0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
UW3804X

UW3804X

  • 厂商:

    STANLEY

  • 封装:

  • 描述:

    UW3804X - 3 Flush Mount Type White LED - STANLEY ELECTRIC CO.,LTD.

  • 数据手册
  • 价格&库存
UW3804X 数据手册
UW3804X 3 Flush Mount Type White LED Features Package Product features 3 Flush Mount Type. Water clear resin Outer Dimension 3 Flush Mount Type. Operation temperature range Storage Temperature : -40 100 Operating Temperature : -40 85 Lead–free soldering compatible RoHs compliant Chromaticity coordinates x = 0.31TYP., y = 0.32TYP. (Condition : IF=20mA) Spatial distribution Die materials Rank grouping parameter 40 deg. InGaN Sorted by luminous intensity rank and chromaticity rank Soldering methods ESD Packing TTW (Through The Wave) soldering and manual soldering 1kV (HBM) Bulk : 200pcs(MIN.) Recommended Applications Amusement Equipment, OA/FA, Other General Applications 2006.7.31 Page 1 UW3804X 3 Flush Mount Type White LED Color and Luminous Intensity Part No. Material Emitted Color Lens Color Luminous Intensity Iv (mcd) MIN. TYP. IF UW3804X InGaN White Water Clear 1,000 2,000 20 2004.07.15 Page 2 UW3804X 3 Flush Mount Type White LED Absolute Maximum Ratings Item Power Dissipation Forward Current Pulse Forward Current 1 Derating (Ta=25 or hi gher) Reverse Voltage Operating Temperature Storage Temperature Symbol Pd IF IFRM Absolute Maximum Ratings Unit mW mA mA mA/ V 107 25 60 0.33 VR Topr T stg 5 -40 +85 -40 +100 1 IFRMMeasurement condition : Pulse Width 1ms., Duty 1/20. 2004.07.15 Page 3 UW3804X 3 Flush Mount Type White LED Electro-Optical Characteristics Item Condition IF=20mA Symbol Characteristics TYP. 3.7 Unit Forward Voltage VF MAX. 4.2 100 40 0.31 0.32 V Reverse Current Half Intensity Angle Chromaticity Coordinates VR =5V IF=20mA IR MAX. TYP. deg. - x IF=20mA y TYP. TYP. 2004.07.15 Page 4 UW3804X 3 Flush Mount Type White LED Luminous Intensity Rank Rank A B C D E F I V ( mcd) MIN. MAX. 1,000 2,000 1,400 2,800 2,000 4,000 2,800 5,600 4,000 8,000 5,600 - Condition IF=20mA Please contact our sales staff concerning rank designation. 2004.07.15 Page 5 UW3804X 3 Flush Mount Type White LED Sorting Chart for Chromaticity Coordinates LEFT DOWN point LEFT UP point RIGHT UP point RIGHT UP point Rank 1 2c 2d 2e 2f 3 x 0.280 0.287 0.296 0.307 0.311 0.330 y 0.248 0.295 0.276 0.315 0.294 0.318 x 0.264 0.283 0.287 0.304 0.307 0.330 y 0.267 0.305 0.295 0.330 0.315 0.360 x 0.283 0.304 0.307 0.330 0.330 0.361 y 0.305 0.330 0.315 0.360 0.339 0.385 x 0.296 0.307 0.311 0.330 0.330 0.356 y 0.276 0.315 0.294 0.339 0.318 0.351 The above values are reference values. Please contact our sales staff concerning rank designation. 2004.07.15 Page 6 UW3804X 3 Flush Mount Type White LED Technical Data Relative Intensity vs. wave Length              Condition:IF=20mA , Ta=25 1.00 Spatial Distribution Example Condition : Ta=25 0.80 Relative Intensity 0.60 0.40 0.20 0.00 400 450 500 550 600 650 700 750 波長 /Wave Length[nm] Wavelength[nm] Forward Voltage vs. Forward Current                     Condition:Ta=25 Forward Current vs. Relative Intensity   C ondition:Ta=25 1.5 100 Forward Current IF (mA) 1 Relative Intensity 10 1.0 0.5 0.1 0.01 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.0 0 5 10 15 20 25 30 Forward Voltage VF(V) Forward Current IF(mA) 2004.07.15 Page 7 UW3804X 3 Flush Mount Type White LED Technical Data Ambient Temperature vs. Relative Intensity Ambient Temperature vs. Maximum Forward Current Repeatition Frequency : f 50Hz 70 Duty =5% MAX. ( mA) 10.0 60 Duty =10% 50 40 Duty =50% Maximum Forward Current : IF Relative Intensity 20 40 60 80 100 Duty =20% 1.0 30 DC 20 10 0 -40 -20 0 0.1 -40 -20 0 20 40 60 80 100 Ambient Temperature Ta( ) Ambient Temperature : Ta( ) Ambient Temperature vs. Forward Voltage 120 Ambient Temperature vs. Power Disspation 4.5 100 Power Dissipation : Pd(mW) Forward Voltage VF (V) 4.0 IF = 20mA 80 3.5 IF = 10mA 60 40 3.0 IF = 1mA 20 2.5 -40 -20 0 20 40 60 80 100 120 0 -40 -20 0 20 40 60 80 100 Ambient Temperature Ta( ) Ambient Temperature : Ta( ) 2004.07.15 Page 8 UW3804X 3 Flush Mount Type White LED Technical Data Pulse Width vs. Maximum Tolerable Peak Current Ambient Temperature : Ta=25 10 Duty cycle vs. Maximum Forward Current 100 M aximum Forward C urrent :I F MA X. (mA) 100000 IF peak Max./IF DC Max. 10 10kHz 1kHz 100Hz 50Hz 1 1 10 100 1000 ) 10000 Pulse Width : tw( 1 1 10 Duty (%) 100 2004.07.15 Page 9 UW3804X 3 Flush Mount Type White LED Package Dimensions (Unit: mm) Weight: (0.16)g 2007.11.2 Page 10 UW3804X 3 Flush Mount Type White LED TTW (Through The Wave) soldering Conditions Pre-heating Solder Bath Temp. Dipping Time 100 ℃ 265℃ 5s (MAX.) (MAX.) (MAX.) 1) The dip soldering process shall be 2 times maximum. 