Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
FEATURES
• –55°C to +125°C operation • 16 to 40 VDC input • Up to 60 dB attenuation at 500 kHz. • Active transient suppression • Undervoltage lockout • Inhibit function • Compliant to MIL-STD-461C, CE03
MODEL
FM-704A 40 Watts
DESCRIPTION
Interpoint’s FM-704A™ EMI Filter and Transient Suppression Module combines EMI filtering and transient protection to handle the demanding requirements of military, aerospace and industrial applications. As an EMI filter the FM-704A filter reduces the reflected ripple current from DC/DC switching converters. As a protection module, it suppresses input transients on the power bus to protect the converter and other downstream components.
INTERNAL POWER DISSIPATION
To keep internal power dissipation to safe operating levels, the input current should never exceed 2.5 amps at 16 Vin or 1.0 amp at 40 Vin. When the FM-704A filter is used with PWM (Pulse Width Modulated) converters, Iline will vary as Power / Vline and 2.5 amps maximum at 16 Vin will reduce to approximately 1 amp maximum at 40 Vin. The maximum value allowed may be less than 1 amp as determined by line transients and the safe operating area of Figure 9. Figure 9 illustrates the maximum allowed internal dissipation for the FM-704A filter. To calculate watts dissipated, subtract 40 volts from the transient (VT) to determine the maximum voltage across the filter and multiply the result by the current (the filter’s output power, Pout divided by 40). W = (VT - 40) x Pout /40 For example, with 20 watts output and a transient of 400 volts: W = (400 - 40) x 20/40 = 180 The curve of Figure 9 shows that 180 W can be dissipated for up to 4 milliseconds.
MIL-STD NOISE MANAGEMENT
When used in conjunction with Interpoint converters, the FM-704A EMI filter reduces reflected input ripple current by a minimum of 60 dB at 500 kHz and 55 dB at 1 MHz (see Figures and Electrical Characteristics table). This attenuation gives the converter/filter combination performance exceeding MIL-STD-461C’s CE03 test. Although the FM-704A filter effectively attenuates the ripple generated by switching converters, it will not suppress RF applied to its input terminals.
TEMPERATURE OPERATION
FM-704A filters are rated to operate from -55°C to +125°C baseplate temperature. To meet MIL-STD-1275A and MIL-STD-704A requirements, derate output power linearly from 40 watts at 105°C to 25 watts at 125°C. See Figure 9.
FEATURES
The inhibit function allows the FM-704A filter to be used as a highside switch. When the inhibit terminal (pin 6) is left open or pulled high, the FM-704A filter is enabled. When the terminal is grounded, the filter shuts off output power. A soft start function helps reduce inrush current and start-up overshoot when the filter is initially powered or when it is released from the inhibit mode. An undervoltage lockout feature shuts off output power when input voltage falls below a specified level. Refer to Figure 8 for more information.
PROTECTION
To provide protection for itself and converters, the FM-704A filter blocks transients as required by the following standards: MIL-STD-704A Panavia SP-P-90001 MIL-STD-461B&C British Standard BS3G100 MIL-STD-1275 Civil Aircraft D0160B Refer to the Electrical Characteristics table on the following page for more information. Reverse polarity spikes of up to 100 V will not damage the filter, however the spikes will not be blocked by the filter.
LAYOUT REQUIREMENTS
The case of the filter must be connected to the case of the converter through a low impedance connection to minimize EMI.
Crane Aerospace & Electronics, Interpoint Corp. PO Box 97005 • Redmond WA 98073-9705 425.882.3100 • electronics@craneae.com www.craneae.com
Page 1 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
OPERATING CONDITIONS AND CHARACTERISTICS
Input Voltage Range • 16 to 40 VDC continuous for 40 W load Lead Soldering Temperature (10 sec per pin) • 300°C Storage Temperature Range (Case) • –65°C to +150°C Case Operating Temperature (Tc) • –55°C to +125°C full power Derating Output Power/Current • Linearly from 40 W at 105°C to 25 W at 125°C to meet MIL-STD-1275A (AT) and MIL-STD-704A Capacitance • 0.017 µF max, any pin to case Undervoltage lockout • 7 VDC min, 15 VDC max Isolation • 100 megohm minimum at 500 V • Any pin to case, except case pin Inhibit Pin Voltage (unit enabled) • 5.5 V max
INHIBIT TTL OPEN COLLECTOR
• Logic low (output disabled) Logic low voltage ≤0.8 V Logic low inhibit pin current 0.6 mA max • Referenced to input common • Logic high (output enabled) Open collector
MECHANICAL AND ENVIRONMENTAL
Size (maximum) 2.910 x 1.125 x 0.400 inches (73.91 x 28.58 x 10.16 mm) See case K1 for dimensions. Weight (maximum) 40 grams typical Screening Standard, ES, or 883 (Class H). See “QA Screening: /883 (Class H, QML)” for more information.
Positive Input 25 3300 pF Inhibit Input Common
Oscillator
390 H
3.6 H
3.6 H Positive Output 3300 pF 500V
0.068 F
6F
6F
Case 6600 pF 500V Output Common
3300 pF / 500V 15
FM-704A
The case ground connection between the filter and the converter should be as low an impedance as possible to minimize EMI. Direct contact of baseplate to chassis ground provides the lowest impedance.
FIGURE 1: SCHEMATIC – TYPICAL VALUES
www.craneae.com
Page 2 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
PIN OUT Pin 1 2 3 4 5 6 Designation Positive Input Positive Output Case Ground Output Common Input Common Inhibit PINS NOT IN USE
Dot on top of package indicates pin one
1 6
2
BOTTOM VIEW FM-704A
3
5
4
See case K1 for dimensions.
