Technical Specification
IQ12-HPx Family
9-22 V
Continuous Input
1.8-48 V
Outputs
182 W
Max Power
2250 V dc
Isolation
Half-brick
DC-DC Converter
The InQor® Half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications.
Operational Features
• High efficiencies, up to 91% at full rated load current • Delivers full power with minimal derating - no heatsink required • Operating input voltage range: 9-22 V • Fixed frequency switching provides predictable EMI • No minimum load requirement
Mechanical Features
• Industry standard Half-brick pin-out configuration • Size: 2.390" x 2.490" x 0.512" (60.6 x 63.1 x 13.0 mm) • Total weight: 5 oz (142 g)
Protection Features
• Input under-voltage lockout • Input over-voltage shutdown • Output current limit and short circuit protection • Active back bias limit • Output over-voltage protection • Thermal shutdown
Control Features
• On/Off control referenced to input side • Remote sense for the output voltage • Output voltage trim range of -20%, +10%
COntents
Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IQ12 Family Electrical Characteristics (all output voltages) . . . . . . . . . . 3 IQ12 Family Standards & Qualification . . . . . . . . . . . . . . . . . . . . . . . . 4 IQ12 Family Figures (all output voltages) . . . . . . . . . . . . . . . . . . . . . . 5 IQ12018HPC60 Electrical Characteristics (1.8 Vout) & Figures . . . . . . . 6-7 IQ12033HPC50 Electrical Characteristics (3.3 Vout) & Figures . . . . . . . 8-9 IQ12050HPC36 Electrical Characteristics (5.0 Vout) & Figures . . . . . 10-11 IQ12120HPC15 Electrical Characteristics (12.0 Vout) & Figures . . . . 12-13 IQ12150HPC12 Electrical Characteristics (15.0 Vout) & Figures . . . . 14-15 IQ12240HPC7F Electrical Characteristics (24.0 Vout) & Figures . . . . 16-17 IQ12280HPC6F Electrical Characteristics (28.0 Vout) & Figures . . . . 18-19 IQ12400HPC4F Electrical Characteristics (40.0 Vout) & Figures . . . . 20-21 IQ12480HPC3H Electrical Characteristics (48.0 Vout) & Figures. . . . 22-23 Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
www.synqor.com Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 1
Page No.
safety Features
• 2250 V, 30 MW input-to-output isolation • UL 60950-1:2003, basic insulation • CAN/CSA-C22.2 No. 60950-1:2003 • EN60950-1:2001 • CE Marked • RoHS compliant (see Page 28)
Product # IQ12xxxHPXxx Phone 1-888-567-9596
Technical Specification
IQ12-HPx Family
Mechanical Drawing
2.486 2.00 1.400 1.000 .700 .400 [ 50,8 ] [ 35,56 ] [ 25,4 ] [ 17,78 ] [ 10,16 ]
±.020 [ 63,14
±0,5 ]
.243 ±.020 [ 6,17 ±0,5 ]
.512
[
+.002 -.005 +0,05 13 -0,12 OVERALL HEIGHT
]
.163 [ 4,14 ]
8
2.386 ±.020 [ 60,6 ±0,5 ] 1.90 [ 48,3 ]
7
6
5
4
.243 ±.020 [ 6,17 ±0,5 ]
TOP VIEW
1.90 [ 48,3 ]
SIDE VIEW
.233 ±.020 [ 5,92 ±0,5 ]
1
2
3
.543 .400 1.400
±.020 [ 13,79 ±0,5 ]
[ 10,16 ] [ 35,56 ]
THRU HOLE M3 (SEE NOTE 8) STANDOFFS (4)
.027
[
+.007 -.010 +0,17 0,69 -0,25
]
BOTTOMSIDE CLEARANCE
nOtes
1) 2) 3) 4) 5) 6) 7) 8) 9)
PIn DesIGnAtIOns
Pin 1 2 3 4 5 6 7 8 Notes: 1) 2) 3) SENSE(–) should be connected to Vout(–) either remotely or at the converter. Leave TRIM pin open for nominal output voltage. SENSE(+) should be connected to Vout(+) either remotely or at the converter.
