SPC56xL70, SPC56xL64
Errata sheet
SPC56xL70, SPC56xL64 devices errata
JTAG_ID = 0X0AEA_9041
Introduction
This errata sheet describes all the functional and electrical problems known in the cut 2 of
the SPC56xL70, SPC56xL64 devices, identified with the JTAG_ID = 0X0AEA_9041.
All the topics covered in this document refer to RM0342 and SPC56xL70xx datasheet (see
Appendix A: Additional information).
Device identification:
JTAG ID = 0x0AEA_9041
MCU ID Register 1 (MIDR1):
– MAJOR MASK[3:0] = 0x1
– MINOR MASK[3:0] = 0x0
March 2018
DocID023968 Rev 6
1/22
www.st.com
1
Contents
SPC56xL70, SPC56xL64
Contents
1
Functional problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1
ERR000063: MC_ME: ME_PCTL18 not protected by the register protection
.......................................................... 5
2/22
1.2
ERR003320: Flash: single bit correction status is not available in the Error
Correction Status Module (ECSM) and in the Fault Collection and Control
Unit (FCCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3
ERR003511: FlexPWM : Incorrect PWM operation when IPOL is set. . . . 5
1.4
ERR003697: e200z: Exceptions generated on speculative prefetch . . . . . 6
1.5
ERR004016: ADC: Presampling on channels 9, 10, 15 leads to incorrect
results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.6
ERR004168: ADC: "Abort switch" aborts the ongoing injected channel as
well as the upcoming normal channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.7
ERR004186: ADC: Do not trigger ABORT or ABORTCHAIN prior to the start
of CTU triggered ADC conversions and do not trigger ABORTCHAIN prior to
the start of INJECTED triggered ADC conversions. . . . . . . . . . . . . . . . . . . 7
1.8
ERR004334: MC_RGM: Device stays in reset state on external reset
assertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.9
ERR004340: LINFlexD: Buffer overrun can not be detected in UART Rx
FIFO mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.10
ERR006481: NZ4C3/NZ7C3: Erroneous Resource Full Message under
certain conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.11
ERR006726: NPC: MCKO clock may be gated one clock period early when
MCKO frequency is programmed as SYS_CLK/8.and gating is enabled . . 9
1.12
ERR006967: eDMA: Possible misbehavior of a preempted channel when
using continuous link mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.13
ERR007120: NZxC3: DQTAG implemented as variable length field in DQM
message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.14
ERR007227: FCCU: FCCU Output Supervision Unit (FOSU) will not monitor
faults enabled while already pending . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.15
ERR007274: LINFlexD: Consecutive headers received by LIN Slave triggers
the LIN FSM to an unexpected state. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.16
ERR007322: FlexCAN: Bus Off Interrupt bit is erroneously asserted when
soft reset is performed while FlexCAN is in Bus Off state . . . . . . . . . . . . 12
1.17
ERR007352: DSPI: reserved bits in slave CTAR are writable . . . . . . . . . 12
1.18
ERR007394: MC_ME: Incorrect mode may be entered on low-power mode
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Contents
1.19
ERR007589: LINFlexD: Spurious timeout error when switching from UART
to LIN mode or when resetting LINTCSR[MODE] bit in LIN mode . . . . . . 13
1.20
ERR007877: FlexPWM: do not enable the fault filter . . . . . . . . . . . . . . . . 14
1.21
ERR008070: SWG: GPIO[55] functionality is not available unless the SWG
is powered down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.22
ERR008080: LINFlexD: TX pin gets set to High-Z when in IDLE state . . 14
1.23
ERR008933: LINFlexD: Inconsistent sync field may cause an incorrect baud
rate and Sync Field Error Flag may not be set . . . . . . . . . . . . . . . . . . . . . 15
1.24
ERR008970: LINFlexD: Spurious bit error in extended frame mode may
cause an incorrect Idle State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.25
ERR009682: SPI: Inconsistent loading of shift register data into the receive
FIFO following an overflow event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.26
ERR009849: BAM: Serial boot not supported when flash is programmed
with Power Architecture instruction set software . . . . . . . . . . . . . . . . . . . 17
1.27
ERR009928: FlexPWM: Half cycle automatic fault clearing does not work in
PWM submodule 0 under some conditions . . . . . . . . . . . . . . . . . . . . . . . 17
1.28
ERR009976: DSPI: Incorrect data received by master with Modified transfer
format enabled when using Continuous serial communication clock mode .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.29
DAN-0046129 STCU: Pattern to run the MBIST-only wrong . . . . . . . . . . 18
Appendix A Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
A.1
Reference document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
A.2
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DocID023968 Rev 6
3/22
3
List of tables
SPC56xL70, SPC56xL64
List of tables
Table 1.
Table 2.
4/22
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
1
Functional problems
1.1
ERR000063: MC_ME: ME_PCTL18 not protected by the
register protection
Description:
ME_PCTL18 is used to select the configuration of FlexCAN_2 during run and non-run
modes. This register can't be protected by the register protection.
ME_PCTL16 and MC_PCTL17, which are related to FlexCAN_0 and FlexCAN_1, are not
impacted by this issue.
