Technical S pecification
BQ55120ETL16
35-55V
Input I nput
12V
Output
192Watt
Power
2000Vdc
Isolation
E ighth-brick Eighth-brick
DC Bus Conver ter
The BusQor™ BQ55120ETL16 bus converter is a next-generation, board-mountable, isolated, fixed switching frequency dc/dc converter that uses synchronous rectification to achieve extremely high conversion efficiency. The power dissipated by the converter is so low that a heatsink is not required, which saves cost, weight, height, and application effort. The BusQor series provides an isolated step down voltage from 35-55V to a 12V intermediate bus with no regulation in a standard “eighth-brick” module. BusQor converters are ideal for creating the mid-bus voltage required to drive point-of-load (non-isolated) converters in intermediate bus architectures. RoHS com pliant (see page 12 ). Operational Features
• Ultra-high efficiency, >95% at full rated load current • Delivers up to 16 amps of output current (192W) with minimal derating - no heatsink required • Input voltage range: 35V – 55V provides 12V bus for distributed power architectures • Fixed frequency switching provides predictable EMI performance
B us Bus Conver ter C onver
BQ55120ETL16 Module
Pr otection Features
• Input under-voltage lockout and over-voltage shutdown protects against abnormal input voltages • Output current limit and short circuit protection • Thermal shutdown
Mechanical Features
• Industry standard eighth-brick bus converter pin-out • Industry standard size: 0.90” x 2.3” (22.9x58.4mm) • Total height only 0.320” (8.13mm), permits better airflow and smaller card pitch • Total weight: 0.7 oz. (20 grams) • Flanged pins designed to permit surface mount soldering (avoid wave solder) using FPiP technique
Contr ol Features
• On/Off control referenced to input side (positive and negative logic options available)
• 2000V, 30 MΩ input-to-output isolation • UL/cUL 60950 recognized (US & Canada), basic insulation rating • TUV certified to EN60950 • Meets 72/23/EEC and 93/68/EEC directives • Meets UL94V-0 flammability requirements
Safety Features
Product # BQ55120ETL16
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2BE552B Rev. A
03/16/06
Page 1
Technical Specification
MECHANICAL DIAGRAM
2.00
(50.8)
Input: Output: Current: Package:
35-55 V 12 V 1 6 A (192W) 16 ( 192W) Eighth-brick
2.30
(58.4)
0.14
(3.6)
Top View
0.15
(3.8)
1 2 3
0.600
(15.24)
5
0.90
(22.9)
4
0.300
(7.62)
0.025 +0.013
(0.64 +0.33)
Side View
Bottom side Clearance
See Note 9
0.145
(3.68) See Note 3
Lowest Component
Load Board
Flanged Pin See Note 10
0.320 +0.015
(8.13 +0.38)
Overall height
NOTES
1) Pins 1-3 are 0.040” (1.02mm) diameter with 0.080” (2.03 mm) diameter standoff shoulders. 2) Pins 4 and 5 are 0.062” (1.57 mm) diameter with 0.100” (2.54 mm) diameter standoff shoulders. 3) Other pin extension lengths available. Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. 4) All Pins: Material - Copper Alloy Finish - Tin/Lead over Nickel plate 5) Undimensioned components are shown for visual reference only. 6) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 7) Weight: 0.7 oz. (20 g) typical 8) Workmanship: Meets or exceeds IPC-A-610C Class II 9) UL/TUV standards require a clearance of 0.04” (1.02mm) around primary areas of the module. Refer to section on Keep Out Areas under Application Considerations for details. 10) The flanged pins are designed to permit surface mount soldering (avoiding the wave soldering process) through the use of the flanged pin-in-paste technique.
PIN DESIGNATIONS
Pin No.
1 2 3 4 5
Name
Vin(+) ON/OFF Vin(-) Vout(-) Vout(+)
Function
Input Positive (35V - 55V) Logic control input to turn converter on and off. Input Negative Output Negative Output Positive
Product # BQ55120ETL16
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2BE552B Rev. A
03/16/06
Page 2
Technical Specification
BQ55120ETL16 ELECTRICAL CHARACTERISTICS
Parameter
ABSOLUTE MAXIMUM RATINGS
Input: Output: Current: Package:
35-55 V 12 V 1 6 A (192W) 16 ( 192W) Eighth-brick
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with appropriate power derating. Specifications subject to change without notice.
