0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SST36VF3203-70-4I-B3KE

SST36VF3203-70-4I-B3KE

  • 厂商:

    SST

  • 封装:

  • 描述:

    SST36VF3203-70-4I-B3KE - 32 Mbit (x8/x16) Concurrent SuperFlash - Silicon Storage Technology, Inc

  • 数据手册
  • 价格&库存
SST36VF3203-70-4I-B3KE 数据手册
32 Mbit (x8/x16) Concurrent SuperFlash SST36VF3203 / SST36VF3204 SST36VF3201C / 1602C32Mb (x8/x16) Concurrent SuperFlash Data Sheet FEATURES: • Organized as 2M x16 or 4M x8 • Dual Bank Architecture for Concurrent Read/Write Operation – 32 Mbit Bottom Sector Protection (in the smaller bank) - SST36VF3203: 8 Mbit + 24 Mbit – 32 Mbit Top Sector Protection (in the smaller bank) - SST36VF3204: 24 Mbit + 8 Mbit • Single 2.7-3.6V for Read and Write Operations • Superior Reliability – Endurance: 100,000 cycles (typical) – Greater than 100 years Data Retention • Low Power Consumption: – Active Current: 6 mA typical – Standby Current: 4 µA typical – Auto Low Power Mode: 4 µA typical • Hardware Sector Protection/WP# Input Pin – Protects 8 KWord in the smaller bank by driving WP# low and unprotects by driving WP# high • Hardware Reset Pin (RST#) – Resets the internal state machine to reading array data • Byte# Pin – Selects 8-bit or 16-bit mode • Sector-Erase Capability – Uniform 2 KWord sectors • Chip-Erase Capability • Block-Erase Capability – Uniform 32 KWord blocks • Erase-Suspend / Erase-Resume Capabilities • Security ID Feature – SST: 128 bits – User: 256 Bytes • Fast Read Access Time – 70 ns • Latched Address and Data • Fast Erase and Program (typical): – Sector-Erase Time: 18 ms – Block-Erase Time: 18 ms – Chip-Erase Time: 35 ms – Program Time: 7 µs • Automatic Write Timing – Internal VPP Generation • End-of-Write Detection – Toggle Bit – Data# Polling – Ready/Busy# pin • CMOS I/O Compatibility • Conforms to Common Flash Memory Interface (CFI) • JEDEC Standards – Flash EEPROM Pinouts and command sets • Packages Available – 48-ball TFBGA (6mm x 8mm) – 48-lead TSOP (12mm x 20mm) • All non-Pb (lead-free) devices are RoHS compliant PRODUCT DESCRIPTION The SST36VF320x are 2M x16 or 4M x8 CMOS Concurrent Read/Write Flash Memory manufactured with SST’s proprietary, high performance CMOS SuperFlash technology. The split-gate cell design and thick-oxide tunneling injector attain better reliability and manufacturability compared with alternate approaches. The devices write (Program or Erase) with a 2.7-3.6V power supply and conform to JEDEC standard pinouts for x8/x16 memories. Featuring high performance Word-Program, these devices provide a typical Program time of 7 µsec and use the Toggle Bit, Data# Polling, or RY/BY# to detect the completion of the Program or Erase operation. To protect against inadvertent write, the devices have on-chip hardware and Software Data Protection schemes. Designed, manufactured, and tested for a wide spectrum of applications, these devices are offered with a guaranteed endurance of 10,000 cycles. Data retention is rated at greater than 100 years. These devices are suited for applications that require convenient and economical updating of program, configuration, or data memory. For all system applications, the devices significantly improve performance and reliability, while lowering power consumption. Since for any given voltage range, the SuperFlash technology uses less current to program and has a shorter erase time, the total energy consumed during any Erase or Program operation is less than alternative flash technologies. These devices also improve flexibility while lowering the cost for program, data, and configuration storage applications. © 2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 1 The SST logo and SuperFlash are registered trademarks of Silicon Storage Technology, Inc. CSF is a trademark of Silicon Storage Technology, Inc. These specifications are subject to change without notice. 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet SuperFlash technology provides fixed Erase and Program times, independent of the number of Erase/Program cycles that have occurred. Therefore the system software or hardware does not have to be modified or de-rated as is necessary with alternative flash technologies, whose Erase and Program times increase with accumulated Erase/Program cycles. To meet high-density, surface-mount requirements, these devices are offered in 48-ball TFBGA and 48-lead TSOP packages. See Figures 1 and 2 for pin assignments. Read Operation The Read operation is controlled by CE# and OE#; both have to be low for the system to obtain data from the outputs. CE# is used for device selection. When CE# is high, the chip is deselected and only standby power is consumed. OE# is the output control and is used to gate