Technical Specification *
Quarter
Brick
48Vin 18Vout 5.6A
100 Watt, No Heatsink, Isolated DC/DC Converter
The PQ65180QGA06 PowerQor™ Giga quarterbrick converter is a next-generation, board-mountable, isolated, fixed switching frequency DC/DC converter that uses synchronous rectification to achieve extremely high conversion efficiency. The power dissipated by the converter is so low that a heatsink is not required, which saves cost, weight, height, and application effort. All of the power and control components are mounted to the multi-layer PCB substrate with high-yield surface mount technology. Since the PowerQor converter has no explicit thermal interfaces, it is extremely reliable.
Operational Features
• Ultra-high efficiency, 91% at full rated load current • Delivers up to 100 Watts of output power with minimal derating - no heatsink required • Wide input voltage range: 40V – 75V, with 100V 100ms input voltage transient capability • Fixed frequency switching provides predictable EMI performance • No minimum load requirement means no preload resistors required
PQ65180QGA06 Module
Protection Features
• Input under-voltage lockout disables converter at low input voltage conditions • Output current limit and short circuit protection protects converter and load from permanent damage and consequent hazardous conditions • Active back bias limit prevents damage to converter from external load induced pre-bias • Output over-voltage protection protects load from damaging voltages • Thermal shutdown protects converter from abnormal environmental conditions
Mechanical Features
• Industry standard quarter-brick pin-out configuration • Industry standard size: 1.45” x 2.3” (36.8x58.4mm) • Total height less than 0.40” (10.2mm), permits better airflow and smaller card pitch • Total weight: 1.2 oz. (34 grams) • Flanged pins designed to permit surface mount soldering (avoid wave solder) using FPiP technique
Safety Features
• 2000V, 30 MΩ input-to-output isolation provides input/output ground separation • UL/cUL 60950 recognized (US & Canada), basic insulation rating • TUV certified to EN60950 • Meets 72/23/EEC and 93/68/EEC directives which facilitates CE Marking in user’s end product • Board and plastic components meet UL94V-0 flammability requirements * Final datasheet pending ECO review and signature.
Doc.# 005-2QG581D Rev. B 9/14/04 Page 1
Control Features
• On/Off control referenced to input side (positive and negative logic options are available) • Remote sense for the output voltage compensates for output distribution drops • Output voltage trim permits custom voltages and voltage margining
Product # PQ65180QGA06 Phone 1-888-567-9596
Technical Specification
Quarter
Brick MECHANICAL DIAGRAM
2.30
(58.4)
48Vin 18Vout 5.6A
0.14
(3.6)
2.00
(50.8)
0.300
(7.62)
0.150 0.43
(10.9) (3.81)
1.45
(36.8)
0.300 0.600
(15.24) (7.62)
0.450
Top View
(11.43)
0.600
(15.24)
Max. Height
0.40
Bottom side Clearance
See Note 9 (10.2)
0.047+/-0.015
(1.19+/-0.38) Lowest Component Load Board Flanged Pin See Note 10
Side View
0.145
(3.68) See Note 3
NOTES
1) Pins 1-3, 5-7 are 0.040” (1.02mm) diameter with 0.080” (2.03 mm) diameter standoff shoulders. 2) Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100” (2.54 mm) diameter standoff shoulders. 3) Other pin extension lengths available. Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. 4) All Pins: Material - Copper Alloy Finish - Tin/Lead over Nickel plate 5) Undimensioned components are shown for visual reference only. 6) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 7) Weight: 1.2 oz. (34 g) typical 8) Workmanship: Meets or exceeds IPC-A-610C Class II 9) UL/TUV standards require a clearance greater than 0.04”
(1.02mm) between input and output for Basic insulation. This issue should be considered if any copper traces are on the top side of the user’s board. Note that the ferrite cores are considered part of the input/primary circuit.
PIN DESIGNATIONS
Pin No.
1 2 3 4 5 6 7 8
Notes: 1. If Sense regulation is needed, then pins 5 and 7 must be connected to Vout(+/-) at the load. 2. Leave Pin 6 open for nominal output voltage.
Name
Vin(+) ON/OFF Vin(-) Vout(-) SENSE(-) TRIM SENSE(+) Vout(+)
Function
Positive input voltage TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. Negative input voltage Negative output voltage Negative remote sense1 Output voltage trim2 Positive remote sense1 Positive output voltage
10) The flanged pins are designed to permit surface mount soldeing (avoiding the wave soldering process) through the use of the flanged pin-in-paste technique.
