IQ18033QTC30NRS

IQ18033QTC30NRS

  • 厂商:

    SYNQOR

  • 封装:

  • 描述:

    IQ18033QTC30NRS - Quarter-brick DC-DC Converter - SynQor Worldwide Headquarters

  • 数据手册
  • 价格&库存
IQ18033QTC30NRS 数据手册
Technical Specification IQ18-QTC Family 9-36 V Cont. Input 40 V Trans. Input 1.8-48 V Outputs 105 W Max Power 2250 V dc Isolation DC-DC Converter Quarter-brick The InQor® quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. Operational Features • High efficiencies, 83-91% at full rated load current • Delivers full power with minimal derating - no heatsink required • Operating input voltage range: 9-36 V, 40 V transient for 100 ms • Fixed frequency switching provides predictable EMI • No minimum load requirement Protection Features Mechanical Features • Industry standard quarter-brick pin-out configuration • Size: 1.54" x 2.39" x 0.50" (39.0 x 60.6 x 12.7mm) • Total weight: 3 oz (85 g) • Input under-voltage lockout • Output current limit and short circuit protection • Active back bias limit • Output over-voltage protection • Thermal shutdown Control Features • On/Off control referenced to input side • Remote sense for the output voltage • Output voltage trim range of -20%, +10% COnTenTS Mechanical Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IQ18 Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . 3 - 4 IQ18 Family Figures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 IQ18018QTC40 (1.8V, 40A) Characteristics and Figures . . . . . . . . . . 6 - 7 IQ18033QTC30 (3.3V, 30A) Characteristics and Figures . . . . . . . . . . 8 - 9 IQ18050QTC20 (5.0V, 20A) Characteristics and Figures . . . . . . . . 10 - 11 IQ18070QTC14 (7.0V, 14A) Characteristics and Figures . . . . . . . . 12 - 13 IQ18120QTC08 (12V, 8.0A) Characteristics and Figures . . . . . . . . 14 - 15 IQ18150QTC07 (15V, 7.0A) Characteristics and Figures . . . . . . . . 16 - 17 IQ18240QTC04 (24V, 4.0A) Characteristics and Figures . . . . . . . . 18 - 19 IQ18300QTC03 (30V, 3.0A) Characteristics and Figures . . . . . . . . 20 - 21 IQ18480QTC02 (48V, 2.0A) Characteristics and Figures . . . . . . . . 22 - 23 Application Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 - 27 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Page No. Safety Features • 2250 V, 30 MW input-to-output isolation • UL/cUL 60950-1 recognized (US & Canada), basic insulation rating • TUV certified to EN60950-1 • Meets 72/23/EEC and 93/68/EEC directives which facilitates CE Marking in user’s end product • Board and plastic components meet UL94V-0 standard • RoHS compliant (see Page 28) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 1 Technical Specification IQ18-QTC Family MECHANICAL DIAGRAM Top View 0.600 (15.24) 0.450 (11.43) 0.300 (7.62) 0.150 (3.81) 1.54 (39) 0.25 (6.4) 0.26 (6.7) 0.500 ± 0.025 (12.7 ± 0.63) Overall Height Side View 0.18 (4.57) 8 7 6 5 4 2.39 (60.6) 2.00 (50.8) 1.86 (47.21) M3 Threaded Inserts 4 Places See Note 9 0.18 (4.6) 0.47 (11.9) 1 2 3 0.300 (7.62) 0.010 ± 0.010 (0.25 ± 0.25) Bottom Side Clearance 0.600 (15.24) 1.030 (26.16) NOTES PIN DESIGNATIONS Pin No. 1 2 3 4 5 6 7 8 Notes: 1. SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2. Leave TRIM pin open for nominal output voltage. 3. SENSE(+) should be connected to Vout(+) either remotely or at the converter. 1) Pins 1-3, 5-7 are 0.040" (1.02mm) diameter with 0.080" (2.03 mm) diameter standoff shoulders. 2) Pins 4 and 8 are 0.062" (1.57 mm) diameter with 0.100" (2.54 mm) diameter standoff shoulders. 3) Recommended pin length is 0.03" (0.76mm) greater than the PCB thickness. 4) All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate 5) Undimensioned components shown are for visual reference only. 6) Weight: 3.02 oz. (85.7 g) typical 7) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 8) Workmanship: Meets or exceeds current IPC-A-610 Class II 9) M3 screws used to bolt unit’s baseplate to other surfaces (such as a heatsink) must not exceed 0.100" (2.54 mm) depth below the surface of the baseplate. 10) Applied torque per screw should not exceed 6in-lb. (0.7 Nm). 11) Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface. Name Vin (+) ON/OFF Vin (-) Vout (-) SENSE (-) TRIM SENSE (+) Vout (+) Function Positive input voltage TTL input to turn converter on and off, referenced to Vin (-) with internal pull up Negative input voltage Negative output voltage Negative remote sense 1 Output voltage trim 2 Positive remote sense 3 Positive output voltage Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 2 Technical Specification IQ18-QTC Family IQ18 FaMIly eleCTRICal ChaRaCTeRISTICS (all output voltages) aBSOlUTe MaXIMUM RaTInGS Input Voltage Non-Operating Operating Operating Transient Protection Isolation Voltage Input to Output Input to Base-Plate Output to Base-Plate Operating Temperature Storage Temperature Voltage at ON/OFF input pin InPUT ChaRaCTeRISTICS Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Recommended External Input Capacitance DynaMIC ChaRaCTeRISTICS Turn-On Transient Turn-On Time Start-Up Inhibit Time Output Voltage Overshoot ISOlaTIOn ChaRaCTeRISTICS Isolation Voltage (dielectric strength) Isolation Resistance Isolation Capacitance (input to output) 1 TeMPeRaTURe lIMITS FOR POWeR DeRaTInG CURVeS Semiconductor Junction Temperature Board Temperature Transformer Temperature Maximum Baseplate Temperature, TB FeaTURe ChaRaCTeRISTICS Switching Frequency ON/OFF Control Off-State Voltage On-State Voltage ON/OFF Control Pull-Up Voltage Pull-Up Resistance Over-Temperature Shutdown Over-Temperature Shutdown Restart Hysteresis RelIaBIlITy ChaRaCTeRISTICS Calculated MTBF (Telcordia) TR-NWT-000332 Calculated MTBF (MIL-217) MIL-HDBK-217F Field Demonstrated MTBF TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. -40 -55 -2 9 10.0 8.0 200 230 2.4 -2 Typ. 18 10.3 8.3 2 470 9 230 0 30 1000 250 5 50 125 10 2.5 2.0 Max. 40 36 40 2250 2250 2250 100 125 18 36 10.5 8.6 250 125 125 125 100 270 18 0.8 Units notes & Conditions V V V Vdc Vdc Vdc °C °C V V V V V µF ms ms % MW pF °C °C °C °C kHz V V V kW °C °C Continuous Continuous 100 ms transient, square wave Basic insulation, Pollution Degree 2 Baseplate temperature 40 V transient for 100 ms Typical ESR 0.1-0.2 W Full load, Vout=90% nom. See Figure F Maximum Output Capacitance See Absolute Maximum Ratings Package rated to 150 °C UL rated max operating temp 130 °C See Common Figure 3 for derating curve Regulation and Isolation stages Common Figures A & B Average PCB Temperature 106 Hrs 80% load, 300LFM, 40 °C TA 106 Hrs 80% load, 300LFM, 40 °C TA 106 Hrs See our website for details note 1: Higher values of isolation capacitance can be added external to the module. Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 3 Technical Specification IQ18-QTC Family IQ18 FaMIly STanDaRDS anD QUalIFICaTIOnS (all output voltages) STANDARDS COMPLIANCE Parameter STANDARDS COMPLIANCE UL/cUL 60950-1 EN60950-1 Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. Notes & Conditions File # E194341, Basic insulation Certified by TUV Test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance) Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. QUALIFICATION TESTING Parameter QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability # Units 32 5 5 10 5 5 5 15 pins Test Conditions 95% rated Vin and load, units at derating point, 1000 hours 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis 100g minimum, 2 drops in x and y axis, 1 drop in z axis -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load 85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day MIL-STD-883, method 2003 Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 4 Technical Specification IQ18-QTC Family IQ18 FaMIly FIGUReS (all output voltages) 120 Nominal Vout 100 Typical Current Limit Inception Point Output Voltage (%) 80 Typical Output Voltage at Shutdown 60 40 Vin, Min. 20 Vin, Typ. Vin, Max. 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Load Current (% ) Common Figure 1: Typical startup waveform. Input voltage preapplied, ON/OFF Pin on Ch 2. Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points. 100,000.0 1,000,000.0 Trim Resistance (kOhms) Trim Resistance (kOhms) 10,000.0 100,000.0 1,000.0 10,000.0 100.0 1,000.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 100.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1.8 V 3.3 V 5V 7V 12 V 15 V 24 V 30 V 48 V Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs. 10,000.0 % Decrease in Vout (All voltages) Common Figure 4: Trim graph for trim-up 15 to 48 V outputs. Trim Resistance (kOhms) 1,000.0 100.