data from the output pins. The data bus is in a high impedance state when either CE# or OE# is high. Refer to the Read cycle timing diagram for further details (Figure 3). Program Operation Device Operation Memory operation functions are initiated using standard microprocessor write sequences. A command is written by asserting WE# low while keeping CE# low. The address bus is latched on the falling edge of WE# or CE#, whichever occurs last. The data bus is latched on the rising edge of WE# or CE#, whichever occurs first. These devices are programmed on a word-by-word or byte-by-byte basis depending on the state of the BYTE# pin. Before programming, one must ensure that the sector which is being programmed is fully erased. The Program operation is accomplished in three steps: 1. Software Data Protection is initiated using the three-byte load sequence. 2. Address and data are loaded. During the Program operation, the addresses are latched on the falling edge of either CE# or WE#, whichever occurs last. The data is latched on the rising edge of either CE# or WE#, whichever occurs first. 3. The internal Program operation is initiated after the rising edge of the fourth WE# or CE#, whichever occurs first. The Program operation, once initiated, will be completed typically within 7 µs. See Figures 4 and 5 for WE# and CE# controlled Program operation timing diagrams and Figure 19 for flowcharts. During the Program operation, the only valid reads are Data# Polling and Toggle Bit. During the internal Program operation, the host is free to perform additional tasks. Any commands issued during an internal Program operation are ignored. Auto Low Power Mode These devices also have the Auto Lower Power mode which puts them in a near standby mode within 500 ns after data has been accessed with a valid Read operation. This reduces the IDD active Read current to 4 µA typically. While CE# is low, the devices exit Auto Low Power mode with any address transition or control signal transition used to initiate another Read cycle, with no access time penalty. Concurrent Read/Write Operation The dual bank architecture of these devices allows the Concurrent Read/Write operation whereby the user can read from one bank while programming or erasing in the other bank. For example, reading system code in one bank while updating data in the other bank. CONCURRENT READ/WRITE STATE Bank 1 Read Read Write Write No Operation No Operation Bank 2 No Operation Write Read No Operation Read Write Note: For the purposes of this table, write means to perform Blockor Sector-Erase or Program operations as applicable to the appropriate bank. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 2 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet Sector- (Block-) Erase Operation These devices offer both Sector-Erase and Block-Erase operations. These operations allow the system to erase the devices on a sector-by-sector (or block-by-block) basis. The sector architecture is based on a uniform sector size of 2 KWord. The Block-Erase mode is based on a uniform block size of 32 KWord. The Sector-Erase operation is initiated by executing a six-byte command sequence with a SectorErase command (50H) and sector address (SA) in the last bus cycle. The Block-Erase operation is initiated by executing a six-byte command sequence with Block-Erase command (30H) and block address (BA) in the last bus cycle. The sector or block address is latched on the falling edge of the sixth WE# pulse, while the command (30H or 50H) is latched on the rising edge of the sixth WE# pulse. The internal Erase operation begins after the sixth WE# pulse. Any commands issued during the Sector- or Block-Erase operation are ignored except Erase-Suspend and EraseResume. See Figures 9 and 10 for timing waveforms. Erase-Suspend/Erase-Resume Operations The Erase-Suspend operation temporarily suspends a Sector- or Block-Erase operation thus allowing data to be read from any memory location, or program data into any sector/block that is not suspended for an Erase operation. The operation is executed by issuing a one-byte command sequence with Erase-Suspend command (B0H). The device automatically enters read mode no more than 10 µs after the Erase-Suspend command had been issued. (TES maximum latency equals 10 µs.) Valid data can be read from any sector or block that is not suspended from an Erase operation. Reading at address location within erasesuspended sectors/blocks will output DQ2 toggling and DQ6 at “1”. While in Erase-Suspend mode, a Program operation is allowed except for the sector or block selected for Erase-Suspend. The Software ID Entry command can also be executed. To resume Sector-Erase or Block-Erase operation