FIGURE 2: PIN OUT
www.craneae.com
Page 3 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
MODEL NUMBERING KEY
FM - 704A / Base Model MIL-STD-704A Reference Screening (Standard screening has no designator in this position.) 883
DSCC NUMBER
DSCC DRAWING (5915) 94028-01HXC FM-704A FILTER SIMILAR PART FM-704A/883
For exact specifications for a DSCC product, refer to the DSCC drawing. See “SMD/DSCC Lists” for more information.
Model Selection
FM Base model 704A MIL-STD-461 ref.
case option
Screening
Choose one from each of the following rows Case option Screening case K1 standard screening, leave blank /ES (ES screening), /883 (Class H, QML)
www.craneae.com
Page 4 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
Electrical Characteristics: 25°C Tc, nominal Vin, unless otherwise specified.
PARAMETER INPUT VOLTAGE
INPUT CURRENT
INPUT SURGE INPUT SPIKE DIFFERENTIAL MODE NOISE REJECTION DC RESISTANCE (RDC) OUTPUT VOLTAGE OUTPUT CURRENT INTERNAL POWER DISSIPATION
CONDITIONS NO LOAD 40 W LOAD UNDERVOLTAGE LOCKOUT 16 VIN 40 VIN NO LOAD INHIBITED 40 W, 100 V, 0.5 Ω ZS, 60 ms1 40 W, 400 V, 0.5 Ω ZS, 5 µs2 40 W, 600 V, 50 Ω ZS, 10 µs3 500 kHz 1 MHz Tc = 25°C STEADY STATE INHIBITED 16 VIN 40 VIN PEAK 105°C 125°C CONTINUOUS ( > 10 SEC.) 105°C 125°C
MIN 0 16 7 —
—
FM-704A TYP 28 28 — —
—
— — 42 — — 60 55 — — —
—
— — — — — — — — VOUT = VIN - IIN (RDC) — —
—
MAX 40 40 15 2.5 1.0 5 2 48 48 48 — — 0.45 1 2.5 1.0 1000 500 30 15
UNITS VDC
A mA VOUT V
OUT
dB Ω VDC A
— — — —
— — — —
W
Notes 1. Meets MIL-STD-1275A (AT) Surge and Figure 8 and 9 of MIL-STD-704A. For these standards derate output power linearly from 40 W at 105°C to 25 W at 125°C. 2. Meets Panavia SP-P-90001, British Standard BS3G100 and Civil Aircraft D0160 Standards. 3. Meets MIL-STD-461C 1.2 CS06 limits.
www.craneae.com
Page 5 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Transient Suppression Module
Typical Performance Curves: 25°C Tc , nominal Vin, unless otherwise specified.
90
90
20
CE03 Limit
70
70
0
EMISSION LEVEL (dmA)
EMISSION LEVEL (dmA)
50
50
GAIN (dB)
–20
–40
30
30
–60
10
10
-80 10 K
.015 0.1 1 10 50
.015 .1 1 10 50
100 K
1M
FREQUENCY (Hz)
FREQUENCY (MHz)
FREQUENCY (MHz)
MHF+ Converter Without Filter FIGURE 3
MHF+ Converter With FM-704A Filter FIGURE 4
Differential Mode Response FIGURE 5
IMPEDANCE (Z, OHMS)
10.00
Vin andVout
1 A / div.
1.00
5 V/ div.
0.10
Vin Vout
0 volts for Vout
0.01
5 ms / div. 15 watt load
FM–704A
1K
10 K
100 K
1M
FREQUENCY (Hz)
100 ms / div.
FM–704A
Inrush Current FIGURE 6
Typical Output Impedance (Z) With Input Shorted FIGURE 7
Undervoltage Lockout FIGURE 8
1000
WATTS
100
10 0.1
1
10
100
1000
TIME (ms)
Derate power linearly to 50% at 125°C. Operation below this curve ensures a maximum junction temperature rise of 40°C or less.
Maximum Allowed Internal Power Dissipation 105°C case temperature FIGURE 9
www.craneae.com Page 6 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
FM-704A EMI Input Filter and Trans. Suppression Module Cases
www.craneae.com
Page 7 of 8 Rev B - 20060125
Crane Aerospace & Electronics Power Solutions
Quality Assurance
883, CLASS H, QML SCREENING
TEST 125°C STANDARD non-QML 125°C /ES non-QML Class H /883 QML Pre-cap Inspection Method 2017, 2032 Temperature Cycle (10 times) Method 1010, Cond. C, -65°C to 150°C, ambient Method 1010, Cond. B, -55°C to 125°C, ambient Constant Acceleration Method 2001, 3000 g Method 2001, 500g Burn-In Method 1015, 160 hours at 125°C case, typical 96 hours at 125°C case, typical Final Electrical Test MIL-PRF-38534, Group A Subgroups 1 through 6: -55°C, +25°C, +125°C case Subgroups 1 and 4: +25°C case Hermeticity Test Fine Leak, Method 1014, Cond. A Gross Leak, Method 1014, Cond. C Gross Leak, Dip (1 x 10-3) Final Visual Inspection Method 2009
yes
yes
yes
no no
no yes
yes no
no no
no yes
yes no
no no
no yes
yes no
no yes
no yes
yes no
no no yes
yes yes no
yes yes no
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
FM704A EMI Input Filter. Rev B - 20060125. This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. SMFL Series is a trademark of Interpoint. Copyright © 1992 - 2006 Interpoint Corporation. All rights reserved. www.craneae.com
Page 8 of 8