Workaround:
The device embeds different mechanisms to protect resources against unwanted access,
e.g. MPU and AIPS. Use these mechanisms to protect the ME_PCTL18 register against
unexpected writing access.
1.2
ERR003320: Flash: single bit correction status is not
available in the Error Correction Status Module (ECSM) and
in the Fault Collection and Control Unit (FCCU)
Description:
A single bit error correction by the Flash is not passed to the Error Correction Status Module
(ECSM) and to the Fault Collection and Control Unit (FCCU). The single bit error correction
is only flagged by the SBC bit of the Flash Module Configuration Register (MCR).
Workaround:
Poll the SBC bit (Single Bit Correction Status) of the Flash Module Configuration Register
(MCR) to detect a single bit error correction event.
1.3
ERR003511: FlexPWM : Incorrect PWM operation when IPOL
is set.
Description:
When IPOL bit is set in complementary mode, the source of the PWMi waveform is
supposed to be switched from the VAL2 and VAL3 registers to the VAL4 and VAL5 registers.
This switch doesn’t happen.
Workaround:
Instead of setting IPOL bit, the application can swap the VAL2/3 values with the VAL4/5
values.
DocID023968 Rev 6
5/22
21
Functional problems
1.4
SPC56xL70, SPC56xL64
ERR003697: e200z: Exceptions generated on speculative
prefetch
Description:
The e200z4 core can prefetch up to 2 cache lines (64 bytes total) beyond the current
instruction execution point. If a bus error occurs when reading any of these prefetch
locations, the machine check exception will be taken. For example, executing code within
the last 64 bytes of a memory region such as internal SRAM, may cause a bus error when
the core prefetches past the end of memory. An ECC exception can occur if the core
prefetches locations that are valid, but not yet initialized for ECC.
Workaround:
Do not place code to be executed within the last 64 bytes of a memory region. When
executing code from internal ECC SRAM, initialize memory beyond the end of the code until
the next 32-byte aligned address and then an additional 64 bytes to ensure that prefetches
cannot land in uninitialized SRAM.
1.5
ERR004016: ADC: Presampling on channels 9, 10, 15 leads
to incorrect results
Description:
On ADC channels 9 (for factory test only), 10 (VREG_1.2V), 15 (TSENS) when performing
presampling using VSS_HV_ADR (PREVAL0=01) and bypassing the sampling
(PRECONV=1) results in an incorrect converted presampled value.
Workaround:
ADC Conversion Timing Register 1 (CTR1) and Presampling Control Register (PSCR), field
PREVAL1(bits 27:28) can be programmed to select the conversion durations and reference
voltages for ADC channels 9, 10, 15.
1.6
ERR004168: ADC: "Abort switch" aborts the ongoing
injected channel as well as the upcoming normal channel
Description:
If an Injected chain (jch1,jch2,jch3) is injected over a Normal chain (nch1,ch2,ch3,ch4) the
Abort switch doesn't behave as expected.
Expected behavior:
Correct Case (without SW Abort on jch3): Nch1-> Nch2(aborted)->Jch1 -> Jch2> Jch3 -
>Nch2(restored)-> Nch3->Nch4
Correct Case (with SW Abort on jch3): Nch1-> Nch2(aborted)->Jch1 -> Jch2>
Jch3(aborted) ->Nch2(restored)-> Nch3->Nch4
Observed unexpected behavior:
Fault1 (without SW abort on jch3): Nch1-> Nch2(aborted) ->Jch1 -> Jch2> Jch3 -> Nch3-
>Nch4 (Nch2 not restored)
Fault2 (with SW abort on jch3): Nch1-> Nch2 (aborted) ->Jch1 -> Jch2> Jch3(aborted) -
>Nch4 (Nch2 not restored & Nch3 conversion skipped)
6/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
Workaround:
It's possible to detect the unexpected behavior by using the CEOCFR0 register. The
CEOCFR0.EOC_CHx field will not be set for a not restored or skipped channel, which
indicates this issue has occurred. The CEOCFR0.EOC_CHx fields need to be checked
before the next Normal chain execution (in scan mode). The CEOCFR0.EOC_CHx fields
should be read by every ECH interrupt at the end of every chain execution.
1.7
ERR004186: ADC: Do not trigger ABORT or ABORTCHAIN
prior to the start of CTU triggered ADC conversions and do
not trigger ABORTCHAIN prior to the start of INJECTED
triggered ADC conversions.
Description:
When ADC_MCR[ABORT] or ADC_MCR[ABORTCHAIN] is set prior to the ADC receiving a
CTU trigger, the next CTU triggered ADC conversion will not be performed and further CTU
triggered ADC conversions will be blocked.
When ADC_MCR[ABORTCHAIN] is set prior to the ADC receiving an INJECTED trigger,
the next INJECTED ADC conversion will not be performed. Following the ABORTCHAIN
command the MCU behaviour does not meet the specification as ADC_ISR[JECH] is not set
and ADC_MCR[ABORTCHAIN] is not cleared.
Workaround:
Do not program ADC_MCR[ABORT] or ADC_MCR[ABORTCHAIN] before the start of ADC
conversions.