Min. Typ. Max.
60 56 2000 100 125 18 48 32.0 30.5 1.5 59.0 58.0 7 5 50 1.5\2.0 47 12.00 +20 \ 2.4 +4.1 \ 500 +1.7 \ 200 8.0 100 20 0 25 Vin / 8 +10 10 3,000 200 200 9 3 0 95.3 95.5 125 125 125 2000 30 13.8 150 40 16 4.7 0.1 15 0.1 100 12 55
Units
V V V °C °C V V V V V V V A A mA A 2s mA mA A µH\µF µF V %\V %\mV %\mV V mV mV A A V % mA µF mV µs ms ms % % % °C °C °C V MΩ
Notes & Conditions
Continuous Continuous Basic insulation, Pollution Degree 2
Input Voltage Non-Operating Operating Isolation Voltage (input to output) Operating Temperature Storage Temperature Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
-40 -55 -2 35
Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Input Over-Voltage Shutdown Turn-Off Voltage Threshold Turn-On Voltage Threshold Maximum Input Current No-Load Input Current Disabled Input Current Inrush Current Transient Rating Input Reflected Ripple Current Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
100% Load, 35Vin
RMS through 10µH inductor; Figures 12 & 14 RMS, full load; Figures 12 & 13 Fast blow external fuse recommended Internal values Typical ESR 0.1-0.2Ω, see Figure 12 48Vin, no load Figure 4 Figure 4 Figure 4 Over sample, line, load, temperature & life 20MHz bandwidth; Figures 12 & 15 Full Load, see Figures 12 & 15 Full Load, see Figures 12 & 15 Subject to thermal derating; Figures 5 - 8 Output Voltage 10% Low; Figure 16 % of rated output current Negative current drawn from output 12Vout at 16A Resistive Load 50% to 75% to 50% Iout max; Figure 11 To within 1% Vout nom Full load, Vout=90% nom.; Figures 9 & 10 -40°C to +125°C 2,500 µF load capacitance, Iout = 0A Figures 1 - 3 Figures 1 - 3 Package rated to 150°C UL rated max operating temp 130°C See Figures 5 - 8 for derating curves
Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Current Share Accuracy (2 units paralleled) Back-Drive Current Limit while Disabled Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Output Voltage during Load Current Transient For a Step Change in Output Current (0.1A/µs) Settling Time Turn-On Transient Turn-On Time Start-Up Inhibit Time Output Voltage Overshoot
EFFICIENCY
100% Load 50% Load
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature Board Temperature Transformer Temperature
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength) Isolation Resistance
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com).
Product # BQ55120ETL16
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2BE552B Rev. A
03/16/06
Page 3
Technical Specification
ELECTRICAL CHARACTERISTICS (Continued)
Parameter
FEATURE CHARACTERISTICS
Input: Output: Current: Package:
35-55 V 12 V 1 6 A (192W) 16 ( 192W) Eighth-brick
Min.
165 -1.0 2.4 2.4 -1.0
Typ.
190
Max.
215 0.8 18 18 0.8
Units
kHz V V V V V kΩ °C °C
Notes & Conditions
Switching Frequency ON/OFF Control (Option P) Off-State Voltage On-State Voltage ON/OFF Control (Option N) Off-State Voltage On-State Voltage ON/OFF Control (Either Option) Pull-Up Voltage Pull-Up Resistance Over-Temperature Shutdown Over-Temperature Shutdown Restart Hysteresis Load Current Scale Factor
RELIABILITY CHARACTERISTICS
Figures A & B Average PCB Temperature See App Note: Output Load Current Calc.