which has been suspended, the system must issue an Erase-Resume command. The operation is executed by issuing a one-byte command sequence with Erase Resume command (30H) at any address in the last byte sequence. Chip-Erase Operation The devices provide a Chip-Erase operation, which allows the user to erase all sectors/blocks to the “1” state. This is useful when a device must be quickly erased. The Chip-Erase operation is initiated by executing a sixbyte command sequence with Chip-Erase command (10H) at address 555H in the last byte sequence. The Erase operation begins with the rising edge of the sixth WE# or CE#, whichever occurs first. During the Erase operation, the only valid Read is Toggle Bit or Data# Polling. Any commands issued during the Chip-Erase operation are ignored. See Table 7 for the command sequence, Figure 8 for timing diagram, and Figure 22 for the flowchart. When WP# is low, any attempt to Chip-Erase will be ignored. Write Operation Status Detection These devices provide one hardware and two software means to detect the completion of a Write (Program or Erase) cycle in order to optimize the system Write cycle time. The hardware detection uses the Ready/Busy# (RY/ BY#) output pin. The software detection includes two status bits: Data# Polling (DQ7) and Toggle Bit (DQ6). The End-of-Write detection mode is enabled after the rising edge of WE#, which initiates the internal Program or Erase operation. The actual completion of the nonvolatile write is asynchronous with the system; therefore, either a Ready/Busy# (RY/ BY#), a Data# Polling (DQ7), or Toggle Bit (DQ6) Read may be simultaneous with the completion of the Write cycle. If this occurs, the system may get an erroneous result, i.e., valid data may appear to conflict with either DQ7 or DQ6. In order to prevent spurious rejection if an erroneous result occurs, the software routine should include a loop to read the accessed location an additional two (2) times. If both Reads are valid, then the Write cycle has completed, otherwise the rejection is valid. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 3 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet Ready/Busy# (RY/BY#) The devices include a Ready/Busy# (RY/BY#) output signal. RY/BY# is an open drain output pin that indicates whether an Erase or Program operation is in progress. Since RY/BY# is an open drain output, it allows several devices to be tied in parallel to VDD via an external pull-up resistor. After the rising edge of the final WE# pulse in the command sequence, the RY/BY# status is valid. When RY/BY# is actively pulled low, it indicates that an Erase or Program operation is in progress. When RY/BY# is high (Ready), the devices may be read or left in standby mode. Toggle Bits (DQ6 and DQ2) During the internal Program or Erase operation, any consecutive attempts to read DQ6 will produce alternating “1”s and “0”s, i.e., toggling between 1 and 0. When the internal Program or Erase operation is completed, the DQ6 bit will stop toggling. The device is then ready for the next operation. The toggle bit is valid after the rising edge of the fourth WE# (or CE#) pulse for Program operations. For Sector-, Block-, or Chip-Erase, the toggle bit (DQ6) is valid after the rising edge of sixth WE# (or CE#) pulse. DQ6 will be set to “1” if a Read operation is attempted on an Erase-suspended Sector/Block. If Program operation is initiated in a sector/block not selected in Erase-Suspend mode, DQ6 will toggle. An additional Toggle Bit is available on DQ2, which can be used in conjunction with DQ6 to check whether a particular sector is being actively erased or erase-suspended. Table 1 shows detailed status bit information. The Toggle Bit (DQ2) is valid after the rising edge of the last WE# (or CE#) pulse of a Write operation. See Figure 7 for Toggle Bit timing diagram and Figure 20 for a flowchart. TABLE 1: WRITE OPERATION STATUS Status Normal Standard Operation Program Standard Erase EraseSuspend Mode Read From Erase Suspended Sector/Block Read From Non-Erase Suspended Sector/Block Program DQ7 DQ7# 0 1 DQ6 Toggle Toggle 1 DQ2 No Toggle Toggle Toggle RY/BY# 0 0 1 Byte/Word (BYTE#) The device includes a BYTE# pin to control whether the device data I/O pins operate x8 or x16. If the BYTE# pin is at logic “1” (VIH) the device is in x16 data configuration: all data I/0 pins DQ0-DQ15 are active and controlled by CE# and OE#. If the BYTE# pin is at logic “0”, the device is in x8 data configuration: only data I/O pins DQ0-DQ7 are active and controlled by CE# and OE#. The remaining data pins DQ8DQ14 are at Hi-Z, while pin DQ15 is used as the address input A-1 for the Least Significant Bit of the address bus. Data# Polling (DQ7) When the devices are in an internal Program operation, any attempt to read DQ7 will produce the complement of the true data. Once the Program operation is completed, DQ7 will produce true data. During internal Erase operation, any attempt to read DQ7 will produce a ‘0’. Once the internal Erase operation is completed, DQ7 will produce a ‘1’. The Data# Polling is valid after the rising edge of fourth WE# (or CE#) pulse for Program operation. For Sector-, Block-, or Chip-Erase, the Data# Polling is valid after the rising edge of sixth WE# (or CE#) pulse. See Figure 6 for Data# Polling (DQ7) timing diagram and Figure 20 for a flowchart. Data Data Data 1 DQ7# Toggle N/A 0 T1.1 1270 Note: DQ7, DQ6, and DQ2 require a valid address when reading status information. The address must be in the bank where the operation is in progress in order to read the operation status. If the address is pointing to a different bank (not busy), the device will output array data. Data Protection The devices provide both hardware and software features to protect nonvolatile data from inadvertent writes. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 4 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet Hardware Data Protection Noise/Glitch Protection: A WE# or CE# pulse of less than 5 ns will not initiate a Write cycle. VDD Power Up/Down Detection: The Write operation is inhibited when VDD is less than 1.5V. Write Inhibit Mode: Forcing OE# low, CE# high, or WE# high will inhibit the Write operation. This prevents inadvertent writes during power-up or power-down. Software Data Protection (SDP) These devices provide the JEDEC standard Software Data Protection scheme for all data alteration operations, i.e., Program and Erase. Any Program operation requires the inclusion of the three-byte sequence. The three-byte load sequence is used to initiate the Program operation, providing optimal protection from inadvertent Write operations, e.g., during the system power-up or power-down. Any Erase operation requires the inclusion of the six-byte sequence. The devices are shipped with the Software Data Protection permanently enabled. See Table 7 for the specific software command codes. During SDP command sequence, invalid commands will abort the device to Read mode within TRC. The contents of DQ15-DQ8 can be VIL or VIH, but no other value during any SDP command sequence. Hardware Block Protection The devices provide hardware block protection which protects the outermost 8 KWord in the smaller bank. The block is protected when WP# is held low. When WP# is held low and a Block-Erase command is issued to the protected black, the data in the outermost 8 KWord/16 KByte section will be protected. The rest of the block will be erased. See Tables 3 and 4 for Block-Protection location. A user can disable block protection by driving WP# high. This allows data to be erased or programmed into the protected sectors. WP# must be held high prior to issuing the Write command and remain stable until after the entire Write operation has completed. If WP# is left floating, it is internally held high via a pull-up resistor, and the Boot Block is unprotected, enabling Program and Erase operations on that block. Common Flash Memory Interface (CFI) These devices also contain the CFI information to describe the characteristics of the devices. In order to enter the CFI Query mode, the system must write the three-byte sequence, same as the Software ID Entry command with 98H (CFI Query command) to address BKX555H in the last byte sequence. In order to enter the CFI Query mode, the system can also use the one-byte sequence with BKX55H on Address and 98H on Data Bus. See Figure 12 for CFI Entry and Read timing diagram. Once the device enters the CFI Query mode, the system can read CFI data at the addresses given in Tables 8 through 10. The system must write the CFI Exit command to return to Read mode from the CFI Query mode. Hardware Reset (RST#) The RST# pin provides a hardware method of resetting the devices to read array data. When the RST# pin is held low for at least TRP, any in-progress operation will terminate and return to Read mode (see Figure 16) and all output pins are set to High-Z. When no internal Program/Erase operation is in progress, a minimum period of TRHR is required after RST# is driven high before a valid Read can take place (see Figure 15). The Erase operation that has been interrupted needs to be reinitiated after the device resumes normal operation mode to ensure data integrity. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 5 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet Security ID The SST36VF320x devices offer a 136-word Security ID space. The Secure ID space is divided into two segments—one 128-bit factory programmed segment and one 128-word (256-byte) user-programmed segment. The first segment is programmed and locked at SST with a unique, 128-bit number. The user segment is left un-programmed for the customer to program as desired. To program the user segment of the Security ID, the user must use the Security ID Program command. End-of-Write status is checked by reading the toggle bits. Data# Polling is not used for Security ID End-of-Write detection. Once programming is complete, the Sec ID should be locked using the User Sec ID Program Lock-Out. This disables any future corruption of this space. Note that regardless of whether or not the Sec ID is locked, neither Sec ID segment can be erased. The Secure ID space can be queried by executing a three-byte command sequence with Query Sec ID command (88H) at address 555H in the last byte sequence. See Figure 14 for timing diagram. To exit this mode, the Exit Sec ID command should be executed. Refer to Table 7 for more details. address from the same bank without issuing a new Software ID Entry command. The Software ID Entry command may be written to an address within a bank that is in Read Mode or in Erase-Suspend mode. The Software ID Entry command may not be written while the device is programming or erasing in the other bank. TABLE 2: PRODUCT IDENTIFICATION Address Manufacturer’s ID Device ID SST36VF3203 SST36VF3204 Note: BKX = Bank Address (A20-A18) Data 00BFH 7354H 7353H T2.1 1270 BKX0000H BKX0001H BKX0001H Product Identification Mode Exit/CFI Mode Exit In order to return to the standard Read mode, the Software Product Identification mode must be exited. Exit is accomplished by issuing the Software ID Exit command sequence, which returns the device to the Read mode. This command may also be used to reset the device to the Read mode after any inadvertent transient condition that apparently causes the device to behave abnormally, e.g., not read correctly. Please note that the Software ID Exit/CFI Exit command is ignored during an internal Program or Erase operation. See Table 7 for the software command code, Figure 13 for timing waveform and Figure 21 for a flowchart. Product Identification The Product Identification mode identifies the devices and manufacturer. For details, see Table 2 for software operation, Figure 11 for the Software ID Entry and Read timing diagram and Figure 21 for the Software ID Entry command sequence flowchart. The addresses A20 and A18 indicate a bank address. When the addressed bank is switched to Product Identification mode, it is possible to read another FUNCTIONAL BLOCK DIAGRAM Memory Address Address Buffers (8 KWord / 16 KByte Sector Protection) SuperFlash Memory Bank 1 BYTE# RST# CE# WP# WE# OE# RY/BY# 1270 B01.0 SuperFlash Memory Bank 2 Control Logic I/O Buffers DQ15/A-1 - DQ0 ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 6 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 3: SST36VF3203, 2M X16 CSF BOTTOM DUAL-BANK MEMORY ORGANIZATION (1 OF 2) SST36VF3203 Block BA0 BA1 BA2 BA3 BA4 BA5 BA6 Bank 1 BA7 BA8 BA9 BA10 BA11 BA12 BA13 BA14 BA15 BA16 BA17 BA18 BA19 BA20 BA21 BA22 BA23 BA24 BA25 BA26 BA27 Bank 2 BA28 BA29 BA30 BA31 BA32 BA33 BA34 BA35 BA36 BA37 BA38 BA39 BA40 BA41 Block Size 8 KW / 16 KB 24 KW / 48 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB Address Range x8 000000H–003FFFH 004000H–00FFFFH 010000H–01FFFFH 020000H–02FFFFH 030000H–03FFFFH 040000H–04FFFFH 050000H–05FFFFH 060000H—06FFFFH 070000H—07FFFFH 080000H—08FFFFH 090000H—09FFFFH 0A0000H—0AFFFFH 0B0000H—0BFFFFH 0C0000H—0CFFFFH 0D0000H—0DFFFFH 0E0000H—0EFFFFH 0F0000H—0FFFFFH 100000H—10FFFFH 110000H—11FFFFH 120000H—12FFFFH 130000H—13FFFFH 140000H—14FFFFH 150000H—15FFFFH 160000H—16FFFFH 170000H—17FFFFH 180000H—18FFFFH 190000H—19FFFFH 1A0000H—1AFFFFH 1B0000H—1BFFFFH 1C0000H—1CFFFFH 1D0000H—1DFFFFH 1E0000H—1EFFFFH 1F0000H—1FFFFFH 200000H—20FFFFH 210000H—21FFFFH 220000H—22FFFFH 230000H—23FFFFH 240000H—24FFFFH 250000H—25FFFFH 260000H—26FFFFH 270000H—27FFFFH 280000H—28FFFFH 290000H—29FFFFH Address Range x16 000000H–001FFFH 002000H–007FFFH 008000H–00FFFFH 010000H–017FFFH 018000H–01FFFFH 020000H–027FFFH 028000H–02FFFFH 030000H–037FFFH 038000H–03FFFFH 040000H–047FFFH 048000H–04FFFFH 050000H–057FFFH 058000H–05FFFFH 060000H–067FFFH 068000H–06FFFFH 070000H–077FFFH 078000H–07FFFFH 080000H–087FFFH 088000H–08FFFFH 090000H–097FFFH 098000H–09FFFFH 0A0000H–0A7FFFH 0A8000H–0AFFFFH 0B0000H–0B7FFFH 0B8000H–0BFFFFH 0C0000H–0C7FFFH 0C8000H–0CFFFFH 0D0000H–0D7FFFH 0D8000H–0DFFFFH 0E0000H—0E7FFFH 0E8000H—0EFFFFH 0F0000H—0F7FFFH 0F8000H—0FFFFFH 100000H—107FFFH 108000H—10FFFFH 110000H—117FFFH 118000H—11FFFFH 120000H—127FFFH 128000H—12FFFFH 