The case when CTU triggered ADC conversions are blocked should be avoided however it
is possible to reactivate CTU conversions by clearing and setting ADC_MCR[CTUEN].
1.8
ERR004334: MC_RGM: Device stays in reset state on
external reset assertion
Description:
On an external reset that is configured to be 'long' the device may remain in reset if the
system clock is configured to be sourced by a clock source other than the 16 MHz Internal
RC Oscillator (IRCOSC). Recovery from the reset in this case can only be achieved via a
power-down and power-up cycle.
The failure condition can only be seen with the following Reset Generation Module
(MC_RGM) settings for Functional Event Short Sequence register, External Reset field
(RGM_FESS[SS_EXR]) and Functional Bidirectional Reset Enable register, External Reset
field (RGM_FBRE[BE_EXR]):
Note:
RGM_FESS[SS_EXR] = 0b0 (long external reset)
RGM_FBRE[BE_EXR] = 0b0 (asserted on external reset event)
This condition can only occur if the cause of the device reset was the external reset
assertion. It does not occur if, for example, the device reset was due to a power-on.
DocID023968 Rev 6
7/22
21
Functional problems
Note:
SPC56xL70, SPC56xL64
RGM_FESS[SS_EXR] = 0b0 and RGM_FBRE[BE_EXR] = 0b0 are the default settings out
of power-on reset (POR).
Workaround:
There are two possible workarounds. In both, the workaround takes effect only after
software has reconfigured the MC_RGM. Therefore, in order to ensure that the issue cannot
occur after POR exit and before the software has executed the workaround, the system
clock must not be re-configured in the Mode Entry module (MC_ME) to be sourced by a
clock source other than the IRCOSC until after the workaround has been executed.
1.
Workaround #1:
Always configure the external reset event to prevent the external reset output to be driven
by the MC_RGM by writing 0b1 to RGM_FBRE[BE_EXR].
If the external reset has been configured to be long (RGM_FESS[SS_EXR] = 0b0) and self
testing has been enabled via the flash option, the external reset pin will still be asserted from
the time of external assertion until reset sequence exit after start-up self test execution.
If the external reset has been configured to be long (RGM_FESS[SS_EXR] = 0b0) and self
testing has been disabled via the flash option, the external reset pin will still be asserted
from the time of external assertion until the chip configuration is loaded from the flash during
reset PHASE3.
If the external reset has been configured to be short (RGM_FESS[SS_EXR] = 0b1), the
external reset pin will still be released as soon as it is no longer asserted from off-chip.
2.
Workaround #2:
Always configure the external reset as 'short' by writing 0b1 to RGM_FESS[SS_EXR]. In
addition, use software to trigger a long 'functional' or 'destructive' reset via the Mode Entry
module (MC_ME) if flash initialization or start-up self test is required.
The impact of this workaround is the additional time that the device is in reset (due to the
short reset sequence triggered by the external reset) and the overhead required for software
to check the reset status and request a software reset.
1.9
ERR004340: LINFlexD: Buffer overrun can not be detected in
UART Rx FIFO mode
Description:
When the LINFlexD is configured in UART Receive (Rx) FIFO mode, the Buffer Overrun
Flag (BOF) bit of the UART Mode Status Register (UARTSR) register is cleared in the
subsequent clock cycle after being asserted.
User software can not poll the BOF to detect an overflow.
The LINFlexD Error Combined Interrupt can still be triggered by the buffer overrun. This
interrupt is enabled by setting the Buffer Overrun Error Interrupt Enable (BOIE) bit in the LIN
Interrupt enable register (LINIER). But the BOF bit will be cleared when the interrupt routine
is entered, preventing the user to identify the source of error.
Workaround:
Buffer overrun errors in UART FIFO mode can be detected by enabling only this source in
the LIN Error Combined interrupt.
8/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
1.10
Functional problems
ERR006481: NZ4C3/NZ7C3: Erroneous Resource Full
Message under certain conditions
Description:
The e200zx core Nexus interface may transmit an erroneous Resource Full Message (RFM)
following a Program Trace history message with a full history buffer. The History information
for both of the messages are the same and the RFM should have not been transmitted. This
occurs when the instruction following the indirect branch instruction (which triggers the
Program Trace History message) would have incremented the History field. The instructions
must be executed in back to back cycles for this problem to occur. This is the only case that
cases this condition.
Workaround:
There are three possible workarounds for this issue:
1.11
1.
Tools can check to see if the Program Trace History message and proceeding
Resource Full Message (RFM) have the same history information. If the history is the
same, then the RFM is extraneous and can be ignored.
2.
Code can be rewritten to avoid the History Resource Full Messages at certain parts of
the code. Insert 2 NOP instructions between problematic code. Or inserting an “isync”
or an indirect branch somewhere in the code sequence to breakup/change the flow.
3.