10 30 140 10 1333 2.81 0.91 150
Calculated MTBF (Telcordia) Calculated MTBF (MIL-217) Field Demonstrated MTBF
106 Hrs. TR-NWT-000332; 100% load,300LFM, 40oC Ta 106 Hrs. MIL-HDBK-217F; 100% load, 300LFM, 40oC Ta 106 Hrs. See our website for details
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
Notes
File # E194341, Basic insulation & pollution degree 2 Certified by TUV Test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8kV - NP, 15kV air - NP (Normal Performance) Section 7 - electrical safety, Section 9 - bonding/grounding
UL/cUL 60950 EN60950 72/23/EEC 93/68/EEC Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 GR-1089-CORE
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
# Units
32 5 5 10 5 5 5 3
Test Conditions
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability
95% rated Vin and load, units at derating point, 1000 hours
100g minimum, 2 drops in x and y axis, 1 drop in z axis -40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load 85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply robust, reliable product. Contact the factory for official product family qualification documents.
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and Feature Set for this family of DC/DC converters. Please consult the last page of this specification sheet for information on available options.
Product # BQ55120ETL16 Phone 1-888-567-9596
PATENTS
SynQor is protected under various patents, including but not limited to U.S. Patent # 5,999,417; 6,222,742 B1; 6,594,159 B2; 6,545,890 B2.
www.synqor.com
Doc.# 005-2BE552B Rev. A
03/16/06
Page 4
Technical Specification
100 11 10 95 9
Input: Output: Current: Package:
35-55 V 12 V 1 6 A (192W) 16 ( 192W) Eighth-brick
Power Dissipation (W)
35 Vin
8 7 6 5 4 3 2 1 0 35 Vin 48 Vin 55 Vin
Efficiency (%)
90
85
80
75
48 Vin 55 Vin
70 0 2 4 6 8 10 12 14 16
0
2
4
6
8
10
12
14
16
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
97
14 13
96
12
Output Voltage (V)
25 C 40 C 55 C
Efficiency (%)
11 10 9 8 7 6 35V 48V 55V
95
94
93 100 200 300 400
0
2
4
6
8
10
12
14
16
Air Flow (LFM)
Load Current (A)
Figure 3: Efficiency at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal input voltage).
18 16 14 12
Figure 4: Output voltage regulation vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Iout (A)
10 8 6 400 LFM (2.0 m/s) 4 2 0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (ºC)
Semiconductor junction temperature is within 1°C of surface temperature
Figure 5: Maximum output power derating curves vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin 1 (nominal input voltage).
Product # BQ55120ETL16 Phone 1-888-567-9596
Figure 6: Thermal plot of converter at 16 amp load current (192W) with 55°C air flowing at the rate of 200 LFM. Air is flowing across the converter from pin 3 to pin 1 (nominal input voltage).
Doc.# 005-2BE552B Rev. A 03/16/06 Page 5
www.synqor.com
Technical Specification
18 16
Input: Output: Current: Package:
35-55 V 12 V 1 6 A (192W) 16 ( 192W) Eighth-brick
Semiconductor junction temperature is within 1°C of surface temperature
14 12
Iout (A)
10 8 6 400 LFM (2.0 m/s) 4 2 0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (ºC)
Figure 7: Maximum output power derating curves vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM with air flowing from output to input (nominal input voltage).
Figure 8: Thermal plot of converter at 16 amp load current (192W) with 55°C air flowing at the rate of 200 LFM. Air is flowing across the converter from output to input (nominal input voltage).
Figure 9: Turn-on transient at half load (resistive load) and 3mF output capacitance (2.0ms/div). Input voltage pre-applied. Channel 1: Vout (2V/div). Channel 2: ON/OFF input (2V/div).
Figure 10: Turn-on transient at zero load and 3mF output capacitance (2.0ms/div). Input voltage pre-applied. Channel 1: Vout (2V/div). Channel 2: ON/OFF input (2V/div).
See Fig. 14
source impedance
10 µH
See Fig. 13 See Fig. 15
iS
VSOURCE
iC
DC/DC Converter 1 µF
VOUT
ceramic 450mΩ ESR capacitor tantalum capacitor
electrolytic capacitor
47 µF,