130000H—137FFFH 138000H—13FFFFH 140000H—147FFFH 148000H—14FFFFH ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 7 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 3: SST36VF3203, 2M X16 CSF BOTTOM DUAL-BANK MEMORY ORGANIZATION (CONTINUED) (2 OF 2) SST36VF3203 Block BA42 BA43 BA44 BA45 BA46 BA47 BA48 BA49 BA50 BA51 Bank 2 BA52 BA53 BA54 BA55 BA56 BA57 BA58 BA59 BA60 BA61 BA62 BA63 Block Size 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB Address Range x8 2A0000H—2AFFFFH 2B0000H–2BFFFFH 2C0000H–2CFFFFH 2D0000H–2DFFFFH 2E0000H–2EFFFFH 2F0000H–2FFFFFH 300000H–30FFFFH 310000H–31FFFFH 320000H–32FFFFH 330000H–33FFFFH 340000H–34FFFFH 350000H–35FFFFH 360000H–36FFFFH 370000H–37FFFFH 380000H–38FFFFH 390000H–39FFFFH 3A0000H–3AFFFFH 3B0000H–3BFFFFH 3C0000H–3CFFFFH 3D0000H–3DFFFFH 3E0000H–3EFFFFH 3F0000H–3FFFFFH Address Range x16 150000H—157FFFH 158000H–15FFFFH 160000H–167FFFH 168000H–16FFFFH 170000H–177FFFH 178000H–17FFFFH 180000H–187FFFH 188000H–18FFFFH 190000H–197FFFH 198000H–19FFFFH 1A0000H–1A7FFFH 1A8000H–1AFFFFH 1B0000H–1B7FFFH 1B8000H–1BFFFFH 1C0000H–1C7FFFH 1C8000H–1CFFFFH 1D0000H–1D7FFFH 1D8000H–1DFFFFH 1E0000H–1E7FFFH 1E8000H–1EFFFFH 1F0000H–1F7FFFH 1F8000H–1FFFFFH T3.0 1270 ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 8 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 4: SST36VF3204, 2M X16 CSF TOP DUAL-BANK MEMORY ORGANIZATION (1 OF 2) SST36VF3204 Block BA0 BA1 BA2 BA3 BA4 BA5 BA6 BA7 BA8 BA9 BA10 BA11 BA12 BA13 BA14 BA15 BA16 BA17 BA18 BA19 BA20 Bank 2 BA21 BA22 BA23 BA24 BA25 BA26 BA27 BA28 BA29 BA30 BA31 BA32 BA33 BA34 BA35 BA36 BA37 BA38 BA39 BA40 BA41 BA42 Block Size 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB Address Range x8 000000H–00FFFFH 010000H–01FFFFH 020000H–02FFFFH 030000H–03FFFFH 040000H–04FFFFH 050000H–05FFFFH 060000H—06FFFFH 070000H—07FFFFH 080000H—08FFFFH 090000H—09FFFFH 0A0000H—0AFFFFH 0B0000H—0BFFFFH 0C0000H—0CFFFFH 0D0000H—0DFFFFH 0E0000H—0EFFFFH 0F0000H—0FFFFFH 100000H—10FFFFH 110000H—11FFFFH 120000H—12FFFFH 130000H—13FFFFH 140000H—14FFFFH 150000H—15FFFFH 160000H—16FFFFH 170000H—17FFFFH 180000H—18FFFFH 190000H—19FFFFH 1A0000H—1AFFFFH 1B0000H—1BFFFFH 1C0000H—1CFFFFH 1D0000H—1DFFFFH 1E0000H—1EFFFFH 1F0000H—1FFFFFH 200000H—20FFFFH 210000H—21FFFFH 220000H—22FFFFH 230000H—23FFFFH 240000H—24FFFFH 250000H—25FFFFH 260000H—26FFFFH 270000H—27FFFFH 280000H—28FFFFH 290000H—29FFFFH 2A0000H—2AFFFFH Address Range x16 000000H–007FFFH 008000H–00FFFFH 010000H–017FFFH 018000H–01FFFFH 020000H–027FFFH 028000H–02FFFFH 030000H–037FFFH 038000H–03FFFFH 040000H–047FFFH 048000H–04FFFFH 050000H–057FFFH 058000H–05FFFFH 060000H–067FFFH 068000H–06FFFFH 070000H–077FFFH 078000H–07FFFFH 080000H–087FFFH 088000H–08FFFFH 090000H–097FFFH 098000H–09FFFFH 0A0000H–0A7FFFH 0A8000H–0AFFFFH 0B0000H–0B7FFFH 0B8000H–0BFFFFH 0C0000H–0C7FFFH 0C8000H–0CFFFFH 0D0000H–0D7FFFH 0D8000H–0DFFFFH 0E0000H–0E7FFFH 0E8000H–0EFFFFH 0F0000H–0F7FFFH 0F8000H–0FFFFFH 100000H–107FFFH 108000H–10FFFFH 110000H–117FFFH 118000H–11FFFFH 120000H–127FFFH 128000H–12FFFFH 130000H–137FFFH 138000H–13FFFFH 140000H–147FFFH 148000H–14FFFFH 150000H–157FFFH ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 9 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 4: SST36VF3204, 2M X16 CSF TOP DUAL-BANK MEMORY ORGANIZATION (CONTINUED) (2 OF 2) SST36VF3204 Block BA43 BA44 Bank 2 BA45 BA46 BA47 BA48 BA49 BA50 BA51 BA52 BA53 BA54 BA55 Bank 1 BA56 BA57 BA58 BA59 BA60 BA61 BA62 BA63 Block Size 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 32 KW / 64 KB 24 KW / 48 KB 8 KW / 16 KB Address Range x8 2B0000H–2BFFFFH 2C0000H–2CFFFFH 2D0000H–2DFFFFH 2E0000H–2EFFFFH 2F0000H–2FFFFFH 300000H–30FFFFH 310000H–31FFFFH 320000H–32FFFFH 330000H–33FFFFH 340000H–34FFFFH 350000H–35FFFFH 360000H–36FFFFH 370000H–37FFFFH 380000H–38FFFFH 390000H–39FFFFH 3A0000H–3AFFFFH 3B0000H–3BFFFFH 3C0000H–3CFFFFH 3D0000H–3DFFFFH 3E0000H–3EFFFFH 3F0000H–3FBFFFH 3FC000H–3FFFFFH Address Range x16 158000H–15FFFFH 160000H–167FFFH 168000H–16FFFFH 170000H–177FFFH 178000H–17FFFFH 180000H–187FFFH 188000H–18FFFFH 190000H–197FFFH 198000H–19FFFFH 1A0000H–1A7FFFH 1A8000H–1AFFFFH 1B0000H–1B7FFFH 1B8000H–1BFFFFH 1C0000H–1C7FFFH 1C8000H–1CFFFFH 1D0000H–1D7FFFH 1D8000H–1DFFFFH 1E0000H–1E7FFFH 1E8000H–1EFFFFH 1F0000H–1F7FFFH 1F8000H–1FDFFFH 1FE000H–1FFFFFH T4.0 1270 ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 10 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TOP VIEW (balls facing down) 6 5 4 A13 A12 A14 A15 A16 BYTE# A9 A8 NOTE* VSS A10 A11 DQ7 DQ14 DQ13 DQ6 A19 DQ5 DQ12 VDD DQ4 1270 48-tfbga P1.0 WE# RST# NC 3 2 1 A7 A3 A17 A4 A6 A2 RY/BY# WP# A18 A20 DQ2 DQ10 DQ11 DQ3 A5 A1 DQ0 DQ8 DQ9 DQ1 A0 CE# OE# VSS A B C D E F G H Note* = DQ15/A-1 FIGURE 1: PIN ASSIGNMENTS FOR 48-BALL TFBGA (6MM