If possible, use Traditional Program Trace mode can be used to avoid the issue
completely. However, depending on other conditions (Nexus port width, Nexus Port
speed, and other enabled trace types), overflows of the port could occur
ERR006726: NPC: MCKO clock may be gated one clock
period early when MCKO frequency is programmed as
SYS_CLK/8.and gating is enabled
Description:
The Nexus auxiliary message clock (MCKO) may be gated one clock period early when the
MCKO frequency is programmed as SYS_CLK/8 in the Nexus Port Controller Port
Configuration Register (NPC_PCR[MCKO_DIV]=111) and the MCKO gating function is
enabled (NPC_PCR[MCKO_GT]=1). In this case, the last MCKO received by the tool prior
to the gating will correspond to the END_MESSAGE state. The tool will not receive an
MCKO to indicate the transition to the IDLE state, even though the NPC will transition to the
IDLE state internally. Upon re-enabling of MCKO, the first MCKO edge will drive the
Message Start/End Output (MSEO=11) and move the tool's state to IDLE.
Workaround:
Expect to receive the MCKO edge corresponding to the IDLE state upon re-enabling of
MCKO after MCKO has been gated.
DocID023968 Rev 6
9/22
21
Functional problems
1.12
SPC56xL70, SPC56xL64
ERR006967: eDMA: Possible misbehavior of a preempted
channel when using continuous link mode
Description:
When using Direct Memory Access (DMA) continuous link mode Control Register
Continuous Link Mode (DMA_CR[CLM]) = 1) with a high priority channel linking to itself, if
the high priority channel preempts a lower priority channel on the cycle before its last
read/write sequence, the counters for the preempted channel (the lower priority channel)
are corrupted. When the preempted channel is restored, it continues to transfer data past its
"done" point (that is the byte transfer counter wraps past zero and it transfers more data
than indicated by the byte transfer count (NBYTES)) instead of performing a single
read/write sequence and retiring.
The preempting channel (the higher priority channel) will execute as expected.
Workaround:
Disable continuous link mode (DMA_CR[CLM]=0) if a high priority channel is using minor
loop channel linking to itself and preemption is enabled. The second activation of the
preempting channel will experience the normal startup latency (one read/write sequence +
startup) instead of the shortened latency (startup only) provided by continuous link mode.
1.13
ERR007120: NZxC3: DQTAG implemented as variable length
field in DQM message
Description:
The e200zx core implements the Data Tag (DQTAG) field of the Nexus Data Acquisition
Message (DQM) as a variable length packet instead of an 8-bit fixed length packet. This
may result in an extra clock ("beat") in the DQM trace message depending on the Nexus
port width selected for the device.
Workaround:
Tools should decode the DQTAG field as a variable length packet instead of a fixed length
packet.
1.14
ERR007227: FCCU: FCCU Output Supervision Unit (FOSU)
will not monitor faults enabled while already pending
Description:
The Fault Collection and Control Unit (FCCU) Output Supervision Unit (FOSU) will not
monitor the FCCU reaction to fault inputs that are enabled with an already pending
notification.
The FOSU monitoring is triggered by an edge from a fault input. The edge detection will be
blocked in following cases:
10/22
1.
When a fault input is disabled in the FCCU and a fault occurs,
2.
When a fault input is enabled in the FCCU and a fault occurs in the CONFIG state.
FOSU edge detection remains blocked until it gets initialized by a FCCU reaction or a
destructive reset
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
Workaround:
Apply the following procedure when enabling fault inputs in the FCCU in order to ensure
correct monitoring by the FOSU:
1.
Check for FCCU pending faults and clear them.
2.
Configure the FCCU as desired. In addition enable fault input for interrupt reaction
(software recovery mode) to an injected error on this input.
3.
Immediately on exiting the CONFIG state, check for FCCU pending faults. If there is a
fault status set then initiate a destructive reset.
4.
Clear the FOSU status by injecting a fault on the FCCU fault input configured for
software recovery mode. This will generate a FCCU reaction that will clear the FOSU
edge detection logic.
Apply the following procedure when exiting FCCU CONFIG state in order to ensure correct
monitoring by the FOSU:
1.
1.15
Check for FCCU pending faults. If there is a fault status set then initiate a destructive
reset
ERR007274: LINFlexD: Consecutive headers received by LIN
Slave triggers the LIN FSM to an unexpected state
Description:
As per the Local Interconnect Network (LIN) specification, the processing of one frame
should be aborted by the detection of a new header sequence and the LIN Finite State
Machine (FSM) should move to the protected identifier (PID) state. In the PID state, the LIN
FSM waits for the detection of an eight bit frame identifier value.
In LINFlexD, if the LIN Slave receives a new header instead of data response corresponding
to a previous header received, it triggers a framing error during the new header’s reception
and returns to IDLE state.
Workaround:
The following three steps should be followed:
Note:
1.
Configure slave to Set the MODE bit in the LIN Time-Out Control Status Register
(LINTCSR[MODE]) to '0'.
2.
Configure slave to Set Idle on Timeout in the LINTCSR[IOT] register to '1'. This causes
the LIN Slave to go to an IDLE state before the next header arrives, which will be
accepted without any framing error.
3.
Configure master to wait for Frame maximum time (TFrame_Maximum as per LIN
specifications) before sending the next header.
THeader_Nominal = 34 * TBit
TResponse_Nominal = 10 * (NData + 1) * TBit
THeader_Maximum = 1.4 * THeader_Nominal
TResponse_Maximum = 1.4 * TResponse_Nominal
TFrame_Maximum = THeader_Maximum + TResponse_Maximum
where TBit is the nominal time required to transmit a bit and NData is number of bits sent.
