400 W Triple Vout Series
Technical Specification
Industrial Grade AC/DC Power Supply With PFC
85-264 Vrms Input Voltage 12/24/36/48 V Semi-Regulated Output 400 W Output Continuous 500 W Output Transient Up to 91 % Full Load Efficiency
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs
400 W Open Frame
Configurations
• 400 W Encased or Open Frame • 800 W Encased Flat or Stacked • 1200 W Encased Flat or Stacked 400 W Encased
1200 W Encased Stacked
800 W Encased Flat
400 W Triple Vout Series Features • • • • • • • • High efficiency (91% for 48 VOUT Model at 400 W) Universal input voltage range Semi-regulated output for bus stability Parallel operation supported Integral fan cooling with speed control Active PFC; EN61000-3-2 compliant Low leakage; EN60601-1 compliant Low noise; EN55011 / EN55022 Class B compliant
Phone 1-888-567-9596
• Over–current, over–voltage, and over–temp protection • DC Power Good / AC Power Good signals • Remote enable input • Fan status output / Fan enable input • Small size: 3" x 5" x 1.45" (open frame) • RoHS 6/6 compliant • 5 V (250 mW) standby output
Doc.# 005-005053 Rev. A 09/08/08 Page 1
Product # AQ0400IUxT Series
www.synqor.com
Technical Specification
All specifications typical with TA = 25 °C, unless otherwise specified.
MAIN OUTPUT SPECIFICATIONS Output power (continuous) 85-132/170-264 Vrms (5 s transient) 85-132/170-264 Vrms 132-170 Vrms 12 Vout (model 1T) 24 Vout (model 2T) 36 Vout (model 3T) 48 Vout (model 4T) Efficiency 12 Vout, 115 Vrms, 400 W (see figs. 1, 3, 5, 7) 48 Vout, 115 Vrms, 400 W (see Note 1) 12 Vout, 230 Vrms, 400 W 48 Vout, 230 Vrms, 400 W Hold-up time (to -20%) 12 Vout (see Note 1) 24 / 36 / 48 Vout Maximum load capacitance 12 Vout 24 Vout 36 Vout 48 Vout Output ripple voltage Switching frequency (20 MHz BW) Twice line frequency (at 300W) Turn-on delay Transient response Iout steps from 50-75% At 0.2 A/µs Cyclic restart Cyclic operation Over line, load and temperature ΔVout caused by 50 W step ΔVout caused by 10 W step Nominal DC output voltage (at 250W) (Semi-regulated)
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
ACuQor 400W Triple Vout Series ELECTRICAL CHARACTERISTICS
400 W (Note 1) 500 W (Note 1) See Figure 10 12.4 V 25 V 37.5 V 50 V 88% typ. 90% typ. 89% typ. 91% typ. 16 ms @ 400 W 20 ms @ 400 W 16,000 µF 8,000 µF 4,000 µF 2,000 µF 0.5% p-p 5.0% p-p 2 s max. 3% typ / 6% max. dev. 100 ms recovery 110-120% 115% rated Iout ±6.0% 0.5% 0.1% +125 ºC (PCB Temp) 0.45 V (max) 4.15 V (min) 50 W 12.4 V ±6.0% 400 mV 10 mV 0.45 Vrms 4.2 A 5.0 A 2,000 uF 10 W 5.0 V ±5.0% 2.0 A 2.5 A 1,000 uF 85-264 Vrms 47-63 Hz 4 Arms 2 Arms >0.98 40 A max. 6.3 A GENERAL SPECIFICATIONS Fundamental ripple freq. Input 500 kHz Output 250 kHz Audible noise Fan speed varies with temp. 39 dBA @ 1 m max. Weight (EA \ EC) 343 g (12.1 oz) \ 446 g (15.7 oz) (SC \ RC) 846 g (29.8 oz) \ 879 g (31 oz) (UC \ TC) 1224 g (43.2 oz) \ 1298 g (45.8 oz) MTBF MIL-217 343.6 kHours Demonstrated TBD kHours ISOLATION SPECIFICATIONS Isolation voltage Input to output 3000 Vrms Input to ground 1500 Vrms Output to ground 500 Vrms Insulation resistance Output to ground 10 MΩ min. Leakage currents See Note 2 ENVIRONMENTAL CHARACTERISTICS Thermal performance Operating ambient (see Figure 9) Non-operating ambient Relative humidity Non-condensing Altitude Operating Non-operating Random vibration 5-500 Hz Shock Half-sine, 10 ms, 3 axes EMC CHARACTERISTICS Conducted emissions EN55011 and EN55022, FCC part15 Line frequency harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 ESD air EN61000-4-2 ESD contact EN61000-4-2 Radiated immunity EN61000-4-3 Fast transients EN61000-4-4 Line surge immunity EN61000-4-5 Conducted immunity EN61000-4-6 Power freq. mag. field EN61000-4-8 Voltage dip immunity EN61000-4-11 0 ºC to +70 ºC -40 ºC to +85 ºC 5-95% RH 10,000 ft max. 30,000 ft max. 0.03 g2/Hz 20 g peak Level B Class A Clause 5b Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 3 A/m Perf Criteria A, A, B