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 2
Applied torque per screw should not exceed 6in-lb. (0.7 Nm). Baseplate flatness tolerance is 0.004" (.10 mm) TIR for surface. Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. Pins 4 and 8 are 0.080” (2.03 mm) dia. with 0.125” (3.18 mm) dia. standoff shoulders All Pins: Material: Copper Alloy Finish: Matte Tin over Nickel plate Undimensioned Components are shown for visual reference only Weight: 4.9oz (142g) Threaded or Non-Threaded options available All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
name Vin(+) ON/OFF Vin(–) Vout(–) SENSE(–) TRIM SENSE(+) Vout(+)
Function Positive input voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage Negative remote sense1 Positive remote sense3 Positive output voltage Output voltage trim2
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Technical Specification
IQ12-HPx Family
IQ12 FAMILY eLeCtRICAL CHARACteRIstICs (all output voltages)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
typ.
Max.
30 22 2250 2250 2250 100 125 18
Units notes & Conditions
V V V V dc V dc V dc °C °C V V Continuous Continuous
ABsOLUte MAXIMUM RAtInGs Input Voltage Non-Operating Operating Operating Transient Protection Isolation Voltage Input to Output Input to Base-Plate Output to Base-Plate Operating Temperature -40 Storage Temperature -55 Voltage at ON/OFF input pin -2 InPUt CHARACteRIstICs Operating Input Voltage Range 9 Input Under-Voltage Lockout Turn-On Voltage Threshold 9.2 Turn-Off Voltage Threshold 8.3 Lockout Voltage Hysteresis Input Over-Voltage Shutdown 32 Recommended External Input Capacitance Input Filter Component Values (L\C) DYnAMIC CHARACteRIstICs Turn-On Transient Turn-On Time Start-Up Inhibit Time 200 Output Voltage Overshoot IsOLAtIOn CHARACteRIstICs Isolation Voltage (dielectric strength) Isolation Resistance Isolation Capacitance (input to output) teMPeRAtURe LIMIts FOR POWeR DeRAtInG CURVes Semiconductor Junction Temperature Board Temperature Transformer Temperature Maximum Baseplate Temperature, Tb FeAtURe CHARACteRIstICs Switching Frequency 255 ON/OFF Control Off-State Voltage 2.4 On-State Voltage -2 ON/OFF Control Pull-Up Voltage Pull-Up Resistance Over-Temperature Shutdown OTP Trip Point Over-Temperature Shutdown Restart Hysteresis ReLIABILItY CHARACteRIstICs Calculated MTBF (Telcordia) TR-NWT-000332 Calculated MTBF (MIL-217) MIL-HDBK-217F Field Demonstrated MTBF
Baseplate temperature
12 9.5 8.6 0.9 35 820 0.34\32
22 9.8 8.9
See Note 1
V V V V µF Typical ESR 0.1-0.2 Ω µH\µF Internal values; see Figure E
10 230 0
250
ms ms %
Full load, Vout=90% nom. Figure F Maximum Output Capacitance See Absolute Maximum Ratings
30 1000 125 125 125 100 275 295 18 0.8 5 50 125 10 2.2 1.3
MΩ pF °C °C °C °C kHz V
See Note 2 Package rated to 150 °C UL rated max operating temp 130 °C
Isolation stage switching freq. is half this
Application notes Figures A & B V kΩ °C °C
Average PCB Temperature
106 Hrs. 80% load, 200LFM, 40 °C Ta 106 Hrs. 80% load, 200LFM, 40 °C Ta 106 Hrs. See our website for details
Note 1: Start-up guaranteed above 9.8 V, but will operate down to 9V Note 2: Higher values of isolation capacitance can be added external to the module.
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 3
Technical Specification
IQ12-HPx Family
IQ12xxxHPXxx Family standards & Qualification
STANDARDS COMPLIANCE
STANDARDS COMPLIANCE UL/cUL 60950-1 EN60950-1 Needle Flame Test (IEC 695-2-2) IEC 61000-4-2
Parameter
Notes & Conditions
File # E194341, Basic insulation Certified by TUV Test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability
Parameter
# Units
32 5 5 10 5 5 5 15 pins
Test Conditions
95% rated Vin and load, units at derating point, 1000 hours 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis 100g minimum, 2 drops in x and y axis, 1 drop in z axis -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load 85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day MIL-STD-883, method 2003
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 4
Technical Specification
IQ12-HPx Family
IQ12xxxHPXxx Family Figures (all output voltages)
120 Typical Current Limit Inception Point
Nominal Vout
Output Voltage (%)
100
80 Typical Output Voltage at Shutdown 60
40 Vin min 20 Vin nom Vin max 0
5.00
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150
Load Current (% )
Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/OFF Pin on Ch 2.
Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points.
100,000.0
100,000.0
Trim Resistance (kOhms)
10,000.0
Trim Resistance (kOhms)
1.8 V
3.3 V
5V
12 V
15 V
10,000.0
24 V
28 V
40 V
48 V
1,000.0
1,000.0
100.0
10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
100.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Increase in Vout (%)
Increase in Vout (%)
Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs.
10,000.0
Common Figure 4: Trim graph for trim-up 15 to 48 V outputs.
All voltages
Trim Resistance (kOhms) 1,000.0
100.0
10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Decrease in Vout (%)
Common Figure 5: Trim graph for trim down.
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 5
Technical Specification
Input: 9-22 V Output: 1.8 V Current: 60 A Part no.: IQ12018HPx60
IQ12018HPC60 eLeCtRICAL CHARACteRIstICs (1.8 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
19.4
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
300 2 0.06 240
380 3
TBD
A
1.782
1.8
1.818
V
±0.1 ±0.1 -27 1.755
±0.3 ±0.3 27 1.845
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
90 19
180 40 60
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 66.0 72.0 0.8 0.4 0.1
78.0
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
15,000
µF
110 400 -20 10 10 2.1 2.2 2.3
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range
82 85
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 6
Technical Specification
100 95
27 24 21
Input: 9-22 V Output: 1.8 V Current: 60 A Part no.: IQ12018HPx60
Power Dissipation (W)
90
Efficiency (%)
18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0 10 20 30 40 50 60
85 80 75 70 65 60 0 10 20 30 40 50 60 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
70 60 50
70 60 50
Iout (A)
Iout (A)
40 30 20 10 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
40 30 20 10 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (25 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 7
Technical Specification
Input: 9-22 V Output: 3.3 V Current: 50 A Part no.: IQ12033HPx50
IQ12033HPC50 eLeCtRICAL CHARACteRIstICs (3.3 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
28.0
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
340 2 0.12 440
430 3
TBD
A
3.267
3.3
3.333
V
±0.1 ±0.1 -50 3.218
±0.3 ±0.3 50 3.383
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
175 27
350 50 50
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 55.0 60.0 1.8 1.45 0.1
65.0
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
10,000
µF
100 200 -20 10 10 3.9 4.0 4.2
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5 Across Pins 8&4 Over full temp range
87 89
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 8
Technical Specification
100 95
30 27 24
Input: 9-22 V Output: 3.3 V Current: 50 A Part no.: IQ12033HPx50
Power Dissipation (W)
90
21 18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0 10 20 30 40 50
Efficiency (%)
85 80 75 70 65 60 0 10 20 30 40 50 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
60
60
50
50
40
40
Iout (A)
30
Iout (A)
400 LFM (2.0 m/s) 300 LFM (1.5 m/s)
30
20
20 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 10 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 25 40 55 70 85 25 40 55 70 85
10
200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
0
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (25 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 9
Technical Specification
Input: 9-22 V Output: 5.0 V Current: 36 A Part no.: IQ12050HPx36
IQ12050HPC36 eLeCtRICAL CHARACteRIstICs (5.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
30.2
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
325 2 0.15 350
410 3
TBD
A
4.95
5
5.05
V
±0.1 ±0.1 -75 4.875
±0.3 ±0.3 75 5.125
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
140 18
280 40 36
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 39.6 43.2 2.4 0.75 0.4
46.8
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
8,000
µF
165 200 -20 10 10 5.9 6.1 6.4
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range
87 90
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 10
Technical Specification
100 95
30 27 24
Input: 9-22 V Output: 5.0 V Current: 36 A Part no.: IQ12050HPx36
Power Dissipation (W)
90
21 18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0 6 12 18 24 30 36
Efficiency (%)
85 80 75 70 65 60 0 6 12 18 24 30 36 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
40 36 32 28
40 36 32 28
Iout (A)
20 16 12 8 4 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Iout (A)
24
24 20 16 12 8 4 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (10 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 11
Technical Specification
Input: Output: Current: Part no.:
9-22 V 12 V 15 A IQ12120HPx15
IQ12120HPC15 eLeCtRICAL CHARACteRIstICs (12.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.1
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
450 2 0.32 330
560 3
TBD
A
11.88