DocID023968 Rev 6
11/22
21
Functional problems
1.16
SPC56xL70, SPC56xL64
ERR007322: FlexCAN: Bus Off Interrupt bit is erroneously
asserted when soft reset is performed while FlexCAN is in
Bus Off state
Description:
Under normal operation, when FlexCAN enters in Bus Off state, a Bus Off Interrupt is issued
to the CPU if the Bus Off Mask bit (CTRL[BOFF_MSK]) in the Control Register is set. In
consequence, the CPU services the interrupt and clears the ESR[BOFF_INT] flag in the
Error and Status Register to turn off the Bus Off Interrupt.
In continuation, if the CPU performs a soft reset after servicing the bus off interrupt request,
by either requesting a global soft reset or by asserting the MCR[SOFT_RST] bit in the
Module Configuration Register, once MCR[SOFT_RST] bit transitions from 1 to 0 to
acknowledge the soft reset completion, the ESR[BOFF_INT] flag (and therefore the Bus Off
Interrupt) is re-asserted.
The defect under consideration is the erroneous value of Bus Off flag after soft reset under
the scenario described in the previous paragraph.
The Fault Confinement State (ESR[FLT_CONF] bit field in the Error and Status Register)
changes from 0b11 to 0b00 by the soft reset, but gets back to 0b11 again for a short period,
resuming after certain time to the expected Error Active state (0b00). However, this late
correct state does not reflect the correct ESR[BOFF_INT] flag which stays in a wrong value
and in consequence may trigger a new interrupt service.
Workaround:
To prevent the occurrence of the erroneous Bus Off flag (and eventual Bus Off Interrupt) the
following soft reset procedure must be used:
1.17
1.
Clear CTRL[BOFF_MSK] bit in the Control Register (optional step in case the Bus Off
Interrupt is enabled).
2.
Set MCR[SOFT_RST] bit in the Module Configuration Register.
3.
Poll MCR[SOFT_RST] bit in the Module Configuration Register until this bit is cleared.
4.
Wait for 4 peripheral clocks.
5.
Poll ESR[FLTCONF] bit in the Error and Status Register until this field is equal to 0b00.
6.
Write "1" to clear the ESR[BOFF_INT] bit in the Error and Status Register.
7.
Set CTRL[BOFF_MSK] bit in the Control Register (optional step in case the Bus Off
Interrupt is enabled).
ERR007352: DSPI: reserved bits in slave CTAR are writable
Description:
When the Deserial/Serial Peripheral Interface (DSPI) module is operating in slave mode
(the Master [MSTR] bit of the DSPI Module Configuration Register [DSPIx_MCR] is
cleared), bits 10 to 31 (31 = least significant bit) of the Clock and Transfer Attributes
Registers (DSPIx_CTARx) should be read only (and always read 0). However, these bits are
writable, but setting any of these bits to a 1 does not change the operation of the module.
Workaround:
There are two possible workarounds.
Workaround 1: Always write zeros to the reserved bits of the DSPIx_CTARn_SLAVE (when
operating in slave mode).
12/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
Workaround 2: Mask the reserved bits of DSPIx_CTARn_SLAVE when reading the register
in slave mode.
1.18
ERR007394: MC_ME: Incorrect mode may be entered on lowpower mode exit
Description:
For the case when the Mode Entry (MC_ME) module is transitioning from a run mode
(RUN0/1/2/3) to a low power mode (HALT/STOP/STANDBY(a)) if a wake-up or interrupt is
detected one clock cycle after the second write to the Mode Control (ME_MCTL) register,
the MC_ME will exit to the mode previous to the run mode that initiated the low power mode
transition.
Example correct operation DRUN->RUN1-> RUN3->STOP->RUN3
Example failing operation DRUN->RUN1-> RUN3->STOP->RUN1
Workaround:
To ensure the application software returns to the run mode (RUN0/1/2/3) prior to the low
power mode (HALT/STOP/STANDBY(a)) it is required that the RUNx mode prior to the low
power mode is entered twice.
The following example code shows RUN3 mode entry prior to a low power mode transition.
ME.MCTL.R = 0x70005AF0; /* Enter RUN3 Mode & Key */
ME.MCTL.R = 0x7000A50F; /* Enter RUN3 Mode & Inverted Key */
while (ME.GS.B.S_MTRANS) {} /* Wait for RUN3 mode transition to complete */
ME.MCTL.R = 0x70005AF0; /* Enter RUN3 Mode & Key */
ME.MCTL.R = 0x7000A50F; /* Enter RUN3 Mode & Inverted Key */
while (ME.GS.B.S_MTRANS) {} /* Wait for RUN3 mode transition to complete */
/* Now that run mode has been entered twice can enter low power mode */
/* (HALT/STOP/STANDBY(a)) when desired. */
1.19
ERR007589: LINFlexD: Spurious timeout error when
switching from UART to LIN mode or when resetting
LINTCSR[MODE] bit in LIN mode
Description:
If the LINFlexD module is enabled in Universal Asynchronous Receiver/Transmitter (UART)
mode and the value of the MODE bit of the LIN Timeout Control Status Register (LINTCSR)
is 0 (default value after reset), any activity on the transmit or receive pins will cause an
unwanted change in the value of the 8-bit field Output Compare Value 2 (OC2) of the LIN
Output Compare register (LINOCR).
