400 W Triple Vout Series
Technical Specification
Medical Grade AC/DC Power Supply With PFC
85-264 Vrms Input Voltage 12/24/36/48 V Semi-Regulated Output 400 W Output Continuous 500 W Output Transient Up to 91 % Full Load Efficiency
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs
400 W Open Frame
Configurations
• 400 W Encased or Open Frame • 800 W Encased Flat or Stacked • 1200 W Encased Flat or Stacked 400 W Encased
1200 W Encased Stacked
400 W Triple Vout Series Features • • • • • • • • High efficiency (91% for 48 VOUT Model at 400 W) Universal input voltage range Semi-regulated output for bus stability Parallel operation supported Integral fan cooling with speed control Active PFC; EN61000-3-2 compliant Low leakage; EN60601-1 compliant Low noise; EN55011 / EN55022 Class B compliant
800 W Encased Flat
• Over–current, over–voltage, and over–temp protection • DC Power Good / AC Power Good signals • Remote enable input • Fan status output / Fan enable input • Small size: 3" x 5" x 1.45" (open frame) • RoHS 6/6 compliant • 5 V (10 W) and 12 V (50 W) standby outputs
Product # AQ0400MUxT Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005048 Rev. A
09/08/08
Page 1
Technical Specification
All specifications typical with TA = 25 °C, unless otherwise specified.
MAIN OUTPUT SPECIFICATIONS Output power (continuous) 85-132/170-264 Vrms (5 s transient) 85-132/170-264 Vrms 132-170 Vrms 12 Vout (model 1T) 24 Vout (model 2T) 36 Vout (model 3T) 48 Vout (model 4T) Efficiency 12 Vout, 115 Vrms, 400 W (see figs. 1, 3, 5, 7) 48 Vout, 115 Vrms, 400 W (see Note 1) 12 Vout, 230 Vrms, 400 W 48 Vout, 230 Vrms, 400 W Hold-up time (to -20%) 12 Vout (see Note 1) 24 / 36 / 48 Vout Maximum load capacitance 12 Vout 24 Vout 36 Vout 48 Vout Output ripple voltage Switching frequency (20 MHz BW) Twice line frequency (at 300W) Turn-on delay Transient response Iout steps from 50-75% At 0.2 A/µs Cyclic restart Cyclic operation Over line, load and temperature ΔVout caused by 50 W step ΔVout caused by 10 W step Nominal DC output voltage (at 250W) (Semi-regulated)
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Medical
ACuQor 400W Triple Vout Series ELECTRICAL CHARACTERISTICS
400 W (Note 1) 500 W (Note 1) See Figure 10 12.4 V 25 V 37.5 V 50 V 88% typ. 90% typ. 89% typ. 91% typ. 16 ms @ 400 W 20 ms @ 400 W 16,000 µF 8,000 µF 4,000 µF 2,000 µF 0.5% p-p 5.0% p-p 2 s max. 3% typ / 6% max. dev. 100 ms recovery 110-120% 115% rated Iout ±6.0% 0.5% 0.1% +125 ºC (PCB Temp) 0.45 V (max) 4.15 V (min) 50 W 12.4 V ±6.0% 400 mV 10 mV 0.45 Vrms 4.2 A 5.0 A 2,000 uF 10 W 5.0 V ±5.0% 2.0 A 2.5 A 1,000 uF 85-264 Vrms 47-63 Hz 4 Arms 2 Arms >0.98 40 A max. 6.3 A GENERAL SPECIFICATIONS Fundamental ripple freq. Input Output Audible noise Fan speed varies with temp. Weight (EA \ EC) (SC \ RC) (UC \ TC) MTBF 500 kHz 250 kHz 39 dBA @ 1 m max.
MIL-217 Demonstrated ISOLATION SPECIFICATIONS Isolation voltage
343 g (12.1 oz) \ 446 g (15.7 oz) 846 g (29.8 oz) \ 879 g (31 oz) 1224 g (43.2 oz) \ 1298 g (45.8 oz) 343.6 kHours TBD kHours 4000 Vrms 1500 Vrms 1500 Vrms 5000 Vpulse 10 MΩ min. See Note 2
Input to output Input to ground Output to ground (BF & CF ) Output to ground (CFD) Output to ground
Insulation resistance Leakage currents
ENVIRONMENTAL CHARACTERISTICS Thermal performance Relative humidity Altitude Random vibration Shock EMC CHARACTERISTICS Conducted emissions Line frequency harmonics Voltage fluctuations ESD air ESD contact Radiated immunity Fast transients Line surge immunity Conducted immunity Power freq. mag. field Voltage dip immunity EN55011 and EN55022, FCC part15 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Level B Class A Clause 5b Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 3 A/m Perf Criteria A, A, B