12
12.12
V
±0.1 ±0.1 -180 11.700
±0.3 ±0.3 180 12.300
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
110 17
220 30 15
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 16.5 18.0 6 0.45 1
19.5
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
1,500
µF
350 80 -20 10 10 14.040 14.640 15.240
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range
91 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 12
Technical Specification
100 95
21 18
Input: 9-22 V Output: 12 V Current: 15 A Part no.: IQ12120HPx15
Power Dissipation (W)
90
15 12 9 6 3 0 9 Vin 12 Vin 22 Vin
Efficiency (%)
85 80 75 70 65 60 0 3 6 9 12 15 9 Vin 12 Vin 22 Vin
0
3
6
9
12
15
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
18
18
15
15
12
12
Iout (A)
9
Iout (A)
400 LFM (2.0 m/s) 300 LFM (1.5 m/s)
9
6
6 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 3 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 25 40 55 70 85 25 40 55 70 85
3
200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
0
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 13
Technical Specification
Input: 9-22 V Output: 15 V Current: 12 A Part no.: IQ12150HPx12
IQ12150HPC12 eLeCtRICAL CHARACteRIstICs (15.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.3
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
400 2 0.43 375
500 3
TBD
A
14.85
15
15.15
V
±0.1 ±0.1 -225 14.625
±0.3 ±0.3 225 15.375
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
75 11
150 20 12
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 13.2 14.4 8 0.5 1.5
15.6
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
1,000
µF
660 80 -20 10 10 17.6 18.3 19.1
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range
90 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 14
Technical Specification
100 95
24 21
Input: 9-22 V Output: 15 V Current: 12 A Part no.: IQ12150HPx12
85 80 75 70 65 60 0 2 4 6 8 10 12 9 Vin 12 Vin 22 Vin
Power Dissipation (W)
90
18 15 12 9 6 3 0 0 2 4 6 8 10 12 9 Vin 12 Vin 22 Vin
Efficiency (%)
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
14 12 10
14 12 10
Iout (A)
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Iout (A)
8 6 4 2 0 25 40 55 70 85
8 6 4 2 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (1 V/div), Ch 2: Iout (5 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 15
Technical Specification
Input: 9-22 V Output: 24 V Current: 7.5 A Part no.: IQ12240HPx7F
IQ12240HPC7F eLeCtRICAL CHARACteRIstICs (24.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.7
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
330 2 0.7 360
410 3
TBD
A
23.76
24
24.24
V
±0.1 ±0.1 -360 23.400
±0.3 ±0.3 360 24.600
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
150 21
300 40 7.5
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 8.3 9.0 13 TBD 2.5
9.8
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
400
µF
1400 80 -20 10 10 28.1 29.3 30.5
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5 Across Pins 8&4 Over full temp range
89 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 16
Technical Specification
100 95
27 24 21
Input: 9-22 V Output: 24 V Current: 7.5 A Part no.: IQ12240HPx7F
Power Dissipation (W)
90
Efficiency (%)
18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0 1 2 3 4 5 6 7
85 80 75 70 65 60 0 1 2 3 4 5 6 7 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
9.0
9.0
7.5
7.5
6.0
6.0
Iout (A)
4.5
Iout (A)
400 LFM (2.0 m/s) 300 LFM (1.5 m/s)
4.5
3.0
3.0 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 1.5 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0.0 25 40 55 70 85 25 40 55 70 85
1.5
200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
0.0
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (2 V/div), Ch 2: Iout (2.5 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 17
Technical Specification
Input: Output: Current: Part no.:
9-22 V 28 V 6.5 A IQ12280HPx6F
IQ12280HPC6F eLeCtRICAL CHARACteRIstICs (28.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.9
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
350 2 0.8 390
440 3
TBD
A
27.72
28
28.28
V
±0.1 ±0.1 -420 27.300
±0.3 ±0.3 420 28.700
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
160 21
320 40 6.5
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 7.2 7.8 15 TBD 3
8.5
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
250
µF
1600 80 -20 10 10 32.8 34.2 35.6
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5 Across Pins 8&4 Over full temp range
89 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 18
Technical Specification
100 95
27 24 21
Input: 9-22 V Output: 28 V Current: 6.5 A Part no.: IQ12280HPx6F
Power Dissipation (W)
90
Efficiency (%)
18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0 1 2 3 4 5 6
85 80 75 70 65 60 0 1 2 3 4 5 6 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
7.0 6.0 5.0
7.0 6.0 5.0
Iout (A)
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Iout (A)
4.0 3.0 2.0 1.0 0.0 25 40 55 70 85