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 % Decrease in Vout (All voltages) Common Figure 5: Trim graph for trim down. Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 5 Technical Specification Input: Output: Current: Part no.: 9-36 V 1.8 V 40 A IQ18018QTC40 IQ18018QTC40 eleCTRICal ChaRaCTeRISTICS (1.8 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 1.782 -27 1.755 0 44 0 -20 117 Typ. 182 2.5 0.18 285 0.47\18 1.800 +0.1 +0.1 106 16 48 0.9 1.1 15 88 100 122 2667 83 85 Max. 12.8 230 4.0 30 1.818 +0.3 +0.3 27 1.845 210 30 40 52 50 10,000 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 6 Technical Specification 100 95 18 16 14 Input: Output: Current: Part no.: 9-36 V 1.8 V 40 A IQ18018QTC40 Power Dissipation (W) 90 Efficiency (%) 12 10 8 6 4 2 0 9 Vin 18 Vin 36 Vin 85 80 75 70 65 60 0 5 10 15 20 25 30 35 40 9 Vin 18 Vin 36 Vin 0 5 10 15 20 25 30 35 40 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 50 45 40 35 50 45 40 35 Iout (A) 25 20 15 10 5 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 30 30 25 20 15 10 5 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (10 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 7 Technical Specification Input: Output: Current: Part no.: 9-36 V 3.3 V 30 A IQ18033QTC30 IQ18033QTC30 eleCTRICal ChaRaCTeRISTICS (3.3 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 3.267 -50 3.218 0 33 0 -20 117 Typ. 172 2.4 0.16 400 0.47\18 3.300 +0.1 +0.1 66 10 36 1.7 0.85 15 125 50 122 1333 87 89 Max. 16.7 220 4.0 30 3.333 +0.3 +0.3 50 3.383 130 20 30 39 50 10,000 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 8 Technical Specification 100 95 20 18 16 Input: Output: Current: Part no.: 9-36 V 3.3 V 30 A IQ18033QTC30 Power Dissipation (W) 9 Vin 18 Vin 36 Vin 90 14 12 10 8 6 4 2 0 9 Vin 18 Vin 36 Vin 0 5 10 15 20 25 30 Efficiency (%) 85 80 75 70 65 60 0 5 10 15 20 25 30 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 35 30 25 35 30 25 Iout (A) 20 15 10 5 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 20 15 10 5 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (10 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 9 Technical Specification Input: Output: Current: Part no.: 9-36 V 5.0V 20 A IQ18050QTC20 IQ18050QTC20 eleCTRICal ChaRaCTeRISTICS (5.0 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 4.95 -75 4.875 0 22 0 -20 117 Typ. 184 2.6 0.2 370 0.47\18 5.00 +0.1 +0.1 68 10 24 2.3 0.6 15 120 100 122 1000 88 90 Max. 16.6 230 4.0 30 5.05 +0.3 +0.3 75 5.125 140 20 20 26 50 8,000 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 10 Technical Specification 100 95 16 14 Input: Output: Current: Part no.: 9-36 V 5.0V 20 A IQ18050QTC20 85 80 75 70 65 60 0 5 10 15 20 9 Vin 18 Vin 36 Vin Power Dissipation (W) 90 12 10 8 6 4 2 0 0 5 10 15 20 9 Vin 18 Vin 36 Vin Efficiency (%) Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 24 22 20 18 16 24 22 20 18 16 Iout (A) 12 10 8 6 4 2 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 14 14 12 10 8 6 4 2 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (5 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 11 Technical Specification Input: Output: Current: Part no.: 9-36 V 7.0 V 14 A IQ18070QTC14 IQ18070QTC14 eleCTRICal ChaRaCTeRISTICS (7.0 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 6.930 -105 6.825 0 15.4 0 -20 117 Typ. 189 2.6 0.26 360 0.47\18 7.000 +0.1 +0.1 48 8 16.8 5.0 0.5 15 200 50 122 667 90 90 Max. 16.1 240 4.0 30 7.070 +0.3 +0.3 105 7.175 100 20 14.0 18.2 50 4,000 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 12 Technical Specification 100 95 14 12 Input: Output: Current: Part no.: 9-36 V 7.0 V 14 A IQ18070QTC14 Power Dissipation (W) 90 10 8 6 4 2 0 9 Vin 18 Vin 36 Vin Efficiency (%) 85 80 75 70 65 60 0 2 4 6 8 10 12 14 9 Vin 18 Vin 36 Vin 0 2 4 6 8 10 12 14 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 18 16 14 12 18 16 14 12 Iout (A) 10 8 6 400 LFM (2.0 m/s) 4 2 0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 10 8 6 400 LFM (2.0 m/s) 4 2 0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 13 Technical Specification Input: Output: Current: Part no.: 9-36 V 12 V 8A IQ18120QTC08 IQ18120QTC08 