If the LINFlexD module is enabled in LIN mode and the value of the MODE bit of the LIN
Timeout Control Status register (LINTCSR) is changed from ‘1’ to ‘0’, then the old value of
the Output Compare Value 1 (OC1) and Output Compare Value 2 (OC2) of the LIN Output
Compare Register (LINOCR) is retained.
a. STANDBY mode is not available on all SPC56xx microcontrollers.
DocID023968 Rev 6
13/22
21
Functional problems
SPC56xL70, SPC56xL64
As a consequence, if the module is reconfigured from UART to Local Interconnect Network
(LIN) mode, or LINTCSR MODE bit is changed from ‘1’ to ‘0’, an incorrect timeout exception
is generated when the LIN communication starts.
Workaround:
If the LINFlexD module needs to be switched from UART mode to LIN mode, before writing
UARTCR[UART] to 1, ensure that the LINTCSR[MODE] is first set to 1.
If the LINFlexD module is in LIN mode and LINTCSR[MODE] needs to be switched from 1 to
0 in between frames, the LINOCR must be set to 0xFFFF by software.
1.20
ERR007877: FlexPWM: do not enable the fault filter
Description:
Operation of the fault pin filter of the Flexible Pulse Width Modulation (FLEX_PWM) may be
inconsistent if the Fault Filter is enabled, by setting the Filter Period greater than zero in the
Fault Filter register (FFILT[FILT_PER] > 0). The fault filter flag may be set even though the
pulse is shorter than the filter time.
Workaround:
Do not enable the PWM fault pin filters. Disable the fault pin filters by setting the Fault Filter
Period to 0 in the Fault Filter Register (FFILT[FILT_PER] = 0).
1.21
ERR008070: SWG: GPIO[55] functionality is not available
unless the SWG is powered down
Description:
The General Purpose Input/Output 55 (GPIO[55]) functionality on port D[7] is disabled if the
Sine Wave Generator module (SWG) is not in power down mode. The SWG will not enter
power down mode if the SWG clock input is disabled.
Workaround:
Ensure that the SWG clock input is enabled via the Aux Clock 0 Divider Configuration 1
register (CGM_AC0_DC1[DE1]=1) prior to putting the SWG in power down mode in the
SWG control register (SWG_CTRL[PDS] = 1). This will allow GPIO[55] functionality on port
D[7].
1.22
ERR008080: LINFlexD: TX pin gets set to High-Z when in
IDLE state
Description:
LINFlex drives the buffer enable signal for its transmit pin output (TX) to be ‘0’ after
transmitting the LIN frame. This causes the TX line to go to High-Z which will be an issue if
the associated LIN transceiver has an internal “pull down”.
Issue will also occur when module is configured in UART mode with the TX output pin
becoming High-Z when idle.
14/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
Workaround:
When operating in LIN mode, use a LIN transceiver with internal “pull up”. If the transceiver
has an internal “pull down”, add an external “pull up”.
When operating in UART mode, the issue can be worked around by enabling the internal
pull up on the TX pin using the corresponding SIU_MSCR register.
1.23
ERR008933: LINFlexD: Inconsistent sync field may cause an
incorrect baud rate and Sync Field Error Flag may not be set
Description:
When the LINFlexD module is configured as follows:
1.
LIN (Local Interconnect Network) slave mode is enabled by clearing the Master Mode
Enable bit in the LIN Control Register 1 (LINCR1[MME] = 0b0), and
2.
Auto synchronization is enabled by setting LIN Auto Synchronization Enable
(LINCR1[LASE] = 0b1)
The LINFlexD module may automatically synchronize to an incorrect baud rate without
setting the Sync Field Error Flag in the LIN Error Status register (LINESR[SFEF]) in case
Sync Field value is not equal to 0x55, as per the Local Interconnect Network (LIN)
specification.
The auto synchronization is only required when the baud-rate in the slave node cannot be
programmed directly in software and the slave node must synchronize to the master node
baud rate.
Workaround:
There are two possible workarounds.
Workaround 1:
When the LIN time-out counter is configured in LIN Mode by clearing the MODE bit of th LIN
Time-Out Control Status register (LINTCSR[MODE]= 0x0]):
1.
Set the LIN state Interrupt enable bit in the LIN Interrupt Enable register (LINIER[LSIE]
= 0b1)
2.
When the Data Reception Completed Flag is asserted in the LIN Status Register
(LINSR[DRF] = 0b1) read the LIN State field (LINSR[LINS])
3.
If LINSR[LINS]= 0b0101, read the Counter Value field of the LIN Time-Out Control
Status register (LINTCSR[CNT]), otherwise repeat step 2
4.
If LINTCSR[CNT] is greater than 0xA, discard the frame.
When the LIN Time-out counter is configured in Output Compare Mode by setting the
LINTCSR[MODE] bit:
DocID023968 Rev 6
15/22
21
Functional problems
SPC56xL70, SPC56xL64
1.