Product # PQ65180QGA06 Phone 1-888-567-9596 Doc.# 005-2QG581D Rev. B 9/14/04 Page 2
Technical Specification
Quarter
Brick PQ65180QGA06 ELECTRICAL CHARACTERISTICS
Parameter
ABSOLUTE MAXIMUM RATINGS
48Vin 18Vout 5.6A
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with appropriate power derating. Specifications subject to change without notice.
Min. Typ. Max.
100 80 100 2000 100 125 18 48 38 34.5 3.5 80 1.6 600 4 60 2.46\4.7 47 17.73 18.00 75 39 35.5 4.5 3.0 120 3 0.04
Units
V V V V °C °C V V V V V A mA mA A 2s mV mA mA A µF\µH µF V %\mV %\mV mV V mV mV A A V A mA µF dB mV mV µs
Notes & Conditions
continuous continuous 100ms transient, square wave Basic insulation, Pollution Degree 2
Input Voltage Non-Operating Operating Operating Transient Protection Isolation Voltage (input to output) Operating Temperature Storage Temperature Voltage at ON/OFF input pin Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Maximum Input Current No-Load Input Current Disabled Input Current Inrush Current Transient Rating Response to Input Transient Input Reflected Ripple Current Input Terminal Ripple Current Recommended Input Fuse Input Filter Component Values (C\L) Recommended External Input Capacitance Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise1 Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Input Voltage Ripple Rejection Output Voltage During Load Current Transient For a Step Change in Output Current (0.1A/µs) For a Step Change in Output Current (5A/µs) Settling Time Turn-On Transient Turn-On Time Start-Up Inhibit Time Output Voltage Overshoot 100% Load 50% Load Semiconductor Junction Temperature Board Temperature Transformer Temperature Isolation Voltage (dielectric strength) Isolation Resistance Isolation Capacitance2
-40 -55 -2 40 37 33.5 2.5
INPUT CHARACTERISTICS
100% Load, 40 Vin
20
1000V/ms input transient P-P thru 10µH inductor; Figs. 13 & 15 RMS; Figs. 13 & 14 fast blow external fuse recommended internal values, see Figure E Typical ESR 0.1-0.2Ω, see Figure 13 Factory pre-set with Sense(+), Sense(-) open
OUTPUT CHARACTERISTICS
18.27
17.43
+0.04 \ 7 +0.2 \ 36 +0.04 \ 7 +0.2 \ 36 +112 +300 18.57 50 15 6.7 10 0.3 10 70 250 250 800 120 30 5.6 7.7 0.6 50 2,000
0 5.9 0.1 0
over sample, line, load, temperature & life 20MHz bandwidth; Fig. 13 & 16 Full Load, see Figures 13 & 16 Full Load, see Figures 13 & 16 Subject to thermal derating; Figs. 5-8 Output Voltage 10% Low; Figure 17 Negative current drawn from output Negative current drawn from output 18Vout at 5.6A Resistive Load 120 Hz; Fig. 20 50% to 75% to 50% Iout max; Figure 11 50% to 75% to 50% Iout max; Figure 12 to within 1% Vout nom Full load, Vout=90% nom.; Figs. 9 & 10 -40°C to +125°C; Figure F 2,000 µF load capacitance, Iout = 0A Figures 1 - 4 Figures 1 - 4 Package rated to 150°C UL rated max operating temp 130°C See Figures 5 - 8 for derating curves
DYNAMIC CHARACTERISTICS
10 180
12 200 0 91.5 90.5
15 240
ms ms % % %
EFFICIENCY
TEMPERATURE LIMITS FOR POWER DERATING CURVES
125 125 125 2000 30 470
°C °C °C V MΩ pF
ISOLATION CHARACTERISTICS
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 2: Higher values of isolation capacitance can be added external to the module.
Product # PQ65180QGA06
Phone 1-888-567-9596
Doc.# 005-2QG581D Rev. B
9/14/04
Page 3
Technical Specification
Quarter
Brick ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
48Vin 18Vout 5.6A
Units
kHz V V V V V kΩ % % % °C °C
6
Min.
265 -2 2.4 2.4 -2
Typ.
290
Max.
355 0.8 18 18 0.8
Notes & Conditions
Regulation and Isolation stage
Switching Frequency ON/OFF Control (Option P) Off-State Voltage On-State Voltage ON/OFF Control (Option N) Off-State Voltage On-State Voltage ON/OFF Control (Either Option) Pull-Up Voltage Pull-Up Resistance Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection Over-Temperature Shutdown Over-Temperature Shutdown Restart Hysteresis Load Current Scale Factor Calculated MTBF (Telcordia) Calculated MTBF (MIL-217) Field Demonstrated MTBF
-20 117
Vin/6.5 40 122 125 10 175 2.8 1.8
9.2 +10 +10 127
Figures A, B Measured across Pins 8 & 4; Figure C Measured across Pins 8 & 4 Over full temp range; % of nominal Vout Average PCB Temperature See App Note: Output Load Current Calc.