2) The product shall be cooled to room temp. before the second dipping process. ※The detail is described to LED and Photodetector handling precautions of home page: "Mounting through-hole Type Devices“ and "Soldering", and use it after the confirmation, please. Manual Soldering Conditions Iron tip temp. Soldering time and frequency 400℃ 3s 2 times (MAX.) (MAX.) (MAX.) ※The detail is described to LED and Photodetector handling precautions of home page: "Mounting through-hole Type Devices“ and "Soldering", and use it after the confirmation, please. 2006.3.31 Page 11 UW3804X 3 Flush Mount Type White LED Reliability Testing Result Reliability Testing Result Room Temp. Operating Life Resistance to Soldering Heat Temperature Cycling Wet High Temp. Storage Life High Temp. Storage Life Low Temp. Storage Life Lead Tension Vibration, Variable Frequency Applicable Standard EIAJ ED4701/100(101) EIAJ ED4701/300(302) EIAJ ED4701/100(105) EIAJ ED4701/100(103) EIAJ ED4701/200(201) EIAJ ED4701/200(202) EIAJ ED4701/400(401) EIAJ ED4701/400(403) Testing Conditions Ta = 25 ℃, IF = Maxium Rated Current 260 ±5 ℃, 1.6mm from package base Minimum Rated Storage Temperature(30min) ~Normal Temperature(15min) ~Maximum Rated Storage Temperature(30min) ~Normal Temperature(15min) Ta = 60 ±2 ℃, RH = 90 ±5% Ta = Maximum Rated Storage Temperature Ta = Minimum Rated Storage Temperature 10N,1time ( 0.4 and Flat Package : 5N) 98.1m/s ( 10G), 100 ~ 2 KHz sweep for 20min., XYZ each direction 2 □ Duration 1,000 h 10s Failure 0/25 0/25 5 cycles 0/25 1,000 h 1,000 h 1,000 h 10s 2h 0/25 0/25 0/25 0/10 0/10 Failure Criteria Items Luminous Intensity Forward Voltage Reverse Current Cosmetic Appearance Symbols Iv VF IR - Conditions IF Value of each product Luminous Intensity IF Value of each product Forward Voltage VR = Maximum Rated Reverse Voltage V - Failure criteria Testing Min. Value < Spec. Min. Value x 0.5 Testing Max. Value ≧ Spec. Max. Value x 1.2 Testing Max. Value ≧ Spec. Max. Value x 2.5 Occurrence of notable decoloration, deformation and cracking 2007.10.26 Page 12 UW3804X 3 Flush Mount Type White LED Special Notice to Customers Using the Products and Technical Information Shown in This Data Sheet 1) The technical information shown in the data sheets are limited to the typical characteristics and circuit examples of the referenced products. It does not constitute the warranting of industrial property nor the granting of any license. 2) For the purpose of product improvement, the specifications, characteristics and technical data described in the data sheets are subject to change without prior notice. Therefore it is recommended that the most updated specifications be used in your design. 3) When using the products described in the data sheets, please adhere to the maximum ratings for operating voltage, heat dissipation characteristics, and other precautions for use. We are not responsible for any damage which may occur if these specifications are exceeded. 4) The products that have been described to this catalog are manufactured so that they will be used for the electrical instrument of the benchmark (OA equipment, telecommunications equipment, AV machine, home appliance and measuring instrument). The application of aircrafts, space borne application, transportation equipment, medical equipment and nuclear power control equipment, etc. needs a high reliability and safety, and the breakdown and the wrong operation might influence the life or the human body. Please consult us beforehand if you plan to use our product for the usages of aircrafts, space borne application, transportation equipment, medical equipment and nuclear power control equipment, etc. except OA equipment, telecommunications equipment, AV machine, home appliance and measuring instrument. 5) In order to export the products or technologies described in this data sheet which are under the “Foreign Exchange and Foreign Trade Control Law,” it is necessary to first obtain an export permit from the Japanese government. 6) No part of this data sheet may be reprinted or reproduced without prior written permission from Stanley Electric Co., Ltd. 7) The most updated edition of this data sheet can be obtained from the address below: http://www.stanley-components.com 2007.10.26 Page 13
UW3804X 价格&库存

很抱歉,暂时无法提供与“UW3804X”相匹配的价格&库存,您可以联系我们找货

免费人工找货