Set the LIN State Interrupt Enable bit in the LIN Interrupt Enable register
(LINIER[LSIE])
2.
When the Data Reception Completed flag bit is asserted in the LIN Status Register
(LINSR[DRF] = 0b1), read the LINSR[LINS] field
3.
If LINSR[LINS]= 0b0101, store LINTCSR[CNT] value in a variable (ValueA), otherwise
repeat step 2
4.
Clear LINSR[DRF] flag by writing LINSR[LINS] field with 0xF
5.
Wait for LINSR[DRF] to become asserted again and read LINSR[LINS] field
6.
If LINSR[LINS] = 0b0101, store LINTCSR[CNT] value in a variable (ValueB), else
repeat step 4
7.
If ValueB - ValueA is greater than 0xA, discard the frame.
Workaround 2:
Do not use the auto synchronization feature (disable with LINCR1[LASE] = 0b0) in LIN slave
mode.
1.24
ERR008970: LINFlexD: Spurious bit error in extended frame
mode may cause an incorrect Idle State
Description:
The LINFlexD module may set a spurious Bit Error Flag (BEF) in the LIN Error Status
Register (LINESR), when the LINFlexD module is configured as follows:
Data Size greater than eight data bytes (extended frames) by configuring the Data
Field Length (DFL) bitfield in the Buffer Identifier Register (BIDR) with a value greater
than seven (eight data bytes)
Bit error is able to reset the LIN state machine by setting Idle on Bit Error (IOBE) bit in
the LIN Control Register 2 (LINCR2)
As consequence, the state machine may go to the Idle State when the LINFlexD module
tries the transmission of the next eight bytes, after the first ones have been successfully
transmitted and Data Buffer Empty Flag (DBEF) was set in the LIN Status Register (LINSR).
Workaround:
Do not use the extended frame mode by configuring Data Field Length (DFL) bit-field with a
value less than eight in the Buffer Identifier Register (BIDR) (BIDR[DFL] < 8).
1.25
ERR009682: SPI: Inconsistent loading of shift register data
into the receive FIFO following an overflow event
Description:
In the Serial Peripheral Interface (SPI) module, when both the receive FIFO and shift
register are full (Receive FIFO Overflow Flag bit in Status Register is set (SR [RFOF] =
0b1)) and then the Clear Rx FIFO bit in Module Configuration Register (MCR [CLR_RXF]) is
asserted to clear the receive FIFO, shift register data is loaded into the receive FIFO after
the clear operation completes.
16/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Functional problems
Avoid a receive FIFO overflow condition (ie SR[RFOF] should never be 0b1). To do this,
monitor the RX FIFO Counter field of the Status Register (SR[RXCTR]) which indicates the
number of entries in receive FIFO and clear before the counter equals the FIFO depth.
Workaround:
Alternatively, after every receive FIFO clear operation (MCR[CLR_RXF] = 0b1) following a
receive FIFO overflow (SR[RFOF] = 0b1) scenario, perform a single read from receive FIFO
and discard the read data.
1.26
ERR009849: BAM: Serial boot not supported when flash is
programmed with Power Architecture instruction set
software
Description:
The Boot Assist Module (BAM) doesn't support serial boot when the flash memory is
programmed with Power Architecture instruction set (Book E) software. The functionality of
the BAM depends on the value of the Variable Length Encoding (VLE) bit in the Reset
Configuration Half Word (RCHW) of the bootable flash sector. If the VLE bit = 0, indicating
that Book E software is programmed in flash memory, the BAM doesn't function correctly
and the serial boot is not supported.
Workaround:
Erase flash memory or program flash memory with VLE software prior to executing serial
boot with Book E software.
1.27
ERR009928: FlexPWM: Half cycle automatic fault clearing
does not work in PWM submodule 0 under some conditions
Description:
When
1.
the EXT_SYNC signal is selected to cause initialization by setting the Submodule 0
Control 2 Register FlexPWM_SUB0_CTRL2[INIT_SEL] = 11, and
2.
a specific FAULTx input is associated with the submodule 0 outputs using the
Submodule 0 Fault Disable Mapping Register (FlexPWM_SUB0_DISMAP), and
3.
the respective bit for that FAULTx is 0 in the FFULL bit field of the Fault Status Register
(FlexPWM_FSTS), and
4.
the respective bit for that FAULTx is 1 in the FAUTO bit field of the Fault Control
Register (FlexPWM_FCTRL),
then the PWM outputs of submodule 0 is re-enabled at the cycle boundary (full cycle) and is
not reenabled at the cycle midpoint (half cycle).
Workaround:
When the EXT_SYNC signal is used to cause initialization in submodule 0 and the
submodule 0 PWM outputs are disabled by a specific FAULTx input, use full cycle automatic
fault clearing for the specific FAULTx input by setting the corresponding bit of the Fault
Status Register FlexPWM_FSTS[FFULL] to 1.
DocID023968 Rev 6
17/22
21
Functional problems
1.28
SPC56xL70, SPC56xL64
ERR009976: DSPI: Incorrect data received by master with
Modified transfer format enabled when using Continuous
serial communication clock mode
Description:
When the Deserial Serial Peripheral Interface (DSPI) module is configured as follows:
1.
