SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Features • Compliant with IEEE 802.3ah, 1000BaseBX • Simplex LC Connector • Digital Diagnostic SFF-8472 Compliant • SFP MSA SFF-8074i Compliant • 13dB Minimum Power Budget • 20 km Minimum Reach • Single 3.3V Supply • 1550nm DFB Laser • Telcordia GR-468 Compliant • Color coded bail latch tube: Yellow • RoHS-5/6 compliance produit (lead exemption)
General Operation Parameter Supply Voltage Total Current Power Supply Noise Rejection Operating Case Temperature (-Cxx) Operating Case Temperature (-Txx) Storage Temperature Data Rate Topr Topr Tstg DR Symbol Vcc ICC Min. 3.153 100 -5 -40 -40 Typ. 3.3 1250 Max. 3.465 300 70 85 85 Unit V mA mVp-p ºC ºC ºC Mbps
Transmitter Specifications (Optical) Parameter Optical Power Optical Crosstalk Average Launch Power (Tx:Off) Extinction Ratio Eye Mask Optical Rise Time (20% to 80% values) Optical Fall Time (20% to 80% values) Mean Wavelength Spectral Width (RMS) Relative Intensity Noise Transmitter Reflectance Reflection Tolerance Symbol Pop XT Poff ER − tr tf λ σ RIN rp 1500 1550 Min -7 6 Typical -4 -45 Max 0 -40 -45 IEEE 802.3ah 260 260 1600 0.88 -120 -12 12 ps ps nm nm dB/Hz dB dB Unit dBm dB dBm dB
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Transmitter Specifications (Electrical) Parameter Input Differential Impedence PECL Single Ended data input swing TxFault_Fault TxFault_Normal TxDisable_Disable TxDisable_Enable Symbol Rin Vin, p-p Vfault Vnormal Vd Ven Min 80 250 2 Vee 2 Vee Typical 100 Max 120 1200 Vcc Vee + 0.5 Vcc Vee + 0.8 Unit Ω mV V V V V
Receiver Specifications (Optical) Parameter Receiver Power Lowb Receiver Power High Damage Threshold for Receiver Wavelength LOS Assert LOS De-assert LOS hysteresis Receiver Reflectance a) Measured at 10-12 BER, PRBS 27-1, 6dB ER Symbol Rsens,low Rsens,high Pin, damage λ Min -3 0 1260 -45 0.5 Typical -22 Max -20 1360 -20 -12 Unit dBm dBm dBm nm dBm dBm dB dB
Receiver Specifications (Electrical) Parameter PECL Single ended data output swing Data output rise time Data output fall time Symbol Vout,p-p tr tf Min 185 Typical Max 800 260 260 Unit mV ps ps
Timing and Electrical Parameter Tx Disable Negate time Tx Disable assert time Time to initialize, including reset of Tx fault Tx fault Assert time Tx Disable to reset LOS Assert time LOS De-assert time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) LOS output voltage-Fault LOS output voltage-Normal MOD_DEF (0:2)-High MOD_DEF (0:2)-Low Symbol t_on t_off t_init t_fault t_reset t_loss_on t_loss_off f_serial_clock Rx_LOSH RX_LOSL VLOS fault VLOS normal Vh VI Min 10 2 2 Vee 2 Vee Typical Max 1 10 300 100 100 100 100 0.8 Vcc Vee + 0.5 Vcc Vee + 0.5 Unit ms µs ms µs µs µs µs KHz V V V V V V
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Diagnostics Parameter Temperature (-TDA) Temperature(-CDA) Voltage Bias Current Tx Power Rx Power Range -40 to 85 -5 to 70 0 to Vcc 0 to 120 -7 to 0 -20 to -3 Accuracy ±3 ±3 0.1 5 ±3 ±3 Unit ºC ºC V mA dBm dBm Calibration Internal Internal Internal External External External Bit Value 1/256 C 1/256 C 100µV Formula Tc(C) = Tad(16 bit signed twos complement)/256 Tc(C) = Tad(16 bit signed twos complement)/256 V(Volts) = Vad(16 bit unsigned integer)*0.1 I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function VeeT TX_FAULT TX_DISABLE MOD_DEF2 MOD_DEF1 MOD_DEF0 NC LOS VeeR VeeR VeeR RXDRXD+ VeeR VCCR VCCT VeeT TXD+ TXDVeeT Notes TX GND Open Collector Internally Pulled High Serial Data Input Serial Clock Input Internally Grounded Not Connected Open Collector RX Ground RX Ground RX Ground RX Data Negative RX Data Positive RX GND RX Power TX Power TX GND TX Data Positive TX Data Negative TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
EEPROM Serial ID Name of Field Discription of Field Address 20 21 22 23 24 Vendor Name SFPVendor name (ASCII) 25 26 27 28 29 30 37 Vendor OUI IEEE vendor OUI code for Luminent Inc. 38 39 40 41 42 43 Vendor PN Part number in ASCII, e.g. SPL-53-GB-EBX 44 45 46 47 48 49 Hex 4C 55 4D 49 4E 45 4E 54 4F 49 43 00 06 B5 53 50 4C 35 33 47 42 45 42 58 S P L 5 3 G B E B X ASCII L U M I N E N T O I C
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Mechanicals
Units in mm (inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Suggested Transceiver Interface Diagnostics
Vcc
10�F 0.1�F
1�H 1�H
VCCT
.01�F
Protocol IC
R1
TX_DISABLE
10K� TX_DISABLE
LuminentOIC SFP
TX_FAULT
TX_FAULT
Laser Driver
.01�F
SerDes
TD +
100� TD VEET .01�F
VCCR
10�F 0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
Vcc
RX_LOS
R
1
.01�F
VEER
EEPROM
R1
R1
R1
MOD_DEF 2 MOD_DEF 1
R1=4.7K to 10K�
MOD_DEF 0
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS1510-Oct3106 Rev A.1
SFP Bi-Directional Transceiver
SPL-53-GB-EBX
Ordering Information Available Options: SPL-53-GB-EBX-CNA SPL-53-GB-EBX-TNA SPL-53-GB-EBX-CDA SPL-53-GB-EBX-TDA Part numbering Definition:
SPL - 53 - GB - EBX - Temperature
• SPL = LC connector • Wavelength 53 = Tx 1550nm/Rx 1310nm • Data Rate GB = Gigabit Ethernet • Standard EBX = 20 km reach • Operatating Temperature C= Commercial temperature (-5 to 70ºC) T= Industrial temperature (-40 to 85ºC) • D = Digital Diagnostic N = No Digital Diagnostic • Revision A=RoHS 5/6-compliant product (lead exemption) Warnings:
Diagnostic Revision
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS1510-Oct3106 Rev A.1