4.0 3.0 2.0 1.0 0.0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (2.5 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 19
Technical Specification
Input: 9-22 V Output: 40 V Current: 4.5 A Part no.: IQ12400HPx4F
IQ12400HPC4F eLeCtRICAL CHARACteRIstICs (40.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.7
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
400 2 1.2 350
500 3
TBD
A
39.6
40
40.4
V
±0.1 ±0.1 -600 39.000
±0.3 ±0.3 600 41.000
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
180 22
360 40 4.5
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 5.0 5.4 22 TBD 4
5.9
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
150
µF
1800 80 -20 10 10 46.8 48.8 50.8
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5 Across Pins 8&4 Over full temp range
89 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 20
Technical Specification
100 95
27 24 21
Input: 9-22 V Output: 40 V Current: 4.5 A Part no.: IQ12400HPx4F
Power Dissipation (W)
90
Efficiency (%)
18 15 12 9 6 3 0 9 Vin 12 Vin 22 Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
85 80 75 70 65 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 9 Vin 12 Vin 22 Vin
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
5.0 4.5 4.0 3.5
5.0 4.5 4.0 3.5
Iout (A)
2.5 2.0 1.5 1.0 0.5 0.0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Iout (A)
3.0
3.0 2.5 2.0 1.5 1.0 0.5 0.0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.05 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (1 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 21
Technical Specification
Input: 9-22 V Output: 48 V Current: 3.7 A Part no.: IQ12480HPx3H
IQ12480HPC3H eLeCtRICAL CHARACteRIstICs (48.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
InPUt CHARACteRIstICs Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUtPUt CHARACteRIstICs Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection eFFICIenCY 100% Load 50% Load
Min.
typ.
Max.
29.1
Units notes & Conditions
A mA mA V mA 500 V/ms; see Figure 6 RMS Fast acting external fuse recommended Vin min; trim up; in current limit
400 2 1.6 320
500 3
TBD
A
47.52
48
48.48
V
±0.1 ±0.1 -720 46.80
±0.3 ±0.3 720 49.20
% % mV V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1
0
200 27
400 50 3.7
mV mV A A V A mA
Full load Full load Subject to thermal derating Output voltage 10% Low
0 4.07 4.44 25 TBD 5
4.81
Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load)
100
µF
1800 80 -20 10 10 56.2 58.6 61.0
mV µs % % V
50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range
90 91
% %
See Figure 1 for efficiency curve See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 22
Technical Specification
100 95
24 21
Input: 9-22 V Output: 48 V Current: 3.7 A Part no.: IQ12480HPx3H
85 80 75 70 65 60 0.1 0.5 0.9 1.3 1.7 2.1 2.5 2.9 3.3 3.7 9 Vin 12 Vin 22 Vin
Power Dissipation (W)
90
18 15 12 9 6 3 0 0.1 0.5 0.9 1.3 1.7 2.1 2.5 2.9 3.3 3.7 9 Vin 12 Vin 22 Vin
Efficiency (%)
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
4
4
3
3
Iout (A)
2
Iout (A)
400 LFM (2.0 m/s)
2
400 LFM (2.0 m/s) 1 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0
1
300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s)
0 25 40 55 70 85
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.05 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (1 A/div).
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure 6: Output voltage response to step-change in input voltage (500 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (2 V/div), Ch 2: Vin (10 V/div).
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 23
Technical Specification
IQ12-HPx Family
BASIC OPERATION AND FEATURES
This converter series uses a two-stage power conversion topology. The first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide the functions of input/output isolation and voltage step-up or step-down to achieve the output voltage required. Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. This series of converters use the industry standard footprint and pin-out configuration.
CONTROL FEATURES
ReMOte On/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. ReMOte sense(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients.
ON/OFF
ON/OFF
Vin(_) Remote Enable Circuit
Vin(_) Negative Logic (Permanently Enabled) ON/OFF
TTL/ CMOS
5V 50k ON/OFF ON/OFF 50k
TTL
5V
100pF
Vin(_) Open Collector Enable Circuit
Vin(_) Direct Logic Drive
Vin(_)
Figure A: Various circuits for driving the ON/OFF pin.
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com
Figure B: Internal ON/OFF pin circuitry
Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 24
Technical Specification
IQ12-HPx Family
OUtPUt VOLtAGe tRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the load across the output is small enough to make the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-temperature shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value.
