 47 48 Hex 4C 55 4D 49 4E 45 4E 54 4F 49 43 00 06 B5 53 50 47 42 4C 58 43 44 41 S P G B L X C D A ASCII L U M I N E N T O I C
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Outline Drawing
Units in mm(inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Suggested Transceiver interface
1�H
Vcc
10�F
0.1�F
1�H
.01�F
VCCT
Protocol IC
R1
10K� TX_DISABLE
LuminentOIC SFP
TX_DISABLE
TX_FAULT
SerDes
TX_FAULT TD + .01�F
Laser Driver
100� TD VEET .01�F
VCCR
10�F
0.1�F
Receiver Amplifier
RD +
100�
.01�F
RD .01�F
RX_LOS
RX_LOS
Vcc
R
1
VEER
EEPROM
R1
R1
R1
MOD_DEF 2 MOD_DEF 1 MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS833-Jul1008 Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Ordering Information
Available Options: SP-GB-LX-CDA SP-GB-LX-TDA SP-GB-LX-RDA
SP-GB-LX-CNA SP-GB-LX-TNA SP-GB-LX-RNA
Part numbering Definition:
SP - GB - LX - Temperature Diagnostic
• SP = Small Form Pluggable GB = 1.25Gbps LX = IEEE 802.3 LX Interface • Operating Temperature C = Commercial temperature (-5 to 70ºC) R = Reduced Industrial (-20 to 85ºC) T = Industrial temperature (-40 to 85ºC) • Diagnostic D = Digital Diagnostic (SFF-8472) N = No Diagnostic • Design Revision A = RoHS compliant Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Revision
Legal Notes:
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS833-Jul1008 Rev A.7