RELIABILITY CHARACTERISTICS
10 Hrs. TR-NWT-000332; 80% load,300LFM, 40oC Ta 106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40oC Ta 106 Hrs. See website for latest values
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
Notes
File # E194341, Basic insulation & pollution degree 2 Certified by TUV test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8kV - NP, 15kV air - NP (Normal Performance) Section 7 - electrical safety, Section 9 - bonding/grounding
UL/cUL 60950 EN60950 72/23/EEC 93/68/EEC Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 GR-1089-CORE Telcordia (Bellcore) GR-513
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
# Units
32 5 5 10 5 5 5 15 pins
Test Conditions
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability
95% rated Vin and load, units at derating point, 1000 hours
100g minimum, 2 drops in x and y axis, 1 drop in z axis -40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load 85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact factory for official product family qualification document.
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and Feature Set for this family of DC/DC converters. Please consult the last page of this specification sheet for information on available options.
Product # PQ65180QGA06 Phone 1-888-567-9596
PATENTS
SynQor is protected under various patents, including but not limited to U.S. Patent numbers 5,999,417; 6,222,742 B1; 6,594,159 B2; 6,545,890 B2.
Doc.# 005-2QG581D Rev. B
9/14/04
Page 4
Performance Curves
Quarter
Brick
94 93
Efficiency (%)
95 90 85 80 75 70 65 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 40 Vin 48 Vin 75 Vin
48Vin 18Vout 5.6A
Efficiency (%)
92 91 90 89 88 0 100 200 300 400
Air Flow (LFM) 25 C 40 C 55 C
500
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Efficiency at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal input voltage).
8
12 11 10
Power Dissipation (W)
Power Dissipation (W)
9 8 7 6 5 4 3 2 1 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
7
6
40 Vin 48 Vin 75 Vin
5
4 0 100 200 300 400
Air Flow (LFM)
25 C 40 C 55 C
500
Load Current (A)
Figure 3: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
Figure 4: Power dissipation at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal input voltage).
6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 25 40 55 70 85
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 50 LFM (0.25 m/s)
Iout (A)
Ambient Air Temperature (oC)
Semiconductor junction temperature is within 1°C of surface temperature
Figure 5: Maximum output power derating curves vs. ambient air temperature for airflow rates of 50 LFM through 400 LFM with air flowing across the converter from pin 1 to pin 3 (nominal input voltage).
Product # PQ65180QGA06 Phone 1-888-567-9596
Figure 6: Thermal plot of converter at 6.1 amp load current (110W) with 55°C air flowing at the rate of 200 LFM. Air is flowing across the converter sideways from pin 1 to pin 3 (nominal input voltage).
Doc.# 005-2QG581D Rev. B 9/14/04 Page 5
Performance Curves
Quarter
Brick
6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 25 40 55 70 85
400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 50 LFM (0.25 m/s)
48Vin 18Vout 5.6A
Iout (A)
Ambient Air Temperature (oC)
Semiconductor junction temperature is within 1°C of surface temperature
Figure 7: Maximum output power-derating curves vs. ambient air temperature for airflow rates of 50 LFM through 400 LFM with air flowing lengthwise from input to output (nominal input voltage).
Figure 8: Thermal plot of converter at 6.0 amp load current (108W) with 55°C air flowing at the rate of 200 LFM. Air is flowing across the converter from input to output (nominal input voltage).
Figure 9: Turn-on transient at full load (resistive load) (10 ms/div). Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2: ON/OFF input (5V/div)
Figure 10: Turn-on transient at zero load (10 ms/div). Ch 1: Vout (5V/div) Ch 2: ON/OFF input (5V/div)
Figure 11: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 10µF, 100 mΩ ESR tantalum capacitor
and 1µF ceramic capacitor. Ch 1: Vout (500mV/div), Ch 2: Iout (2A/div). Product # PQ65180QGA06 Phone 1-888-567-9596
Figure 12: Output voltage response to step-change in load current (50%-75%50% of Iout(max): dI/dt = 5A/µs). Load cap: 100µF, 30 mΩ ESR tantalum capacitor and 1µF ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (2A/div).
Doc.# 005-2QG581D Rev. B 9/14/04 Page 6
Performance Curves
Quarter
Brick
48Vin 18Vout 5.6A
See Fig. 15
source impedance
10 µH
See Fig. 14 See Fig. 16
iS
VSOURCE
iC
DC/DC Converter 1 µF
VOUT
10 µF,
electrolytic capacitor
47 µF,