eleCTRICal ChaRaCTeRISTICS (12 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 11.88 -180 11.7 0 8.8 0 -20 117 Typ. 237 2.7 0.4 360 0.47\18 12.00 +0.1 +0.1 44 8 9.6 10.0 0.4 15 470 50 122 444 91 90 Max. 14.1 300 4.0 30 12.12 +0.3 +0.3 180 12.3 90 20 8 10.4 50 1500 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; 12 Vout; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 14 Technical Specification 100 95 12 Input: Output: Current: Part no.: 9-36 V 12 V 8A IQ18120QTC08 10 Power Dissipation (W) 90 Efficiency (%) 8 85 80 75 70 65 60 0 1 2 3 4 5 6 7 8 9 Vin 18 Vin 36 Vin 6 4 9 Vin 18 Vin 36 Vin 0 0 1 2 3 4 5 6 7 8 2 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 10 9 8 7 10 9 8 7 Iout (A) 5 4 3 2 1 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 6 6 5 4 3 2 1 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (2.5 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 15 Technical Specification Input: Output: Current: Part no.: 9-36 V 15 V 7A IQ18150QTC07 IQ18150QTC07 eleCTRICal ChaRaCTeRISTICS (15 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 14.85 -225 14.625 0 7.7 0 -20 117 Typ. 205 2.8 0.45 375 0.47\18 15.00 +0.1 +0.1 66 12 8.4 10.7 0.3 15 800 50 122 333 90 91 Max. 17.1 260 4.0 30 15.15 +0.3 +0.3 225 15.375 130 20 7.0 9.1 50 1000 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 18 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 16 Technical Specification 100 95 16 14 Input: Output: Current: Part no.: 9-36 V 15 V 7A IQ18150QTC07 85 80 75 70 65 60 0 1 2 3 4 5 6 7 9 Vin 18 Vin 36 Vin Power Dissipation (W) 90 12 10 8 6 4 2 0 0 1 2 3 4 5 6 7 9 Vin 18 Vin 36 Vin Efficiency (%) Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 9 8 7 6 9 8 7 6 Iout (A) 5 4 3 2 1 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 5 4 3 2 1 0 0 25 40 55 70 85 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (1 V/div), Ch 2: Iout (2.5 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 17 Technical Specification Input: Output: Current: Part no.: 9-36 V 24 V 4A IQ18240QTC04 IQ18240QTC04 eleCTRICal ChaRaCTeRISTICS (24 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 23.76 -360 23.4 0 4.4 0 -20 117 Typ. 173 2.8 0.7 350 0.47\18 24.00 +0.1 +0.1 44 11 4.8 14 0.14 15 1200 100 122 190 89 90 Max. 15.7 220 4.0 30 24.24 +0.3 +0.3 360 24.6 90 20 4.0 5.2 50 400 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 18 Technical Specification 100 95 16 14 Input: Output: Current: Part no.: 9-36 V 24 V 4A IQ18240QTC04 85 80 75 70 65 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 9 Vin 18 Vin 36 Vin Power Dissipation (W) 90 12 10 8 6 4 2 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 9 Vin 18 Vin 36 Vin Efficiency (%) Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 5 5 4 4 Iout (A) 2 400 LFM (2.0 m/s) 1 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Iout (A) 3 3 2 400 LFM (2.0 m/s) 1 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.08 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (1 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 19 Technical Specification Input: Output: Current: Part no.: 9-36 V 30 V 3A IQ18300QTC03 IQ18300QTC03 eleCTRICal ChaRaCTeRISTICS (30 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 29.7 -450 29.25 0 3.3 0 -20 117 Typ. 175 2.5 0.7 340 0.47\18 30.0 +0.1 +0.1 46 10 3.6 18 0.11 15 1400 100 122 148 89 90 Max. 14.8 220 4.0 30 30.3 +0.3 +0.3 450 30.75 90 20 3.0 3.9 50 250 +10 +10 127 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 20 Technical Specification 100 95 14 12 Input: Output: Current: Part no.: 9-36 V 30 V 3A IQ18300QTC03 Power Dissipation (W) 90 10 8 6 4 2 0 9 Vin 18 Vin 36 Vin Efficiency (%) 85 80 75 70 65 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 9 Vin 18 Vin 36 Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 4.0 3.5 3.0 2.5 4.0 3.5 3.0 2.5 Iout (A) 2.0 1.5 400 LFM (2.0 m/s) 1.0 0.5 0.0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Iout (A) 2.0 1.5 400 LFM (2.0 m/s) 1.0 0.5 0.0 0 25 40 55 70 85 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.05 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (1 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 21 Technical Specification Input: Output: Current: Part no.: 9-36 V 48 V 