X 8MM) A15 A14 A13 A12 A11 A10 A9 A8 A19 A20 WE# RST# NC WP# RY/BY# A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Standard Pinout Top View Die Up 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VDD DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 1270 48-tsop P02.0 FIGURE 2: PIN ASSIGNMENTS FOR 48-LEAD TSOP (12MM X 20MM) ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 11 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 5: PIN DESCRIPTION Symbol A20-A0 Name Address Inputs Functions To provide memory addresses. During Sector-Erase and Hardware Sector Protection, A20-A11 address lines will select the sector. During Block-Erase A20-A15 address lines will select the block. To output data during Read cycles and receive input data during Write cycles Data is internally latched during a Write cycle. The outputs are in tri-state when OE# or CE# is high. DQ15 is used as data I/O pin when in x16 mode (BYTE# = “1”) A-1 is used as the LSB address pin when in x8 mode (BYTE# = “0”) To activate the device when CE# is low. To gate the data output buffers To control the Write operations To reset and return the device to Read mode To output the status of a Program or Erase operation RY/BY# is a open drain output, so a 10KΩ - 100KΩ pull-up resistor is required to allow RY/BY# to transition high indicating the device is ready to read. To protect and unprotect top or bottom 8 KWord (4 outermost sectors) from Erase or Program operation. To provide 2.7-3.6V power supply voltage Unconnected pins T5.0 1270 DQ14-DQ0 Data Input/Output DQ15/A-1 CE# OE# WE# RST# RY/BY# Data Input/Output and LBS Address Chip Enable Output Enable Write Enable Hardware Reset Ready/Busy# WP# BYTE# VDD VSS NC Write Protect Word/Byte Configuration To select 8-bit or 16-bit mode. Power Supply Ground No Connection TABLE 6: OPERATION MODES SELECTION DQ15-DQ8 Mode Read Program Erase CE# OE# WE# VIL VIL VIL VIL VIH VIH VIH VIL VIL RST# VIH VIH VIH DQ7-DQ0 DOUT DIN X1 BYTE# = VIH DOUT DIN X BYTE# = VIL DQ14-DQ8 = High Z DQ15 = A-1 High Z Address AIN AIN Sector or Block address, 555H for Chip-Erase X X X Standby Write Inhibit Product Identification Software Mode Reset VIHC X X X VIL X X X VIH VIHC VIH VIH High Z High Z / DOUT High Z / DOUT High Z High Z / DOUT High Z / DOUT High Z High Z High Z VIL VIL VIH VIH Manufacturer’s ID (BFH) Device ID2 High Z Manufacturer’s ID (00H) Device ID2 High Z High Z High Z High Z See Table 7 X X X VIL X T6.1 1270 1. X can be VIL or VIH, but no other value. 2. Device ID = SST36VF3203 = 7354H, SST36VF3204 = 7353H ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 12 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 7: SOFTWARE COMMAND SEQUENCE Command Sequence Word-Program Sector-Erase Block-Erase Chip-Erase Erase-Suspend Erase-Resume Query Sec ID5 User Security ID Word-Program User Security ID Program Lock-out7 Software ID Entry8,9 CFI Query Entry9 CFI Query Entry9 Software ID Exit/ CFI Exit/ Sec ID Exit10,11 Software ID Exit/ CFI Exit/ Sec ID Exit10,11 1st Bus Write Cycle Addr1 555H 555H 555H 555H XXXH XXXH 555H 555H 555H 555H 555H BKX4 55H 555H 2nd Bus Write Cycle Addr1 2AAH 2AAH 2AAH 2AAH 3rd Bus Write Cycle Addr1 555H 555H 555H 555H 4th Bus Write Cycle Addr1 WA3 555H 555H 555H 5th Bus Write Cycle Addr1 2AAH 2AAH 2AAH 6th Bus Write Cycle Addr1 SAX4 BAX 4 Data2 AAH AAH AAH AAH B0H 30H AAH AAH AAH AAH AAH 98H AAH Data2 55H 55H 55H 55H Data2 A0H 80H 80H 80H Data2 Data AAH AAH AAH Data2 55H 55H 55H Data2 50H 30H 10H 555H 2AAH 2AAH 2AAH 2AAH 2AAH 55H 55H 55H 55H 55H 555H 555H 555H BKX4 555H BKX4 555H 88H A5H 85H 90H 98H SIWA6 XXXH Data 0000H 2AAH 55H 555H F0H XXH F0H T7.1 1270 1. Address format A10-A0 (Hex), Addresses A20-A11 can be VIL or VIH, but no other value (unless otherwise stated), for the command sequence when in x16 mode. When in x8 mode, Addresses A20-A12, Address A-1, and DQ14-DQ8 can be VIL or VIH, but no other value (unless otherwise stated), for the command sequence. 2. DQ15-DQ8 can be VIL or VIH, but no other value, for the command sequence 3. WA = Program word address 4. SAX for Sector-Erase; uses A20-A11 address lines BAX for Block-Erase; uses A20-A15 address lines BKX for Bank Address; uses A20-A18 address lines 5. For SST36VF3203 the Security ID Address Range is: (x16 mode) = 100000H to 100087H,(x8 mode) = 100000H to 10010FH SST ID is read at Address Range(x16 mode) = 100000H to 100007H (x8 mode) = 100000H to 10000FH User ID is read at Address Range(x16 mode) = 100008H to 100087H (x8 mode) = 100010H to 10010FH Lock status is read at Address 1000FFH (x16) or 1001FFH (x8). Unlocked: DQ3 = 1 / Locked: DQ3 = 0. For SST36VF3204 the Security ID Address Range is:(x16 mode) = 000000H to 000087H, (x8 mode) = 000000H to 