Master mode is enabled (Master/Slave Mode Select bit in Module Configuration
Register is set (DSPI_MCR [MSTR] = 0b1))
2.
Modified transfer format is enabled (Modified Transfer Format Enable bit in Module
Configuration Register is set (DSPI_MCR [MTFE] = 0b1))
3.
Continuous serial communication clock mode is enabled (Continuous SCK Enable bit
in Module Configuration Register is set (DSPI_MCR [CONT_SCKE] = 0b1))
In this configuration if the frame size of the current frame is greater than the frame size of
the next received frame, corrupt frames are received in two scenarios:
1.
Continuous Peripheral Chip Select Enable bit in PUSH TX FIFO Register is set
(DSPI_PUSHR [CONT] = 0b1)
2.
DSPI_PUSHR [CONT] = 0b0 and lower significant bit of the frame is transferred first
(LSB first bit in Clock and Transfer Attributes Register is set (DSPI_CTAR [LSBFE]
=0b1))
Workaround:
To receive correct frames:
1.
When DSPI_PUSHR [CONT] = 0b1, configure the frame size of the current frame less
than or equal to the frame size of the next frame (for all frames).
2.
When DSPI_PUSHR [CONT] = 0b0, configure DSPI_CTAR [LSBFE] = 0b0.
Alternatively, configure the frame size of the current frame less than or equal to the
frame size of the next frame (for all frames).
Make sure that for all received frames, the bits are read equal to their respective frame sizes
and any extra bits during POP operation are masked.
1.29
DAN-0046129 STCU: Pattern to run the MBIST-only wrong
Description:
The reference manual in section "Self-test bypass and MBIST-only mode" states the pattern
to run the configuration MBIST-only. The user must copy this patter in a specific location of
the shadow sector of the flash.
The second word of 128-bit shows:
7F140000_00080388_FFFFFFFF_FFFFFFFF.
This value is wrong. The correct value is:
7F140000_000803A0_FFFFFFFF_FFFFFFFF.
Workaround:
The user must not consider the correct value and not use the wrong one.
18/22
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Appendix A
A.1
A.2
Additional information
Additional information
Reference document
SPC56XL70xx 32-bit MCU family built on the embedded Power Architecture®
(RM0342, Doc ID 023986).
32-bit Power Architecture® microcontroller for automotive SIL3/ASILD chassis and
safety applications (SPC56xL70, SPC56xL64 datasheet, Doc ID 027962).
Acronyms
Table 1. Acronyms
Acronym
Name
ADC
Analog-to-digital converter
APC
Analog pad control
BAM
Boot assist module
CMU
Clock monitor unit
CPU
Control processing unit
CHIERFR
Controller host interface error flag register
CTU
Cross trigger unit
DMA
Direct memory access
DPM
Decoupled parallel mode
ECSM
Error correction status module
FCCU
Fault collection and control unit
FIFO
First in first out
ILSA_EF
Illegal system bus address error flag
LSM
Lock step mode
MB
Message buffer
MCU
Microcontroller unit
PCR
Pad configuration register
POC
Protocol operation control
RCCU
Redundancy control checker unit
RWE
Read-while-write event error
RWW
Read while write
RXGMASK
RX global mask
RXIMR
RX individual mask register
SBC
Single bit correction-status
SLL
Secondary low/mid address space block lock register
DocID023968 Rev 6
19/22
21
Additional information
SPC56xL70, SPC56xL64
Table 1. Acronyms (continued)
Acronym
SWG
Sine-wave generator
XOSC
External oscillator
UART
Universal Asynchronous Receiver/Transmitter
LINTCSR
OC2
LINOCR
20/22
Name
LIN Timeout Control Status Register
Output Compare Value 2
LIN Output Compare Register
MME
Master Mode Enable
LASE
LIN Auto Synchronization Enable
SFEF
Sync Field Error Flag
LINESR
LIN Error Status Register
BIDR
Buffer Identifier Register
DBEF
Data Buffer Empty Flag
DocID023968 Rev 6
SPC56xL70, SPC56xL64
Revision history
Revision history
Table 2. Document revision history
Date
Revision
05-Dec-2012
1
Initial release.
17-Sep-2013
2
Updated Disclaimer.
08-Jul-2014
3
Add the following errata:
– e6726
– e7120
– e7274
– e7322
– e7352
– e7394
07-Oct-2014
4
Add the following errata:
– ERR007877
– ERR008070
19-Nov-2015
5
Changes
Added the functional problems:
– ERR007589
– ERR008080
– ERR008933
– ERR008970
Updated the functional problems:
– ERR004186
– ERR007274
20-Mar-2018
6
Added the functional problems:
– ERR003511
– ERR006481
– ERR007227
– ERR009682
– ERR009849
– ERR009928
– ERR009976
– DAN-0046129
Updated the functional problems:
– ERR008933
DocID023968 Rev 6
21/22
21
SPC56xL70, SPC56xL64
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and
improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order
acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or
the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2018 STMicroelectronics – All rights reserved