2A IQ18480QTC02 IQ18480QTC02 eleCTRICal ChaRaCTeRISTICS (48 VOUT) TA = 25 °C, airflow rate = 300 LFM, VIN = 18 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. InPUT ChaRaCTeRISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (L\C) OUTPUT ChaRaCTeRISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise 1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient For a Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Load Current Scale Factor eFFICIenCy 100% Load 50% Load Parameter Min. 47.52 -720 46.80 0 2.2 0 -20 115 Typ. 165 2.5 0.8 380 0.47\18 48.0 +0.1 +0.1 66 19 2.4 30 0.05 15 3000 100 120 89 88 90 Max. 16.0 210 4.0 30 48.48 +0.3 +0.3 720 49.20 150 40 2 2.6 50 100 +10 +10 124 Units notes & Conditions A mA mA V mA A µH\µF V % % mV V mV mV A A V A mA µF mV µs % % % % % 9 VIN; trim up; in current limit 300 V/ms input transient; 100 µF output cap. RMS Fast acting external fuse recommended Internal values; see Figure E Over sample, line, load, temperature & life 20 MHz bandwidth Full Load Full Load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) 50% to 75% to 50% IOUT max To within 1% VOUT nom Measured across Pins 8 & 4; Common Figure 3 Measured across Pins 8 & 4 Over full temp range; % of nominal VOUT See Output Load Current app. note on our web See Figure 1 for efficiency curve See Figure 1 for efficiency curve note 1: Output is terminated with 1 µF ceramic. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 22 Technical Specification 100 95 16 14 Input: Output: Current: Part no.: 9-36 V 48 V 2A IQ18480QTC02 85 80 75 70 65 60 0.0 0.5 1.0 1.5 2.0 9 Vin 18 Vin 36 Vin Power Dissipation (W) 90 12 10 8 6 4 2 0 0.0 0.5 1.0 1.5 2.0 9 Vin 18 Vin 36 Vin Efficiency (%) Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 2.5 2.5 2.0 2.0 Iout (A) 1.0 400 LFM (2.0 m/s) 0.5 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0.0 0 25 40 55 70 85 Iout (A) 1.5 1.5 1.0 400 LFM (2.0 m/s) 0.5 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0.0 0 25 40 55 70 85 Ambient Air Temperature (°C) Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from pin 3 to pin 1 (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.02 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (5 V/div), Ch 2: Iout (1 A/div). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure 6: Output voltage response to step-change in input voltage (300 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (10 V/div). Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 23 Technical Specification IQ18-QTC Family BASIC OPERATION AND FEATURES This converter series uses a two-stage power conversion topology. The first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide the functions of input/output isolation and voltage step-up or step-down to achieve the output voltage required. Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. This series of converters uses the industry standard footprint and pin-out configuration. CONTROL FEATURES ReMOTe On/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. ReMOTe SenSe(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] < Sense Range % x Vout Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. ON/OFF ON/OFF Vin(_) Remote Enable Circuit Vin(_) Negative Logic (Permanently Enabled) ON/OFF TTL/ CMOS 5V 50k ON/OFF ON/OFF 50k TTL 5V 100pF Vin(_) Open Collector Enable Circuit Vin(_) Direct Logic Drive Vin(_) Figure A: Various circuits for driving the ON/OFF pin. Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Figure B: Internal ON/OFF pin circuitry Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 24 Technical Specification IQ18-QTC Family OUTPUT VOlTaGe TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be PROTECTION FEATURES Input Under-Voltage lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “0” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical Turn-On Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the load across the output is small enough to make the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. Rtrim-down = where 511 - 10.22 (kW) ∆% () ∆% = Vnominal – Vdesired x 100% Vnominal To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be Rtrim-up = where ( 5.11VOUT x (100+∆%) 1.225∆% _ 511 _ 10.22 ∆% ) (kW) Vout = Nominal Output Voltage Graphs on Page 3 show the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the Trim pin. The node is internally bypassed to eliminate noise. Total DC Variation of VOUT: For the converter to meet its full specifications, the maximum variation of the dc value of VOUT, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 25 Technical Specification IQ18-QTC Family APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. application Circuits: Figure D provides a typical circuit diagram which details the input filtering and voltage trimming. Input Filtering and external Capacitance: Figure E provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • Input Under-Voltage Lockout • Output Over-Voltage Protection • Over Temperature Shutdown • Current Limit • Short Circuit Protection • Turned off by the ON/OFF input Figure F shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2: Vin(+) External Input Filter Electrolytic Capacitor Vout(+) Vsense(+) Rtrim-up or Vin ON/OFF Trim Vsense(_) Vin(_) Vout(_) Rtrim-down Cload Iload Figure D: Typical application circuit (negative logic unit, permanently enabled). L Vin(+) C Vin(_) Figure E: Internal Input Filter Diagram (component values listed on the specifications page). Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 26 Technical Specification IQ18-QTC Family Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. Thermal Considerations: The maximum operating baseplate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 ºC. 100 ºC - TA max Pdiss = RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. For convenience, Figures 3 and 4 provide Power derating curves for an encased converter without a heatsink and with a typical 1/4" high heatsink. Vin Under-Voltage Lockout TurnOn Threshold ON/OFF (neg logic) ON OFF ON OFF ON 9ms (typical turn on time) Vout (typical start-up inhibit period) 200ms 200ms 200ms t0 t1 t2 t Figure F: Startup Inhibit Period (turn-on time not to scale) Product # IQ18xxxQTCxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 27 Technical Specification IQ18-QTC Family PaRT nUMBeRInG SySTeM The part numbering system for SynQor’s InQor dc-dc converters follows the format shown in the example below. ORDeRInG InFORMaTIOn The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional 3 characters for options. A “-G” suffix indicates the product is 6/6 RoHS compliant. Model Number IQ18018QTC40xyz IQ18033QTC30xyz IQ18050QTC20xyz IQ18070QTC14xyz IQ18120QTC08xyz IQ18150QTC07xyz IQ18240QTC04xyz IQ18300QTC03xyz IQ18480QTC02xyz Continuous Input Voltage 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V 9 - 36 V Transient Input Voltage 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms 40 V – 100 ms Output Voltage 1.8 V 3.3 V 5V 7V 12 V 15 V 24 V 30 V 48 V Maximum Output Current 40 A 30 A 20 A 14 A 8A 7A 4A 3A 2A IQ 18 018 Q T C 4 0 n R S - G 6/6 RoHS Options (see Ordering Information) Output Current Thermal Design (see Ordering Info) Performance Level Package Size Output Voltage Input Voltage Product Family The following options must be included in place of the x y z spaces in the model numbers listed above. Options Description: x y z Enable Logic N - Negative Pin Length R - 0.180" Feature Set S - Standard The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. application notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. RohS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at ohs@synqor.com. r Not all combinations make valid part numbers, please contact SynQor for availability. PaTenTS SynQor holds the following patents, one or more of which might apply to this product: 5,999,417 6,594,159 6,927,987 7,119,524 6,222,742 6,731,520 7,050,309 7,269,034 6,545,890 6,894,468 7,072,190 7,272,021 6,577,109 6,896,526 7,085,146 7,272,023 Contact SynQor for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 978-849-0600 888-567-9596 978-849-0602 p ower@synqor.com w ww.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 Warranty SynQor offers a three (3) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. Product # IQ18xxxQTCxx www.synqor.com Doc.# 005-IQ18QTX Rev. B 09/23/08 Page 28
IQ18033QTC30NRS 价格&库存

很抱歉,暂时无法提供与“IQ18033QTC30NRS”相匹配的价格&库存,您可以联系我们找货

免费人工找货