STTH3R06UFY

STTH3R06UFY

  • 厂商:

    STMICROELECTRONICS(意法半导体)

  • 封装:

    DO-214AA(SMB)

  • 描述:

    Diode Standard 600V 3A Surface Mount SMBflat

  • 数据手册
  • 价格&库存
STTH3R06UFY 数据手册
STTH3R06-Y Datasheet Automotive 3 A - 600 V turbo 2 ultrafast rectifier Features SMB Flat SMB Flat Wettable leads • • • • • • • • AEC-Q101 qualified Ultrafast recovery Low switching losses High surge capability Low leakage current High junction temperature ECOPACK2 or ECOPACK3 compliant component on demand VRRM guaranteed from -40 to +175 °C Description The STTH3R06-Y is an ultrafast recovery power rectifier dedicated to energy recovery in automotive application housed in SMB Flat to improve space saving. It is especially designed for clamping function in energy recovery block. The compromise between forward voltage drop and recovery time offers optimized performances. Product status link STTH3R06-Y Product summary IF(AV) 3A VRRM 600 V Tj (max.) 175 °C VF (typ.) 1.1 V Trr (typ.) 35 ns DS10494 - Rev 2 - April 2022 For further information contact your local STMicroelectronics sales office. www.st.com STTH3R06-Y Characteristics 1 Characteristics Table 1. Absolute ratings (limiting values at Tj= 25 °C, unless otherwise specified) Symbol Parameter Value Unit 600 V VRRM Repetitive peak reverse voltage, Tj = -40 to +175 °C IF(AV) Average forward current TL = 90 °C δ = 0.5 3 A IFSM Forward surge current tp = 10 ms 30 A Tstg Storage temperature range -65 to + 175 °C Tj(1) Operating temperature range -40 to + 175 °C 1. (dPtot/dTj) < (1/Rth(j-a)) condition to avoid thermal runaway for a diode on its own heatsink. Table 2. Thermal resistance Symbol Rth(j-l) Parameter Junction to lead Value Unit 16 °C/W Max. Unit Table 3. Static electrical characteristic Symbol Parameter IR(1) Reverse leakage current VF(2) Forward voltage drop Test conditions Tj = 25 °C Tj = 125 °C Tj = 25 °C Tj = 150 °C VR = VRRM IF = 3 A Min. Typ. - 3 15 - 100 1.9 - 1.1 1.4 Min. Typ. Max. - 35 50 µA V 1. Pulsetest: tp = 5 ms, δ < 2% 2. Pulsetest: tp = 380 µs, δ < 2% To evaluate the conduction losses use the following equation: P = 1.1 x IF(AV) + 0.1 IF²(RMS) Table 4. Dynamic electrical characteristics Symbol trr Reverse recovery time tfr Forward recovery time VFP DS10494 - Rev 2 Parameter Forward recovery voltage Test conditions Tj = 25 °C IF = 1 A; dIF/dt = -50 A/µs; VR = 30 V Tj = 25 °C IF = 3 A; dIF/dt = 100 A/µs; VFR = 2.0 V - 130 - 5 Unit ns V page 2/10 STTH3R06-Y Electrical characteristics (curves) 1.1 Electrical characteristics (curves) Figure 1. Average forward power dissipation versus average forward current PF(AV) (W) 6 Figure 2. Forward voltage drop versus forward current (typical values) IF(A) 10.00 δ = 0.05 δ = 0.1 δ = 0.2 δ = 0.5 δ=1 5 4 1.00 Tj = 150°C Tj = 25°C 3 2 0.10 T 1 IF(AV) (A) 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 VF(V) tp δ =tp/T 3.5 0.01 Figure 3. Forward voltage drop versus forward current (maximum values) 10.00 0.0 4.0 IF(A) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Figure 4. Relative variation of thermal impedance junction to lead versus pulse duration 1.0 Zth(j- l) /Rth(j- l ) 0.9 Tj = 150°C 0.8 0.7 Tj = 25°C 1.00 0.6 0.5 0.4 0.10 0.3 0.2 Single pulse 0.1 VF(V) 0.01 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 Figure 5. Peak reverse recovery current versus dIF/dt (typical values) IRM(A) 13 VR = 400 V Tj = 125 °C 12 10 IF = IF(av) 9 8 IF = 0.5 x IF(av) 7 6 IF = 0.25 x IF(av) 5 4 3 2 1 dI F/dt (A/µ s) 0 0 50 DS10494 - Rev 2 100 150 200 250 300 350 400 450 500 1.E-03 1.E-02 1.E-01 1.E+00 1.E+01 Figure 6. Reverse recovery time versus dIF/dt (typical values) 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 IF = 2 x IF(av) 11 t p (s) 0.0 1.E-04 t RR(n s ) VR = 400 V Tj = 125 °C IF = 2 x IF(av) IF = IF(av) IF = 0.5 x IF(av) dI F/dt (A/µ s) 0 50 100 150 200 250 300 350 400 450 500 page 3/10 STTH3R06-Y Electrical characteristics (curves) Figure 7. Reverse recovery charges versus dIF/dt (typical values) 450 Figure 8. Reverse recovery softness factor versus dIF/dt (typical values) QRR(n C) 3.0 VR = 400 V Tj = 125 °C 400 Sfactor IF = IF(av) VR = 400 V Tj = 125 °C IF = 2 x IF(av) 2.5 350 300 2.0 IF = IF(av) 250 1.5 200 IF = 0.5 x IF(av) 150 1.0 100 0.5 50 dI F/dt (A/µ s) 0 0 50 100 150 200 250 300 350 400 450 dI F/dt (A/µ s) 0.0 0 500 Figure 9. Relative variation of dynamic parameters versus junction temperature 50 100 150 200 250 300 350 400 450 500 Figure 10. Transient peak forward voltage versus dIF/dt (typical values) VFP(V) 1.0 10 0.9 IF = IF(AV) Tj = 125 °C Sfactor 0.8 8 IRM 0.7 0.6 6 QRR 0.5 0.4 4 0.3 0.2 2 0.1 IF = IF(av) VR = 400 V Reference: T j = 125 °C Tj (°C) 0.0 25 50 75 100 dI F/dt (A/µ s) 125 Figure 11. Forward recovery time versus dIF/dt (typical values) 160 t FR(ns) 0 20 40 60 80 100 120 140 180 200 Figure 12. Junction capacitance versus reverse voltage applied (typical values) 100 C(pF) F = 1 MHz Vosc = 30 mVRMS Tj = 25 °C IF = IF(AV) VFR = 2.0 V Tj = 125 °C 140 160 120 100 10 80 60 40 20 dI F/dt (A/µ s) 0 20 40 DS10494 - Rev 2 60 80 100 120 140 160 180 VR(V) 1 200 1 10 100 1000 page 4/10 STTH3R06-Y Electrical characteristics (curves) Figure 13. Thermal resistance junction to ambient versus copper surface under each lead Rth(j-a)(°C/W) 150 SMB-Flat Epoxy printed board FR4, copper thickness: 70 μm 120 90 60 30 SCu (cm²) 0 0.0 DS10494 - Rev 2 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 page 5/10 STTH3R06-Y Package information 2 Package information In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK packages, depending on their level of environmental compliance. ECOPACK specifications, grade definitions and product status are available at: www.st.com. ECOPACK is an ST trademark. 2.1 SMB Flat package information • • Epoxy meets UL94, V0 Lead-free package Figure 14. SMB Flat package outline Table 5. SMB Flat mechanical data Dimensions Millimeters Ref. Min. Max. Min. Typ. Max. A 0.90 1.10 0.035 0.043 b 1.95 2.20 0.077 0.087 c 0.15 0.40 0.006 0.016 D 3.30 3.95 0.130 0.156 E 5.10 5.60 0.200 0.220 E1 4.05 4.60 0.159 0.181 L 0.75 1.50 0.030 0.060 L2 DS10494 - Rev 2 Typ. Inches 0.60 0.024 page 6/10 STTH3R06-Y SMB Flat package information Figure 15. Footprint recommendations, dimensions in mm (inches) 1.20 (0.047) 3.44 (0.136) 1.20 (0.047) 2.07 (0.082) 5.84 (0.230) millimeters (inches) DS10494 - Rev 2 page 7/10 STTH3R06-Y Ordering information 3 DS10494 - Rev 2 Ordering information Order code Marking Package Weight Base qty. Delivery mode STTH3R06UFY F3R6Y SMBflat 50 mg 5000 Tape and reel page 8/10 STTH3R06-Y Revision history Table 6. Document revision history DS10494 - Rev 2 Date Version Changes 04-Aug-2014 1 Initial release. 11-Apr-2022 2 Updated Section 2.1 SMB Flat package information. page 9/10 STTH3R06-Y IMPORTANT NOTICE – READ CAREFULLY STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgment. Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of purchasers’ products. No license, express or implied, to any intellectual property right is granted by ST herein. Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product. ST and the ST logo are trademarks of ST. For additional information about ST trademarks, refer to www.st.com/trademarks. All other product or service names are the property of their respective owners. Information in this document supersedes and replaces information previously supplied in any prior versions of this document. © 2022 STMicroelectronics – All rights reserved DS10494 - Rev 2 page 10/10
STTH3R06UFY 价格&库存

很抱歉,暂时无法提供与“STTH3R06UFY”相匹配的价格&库存,您可以联系我们找货

免费人工找货