Rtrim-down =
where
(511)- 10.22 ∆%
(kW)
∆% =
Vnominal – Vdesired Vnominal
x 100%
To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be
Rtrim-up =
where
(
5.11VOUT x (100+∆%)
1.225∆%
_ 511 _ 10.22 ∆%
)
(kW)
Vout = Nominal Output Voltage
Trim graphs show the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the Trim pin. The node is internally bypassed to eliminate noise. total DC Variation of VOUt: For the converter to meet its full specifications, the maximum variation of the dc value of VOUT, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range.
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 25
Technical Specification
IQ12-HPx Family
APPLICATION CONSIDERATIONS
Input system Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Application Circuits: Figure D provides a typical circuit diagram which details the input filtering and voltage trimming. Input Filtering and external Capacitance: Figure E provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • Input Under-Voltage Lockout • Input Over-Voltage Shutdown • Output Over-Voltage Protection • Over Temperature Shutdown • Current Limit • Short Circuit Protection • Turned off by the ON/OFF input Figure F shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2:
Vin(+) External Input Filter
Electrolytic Capacitor
Vout(+) Vsense(+) Rtrim-up
or
Vin
ON/OFF
Trim
Vsense(_) Vin(_) Vout(_)
Rtrim-down
Cload
Iload
Figure D: Typical application circuit (negative logic unit, permanently enabled).
L
Vin(+) C Vin(_)
Figure E: Internal Input Filter Diagram (component values listed on the specifications page).
Product # IQ12xxxHPXxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 26
Technical Specification
IQ12-HPx Family
Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. thermal Considerations: The maximum operating baseplate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 ºC. 100 ºC - TA max Pdiss = RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. For convenience, power derating curves for an encased converter without a heatsink and with a typical heatsink are provided for each output voltage.
Vin
Under-Voltage Lockout TurnOn Threshold
ON/OFF
(neg logic)
ON
OFF ON
OFF
ON 9ms (typical turn on time)
Vout
(typical start-up inhibit period)
200ms
200ms
200ms
t0
t1
t2
t
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # IQ12xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ12HPX Rev. B 04/10/09 Page 27
Technical Specification
IQ12-HPx Family
PARt nUMBeRInG sYsteM
The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below.
IQ 1 2 0 18 H P C 6 0 n R s - G 6/6 RoHS Options Output Current Thermal Design Performance Level Package Size Output Voltage Input Voltage Product Family
(see Ordering Information)
ORDeRInG InFORMAtIOn
The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. Add “-G” to the model number for 6/6 RoHS compliance.
Model Number IQ12018HPw6NRS-G IQ12033HPw50NRS-G IQ12050HPw36NRS-G IQ12120HPw15NRS-G IQ12150HPw12NRS-G IQ12240HPw7FNRS-G IQ12280HPw6FNRS-G IQ12400HPw4FNRS-G IQ12480HPw3HNRS-G Continuous Input Voltage 9-22 V 9-22 V 9-22 V 9-22 V 9-22 V 9-22 V 9-22 V 9-22 V 9-22 V Output Voltage 1.8 V 3.3 V 5.0 V 12 V 15 V 24 V 28 V 40 V 48 V Maximum Output Current 60 A 50 A 36 A 15 A 12 A 7.5 A 6.5 A 4.5 A 3.7 A
The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance.
The following options must be included in place of the w x y z spaces in the model numbers listed above.
Options Description: w x y z Thermal Design Enable Logic Pin Style Feature Set
Application notes
A variety of application notes and technical white papers can be downloaded in pdf format from our website.
RoHs Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at rohs@synqor.com.
C - Encased with Threaded Baseplate D - Encased with Non-Threaded Baseplate
N - Negative
R - 0.180"
S - Standard
Not all combinations make valid part numbers, please contact SynQor for availability. See the Product Summary web page for more options.
PAtents
SynQor holds the following patents, one or more of which might apply to this product: 5,999,417 6,594,159 6,927,987 6,222,742 6,731,520 7,050,309 6,545,890 6,894,468 7,072,190 6,577,109 6,896,526 7,085,146
Contact synQor for further information:
Phone: Toll Free: Fax: E-mail: Web: Address:
978-849-0600 888-567-9596 978-849-0602 power@synqor.com www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA
Phone 1-888-567-9596
Warranty SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor.
Product # IQ12xxxHPXxx
www.synqor.com
Doc.# 005-IQ12HPX Rev. B
04/10/09
Page 28