SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Features • Compliant with OC-3/STM-1 and OC-12/STM-4 Standards • Simplex LC connector • Single 3.3 V supply • 15 km reach • 13 dB Minimum Link Budget • 1550nm DFB Laser • Commercial temperature available (-Cxx) • Industrial temperature available (-Txx) • SFP MSA SFF-8074i compliant • Telcordia GR-468 compliant • Digital Diagnostic SFF-8472 compliant • Color coded bail latch: Yellow • RoHS compliant (lead free soldered)
General operating Parameter Supply Voltage Total Current Power Supply Noise Rejectiona Operating Temperature (-Cxx) Operating Temperature (-Txx) Storage Temperature Data Rate OC-3/STM-1 Data Rate OC-12/STM-4 Data Rate Fast Ethernet a) 20Hz to 155MHz Symbol Vcc Icc PSR Top Top Tst DR DR DR Min. 3.135 100 -5 -40 -40 Typical 3.3 155 622 125 Max. 3.465 300 70 85 85 Unit V mA mVp-p ºC ºC ºC Mbps Mbps Mbps
Transmitter Specifications Parameter Optical Power Average Launch Power Of Off Tx Extinction Ratio Eye Mask Optical Rise Timeb Optical Fall Timeb Mean Wavelength Spectral Width (RMS) Dispersion Penalty (at 15 Km) Relative Intensity Noise Optical Crosstalk Side Mode Suppression Ratio Reflectance Tolerance b) 20%-80% values RIN XT SMSR rp tr tf λ ∆λ 1480 30 -24 0.5 Symbol
POP POff
Min -15 8.2
Typical -11 -
Max -8 -45 500 500 1580 1 1 -120 -45 -
Unit dBm dBm dB ps ps nm nm dB dB/Hz dB dB dB
ER
IEEE 802.3 and SONET/SDH Compliant
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Transmitter Specifications (Electical) Parameter Input Differential Impedence PECL Single Ended Data Input Swing TxFault_Fault TxFault_Normal TxDisable_Disable TxDisable_Enable Symbol Rin Vin,p-p Vfault Vnormal Vd Ven Min 80 250 2 Vee 2 Vee Typical 100 Max 120 1200 Vcc Vee+0.5 Vcc Vee+0.8 Unit Ω mV V V V V
Receiver Specifications Parameter Receive Power Lowc Receive Power Highc Damage Threshold For Receiver Wavelength LOS Assert LOS De-assert LOS Hysteresis Receiver Reflectance c) at 10-12 BER, FE unbalanced pattern, and 10-10 Symbol Rsens,low Rsens,high Pin,damage λ Min -8 1260 -38 0.5 BER, 155.52 Mb/s & 622.08 Mb/s Typical -30 Max -28 0 1360 -28 -12 Unit dBm dBm dBm nm dBm dBm dB dB
Electrical Output Parameter PECL Single Ended Data Output Swing Data Output Rise Time Data Output Fall Time Symbol Vout, p-p tr tf Min 185 Typical Max 800 500 500 Unit mV ps ps
Timing and Electrical Parameter Tx Disable Negate Time Tx Disable Assert Time Time To Initialize, Including Reset Of Tx Fault Tx Fault Assert Time Tx Disable To Reset Los Assert Time Los De-assert Time Serial ID Clock Rate RX_LOS Voltage (High) RX_LOS Voltage (Low) LOS Output Voltage-Fault LOS Output Voltage-Normal MOD_DEF (0:2)-High MOD_DEF (0:2)-LOW VLOS fault VLOSnormal Vh Vl Symbol t_on t_off t_init t_fault t_reset t_loss_on t_loss_off f_serial_clock Min 10 2 2 Vee 2 Vee Typical Max 1 10 300 100 100 100 100 0.8 Vcc Vee+0.5 Vcc Vee+0.5 Unit ms µs ms µs µs µs µs KHz V V V V V V
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Diagnostics Parameter Temperature (-Cxx) Temperature (-Txx) Voltage Bias current TX Power RX Power Range -5 to 70 -40 to 85 0 to Vcc 0 to 120 -15 to -8 -28 to -8 Accuracy ±3 ±3 0.1 5 ±2dB ±2dB Unit Calibration Bit value ºC ºC V mA dBm dBm Internal Internal Internal External External External 1/256 C 1/256 C 100 µV 0.002mA 0.1 µw 0.1 µw Formula Tc(C)=Tad(16 bit signed twos complement)/256 Tc(C)=Tad(16 bit signed twos complement)/256 V(Volts)=Vad(16 bit unsigned integer)*0.1 I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer +TX_PWRoffset RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
EEPROM Serial ID Name of Field Description of Field Address 20 21 22 23 24 Vendor Name SFP Vendor name(ASCII) 25 26 27 28 29 30 37 Vendor OUI IEEE vendor OUI code for LuminentOIC Inc. 38 39 40 41 42 43 44 45 Vendor PN Part number in ASCII, e.g. SPL-53-DR-IR1-CDA 46 47 48 49 50 51 52 Hex 4C 55 4D 49 4E 45 4E 54 4F 49 43 00 06 B5 53 50 4C 35 33 44 52 49 52 31 43 44 41 S P L 5 3 D R I R 1 C D A ASCII L U M I N E N T O I C
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Function VeeT
TX_FAULT TX_DISABLE MOD_DEF2 MOD_DEF1 MOD_DEF0 NC LOS
Notes TX Ground Open Collector Internally Pulled High Serial Data Input Serial Clock Input Internally Grounded Not Connected Open Collector RX Ground RX Ground RX Ground RX Data Negative RX Data Positive RX Ground RX Power TX Power TX Ground TX Data Positive TX Data Negative TX Ground
VeeR VeeR VeeR
RXDRXD+
VeeR VccR VccT VeeT TXD+ TXDVeeT
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Outline drawing
Units in mm (inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Suggested Transceiver Interface
1�H
Vcc
10�F 0.1�F 1�H
.01�F VCCT
Protocol IC
R1
TX_DISABLE
10K� TX_DISABLE
LuminentOIC SFP
TX_FAULT
TX_FAULT
Laser Driver
.01�F
SerDes
TD +
100� TD VEET .01�F
VCCR
10�F 0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
Vcc
RX_LOS
R
1
.01�F
VEER
EEPROM
R1
R1
R1
MOD_DEF 2 MOD_DEF 1
R1=4.7K to 10K�
MOD_DEF 0
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS1689-Apr3007 Rev 0.1
SFP Bi-Directional Transceiver Preliminary
SPL-53-DR-IR1
Ordering Information Available Options: SPL-53-DR-IR1-CDA SPL-53-DR-IR1-CNA SPL-53-DR-IR1-TDA SPL-53-DR-IR1-TNA Part numbering Definition:
SPL - 53 - DR - IR1
• SPL = LC connector • 53 = Tx 1550nm/Rx 1310nm • DR = Dual Rate 155M/622M • IR1 = Reach 15 km • Operating Temperature C = Commercial temperature (-5 to 70ºC) T = Industrial temperature (-40 to 85ºC) • D = Digital Diagnostic (SFF-8472) N = No Diagnostic • Design Revision A = RoHS compliant (lead free soldered)
- Temperature Diagnostic
Revision
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS1689-Apr3007 Rev 0.1