00010FH SST ID is read at Address Range (x16 mode) = 000000H to 000007H (x8 mode) = 000000H to 00000FH User ID is read at Address Range (x16 mode) = 000008H to 000087H (x8 mode) = 000010H to 00010FH Lock Status is read at Address 0000FFH (x16) or 0001FFH (x8). Unlocked: DQ3 = 1 / Locked: DQ3 = 0 6. SIWA = Valid Word addresses for user Sec ID For SST36VF3203 User ID valid Address Range is (x16 mode) = 100008H-100087H (x8 mode) = 100010H-10010FH. For SST36VF3204 User ID valid Address Range is (x16 mode) = 000008H-000087H (x8 mode) = 000010H-00010FH. All 4 cycles of User Security ID Program and Program Lock-out must be completed before going back to Read-Array mode. 7. The User Security ID Program Lock-out command must be executed in x16 mode (BYTE#=VIH). 8. The device does not remain in Software Product Identification mode if powered down. 9. A20, A19, and A18 = BKX (Bank Address): address of the bank that is switched to Software ID/CFI Mode With A17-A1 = 0;SST Manufacturer’s ID = 00BFH, is read with A0 = 0 SST36VF3203 Device ID = 7354H, is read with A0 = 1 SST36VF3204 Device ID = 7353H, is read with A0 = 1 10. Both Software ID Exit operations are equivalent 11. If users never lock after programming, User Sec ID can be programmed over the previously unprogrammed bits (data=1) using the User Sec ID mode again (the programmed “0” bits cannot be reversed to “1”). ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 13 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 8: CFI QUERY IDENTIFICATION STRING1 Address x16 Mode 10H 11H 12H 13H 14H 15H 16H 17H 18H 19H 1AH Address x8 Mode 20H 22H 24H 26H 28H 2AH 2CH 2EH 30H 32H 34H Data2 0051H 0052H 0059H 0002H 0000H 0000H 0000H 0000H 0000H 0000H 0000H Description Query Unique ASCII string “QRY” Primary OEM command set Address for Primary Extended Table Alternate OEM command set (00H = none exists) Address for Alternate OEM extended Table (00H = none exits) T8.1 1270 1. Refer to CFI publication 100 for more details. 2. In x8 mode, only the lower byte of data is output. TABLE 9: SYSTEM INTERFACE INFORMATION Address x16 Mode 1BH 1CH 1DH 1EH 1FH 20H 21H 22H 23H 24H 25H 26H Address x8 Mode 36H 38H 3AH 3CH 3EH 40H 42H 44H 46H 48H 4AH 4CH Data1 0027H 0036H 0000H 0000H 0004H 0000H 0004H 0006H 0001H 0000H 0001H 0001H Description VDD Min (Program/Erase) DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts VDD Max (Program/Erase) DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts VPP min (00H = no VPP pin) VPP max (00H = no VPP pin) Typical time out for Program 2N µs (24 = 16 µs) Typical time out for min size buffer program 2N µs (00H = not supported) Typical time out for individual Sector/Block-Erase 2N ms (24 = 16 ms) Typical time out for Chip-Erase 2N ms (26 = 64 ms) Maximum time out for Program 2N times typical (21 x 24 = 32 µs) Maximum time out for buffer program 2N times typical Maximum time out for individual Sector-/Block-Erase 2N times typical (21 x 24 = 32 ms) Maximum time out for Chip-Erase 2N times typical (21 x 26 = 128 ms) T9.0 1270 1. In x8 mode, only the lower byte of data is output. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 14 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet TABLE 10: DEVICE GEOMETRY INFORMATION Address x16 Mode 27H 28H 29H 2AH 2BH 2CH 2DH 2EH 2FH 30H 31H 32H 33H 34H Address x8 Mode 4EH 50H 52H 54H 56H 58H 5AH 5CH 5EH 60H 62H 64H 66H 68H Data1 0016H 0002H 0000H 0000H 0000H 0002H 003FH 0000H 0000H 0001H 00FFH 0003H 0010H 0000H Description Device size = 2N Bytes (16H = 22; 222 = 4 MByte) Flash Device Interface description; 0002H = x8/x16 asynchronous interface Maximum number of bytes in multi-byte write = 2N (00H = not supported) Number of Erase Sector/Block sizes supported by device Block Information (y + 1 = Number of blocks; z x 256B = block size) y = 63 + 1 = 64 blocks (003FH = 63) z = 256 x 256 Bytes = 64 KByte/block (0100H = 256) Sector Information (y + 1 = Number of sectors; z x 256B = sector size) y = 1023 + 1 = 1024 sectors (03FFH = 1023) z = 16 x 256 Bytes = 4 KByte/sector (0010H = 16) T10.2 1270 1. In x8 mode, only the lower byte of data is output. ©2005 Silicon Storage Technology, Inc. S71270-03-000 7/06 15 32 Mbit Concurrent SuperFlash SST36VF3203 / SST36VF3204 Data Sheet Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute Maximum Stress Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these conditions or conditions greater than those defined in the operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.) Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C D. C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V Transient Voltage (
SST36VF3203-70-4I-B3KE 价格&库存

很抱歉,暂时无法提供与“SST36VF3203-70-4I-B3KE”相匹配的价格&库存,您可以联系我们找货

免费人工找货